05-1454-008G E N E R A L S T R U C T U R A L N O T E S 01003 DIMENSIONS AND CONDITIONS: All dimensions and conditions shall be verified by the contractor in the field prior to construction. Any discrepancies shall be brought to the immediate attention of the Architect. Written dimensions take precedence over scale at all times. Scale is for guideline purposes only. If dimensions are unclear, do not scale. Request clarification from the Architect or Engineer. 01004 METHODS & SAFETY: The contractor shall be responsible for all methods, procedures, and sequences of construction. Construction site safety, including all adequate temporary bracing and shoring, is the sole responsibility of the contractor. 01006 CONSTRUCTION LOADS: It is the responsibility of the contractor to employ the necessary professional services to determine the necessary methods and supports regarding forming and construction loads. 01007 CONFLICTS IN DOCUMENTS: If conflicts occur in or between architectural and engineering documents, between documents and field conditions or otherwise, the contractor shall immediately contact the Architect for clarification and direction before proceeding. The contractor shall coordinate all dimensions between architectural and structural drawings prior to proceeding with the work. 01008 COORDINATION: The contractor shall coordinate the structural work with the work of all other trades. 01009 MANDATORY INSPECTIONS: The contractor shall assure that the "Mandatory Inspections" as required by the F.B.C. are performed by both the municipal inspector and the Special Inspector (as required), and that the work is accepted prior to continuing with subsequent work. 01010 SHOP DRAWINGS: a. The contractor shall submit to the architect complete shop drawings as required by these notes. b. Review and approval of shop drawings is for the design concept only. The contractor shall check and approve the shop drawings for compliance and completeness before submittal. Approval by the engineer or architect is not for the purpose of approving changes or substitutions. The contractor shall be responsible for all dimensions, quantities, job conditions, and coordination with all documents and other trades. 02000 POLYETHYLENE SHEET: Polyethylene sheet, placed continuously, under concrete slabs and beams placed on ground shall be minimum 6 mil. thick. All joints shall be lapped minimum 12 inches and continuously taped with minimum of two -inch wide vinyl tape. Polyethylene sheet shall extend one inch on to stem wall. 02300 GEOTECHNICAL ENGINEER AND ALLOWABLE SOIL BEARING CAPACITY: a. The footings, indicated in these drawings, have been designed based on an assumed allowable soil bearing capacity of 2,000 psf. Contractor shall engage a Florida registered geotechnical engineer and certified testing laboratory to perform soil exploration and testing and to prepare recommended soil preparation procedures to achieve a minimum allowable soil bearing capacity of 2,000 psf within acceptable limitations for differential settlement. b. Geotechnical engineer shall monitor all phases of soil preparation and backfilling and certify that his /her recommendations have been executed and that the allowable soil bearing capacity is at least 2,000 psf. c. In -place soil density tests shall be taken for the exposed surface of compacted existing soil and each subsequent layer of compacted backfill. Geotechnical engineer shall verify compliance with his /her recommendations. d. All areas of new construction shall be treated for termites per FBC section 1816. 02301 SOILS PREPARATION: a. All soil preparations shall be conducted in accordance with the geotechnical engineer's recommendations. b. As a minimum, all areas of new construction shall be stripped of existing construction to be removed and other deleterious material. Where required, the existing soil shall be excavated to the bottom of proposed footing elevation. The entire area shall be thoroughly compacted by at least eight passes of a vibrating plate compactor to achieve a minimum of 95 percent of maximum density as determined in accordance with ASTM D1557. Each layer of backfill shall not exceed eight inches in thickness and shall be compacted and tested as described above. 