Loading...
05-192(3)-024I L J t-1 G I 0 B ILI. -- -- ; - HVAC EQUIPMENT CLEARANCES BEFORE COMMENCING WORK CONTRACTOR SHALL FIELD COORDINATE EXACT DIMENSIONS OF AHU'S, CU'S, AND RELATED EQUIPMENT AFFECTING INSTALLATION AND PROVIDE MINIMUM - - - CLEARANCES AS FOLLOWS I. 12' FROM CU'S TO WALLS 2. 18' BETWEEN CU'S 3. 4' ALL AROUND AHU'S WITHIN CLOSETS. GARAGE VENTILATION CALCULATION 4. 36' CLEAR IN FRONT OF APU'S AND CU's DISCONNECTS INTAKE AIR THROUGH GARAGE LOUVERED DOOR `�� 400 FPM X 0.25 EFFECTIVE PRESSURE AREA SF /DOOR X 2 GARAGE DOORS - 200 CFM NOT ALL AHU CLOSETS SHALL HAVE FULLY LOUVERED DOORS EXHAUST AIR THROUGH EXTERIOR WALL LOUVER UNLESS OTHERWISE NOTED. MINIMUN 4' CLEARANCE ALL 400 FPM X 0.25 EFFECTIVE PRESSURE AREA SF /LOUVER X 2 WALL LOUVERS - 200 CFM AROUND AHU (TYP) (2) 16X8 EXTERIOR WALL LOUVERS (W/0.25 SF `- OF E.P.A) 12' ABOVE FINISH FLOOR FOR 8X4 DOWN TO 5'D DRYER EXHAUST RIGID METAL CROSS VENTILATION. DUCT 26 GAUGE SMOOTH INTERIOR FINISH AS PER FMC504.6. RUN IN GROUND FLOOR CEILING SPACE AND TERMINATE OUTSIDE AT EXTERIOR LOUVER - - --- -- - ---------- - --- -- 5 - -- GARAGE EXHAUST CALCULATIONS o 75 C M CU 2 CARS o 100 CFM - 200 CFM — ° 6X6 D V 25 CFM W 6X4 CD 4 (D i1 t14, WIC D O o of ctz IOX6 _ ' ' CU O OIOX6 SR 2 -- -------- - i LOUVERS AT BOTTOM OF 6 GARAGE DOORS (W/0.25 SF OF GUEST BEDROOM 8X8 EP.A) FOR CROSS VENTILATION JF-I RAG 12X10 d TWO CAR O CFM II GARAGE RAG X6 CD X LL __..._ 1 4 Pr - -- .._._.... ...------- ...... - - -= -- ---- - - - - -- - - - -- 12XIO �II 12>9?� 5 0 8X8 o of RA 50 CFM RAG O 0 \__ ! 6X6 CD HALLWAY 4 o i N EF -I -I RETUR AIR GRILL TYPE D� (TYP) 200 CFM DEN 12X6 SR 0 200 CFM LIVING REFRI ANT LINES IN WALL FROM AHU -2 AT 2ND 2 'CFM ! 0 150 CFM o i 12X6 SR FLOO OZ AHU -I RUN UNDERGROUND, SIZ€D PER j 4 CD IOX8 CD 0 SCHEDULE ON M -3 AND MANUFACTURER'S 8 X TERRACE 12ECOMENDATION (TYP) 3 O i IOXIO IOXIO -- O O 200 CFM X RAG AG 12X6 SR �o II .. IOX8 ! _ FAMILY 12X10 IOXIO 24XI4 AN R H -1 I r U ! I (� I ! 6 25 C=M 4 D 6X CF I I +1 _00. GR DND F. F. N O I I -- -- — - -` )Of OR N C SECONDARY DRAIN CONNECTION WITH LOAT ' I 100 CFM \ i SWITCH DEVICE TO CONTROL OVE12FLO 50 CFM x 8X6 SR AUTOMATICALLY SHUTTING DOWN THE AHU (TYP o 4 6X6 CD O `O FOYER AHU -I i; 2) _ 14X12 12X10 X - - - -— —:: �- -_ _ co C 0 OP i co GAUGE, FROM HOOD 6 O 0 0 OX 0 0 0 TERMINATED AT WALL CAP X — 6. _ 100 CFM IOX6 SR 200 CFM 8X6 CD 150 CFM 12X6 S12 r 12 6 0 6 F. 100 CFM DINING ROOM 8X6 CD KITCHEN BREAKFAST 0 0 IOX 0 0 0 {� O _ D - i DV11 OHO - - WALL CAP LCEILING DIFFUSER SIDEW/� L REGISTER TYPE AO (TYP) TYPE 9 (TYP) C NORTH GROUND FLOOR - HVAC PLAN SCALE' 1/4' - 1' -0' B JORGE S A ?ZE, AI A FLA. REG. RA 9688 13 W ENTERED FEB 0 9 200 i.;:.. °' °* �/LeJLi ARCHITECTURE INC. 7166 SW 47th Street Miami, Florida 8816b AA26000646 Tel (806) 688 -2888 Fax (806) 888 -2888 IrmaiL• )aue�bellsonthnet 0 W CC$ d+ c� c+� n O � 'C l�l � O �T� O O M � ( 2 � 3 � 4 � 5 � 6 � 7 � 8 � 9 10 12 13 14 15 � 0 a 0 Z 0 i Z 0 N CO 1� �D lf� � (� CV — it $ Z U 1 O 0 w Q O W r y U J 2 Q� K O DRAWN BY: ISSUE DATE: M.S. OI -19 -05 CHECKED BY: SCALE: J.S.A. AS NOTED PROJECT NO. 04256 DRAWING NO. M -1 SHEET OF � ( 2 � 3 � 4 � 5 � 6 � 7 � 8 � 9 10 12 13 14 15 