05-1454-012AIR 14ANDLING UNIT SCHEDULE
DESIGNATION
AHU -I
AHU-2
MANUFACTURER
CARRIER
CARRIER
MODEL NO.
FA48NCO36005
FA4BNCO3005
TOTAL AIR (CFM)
1200
1000
E.S.P. (IN OF W.G)
0.4
0.4
RPM
- - - --
- - - - --
H.P. (F.L.A.)
1/2 -3.4
1/3 -24
AVAILABLE SERVICE
208/1/60
208/1/60
OUTSIDE AIR (CFM) - INFILTRATION
- - --
- - --
MCA / MOCP (AMP.)
48.3/50
38.0/40.0
TOTAL COOLING - BTUH (o)
29,775
27,920
TOTAL COOLING - SENSIBLE BTU
27,814
26,500
TOTAL HEATING - BTUH
9,000
10,490
ELECTRIC HEATER TOTAL KW
5.0
5.0
ELECTRIC HEATER NO STEPS
I
I
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY
BE SUBMITTED FOR APPROVAL (TRANE,RHEEM,RUUD
OR YORK)
(■) ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF:
SUMMER: 80°F DRY BULB / 67OF WET BULB
WINTER: 7VF DRY BULB
V
AIR DISTRIBUTION SCHEDULE
FAN DESIGNATION
EF -1
DESIGNATION
A
B
C
D
MANUFACTURER
TITUS
TITUS
TITUS
TITUS
MODE.. AND
250 AA
272 FL
3 FL
3 FFL
CATALOG NO.
ALL ALUM.
ALL ALUM,
ALL ALUM.
ALL ALUM.
FRAME TYPE
SURFACE
SURFACE
SURFACE
SURFACE
50
(CEILING)
(SIDE WALL)
(CEILING E WALL)
(CEILING E WALL)
DEVICE TYPE
ADJUSTABLE
DOUBLE
SINGLE
SINGLE
0.9
MULTI- PATTERN
DEFLECTION
DEFLECTION
DEFLECTION
FUNCTION
SUPPLY
SUPPLY
RETURN E TRANS.
RETURN W/FILTER
PATTERN
SEE DRAWINGS
N/A
N/A
N/A
OPPOSED BLADE DAMPERS
SEE NOTE 4
SEE NOTE 4
SEE NOTE 4
SEE NOTE 4
REMARKS:
DIRECT
DIRECT
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITED FOR APPROVAL.
YES
2 ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETED.
YES
3. UNLESS OTI- E12VISE NOTED ALL AIR DEVICES FINISHES SHALL BE
BAKED OFF -WHITE
LIGHT SWITCH
4. SUPPLY,RETURN OR EXHAUST OUTLETS SERVED BY AN INDIVIDUAL DUCT BRANCH
LIGHT SWITCH
THAT ARE NOT PROVIDED WITH AN ACCESSIBLE MANUAL VOLUME DAMPER SHALL BE
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE
SUBMITTED FOR APPROVAL.
2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQUIPPED
WITH SAFETY DISCONNECT SWITCH.
SUPPLIED WITH INTEGRAL O.B.D.
FAN SCHEDULE
FAN DESIGNATION
EF -1
EF -2
EF -3
EF -4
AREA SERVED
MAST. BATH.
MAST. BATH.
BATH 2
BATH. 3
LOCATION
CEILING
CEILING
CEILING
CEILING
MANUFACTURER
GROAN
GROAN
B20AN
GROAN
MODEL N0.
S90
S50
S50
S50
TOTAL AIR (CFM)
90
50
50
50
E.S,P. (INCHES OF WATER)
0.125
0.125
0.125
0.125
SONES
1.5
0.9
0.9
0.9
RPM
- - - --
- - --
- - --
- - - --
H.P, (A =AMP - W= WATTS)
0.5 A
0.8 A
0.8 A
0.8 A
VOLT -PH -HZ
120 -1 -60
120 -1 -60
120-1 -60
120 -1 -60
DRIVE
DIRECT
DIRECT
DIRECT
DIRECT
BACKD12AFT DAMPER
YES
YES
YES
YES
INTERLOCK
LIGHT SWITCH
LIGHT SWITCH
LIGHT SWITCH
LIGHT SWITCH
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE
SUBMITTED FOR APPROVAL.
2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQUIPPED
WITH SAFETY DISCONNECT SWITCH.