03300 CONCRETE (CAST -IN- PLACE): a. Standards: ACI 318 -02, ACI 301 -99 and ACI 347R -94. b. All concrete shall be proportioned to attain a minimum compressive strength of 3000 psi at 28 days. Slump shall be 4" (+1") and no water shall be added to the concrete at the site. Maximum water content shall be 33 gallons per cubic yard. Concrete for areas which will remain exposed to weather after construction shall have 3 to 5 percent entrained air. c. The contractor shall contract an independent testing laboratory to perform the concrete cylinder tests as required by section 1923.2 of the Florida Building Code. d. Contractor shall provide all forming and temporary shoring. e. No pipes or conduits exceeding 1/3 the slab thickness in outside diameter shall b e embedded in the concrete floor without the written approval from the engineer. Where pipes or conduits are permitted, they shall be placed no closer than three diameters on center. and shall be located so as not to impair the strength of the structure. f. Reinforcement: ASTM A615, grade 60, ASTM A185 for welded wire fabric. Splice all column bars to dowels minimum 30 bar diameters (u.o.n). Splice #5 bars in grouted cells a minimum of 30 inches. g. Concrete cover over reinforcement: 1. 3- inches where cast against earth. 2. 2- inches for columns and beams and 1-1/2 inches for slabs where cast in forms or on polyethylene sheet and permanently exposed to weather or earth. 3. 1-1/2 inches at all other locations (u.o.n.). h. Saw -cut control joints shall be made within twelve hours of concrete placement. i. All concrete shall be finished as appropriate for the finishes indicated in the architectural drawings. j. All concrete shall be cured for minimum of seven days. The curing shall entail maintenance of the moisture in the concrete. Generally this shall be accomplished by treating exposed concrete surfaces with a chemical curing compound immediately after finishing and immediately after removal of forms. Forms shall be kept moist by frequent water spraying prior to removal. Verify compatibility of curing compound with proposed finishes. 04420 REINFORCED MASONRY: a. Hollow concrete masonry units shall comply with ASTM C90 "Standard Specifications for Hollow Load Bearing Concrete Masonry Units." b. In accordance with section 2122.4 of the FBC, a Florida Registered Architect or Professional Engineer shall inspect reinforced masonry. c. Mortar shall comply with ASTM C270, type M or S. d. All reinforced CMU walls shall have galvanized steel horizontal joint reinforcement (standard no. 9, ladder type) at every other course. Extend reinforcement minimum 4- inches into all columns. e. Grout shall be 3000 psi concrete grout conforming to the requirements of ASTM C476. Slump shall be 9" (+ 1 f. Reinforced masonry shall comply with the requirements of section 2122 of the FBC and ACI 530 -95 /ASCE 5 -95. g. Reinforced concrete prism strength shall be f'm = 2,000 psi, and shall be verified by tests in accordance with section 2122.5 of the FBC. h. Reinforcement bars shall comply with ASTM A615, grade 60. Lap splice reinforcement in grout - filled cells minimum 48 -bar diameters (minimum 12- inches). i i. Whenever anchor bolts are to be set in masonry, two adjacent cells shall be filled with concrete grout. j. Sills: unless otherwise framed in concrete, provide 8 x 8 concrete (formed or bond -beam block) with 2 #5 mid -depth at all sills. Extend reinforcement minimum 6" into adjacent column or reinforced cell. Equivalent Cast -Crete sills are acceptable (submit shop drawings). k. Lintels: any CMU wall openings, which are not otherwise framed with concrete, shall have 8" x 8" concrete lintels with 2 #5 bottom. Extend reinforcement minimum 6" past opening and cast lintel with minimum 8" bearing on adjacent column or reinforced cell. Equivalent Cast -Crete lintels are acceptable (submit shop drawings). 