Loading...
05-192(3)-003\1 G MPR PLUS NOZZLES (SIZE PER PLAN) NOTE: INSTALL SPRINKLER AT FINISHED GRADE - I iii I I1-- iT = -ii - -11I FI-1=1 I � I1 APPROVED BACKFILL NOTE: CONTRACTOR MAY INSTALL PIPE TO SIDE INLET SPRAY SPRINKLER BODY BARBED MALE ELL FUNNY PIPE LATERAL PIPE o LATERAL TEE 12" POP -UP SPRINKLER ON POLY PIPE SWING JOINT DETAIL N.T.S. 4" MAX. BRAND PLASTIC VALVE BOX RISER WITH COVER MARKED RADIUS PATTERN "IRRIGATION" FLOW G.P.M. 1/2" IN TURF AND 2" EPDXY FILLED IN GROUND COVER CONNECTORS AREAS 8'r -15'r FINISH GRADE LATERAL LINE (COVER SOLENOID ACTUATED AS NOTED) REMOTE CONTROL TORO VALVE COMMON WIRE (PROVIDE 4" x 2-1/4" x 8" SOLID 24" OF WIRE IN A COIL) IN BRICK AT EACH CORNER 2" PVC CONDUIT. COMMON AND CONTROL MAINLINE (COVER AS WIRES (PROVIDE 24" OF NOTED IN LEGEND WIRE IN A COIL, EA.) Y -1 'r H 'r -1 'r H SCH 80 PVC NIPPLE MAINLINE (COVER AS NOTED ) 1.7 NOTE: USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS NECESSARY, FOR TRANSITION TO REQUIRED LATERAL LINE DEPTH. REMOTE CONTROL VALVE DETAIL 8'r -15'r H FINISH GRADE. N.T.S. .1 4' HEIGHT CHAINLINK FENCE PROPERTY LINE - 140.07' - - - -- - - - - - -- - -- - - -- - -- - -- - - - - - - -- - - -- -- - - - -- - - - - - -- - -- - 8' 4' WIDE x 4' HEIGHT SELF CLOSING SELF LACHING ALUMINUM PICKET GATE. 8, - I i ' - - - - - -T ---- - - - - -- - ---------- - - - - -- - -- ' RAIN SENSOR - - -- --- 1- 2'---- - - - - -� Z------ 4- 2' - - - -3 4R -- -- 1 2" " 1 �,�-- }5 -- 1 2r- }5 - -- I -- -- - - �+�- -- - - -- - i CONTROLLER i - - -- l ' i 12' 3 4 1 /2" 12' - - - I - -- - - - - - - - -- - 10' TRIANGLE 8'i S 1 2 8' 8' I' i i; OF VISIBILITY I 1 " I DRIVEWAY II - -I - -- - - -- I - TWO CAR GUEST 1 I I GARAGE ' II z I i BEDROOM J I 1 I I II 3/4" IN SLEEVE Q' w 12 I 10' TRIANGLE 13- a i I I I o OF VISIBILITY iLn DEN •; ' I �^ - -_ =_ LIVING ROOM I 3/4" " 12' I I - - - - - -- -- 8 /4 /2" Iw I 1 -- T z r- 112 ------ 112 - - - -- PORCH I I w 1 o. 15' -- - - -- - - -- 1 FAMILY ROOM - - -- c ' O - I TERRACE 1=171-1-1- T n r - - - - 8' 1/2' 8' 1/2' 12' W • IIIIIIIIIII II � 1 FOYER i WALKWAY I I -- -- - 1 -1 /4" IN - - -- o� SLEEVE _ POOL TERRACE " - - -- - - " - -- - -- 1/2" 8' 1/2" 12'� - - -- i 0' 1 -1 /4" I 8. L-------- - - - - -- - - PORCHI 12-4) i`I ID1I11111111IIIIliIIfID111 [212�I��I ®ll�l[lllll`I�, _ _ _ _ ; 5 / I R KITCHEN DINING ROOM 10' FOR SWIMMCING�ON ---- - - - - -J 4112' BREAKFAST II POOL (UNDER \ ' SEPARATE PERMIT) l ; v - 15. 1 3/4" 15' [I 11 III Il1JdIIIIII![Ell IIIIIIIGIlllOIIIIIIIIIIIJ11111,1 % /2" 4' WIDE x 4' HEIGHT _ 1 SELF CLOSING SELF LACHING -ALUMINUM 15 PICKET GATE. 1 /2" 15' 15' 1 -1/4" 1 Q I - - - 140.07' - I - PROPERTY LINE 4' HEIGHT CHAINLINK FENCE) IRRIGATION PLAN SCAI F• 1 /R"=1'-n" IRRIGATION NOTES AND SPECIFICATIONS 15' 15' - - -- VS.65 G.P.M 16.77 G.P.M. 01. All work to a installed according to local and county codes by a licensed and insured irrigation Contractor. Contractor shall include all labor, materials, and equipment necessary to complete the work detailed and intended in this plan. U.V. STABILIZED VALOX ® 02. It is the contractor's responsibility to visit the site and become familiar with the existing THERMOPLASTIC HOUSING conditions prior to entering into contract with the Owner or General Contractor. 