SPRING TYPE HANGER
JOIST
UNISTRUT OR ANGULAR
STRUCTURE
RETURN AIR
STRUCTURAL GALVANIZED STE SUPPORTING CHANNEL WITH
ANGLE AND HANGING ROD WITH WASHERS E NUTS (TYPICAL)
VIBRATION HANGER'
SECONDARY DRAIN PAN j )
SUSPENDED AC MOUNTING DETAIL
N.T.S.
NOTE:
I. PROVIDE SECONDARY DRAIN PAN WITH AN APPROVED
WATER LEVEL DETECTOR OR FLOAT SWITCH DEVICE
THAT WILL CONTROL OVERFLOW BY AUTOMATICALY
SHUTTING DOWN THE AHU'S. FOR SWITCH MANUF. AND
MODEL NO PLEASE REFER TO PLUMBING DRAWINGS.
2. PROVIDE MIN. 4' CLEARANCE ALL AROUND AC UNIT
INSTALLED INSIDE AC CLOSET AS PER FMC 603.1.4
AIR COOLED CONDENSING UNIT SCHEDULE
DESIGNATION
CU -1
CU-2
MANUFACTURER
CARRIER
CARRIER
MODEL NO,
38T2AO30 -3
38T2AO36 -3
AVAILABLE SERVICE
208 -1 -60
208 -1-60
COMPRESSOR TYPE
SCROLL
SCROLL
NO. OF COMPRESSORS
I
1
COMPRESSORS FLA -LRA (EACH)
15.0 -72.5
17,9 -88.0
CONDENSER COIL AREA - SQ. FT.
15.0
15.2
NO. OF CONDENSER FANS
I
I
CONDENSER AIR (CFM)
3,000
3,000
FAN N.P. /FLA EACH
1/15 HP/ 0.5 AMP
1/5 HP/ 1.1 AMP
A.R.I. NOISE RATING - DB
7.3
7.3
TOTAL COOLING - BTUH (a)
27,920
29,775
TOTAL HEATING - BTUH (■)
10,490
9,000
S.E.E.R. W /MATCHED AHU (u)
12.0
12.0
C.O.P. W /MATCHED AHU (n)
N/A
N/A
CONDENSING UNIT MCA (AMPS)
19.3
23.4
CONDENSING UNIT MAX. FUSE
OR CKT. BREAKER AMPS
30
40
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE
SUBMITTED FOR APPROVAL (TRANE,RHEEM,RUUD OR YORK)
2 PROVIDE TIME GUARD II, START CAPACITOR AND RELAY, LIQUID
LINE FILTER DRYER E SOLENOID VALVE, 24 V CONTROL
TRANSFORMER E THERMOSTAT WITH SYSTEM 'OFF- HEAT -AUTO-
COOL' AND FAN 'ON -AUTO' S/S
( *) ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF=
SUMMER: 95' F DRY BULB
WINTER= 44° F DRY BULB
(u) MINIMUM VALUE TO MEET ENERGY CODE
HANGER
TO STRUCT
DUCT
CEILING
CONTROL
3/4' DEEP X 1/8' -�
POWERED ACTUATED,
PINS.
CEILING-) GRILLE) JOIST
FLEX. DUCT . UP TO
TOILET EXHAUST FAN DETAIL DES ITN ORIG'
N.T.S.
DIRECTION OF
AIR FL ^'"'
14 (4'MIN.)
?ANCH DUCT
BRANCH DUCT CONNECTION
N.T.S.
OR CONCRETE
SLEEVE
WALL CAP W/ BUILT
E /AIR DUCT - _DAMPER AND BIRD SCREEN
NOTE BIRD SCREEN MUST BE AVOID
TAPE AND SEALER FOR DRYER WALL CAP
ALL AROUND SILICONE CAULK
ALL AROUND
WALL CAP MOUNTING DETAIL
N.T.S.
CONDENSING
UNIT
2 \'X2 \•XI /4'GALV
ANGLE TYP. OF 4
(TWO PER SIDE)
CONCRETE BASE
W /6X6-10 /10 WWF
1/2" MEGH. EXPANSION 4
GALVANIZED ANCHOR
BOLTS
MINIMUM EMBEDMENT 4"
MIN.
WTYPE OF DIFFUSER
A 1 W DIRECTION OF FLOW
6x6
� cJ O SIZE OF DIFFUSER
AMOUNT OF CFM
AIR OUTLET TAG
N.T.S.
I•WIDEX22GA
STRAP o 8'-0 O/C
PINS.
..i6n_ .. 28 GA
G.M. STRIP AT
SUPPORT.
DUCT HANGER DETAIL
N.T.S.
