Loading...
05-1454-015_x �W Iw�l; �w LO 'I � liLi I LOT 5 K x 69.60' x x x x x x x x x x- - — — — --- — — E FINISH GRADE T E RETAIN RAIN WATER 0 THE PROPERTY 1 4' FLF 'j POLE I i k\D 5r - orrx Or LO � Q FT. N 5 S FT. VE� \ DRAINFIEF D 2 'W x �3'L ` ` x 1,150 SF 4" �TG — 2 WAY NOTE: EXISTING TANK IN UNOBSTRUCTED AREA REAR YARD TO BE REMOVED 1050 GAL. SEPTIC TANK, x SEE CHART FOR SIZE I TANK MUST BE LOCATED 5' I x FROM STRUCTURE OF HOUSE 4' CLF 4" CTG — 2 WAY d x L0 D _— -- -- X X X X I 4" CTG 4" ® 1 /8 " /FT. — 24 FLI I I I I I I I I II I. I I II I I I II I. I I. I I II I I I• '- I I I II I I: I I I I I I 4" CTG — 2 WAY I i I i I II I I. I I I 1/2" HOSE BIBB (HB) W/ VACUUM BREAKER (VB) PLUMBING SITE PLAN SCALE: 1/811 a 11.011 FINISH GRADE TO RETAIN RAIN WATER ON THE PROPERTY 82.00' S.W. 66th AVENUE 15' ASPHALT PAVING 0 W OI �U U-) g C m V � zN 7r_ n MINIMUM REQUI SETBACK I I 1" SHUT —OFF VALVE IN VERTICAL — 18" A.F.F. l" WATER SERVICE PIPE = 17.1 FU 1" SHUT —OFF VALVE INBOX 1— — — 1" WATER METER ASSEMBLY N APPROVED 750 Permit no. p 4C9vtL' Date. /— //— OCR. 1200 Miami -Dade County 3' -6" Health Department 3' -8" l! L INSTALL i' OF SLICIT —:! —el SOEL UNDER BOTT+" " r H 4' -10' BOTTOM OF DR 7.5 LNG PERI INTER ✓/� SHALL BE AT LEAST 2.0 F R THAN TILE PROPOSED A' : , -`, • . _. ; ,. :'i' -� . T I,'CI I SEPTIC TANK 10_30_ GAL" (MIN) DRAWMD . 7l SQ. FT. O&N) SEPTIC TANK AND DRAINFIELD CALCULATIONS BASED ON CHAPTER 64E -6 FLORIDA ADMINISTRATIVE CODE 1, DAILY FLOW CALCULATIONS — TABLE I RESIDENCE - 4 BEDROOMS / 3 BATHS 4 BEDROOMS UP TO 3,024 S.F. AREA - 400 GPD TOTAL LIVING AREA OF RESIDENCE - 2,649 S.F. (UNDER A/C) 2,649 — 3,300 - 0 S.F O tow./75O S.F. - ADDTrORIAL FLOW 0 GPD TOTAL DAILY FLAW GPD 2. SEPTIC TANK SIZE — TABLE H 400 GPD DAILY SEWAGE FLOW - 1,050 GAL TANK 3. SIZE OF DRAINFIELD TABLE III MAX LOADING - 0.70 400 GPD / 0.70 - 571 S.F. DRAINFIELO SIZE USED (25' -0' x 23 -01 - 573 S.F. 4. SIZE OF UNOBSTRUCTTVE AREA- 575 X 2 - 1,150 S.F. UNOBSTRUCTED AREA CALCUALTED - 1,150 S.F. GAL. 750 900 1050 1200 W 3' -6" 3' -9' 3' -8" 4' -0' L 7' -2" 8' -0" V -3' 10' -0" H 4' -10' 4' -10" 4' -10' 4' -10" T min. 3" 3" 3' 3' D min. 4' -0" 4' -0" 4' -0' 4' -0' REINF. 6 X 6 10/10 CONC. 4000 PSI, 28 DAY SURFACE x % % SURFACE OF THE DRAINFIELD 24' MIN. 2• MIN. DEPTH OF UNSATISFACTORY SOIL WET SEASON WATER TABLE Z-UNSATISFACOTRY SOIL NOTE: THERE ARE NO PERTINENT FEATURES ON ADJACENT PROPERTIES OR ACROSS THE STREET THAT MAY AFFECT THE SYSTEM INSTALLATION. COLTRAIN AND JONES ARCH(TECTUR , PA. DESIGN + CAD PR DUC110N CONSTRUCTION ADN INISTAATION BUILDING INSPE 'IONS TEL(305) 285 -6723 FA)C 305) 285 -6722 535 SW 8 ST. SUITE 100 IAMI, FL 33130 REVISIONS /COMMENTS: W U z w � O cf) F W C > J Z J w W p� Z 0 m z Q z U 0 W Q O a Q M \I a 0 a: O -j LL a i r0 V/ SEAL: `0.4•• •••`�' •.�;;. •o �i fix, � . , • C' -�`.�, s MARK A. COLTRAIN -'21 0013380_ RICHARD K. JONES, AIA 4R• 00155755 - PLUMBING ST- NOTES/DATES: - - - - -� - JOB NO.: SHEET NO. 2005 -12 CARBONELL PERMIT SUBMITTAL DATE: 9/29/05 DATE PRINTED: 9/28/05 SCALE: AS NOTED DRAWN BY: M.R. .r