05120 STRUCTURAL STEEL: a. Materials: 1. Structural tubing: ASTM A500, grade b. 2. All other structural steel: ASTM A36. 3. Anchor bolts: ASTM A307. 4. All other bolts: ASTM A325. b. Shop drawings: submit complete shop drawings for structural steel. c. Standards: 1. AISC "specifications for the design, fabrication and erection of structural steel buildings." 2. AWS D1 -1, E -70 series electrodes. d. Connections: any structural steel connections which are not detailed on these drawings shall be designed in accordance with AISC specifications. e. Corrosion control: all structural steel, shall be shop painted with rust - inhibitive primer. Primer shall be touched up after erection. 05500 FASTENERS: a. Fasteners shall be of the type and size indicated on this drawing. b. All fasteners, including expansion anchors, sleeve anchors, straps, nails, screws, etc. shall be galvanized. 06100 STRUCTURAL LUMBER: a. All structural lumber shall be southern pine, minimum grade no. 2. b. Minimum allowable bending stress (fb): 1. 2x4: 1500 psi 2. 2x6: 1250 psi 3. 2x8: 1200 psi 4. 2x10: 1050 psi 5. 2x12: 975 psi c. All lumber in shall be isolated from concrete or masonry with roofing felt paper. Do not use pressure treated wood unless otherwise noted. 06110 PLYWOOD ROOF SHEATHING: a. Plywood roof sheathing shall be 19/32 ", exterior grade, sheathing, with 32/16 APA span rating. ' b. Extent of diaphragm wood roof blocking required is indicated with hatching on roof plan. Blocking shall consist of solid 2x4 members at panel joints with (2) 16d toe nails at each end. Nail sheathing to blocking as required in note d. below. c. Lay panels, continuous over two or more spans and with face grain perpendicular to primary framing members. End joints shall occur at center of primary framing member with both panels fastened to it. End joints shall be staggered d. Fasten plywood roof sheathing panels to all supporting members using 10d nails. Nail spacing shall be as follows: ALL ROOFS - 4" o.c. at panel perimeter and 6" o.c. in- field. e. Soffit sheathing shall be 7/16 ", exterior grade, APA rated sheathing. Fasten with 8d nails at 6" on center at all supports. 06176 PREFABRICATED WOOD TRUSSES AND GIRDERS: a. Prefabricated wood trusses and girders shall be designed in accordance with ASCE 7 -98 wind loads at 146 mph, building category 2, and exposure C for components and cladding. b. Prefabricated wood trusses and girders shall be designed, fabricated and erected in accordance with the TPI -95 and the FBC for the loads indicated above. c. Prefabricated trusses and girders shall be designed by a Florida registered specialty engineer. Complete calculations and shop drawings shall be signed and sealed by the specialty engineer and submitted to the engineer -of- record for review. Review by the engineer -of- record will be for compliance with design concept only. Specialty engineer shall comply with chapter 471 F.S. d. Truss manufacturer is responsible for the design and fabrication of trusses, girders and their connections to each other. Design of bracing for individual truss or girder members to resist lateral buckling under gravity or wind loads is the responsibility of the truss manufacturer. e. Truss and girder layout as indicated on the roof framing plan(s) shall not be altered without prior written authorization from the engineer -of- record. f. Submit a minimum of (5) signed and sealed copies for review and record. #3 BEAM STIRRUPS (SEE PLAN AND SCHEDULE) TOP AND BOTT. BEAM REINF. (SEE PLAN AND SCHEDULE) 5 DIAGONAL BARS ENT AS SHOWN BOTH FACES)(TYP.) TS STEEL COLUMN SEE PLAN i X, DETAIL AT STEEL COLUMN SEE ARCHITECTURAL DWGS. FOR FOR ARCH DIMENSIONS AND LAYOUT TYPICAL ARCH DETAILS 3/4" = 1' -0" 3' STEEL BUCI x 5" WIDE SIDE I LAIES, 1/2" THICK x 5 WIDE BOTTOM AND BACK PLATES. WELD ALL TOGETHER WITH 3/16" FILLET WELDS ALL AROUND CONNECTION(M)DETAIL 3/4" = 1' -0" BEAM SCHEDULE 01000 CODES: SIZE (INCHES) T.O.B. ELEVATION REINFORCEMENT STIRRUPS