HVAC DESIGN REQUIRES:
AC LEGEND
NO
24X24 CD -(SEE SCHEDULE)
COLLAR CONNECTION TO
MAIN
DUCT TO MATCH NECK SIZE TYP.
ry
CEILING GRILLE SEE SIZE SCHEDULE
X
DUCT TO MATCH NECK SIZE TYP.
Q
RETURN AIR GRILLE -(SEE SCHEDULE)
FIRE RATED ENCLOSURE
�.0
ALL ELBOWS MUST BE PROVIDED WITH
FIRE RATED ROOF /FLOOR CEILING ASSEMBLY
�--(
TURNING VANES
a
MANUAL VOLUME DAMPER
Q
THERMOSTAT
AIR FLOW DIRECTION (ARROWS DENOTE
_ _
1 WAY, 2 WAY, ETC., SEE PLANS
�-�- RETURN OR EXHAUST, SEE PLANS.
WALL MOUNTED SIDE REGISTER,
L�J
EXHAUST FAN
OA/.
OUTSIDE AIR INTAKE
SR
SIDE REGISTER
CP
CEILING DIFFUSER
AC
AIR CONDITIONING UNIT
Cu
CONDENSING LNIT
3/4' DEEP X 1/8' -�
POWERED ACTUATED,
PINS.
CEILING-) GRILLE) JOIST
FLEX. DUCT . UP TO
TOILET EXHAUST FAN DETAIL DES ITN ORIG'
N.T.S.
DIRECTION OF
AIR FL ^'"'
14 (4'MIN.)
?ANCH DUCT
BRANCH DUCT CONNECTION
N.T.S.
OR CONCRETE
SLEEVE
WALL CAP W/ BUILT
E /AIR DUCT - _DAMPER AND BIRD SCREEN
NOTE BIRD SCREEN MUST BE AVOID
TAPE AND SEALER FOR DRYER WALL CAP
ALL AROUND SILICONE CAULK
ALL AROUND
WALL CAP MOUNTING DETAIL
N.T.S.
CONDENSING
UNIT
2 \'X2 \•XI /4'GALV
ANGLE TYP. OF 4
(TWO PER SIDE)
CONCRETE BASE
W /6X6-10 /10 WWF
1/2" MEGH. EXPANSION 4
GALVANIZED ANCHOR
BOLTS
MINIMUM EMBEDMENT 4"
MIN.
WTYPE OF DIFFUSER
A 1 W DIRECTION OF FLOW
6x6
� cJ O SIZE OF DIFFUSER
AMOUNT OF CFM
AIR OUTLET TAG
N.T.S.
I•WIDEX22GA
STRAP o 8'-0 O/C
PINS.
..i6n_ .. 28 GA
G.M. STRIP AT
SUPPORT.
DUCT HANGER DETAIL
N.T.S.
HVAC DESIGN REQUIRES:
YES
NO
DUCT SMOKE DETECTOR
COLLAR CONNECTION TO
MAIN
X
FIRE DAMPER(S)
X
SMOKE DAMPERS)
X
FIRE RATED ENCLOSURE
SUPPLY DUCT SIZE
I AS SHOWN ON PLANS
I
X
FIRE RATED ROOF /FLOOR CEILING ASSEMBLY
X
FIRE STOPPING
X
SMOKE CONTROL
X
PACK VOIDS W /ARMAFLEX E
COAT W /SILICONE SEALANT
FOR TIGHT CLOSURE. HARD TUBING
SOFT TUBING
CONCRETE SLAB
j
a °
a °
V
REFRIGERANT LINES UP
THRU CONCRETE SLAB.
PVC CONDUIT -RUN UNDER SLAB
SEE FLOOR PLAN FOR LOCATION.
(SCI. 40 W /SOLVENT WELD JOINTS.)
USE 4' OR 6' CONDUIT AS REQUIRED.
REFRIGERANT LINE CONDUIT DETAIL
N.T.S.
NOTES:
I. CONCEALED OR NON REMOVABLE JOINTS SHALL NOT
BE INSTALLED BELOW THE SLAB.
2. P.V.C. SCH. 40 SLEEVE SHALL BE 2• LARGER THAN
THE PIPE INSULATION ENCASED, HAVING AN ANGLE
NO GREATER THAN 45 DEGREES WITH THE ENCASED
REFRIGERANT PIPING. REMOVABLE FOR REPLACEMENT.
1/8' STAINLESS STEEL WIRE
WRAP ARROUND CONDENSING UNIT
( DADE COUNTY ORDINANCE 86 -5).