03 All materials quantities sizes and all other Information contained In this Ian shall be 15' 1 -1 4" 3 4" 3/4" 15' 15' 15' 'I 3 1 25.80 G.P.M. BACKFLOW PREVENTER TI-1 /2" SUBMETER trli MASTER VALVE II77rN���fi7�itlr�3kl-01 SYMBOL BRAND MODEL BODY RISER NOZZLE RADIUS PATTERN DESIGN PRESSURE FLOW G.P.M. PRECIPIT. RATE TORO MPR570 6" POP -UP 8'r -15'r 8'r -15'r 30 P.S.I. 0.24 -0.85 1.75 TORO MPR570 6" POP-UP 'r -1 'r H 'r -1 'r H P.S.I. -1.6 1.7 TORO MPR570 6" POP-UP Y -1 'r H 'r -1 'r H P.S.I. 0.76-2-60 1.7 TORO MPR570 6" POP -UP 8'r -15'r H 8'r -15'r H 30 P.S.I. 1.00 -3.60 1.75 ■ TORO MPR570 6" POP -UP 4 -EST 5'X 18' 30 P.S.I. 0.45 1.55 0 TORO MPR570 6" POP -UP 4S -SST 2' X 6' 30 P.S.I. 0.09 1.55 i w Z w Z w 0' TOTAL IGHT OF WAY Q a Q 00 i \1 L r--1 G CLICK STOP SETTINGS - MEASURE RAINFALL I I I p UNDER PIPES AT 10' INTERVALS AND p IN QUANTITIES OF 1 /8" TO 11" verified by the contractor prior to entering into contract with the Owner or General 24 V IRRIG. WIRE . in PROVIDE 1 EXPANSION LOOP AT 50 a w Contractor. This plan is diagramatical and therefore site condition, scale of the IRRIGATION CONTROLLER INTERVALS. 0 ADJUSTABLE VENTILATION HOLES plan and changes during construction, may affect the location of the system components. The RAIN 3 #6 THW /CU IN 1"C. C contractor shall modify and /or adjust the system as required so as to comply with full coverage and SENSOR ELECTRICAL PANEL BACKFILL WITH PREVIOUSLY , ;�# • e design intent. Performance specifications vary between different manufacturers and even within EXCAVATED MATERIAL. - • S C z same manufacturer from year to year, therefore irrigation contractor shall verify prior to entering STATIONS LEGEND SAND OR FINE MATERIAL PIPE into contract with Owner o Contractor, that all equipment, sizes, and dimentions including pump, 1 #8 THW /CU IN 1 /2 "C I PASSING 1/4" SIEVE. c, ,, " mainlines, valves and lateral piping will provide the full coverage required. Should the contractor find (GROUND PER NEC) a discrepancy, error or omission he shall contact the Landscape Architect immediately. I 24 V CONTROL WIRES ZONE - 24V ELECT. VALVES PIPE OR CONDUIT (TYP.) 2 -5/8 x10 CU /CLAD 1 0 04. Piping in islands or narrow beds shall run to one side of the island or bed to allow for planting. GROUND RODS 1 (QUANITY & SIZE REQUIRED ALUMINUM MOUNTING BRACKET This includes mainlines and electrical wires. Piping and wiring should be installed after all the AS SHOWN IN PLAN) 6" FOR PIPE 2" AND SMALLER AND 12" 4" FOR PIPE OR CONDUIT 2" AND ,�,� FOR PIPE 2 1/2' AND LARGER WHERE SMALLER AND 12" FOR PIPE 2 1/2' AND TOTALLY SEALED & LEAD WIRES large plant material has been installed. EQU