All work shall conform to the 2001 edition of the Florida Building Code , (FBC), and all other TB -1 applicable local codes. +10'- 6 2 #5 2 #5 2 #5 01001 DESIGN CRITERIA: TIE BEAM TB -2 8" x 48" +13' -3" a. Roof loads: -- 2 #5 BAL. ® 148" O.C.E ; TIE BEAM Live Load 20 psf for roofs sloped greater than 1.5:12. -- 2 #5 30 psf for flat roofs B -1 8" x 20 "( *) Dead Load 25 psf 2 #5 2 #5 #3 ® 8" o.c. d. Wind Loads: In accordance with ASCE 7 -98 [building category 2; 146 mph wind speed; exposure C; 2 #5 importance factor I = 1.00]. See calculations and roof plan for additional information. #3 @ 12" O.C. 01002 ELEVATION DATUM: 9-3 8" x 34" +10' -6" 2 #5 All elevations on these structural drawings refer to 0' -0" = finish grand floor (See architectural drawings for N.G.V.D.) 01003 DIMENSIONS AND CONDITIONS: All dimensions and conditions shall be verified by the contractor in the field prior to construction. Any discrepancies shall be brought to the immediate attention of the Architect. Written dimensions take precedence over scale at all times. Scale is for guideline purposes only. If dimensions are unclear, do not scale. Request clarification from the Architect or Engineer. 01004 METHODS & SAFETY: The contractor shall be responsible for all methods, procedures, and sequences of construction. Construction site safety, including all adequate temporary bracing and shoring, is the sole responsibility of the contractor. 01006 CONSTRUCTION LOADS: It is the responsibility of the contractor to employ the necessary professional services to determine the necessary methods and supports regarding forming and construction loads. 01007 CONFLICTS IN DOCUMENTS: If conflicts occur in or between architectural and engineering documents, between documents and field conditions or otherwise, the contractor shall immediately contact the Architect for clarification and direction before proceeding. The contractor shall coordinate all dimensions between architectural and structural drawings prior to proceeding with the work. 01008 COORDINATION: The contractor shall coordinate the structural work with the work of all other trades. 01009 MANDATORY INSPECTIONS: The contractor shall assure that the "Mandatory Inspections" as required by the F.B.C. are performed by both the municipal inspector and the Special Inspector (as required), and that the work is accepted prior to continuing with subsequent work. 01010 SHOP DRAWINGS: a. The contractor shall submit to the architect complete shop drawings as required by these notes. b. Review and approval of shop drawings is for the design concept only. The contractor shall check and approve the shop drawings for compliance and completeness before submittal. Approval by the engineer or architect is not for the purpose of approving changes or substitutions. The contractor shall be responsible for all dimensions, quantities, job conditions, and coordination with all documents and other trades. 02000 POLYETHYLENE SHEET: Polyethylene sheet, placed continuously, under concrete slabs and beams placed on ground shall be minimum 6 mil. thick. All joints shall be lapped minimum 12 inches and continuously taped with minimum of two -inch wide vinyl tape. Polyethylene sheet shall extend one inch on to stem wall. 02300 GEOTECHNICAL ENGINEER AND ALLOWABLE SOIL BEARING CAPACITY: a. The footings, indicated in these drawings, have been designed based on an assumed allowable soil bearing capacity of 2,000 psf. Contractor shall engage a Florida registered geotechnical engineer and certified testing laboratory to perform soil exploration and testing and to prepare recommended soil preparation procedures to achieve a minimum allowable soil bearing capacity of 2,000 psf within acceptable limitations for differential settlement. b. Geotechnical engineer shall monitor all phases of soil preparation and backfilling and certify that his /her recommendations have been executed and that the allowable soil bearing capacity is at least 2,000 psf. c. In -place soil density tests shall be taken for the exposed surface of compacted existing soil and each subsequent layer of compacted backfill. Geotechnical engineer shall verify compliance with his /her recommendations. d. All areas of new construction shall be treated for termites per FBC section 1816. 