POWER E CONTROL
/- LOCATION
NOTE. SUCTION LINE
SEAL ENTRANCE OF REFRIGERANT W/ 1/2 Al2MAFLEX
LINES INTO PVC PIPE W /IMPERMEABLE, INSULATION E VAPOR
RESILIENT MATERIAL (SEE DETAIL). BARRIER
1/2' BOLTS AND NUTS
C.U. MOUNTING DETAIL
N.T.S.
LIQUID LINE W/ 0
INSULATION
NOTES:
I. INSTALL CONDENSING UNIT EITHER ABOVE THE BASE
FLOOD ELEVATION LEVEL OR PROTECTED SO AS TO
PREVENT WATER FROM ENTERING OR ACCUMULATING
WITHIN THE CONDENSING UNIT DURING FLOODS UP TO
THE BASE FLOOD ELEVATION.
21NSTALLATION MUST MEET MINIMUM OF 146 MPH WIND
LOADING. MIN. REQUIREMENTS ARE HEREBY INDICATED
HOWEVER BASED ON ACTUAL EQUIPMENT INSTALLED
EPA (EFFECTIVE PROJECTED AREA) ADDITIONAL
SECURING SHALL BE PROVIDED
RIGID DUCT UP
TO 29' WITH
OR 16' DEEP.
EX28GA
G.M. STRIP AT
SUPPORT.
UPPER ATTACHMENT
PER SMACNA.
FLEXIBLE DUCT
6MIN- 10'MAX
LENGTH
MAXIMUM D/8 OFFSET
ALLOWED IN LAST
F IVAC GENERAL NOTES = - - - - - -
I. THE CONTRACTOR SHALL FURNISH ALL LkeOP„^MATERIALS A�0 EQUIPMENT-
NECESSARY FOR THE REVISIONS TO NEW HVAC SYSTEM IN - - -
ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE
FLORIDA BUILDING CODE 2001, ALL OTHER APPLICABLE STATE,
COUNTY AND LOCAL ORDINANCES AND THE LATEST EDITION OF THE
FOLLOWING PUBLICATIONS: A) ANS B -9.1 MECHANICAL REFRIGERATION,
B) NFPA PAMPHLETS 90A, 90B AND 91, C) SMACNA, D) ASHRAE, E) OSHA AND
THE STANDARD OF CONSTRUCTION ESTABLISHED BY THE EXISTING
INSTALLATION.
2 THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL
OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS
VVUk'K. Uf•'UN r -ANAL AUUL2` 1 ANU=, A Ur-K I IrIUA I C P-KUM I HC LUUAL
INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER.
3. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH
THE LOCATION OF EXISTING EQUIPMENT, DUCTWORK, PIPING, CONDUITS, P.E. No. 57468
ETC., AND /OR ANY CONDITION THAT MAY AFFECT HIS WORK. ALL David Guirola
NECESSARY RE- ROUTING, RE- LOCATING AND /OR REMOVAL OF EXISTING Electrical Engineer
EQUIPMENT, DUCTWORK, PIPING, ETC., SHALL BE INCLUDED IN THE SCOPE
OF WORK. ALL MATERIALS USED MUST BE EQUAL TO EXISTING SO 8844 N FLORIDA 33182 136 PL
INTEGRITY OF THE INSTALLATION IS NOT CHANGED. P.H: (305) 498 9352
CA 00009112 EMAIL: OUIRO WOLCOM
4. ALL MATERIAL AND EQUIPMENTS SHALL BE NEW, OF U.S. MANUFACTURER
AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE REVISIONS /COMMENTS:
FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK.
ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE
MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN.
5. CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES, SPECIALLY
WITH THE EXISTING LOCATION OF STRUCTURAL MEMBERS.
6. NEW THERMOSTATS SHALL BE COMBINATION COOLING/HEATING, WITH
SYSTEM 'COOL -AUTO- HEAT -OFF AND FAN 'ON-AUTO' SELECTOR SWITCHES.
USE HONEYWELL OR APPROVED EQUAL.
7. UNLESS OTHERWISE NOTED, FAN COIL UNITS SHALL BE MOUNTED HUNG
FROM THE STRUCTURE MEMBERS ABOVE WITH VIBRATION ISOLATORS. -- -- --
CONDENSING UNIT SHALL BE PROPERLY ANCHORED TO THE CONCRETE PAD
TO WITHSTAND HL221CANE FORCE WINDS.