I PM ENT NOTES. V # r' CONTROL WIRE IS IN SAME TRENCH - IF WEATHERPROOF SWITCH o 05. The Landscape Architect has the right as Owner's authorized representative to at any stage 24 V GROUND WIRE LARGER, WHERE NO WIRES IN TRENCH. MECHANISM (U.L. LISTED) of the works, inspect, accept or reject any and all work and materials which in his (COMMON) BACKFLOW ONLY ONE PIPE IN TRENCH, PROVIDE 5" � 1 . EQUIPMENT MOUNTING C PREVENTER TO TRENCH WALL. N8JM AI TAVM&� gfJNG opinion, do not meet the requirements of the design intent. IRRIGATION SIMBOLS LEGEND T FYT. 06. All bellow ground pipe shall be poly(vinyl chloride) (PVC) pipe comforming to ASTM The equipment, shown in plan and typical electrical ZONE 24V ELECT. specification D 1785, Schedule 40, or it may be PVC MASTER VALVE MASTERVALVE PVC PIPE AS TRENCHING DETAIL RAIN SENSOR DETAIL p Y pipe conforming to ASTM D 2241, schematic diagram shall be mounted onthe building SPECIFIED IN Class 200. Mainline shall always be schedule 40, as well as any above ground pipes. ® STATION VALVES wall or on a Unistrut frame set into a 16" x 10" deep PLAN N.T.S. N.T.S. 07. All PVC fittings shall be Schedule 40, Type 1, NSF Approved conforming to the ASTM © 6 ZONE IRRIGATION CONTROLLER concrete footing x 6" longer than both ends of the D 2466 requirements, except as noted in the drawings. RRIGATION SUB - METER 08. All sprinkler heads shall meet the performance called for in this plan, and shall all be RAIN SENSOR Unistrut structure's length. BACKFLOW PREVENTION UNIT w INCLUDES TWO GATE VALVES AND from one single manufacturer. Although all shrub heads are specified with a radius, Q BACKFLOW PREVENTER 2. WORK PERFORMANCE: IRRIGATION SCHEMATIC DIAGRAM TWO GALV. NIPPLES contractor shall according to site conditions and space requirements, use the space required SM SUBMETER All electrical work to be performed by a licensed and N.T.S. Q head or in some cases a different pattern. Spacing shall also be adjusted so as not to overthrow > SCH. 40 / GALV NIPPLE W WATER METER insured electrical contractor, in strict compliance with water into impervious areas. ® D Q SCH. 40 / GALV WYE STRAINER W /30 09. All valves shall be installed inside a plastic valve box of a size proper to the valve(s) size. e# NUMBER DENOTES SPRAY HEAD RADIUS all sections of Article 680 of the National Electrical v MESH MONEL SCREEN W /HOSE BIB Valve boxes shall be installed over 3" of gravel for drainage and the top level with finished Code, Latest Edition. FOR FLUSHING } grade. Orlando Comas A.S.L.A. o SCH. 40 / GALV NIPPLE OUTSIDE WALL- 10. All wire to /from controller to the electric valves shall be #14, direct burial underground ;5 Z feed type. All connections shall be waterproof direct burial connectors and splices. All = wire shall be placed bellow the PVC pipe for protection of the wire, and shall be placed LANDSCAPE ARCHITECT F- F=- SCH. 40 / GALV NIPPLE W loosely to allow for contraction. U.1 IRRIGATION CONTROLLER _ = SCH. 40 / GALV NIPPLE 11. Thurst blocks shall be placed at all changes in direction of the main line. 7105 SW 8 Street, suite 407 _ = GATE VALVE AS SPECIFIED IN PLAN. 12. Trenching backfill shall be free of rocks, stones, or any other debris which may damage the IRRIGATION E U I PM ENT LEGEND Miami,Florida,33144 Z , SCH. 40 / GALV NIPPLE pipes and wires. a N Code Brand Description Size Phone: (305)264 -3841 C = w 13. All spray heads to be on pop -up risers, 6 " in sod areas & 12 " in areas of ground covers. U_ o They shall be installed so that the shrub head operates above the ground cover adult's height. © State Lic. No. LA1565 Ce O Q SCH. 40 / TORO Greenkeeper 212 Series Controller stations W Contractor shall consult with Landscape Architect on specific height of plant beds prior to = z GALV s❑ e-mail: ocomas @bellsouth.com = NIPPLE FINISHED GRADE SCH. 40 / GALV NIPPLE installation. TORO Rain Sensor N A = 0 D 14. Contractor shall coordinate with General Contractor, the installation of sleeves under all Z Z paved areas prior to their installation. ® TORO Series 252 Electric Valves 1 1 4" MAAMPM 1.5 -INCH PVC SCH 40 15. Backflow preventer if required shall be placed 18" min, above the highest sprinkler head. - - -- - Schedule 40 PVC Pipe - Main Line As shown CONDUIT AND FITTINGS 16. Contractor shall, prior to installing the irrigation heads, flush all lines with the maximum water ---- - Class 200 PVC Pipe - Lateral Lines 16s shown JUNCTION BOX pressure available, to remove dirt and grit. Lines shall be pressure tested at 150% ____ - Schedule 40 PVC Pipe - Sleeves lAs required of their operating pressure for leaks, and all leaks shall be repaired. This shall be done Note: FLOW FLOW 1 -INCH PVC SCH 40 CONDUIT prior to backflling. Irrigation Contractor may substitute the brand name specified for J another brand,however, the same performance is required for each B PVC MAIN (24" TO POWER SUPPLY 17. Contractor is responsible for keeping the work premisses clean of debris, and for substitution. MIN.COVER) SCH. 40 / PVC MAIN (COVER AS WIRES TO REMOTE removing all debris caused by his work from the site. GALV NIPPLE NOTED IN LEGEND) CONTROL VALVES 18. If an irrigation submeter is being used, contractor shall adjust layout according to provided submeter's g.p.m. flow. PRESSURE VACUUM BREAKER WALL MOUNT CONTROLLER DETAIL 19. Irrigation in right of way is not shown. Owner may request an extra zone(s) from N.T.S. irrigation contractor to water these area. ,.� - -i•, N.T.S. L -1 IRRIGATION PLAN JORGE S A ?ZE, AIA L SCALE: 1/8" = 1' -0" _ to 0 9 208 h .- LL AZZE INC. 7166 SW 47th Street Miami, Florida 33155 AA26000646 Tel (305) 663 -2666 Fax (305) 663 -2683 E -mail: jazze®bellsouthnet 0 w d" c� 0 > c� -a� -d o P4 CID c� 0 0 0 4-1 8 0 W -I O z ° Om ci - z o LA CO �,D Z Z Q CL Z O Q CD W Z DL Z G DRAWN BY: ISSUE DATE: J.L. 11.10.04 CHECKED BY: SCALE: O.C. I /8 " =1' -0" PROJECT NO. 04256 DRAWING NO. L-2 SHEET 2 OF 2 LL