02301 SOILS PREPARATION: a. All soil preparations shall be conducted in accordance with the geotechnical engineer's recommendations. b. As a minimum, all areas of new construction shall be stripped of existing construction to be removed and other deleterious material. Where required, the existing soil shall be excavated to the bottom of proposed footing elevation. The entire area shall be thoroughly compacted by at least eight passes of a vibrating plate compactor to achieve a minimum of 95 percent of maximum density as determined in accordance with ASTM D1557. Each layer of backfill shall not exceed eight inches in thickness and shall be compacted and tested as described above. 03300 CONCRETE (CAST -IN- PLACE): a. Standards: ACI 318 -02, ACI 301 -99 and ACI 347R -94. b. All concrete shall be proportioned to attain a minimum compressive strength of 3000 psi at 28 days. Slump shall be 4" (+1") and no water shall be added to the concrete at the site. Maximum water content shall be 33 gallons per cubic yard. Concrete for areas which will remain exposed to weather after construction shall have 3 to 5 percent entrained air. c. The contractor shall contract an independent testing laboratory to perform the concrete cylinder tests as required by section 1923.2 of the Florida Building Code. d. Contractor shall provide all forming and temporary shoring. e. No pipes or conduits exceeding 1/3 the slab thickness in outside diameter shall b e embedded in the concrete floor without the written approval from the engineer. Where pipes or conduits are permitted, they shall be placed no closer than three diameters on center. and shall be located so as not to impair the strength of the structure. f. Reinforcement: ASTM A615, grade 60, ASTM A185 for welded wire fabric. Splice all column bars to dowels minimum 30 bar diameters (u.o.n). Splice #5 bars in grouted cells a minimum of 30 inches. g. Concrete cover over reinforcement: 1. 3- inches where cast against earth. 2. 2- inches for columns and beams and 1-1/2 inches for slabs where cast in forms or on polyethylene sheet and permanently exposed to weather or earth. 3. 1-1/2 inches at all other locations (u.o.n.). h. Saw -cut control joints shall be made within twelve hours of concrete placement. i. All concrete shall be finished as appropriate for the finishes indicated in the architectural drawings. j. All concrete shall be cured for minimum of seven days. The curing shall entail maintenance of the moisture in the concrete. Generally this shall be accomplished by treating exposed concrete surfaces with a chemical curing compound immediately after finishing and immediately after removal of forms. Forms shall be kept moist by frequent water spraying prior to removal. Verify compatibility of curing compound with proposed finishes. 04420 REINFORCED MASONRY: a. Hollow concrete masonry units shall comply with ASTM C90 "Standard Specifications for Hollow Load Bearing Concrete Masonry Units." b. In accordance with section 2122.4 of the FBC, a Florida Registered Architect or Professional Engineer shall inspect reinforced masonry. c. Mortar shall comply with ASTM C270, type M or S. d. All reinforced CMU walls shall have galvanized steel horizontal joint reinforcement (standard no. 9, ladder type) at every other course. Extend reinforcement minimum 4- inches into all columns. e. Grout shall be 3000 psi concrete grout conforming to the requirements of ASTM C476. Slump shall be 9" (+ 1 f. Reinforced masonry shall comply with the requirements of section 2122 of the FBC and ACI 530 -95 /ASCE 5 -95. g. Reinforced concrete prism strength shall be f'm = 2,000 psi, and shall be verified by tests in accordance with section 2122.5 of the FBC. h. Reinforcement bars shall comply with ASTM A615, grade 60. Lap splice reinforcement