8. REFRIGERANT PIP INSULATION 3/4' FOAMED PLASTIC INSULATION SHALL
BE PROVIDED FOR SUCTION LINES, WITH APPROVED PROTECTIVE FINISH
WHEN EXPOSED TO WEATHER. FIRE RATING NOT TO EXCEED 25 FOR FLAME
SPREAD AND 50 FOR FLEL CONTRIBUTED AND SMOKE DEVELOPED
MANUFACTURER ARMAFLEX OR APPROVED EQUAL.
9. REFRIGERANT PIPING SHALL BE COPPER, TYPE L HARD DRAWN (ASTM -8-88)
WITH WROUGHT COPPER, SOLDER JOINT TYPE FITTINGS. USE 95/5 SOLDER.
REFRIGERANT PIPING SHALL BE SIZED IN ACCORDANCE WITH EQUIVALENT
PIPE LENGTH FOR PRESSURE DROP EQUIVALENT TO ONE DEGREE ui
FAHRENHEIT. 1/2' FOAMED PLASTIC INSULATION SHALL BE PROVIDED FOR Q
SUCTION LINES, WITH APPROVED PROTECTIVE FINISH WHEN EXPOSED TO
WEATHER. FILTER /DRYER AND SIGHTGLASS SHALL BE PROVIDED AT LIQUID O co
LINES.
U
10. CONTRACTOR SHALL BE RESPONSIBLE TO TEST E BALANCE THE HVAC T
SYSTEM AS PER ASSOCIATED AIR BALANCE COUNCIL STANDARDS. % -� , co
II. CONTRACTOR SHALL PRINT UP INSTRUCTIONS FOR OWNER'S OPERATION OF /f/' \ •
SYSTEM, STATING THE ITEMS COVERED BY HIS GUARANTEE AND THE
EQUIPMENT MANUFACTURER'S GUARANTEE.
I�
i
z2 I W
LL
1 S-
0 c
EXHAUST VENTS AND DUCT NOTES %� Q z CO G
I. CLOTHES DRYER EXHAUST DUCT SHALL 'NOT' BE SCREENED. •, ;• U
2. CLOTHES DRYERS EXHAUST DUCTS (OR VENTS) SHALL COMPLY WITH
MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A I V )
MIN. 26 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH Q O
JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCT JOINTS O
SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER
FASTENERS WHICH WOULD EXTEND INTO THE DUCT. W Q !�^
Q
0
rr
ROUND SPIN -IN COLLAR
DUCT SEALER AT SPIN
Q
MOUNT IN SIDE OF DUCT
UNLESS SPECIFICALLY
COLLAR CONNECTION TO
MAIN
SHOWN OTHERWISE
ADJUSTABLE CLAMP
MAX. SAG 1/2' PER FOOT
SUPPLY DUCT SIZE
I AS SHOWN ON PLANS
I
POINTS
D INCHES TO DEVICE `- SEE NOTE 3
WHERE D IS THE ADJUSTABLE CLAMP
INTERNAL FLEX
DIAMETER DUCT SEALER
NECK SIZE TO INSULATE TOP PANEL OF
MATCH FLEX LAY -IN DIFFUSER. SEAL INSULATION
DUCT SIZE TO DIFFUSER- NOT TO T -BAR GRID
INDICATED
1�
CEILING L AIR DISTRIBUTION DEVICE, SEE
(T-BAR SHOWN, SCHEDULE. (LAY -IN SHOWN,
GYP -BOARD SIMILAR). SURFACE MOUNT SIMILAR).
FLEXIBLE DUCT DETAIL
VOLUME DAMPER WITH LOCKING
QUADRANT AND 2' STANDOFF
24" X 24'
CEILING ACCESS PANEL
FOR DAMPER ACCESS IN
NON- ACCESSIBLE CEILINGS.
NTS
FLEXIBLE DUCT NOTES
I. FLEXIBLE DUCTS SHALL BE ONE -PEICE AND SHALL NOT BE SPLICED TOGETHER
2 EXTEND FLEXIBLE DUCT INSULATION TO DUCT /DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC
3. MINIMUM 1" WIDE 22 GALVANIZED STRAP HANGER WITH HEMMED EDGES PER SMACNA, FIGURE 3 -10
4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW RADIUS NO
LESS THAN R/D - 1.0.
SEAL:
J -
DAVID GUIROLA - PE 57468 -'
SHEET TITLE:
JOB NO.: SHEET NO.
2005 -12 CARBONELL
PERMIT SUBMITTAL DATE:
DATE PRINTED:
5/24/05 M-2
SCALE:
AS NOTED