in grout - filled cells minimum 48 -bar diameters (minimum 12- inches). i i. Whenever anchor bolts are to be set in masonry, two adjacent cells shall be filled with concrete grout. j. Sills: unless otherwise framed in concrete, provide 8 x 8 concrete (formed or bond -beam block) with 2 #5 mid -depth at all sills. Extend reinforcement minimum 6" into adjacent column or reinforced cell. Equivalent Cast -Crete sills are acceptable (submit shop drawings). k. Lintels: any CMU wall openings, which are not otherwise framed with concrete, shall have 8" x 8" concrete lintels with 2 #5 bottom. Extend reinforcement minimum 6" past opening and cast lintel with minimum 8" bearing on adjacent column or reinforced cell. Equivalent Cast -Crete lintels are acceptable (submit shop drawings). 05120 STRUCTURAL STEEL: a. Materials: 1. Structural tubing: ASTM A500, grade b. 2. All other structural steel: ASTM A36. 3. Anchor bolts: ASTM A307. 4. All other bolts: ASTM A325. b. Shop drawings: submit complete shop drawings for structural steel. c. Standards: 1. AISC "specifications for the design, fabrication and erection of structural steel buildings." 2. AWS D1 -1, E -70 series electrodes. d. Connections: any structural steel connections which are not detailed on these drawings shall be designed in accordance with AISC specifications. e. Corrosion control: all structural steel, shall be shop painted with rust - inhibitive primer. Primer shall be touched up after erection. 05500 FASTENERS: a. Fasteners shall be of the type and size indicated on this drawing. b. All fasteners, including expansion anchors, sleeve anchors, straps, nails, screws, etc. shall be galvanized. 06100 STRUCTURAL LUMBER: a. All structural lumber shall be southern pine, minimum grade no. 2. b. Minimum allowable bending stress (fb): 1. 2x4: 1500 psi 2. 2x6: 1250 psi 3. 2x8: 1200 psi 4. 2x10: 1050 psi 5. 2x12: 975 psi c. All lumber in shall be isolated from concrete or masonry with roofing felt paper. Do not use pressure treated wood unless otherwise noted. 06110 PLYWOOD ROOF SHEATHING: a. Plywood roof sheathing shall be 19/32 ", exterior grade, sheathing, with 32/16 APA span rating. ' b. Extent of diaphragm wood roof blocking required is indicated with hatching on roof plan. Blocking shall consist of solid 2x4 members at panel joints with (2) 16d toe nails at each end. Nail sheathing to blocking as required in note d. below. c. Lay panels, continuous over two or more spans and with face grain perpendicular to primary framing members. End joints shall occur at center of primary framing member with both panels fastened to it. End joints shall be staggered d. Fasten plywood roof sheathing panels to all supporting members using 10d nails. Nail spacing shall be as follows: ALL ROOFS - 4" o.c. at panel perimeter and 6" o.c. in- field. e. Soffit sheathing shall be 7/16 ", exterior grade, APA rated sheathing. Fasten with 8d nails at 6" on center at all supports. 06176 PREFABRICATED WOOD TRUSSES AND GIRDERS: a. Prefabricated wood trusses and girders shall be designed in accordance with ASCE 7 -98 wind loads at 146 mph, building category 2, and exposure C for components and cladding. b. Prefabricated wood trusses and girders shall be designed, fabricated and erected in accordance with the TPI -95 and the FBC for the loads indicated above. c. Prefabricated trusses and girders shall be designed by a Florida registered specialty engineer. Complete calculations and shop drawings shall be signed and sealed by the specialty engineer and submitted to the engineer -of- record for review. Review by the engineer -of- record will be for compliance with design concept only. Specialty engineer shall comply with chapter 471 F.S. d. Truss manufacturer is responsible for the design and fabrication of trusses, girders and their connections to each other. Design of bracing for individual truss or girder members to resist lateral buckling under gravity or wind loads is the responsibility of the truss manufacturer. e. Truss and girder layout as indicated on the roof framing plan(s) shall not be altered without prior written authorization from the engineer -of- record. f. Submit a minimum of (5) signed and sealed copies for review and record. #3 BEAM STIRRUPS (SEE PLAN AND SCHEDULE) TOP AND BOTT. BEAM REINF. (SEE PLAN AND SCHEDULE) 5 DIAGONAL BARS ENT AS SHOWN BOTH FACES)(TYP.) TS STEEL COLUMN SEE PLAN i X, DETAIL AT STEEL COLUMN SEE ARCHITECTURAL DWGS. FOR FOR ARCH DIMENSIONS AND LAYOUT TYPICAL ARCH DETAILS 3/4" = 1' -0" 3' STEEL BUCI x 5" WIDE SIDE I LAIES, 1/2" THICK x 5 WIDE BOTTOM AND BACK PLATES. WELD ALL TOGETHER WITH 3/16" FILLET WELDS ALL AROUND CONNECTION(M)DETAIL 3/4" = 1' -0" BEAM SCHEDULE MARK SIZE (INCHES) T.O.B. ELEVATION REINFORCEMENT STIRRUPS -" "REMARKS TOP INT. BOTT. TB -1 8" x 20" +10'- 6 2 #5 2 #5 2 #5 BAL. @AT 12" O.C.E ; TIE BEAM TB -2 8" x 48" +13' -3" 2 #5 -- 2 #5 BAL. ® 148" O.C.E ; TIE BEAM TB -3 8" x 48" +13' -3" 2 #5 -- 2 #5 BAL. A 148" 48" 0. TIE BEAM B -1 8" x 20 "( *) +10' -6" 2 #5 2 #5 2 #5 #3 ® 8" o.c. ( *) ARCHED BEAM. SEE BELOW B -2 8" x 29 "( *) +10' -6" 2 #5 2 #5 2 #5 #3 @ 12" O.C. ( *) ARCHED BEAM. SEE BELOW COORD. W GARAGE DOOR 9-3 8" x 34" +10' -6" 2 #5 4 #5 2 #5 #3 @ 12" o.c. B -4 10" x 27 "( *) +10' -6" 2 #5 2 #5 2 #5 #3 @ 12" o.c. ( *) ARCHED BEAM. SEE BELOW B -5 8" x 37 "( *) +10' -6" 2 #5 4 #5 2 #5 #3 @ 12" o.c. ( *) ARCHED BEAM. SEE 4/S.02 B -6 8" x 12 "( *) +13' -3" 2 #5 -- 2 #5 #3 @ 4" a. c. ( *) ARCHED BEAM. SEE BELOW B -7 37"x3 8( +13' -3" 2 #5 2 #5 2 #5 #3 @ 6" a. c. ( *) ARCHED BEAM. SEE 4/S.02 L -1 8" x 8" VARIES -- -- 2 #5 NONE AT WINDOW /DOOR HEAD L -2 8" x 12" VARIES 2 #5 -- 2 #5 #3 ® 4" a. c. AT WINDOW /DOOR HEAD BEAM NOTES: 1. AT ALL BEAM- CORNERS AND INTERSECTIONS,- PROVIDE 2 #5 L- SHAPED CORNER BARS WITH 30 -INCH LONG LEGS AT TOP AND BOTTOM. 2. HOOK ALL TOP BARS AT ENDS. 3. ALL TOP AND BOTTOM BARS SHALL BE CONTINUOUS. WHERE NECESSARY, LAP SPLICE TOP BARS IN MIDDLE THIRD OF SPAN AND LAP SPLICE BOTTOM BARS AT SUPPORTS. LAP SPLICE SHALL BE MINIMUM 36- INCHES. 4. COORDINATE ALL MASONRY OPENINGS WITH ARCHITECTURAL DRAWINGS. COLUMN SCHEDULE MARK SIZE REINFORCEMENT REMARKS VERTICAL TIES FC1 8" x 8" 1#5 NONE FILLED CELL. • TC1 8" x 12" 4 #5 #3 @ 8" O.C. TIE COLUMN TC2 8" x 14" 4 #5 #3 @ 8" o.c. TIE COLUMN FMI TC3 8 "x11 "x1 8 "x8" 7 #6 #3 ® 8" a. c. TIE COLUMN OP TC4 8" x 9" 4 #5 #3 @ 4" a. c. TIE COLUMN TC5 8" x 20" 6 #5 #3 ties + hairpins ® 8 o.c. TIE COLUMN COLUMN NOTES: 1. HOOKED DOWELS, SAME SIZE AND NUMBER AS VERTICAL REINFORCEMENT, SHALL BE EMBEDDED TO BOTTOM OF FOOTING BELOW AND SHALL LAP MINIMUM 30 BAR DIAMETERS WITH VERTICAL REINFORCEMENT IN COLUMNS. 2. HOOK ALL VERTICAL COLUMN REINFORCEMENT AT TOP. FOOTING SCHEDULE MARK THICKNESS BOTT. REINFORCEMENT REMARKS SHORT WAY LONG WAY WF -16 16" x CONT. 12" -- 2 #5 WALL FOOTING WF -24 24" x CONT. 12" #4 ® 32" 3 #5 WALL FOOTING WF -36 36" x CONT. 12" #5 @ 48" 3 #5 WALL FOOTING F3.0 36" x 36" 12" 4 #5 4 #5 T.O.F. ELEV -1' -0" BLW FINISH GRID. F60 60" x 60" 12" 6 #5 6 #5 monolithic with wall footing TE -8 8" x CONT. 8" -- 1#5 THICKENED EDGE FOOTING NOTES: P V 2 1. AT ALL FOOTING CORNERS AND INTERSECTIONS, PROVIDE # 5 L -SHAPED CORNER BARS WITH 30 -INCH LONG LEGS. 2. LAP SPLICE BARS MINIMUM 36- INCHES. (4) 3/4" DIAMETER THRU -BOLTS CONCRETE BEAM (SEE PLAN AND SCHEDULE) (3) 3/4" DIAMETER x 6" HOOKED ANCHOR BOLTS BUTT- WELDED TO PLATE COLTRAIN AND JONES ARCHITECTURE, P.A. DESIGN + CADD PRODUCTION CONSTRUCTION ADMINISTRATION BUILDING INSPECTIONS ITEL.(305) 285 -6723 FAX.(305) 285 -6722 11535 SW 8 ST. MIAMI, FL 33130 SUITE 100 REVISIONS /COMMENTS, W U z W C/7 d- W Q r > rll� 0 < LL1 W W z a­ 0 � O o Q < (_0 < f- U� � N CD O � 0 Zzj- Q U.S. Stmeture8, Inc. Structural Engineers 4444 SOUTHWEST,,71st AVENUE SUITE 103 „MiANIhFLORIDA 33155 305.665.4555;, FAX 365.665.5522 email: www.ussbructuresinc1com' CA 8439-/ Jose A. Tol 6, 'r:E.. Structural_Engineer , Florida License ,149. 54391 SHEET TITLE: ^ NOTES AND SCHEDULEES -^ NOTES /DATES: JOB NO.: SHEET NO. CJA 05.001 PERMIT SUBMITTAL DATE: DATE PRINTED: 09/09/05 SCALE: AS NOTED DRAWN BY: E.C. 5.01