Loading...
05-1454-007WINDOW SCHEDULE NO. SIZE WIDTH X HEIGHT MATERIAL TYPE FRAME SILL REMARKS O 37" x 60" ALUM. HORIZ. ROLLER /FIXED ALUM. ALUM. PGT INDUSTRIES CASEMENT, N.O.A.# 02- 0327.04, AND PGT FIXED WINDOW, N.O.A. # 02- 0716.03, BOTH IMPACT RESISTANT O 60" x 48" ALUM. HORIZ. ROLLER ALUM. ALUM. PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT O 48" x 36" ALUM. CASE ALUM. ALUM. PGT INDUSTRIES CASEMENT, N.O.A.# 02- 0327.04, IMPACT RESISTANT O 36" x 24" ALUM. HORIZ. ROLLER ALUM. ALUM. PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT O 36" x 30" ALUM. HORIZ. ROLLER ALUM. ALUM. PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT O 36" x 36" ALUM. HORIZ. ROLLER ALUM. ALUM. PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT © 60" x 108" ALUM. (2) HORIZ. ROLLER ALUM. ALUM. PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT O 48" x 108" ALUM. HORIZ. ROLLER ALUM. ALUM. PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT 0 60" x 36" ALUM. HORIZ. ROLLER ALUM. ALUM. PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT 4' -0" i 2' -0" 2' -0" O I N O I Ln �n, 0 O I I 5' -0" g, -0„ 4' -6" 4' -6" O I LCD ME 3' -0" 2' -0" 2' -6" -- - -i- -- - - - - -- ---------------- - - - - -% � - _.............�.. CD I j- • 0 r IIII O O O V O I LCD O O O WINDOW TYPES SCALE: 3/8" = l'-O" 5' -4" 0 ROOM SIZE MATERIAL ol WALLS THRESHOLD HARDWARE REQUIREMENTS I i FLOOR BASE CEILING NOTES: NORTH EAST SOUTH l 6' -0" x 7' -0" ALUM /GLASS EXT. i >o EXTERIOR HARDWARE & DEAD BOLT too ENTRY TILE TILE STUCCO STUCCO STUCCO STUCCO STUCCO ® 2' -8' x 7'-0' WD INT. WD PAINT PAINT PAINT PAINT PAINT WD tat FOYER TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. WD DOOR PULLS, SELECTED BY OWNER O7 PAINT PAINT • 0 r IIII O O O V O I LCD O O O WINDOW TYPES SCALE: 3/8" = l'-O" 5' -4" 0 „ O EXTERIOR FLUSH SOLID CORE FINISH GRADE WITH IMPACT RESISTANT GLASS N.O.A. ACCEPTANCE #02- 0927.13 2, -4" 0 I O INTERIOR FLUSH SOLID CORE STAIN GRADE DOOR TYPES NOT TO SCALE I 6' -0" 4 0 CD r O r EXTERIOR IMPACT RESISTANT GLASS N.O.A. ACCEPTANCE #01- 1109.03 3' -0" 8' -0" All INTERIOR BI -FOLD HOLLOW CORE STAIN GRADE I 5' -0" AL �k O INTERIOR FLUSH SOLID CORE STAIN GRADE ROOM SIZE MATERIAL ol WALLS THRESHOLD HARDWARE REQUIREMENTS I i ,o I IB I FLOOR BASE CEILING „ O EXTERIOR FLUSH SOLID CORE FINISH GRADE WITH IMPACT RESISTANT GLASS N.O.A. ACCEPTANCE #02- 0927.13 2, -4" 0 I O INTERIOR FLUSH SOLID CORE STAIN GRADE DOOR TYPES NOT TO SCALE I 6' -0" 4 0 CD r O r EXTERIOR IMPACT RESISTANT GLASS N.O.A. ACCEPTANCE #01- 1109.03 3' -0" 8' -0" All INTERIOR BI -FOLD HOLLOW CORE STAIN GRADE I 5' -0" AL �k O INTERIOR FLUSH SOLID CORE STAIN GRADE O INTERIOR DOUBLE BI -FOLD HOLLOW CORE STAIN GRADE 0 1 0 2' -8" INTERIOR FLUSH SOLID CORE STAIN GRADE 3' -0" All CD INTERIOR FLUSH SOLID CORE 1 HR FIRE RATED FINISH NOTES: 1. FINISHES ARE TO BE SELECTED BY OWNER. G.C. TO PROVIDE AND INSTALL. G.C. TO COORDINATE FINISHES W/ OWNER SELECTIONS. 2. PAINT IS TO BE 2 COATS OF BENJAMIN MOORE REGAL INTERIOR PAINT. PAINT COLOR AND FINISH TO BE SELECTED BY OWNER. 3. FLOORING AND BASE TO BE SELECTED BY OWNER. G.C. TO PROVIDE AND INSTALL. WINDOW NOTES: 1. CONTRACTOR SHALL COORDINATE AND VERIFY WITH WINDOW MANUFACTURER'S SHOP DRAWINGS FOR REQUIRED MASONRY OPENING FOR PROPER INSTALLATION BEFORE CONCRETE BLOCK WORK IS STARTED OR TIE COLUMNS ARE POURED. G.C. TO VERIFY WITH WINDOW INSTALLER. WINDOW SIZES ON DRAWINGS ARE NOMINAL DIMENSIONS. 2. INSTALLATION OF WINDOWS SHALL BE IN STRICT ACCORDANCE WITH THE DESIGNATED AND APPROVED METHOD INDICATED IN THE SHOP DRAWINGS AND THE N.O.A. SUBMITTALS AS APPROVED PRODUCT CONTROL PER THE F.B.C. 3. ALL FIXED GLASS PANELS SHALL BE 3116" OR THICKER AS REQ. TO MEET WIND LOAD AND IMPACT REQUIREMENTS. ALL GLASS USED INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C. 4. ALL WINDOWS IN RENOVATION TO BE IMPACT RESISTANT. SEE SHOP DRAWINGS FOR EXACT SPECIFICATIONS. 5. EGRESS TYPE WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL PROVIDE A CLEAR OPENING OF NOT LESS THAN 20" WIDE, 24" HIGH, AND 5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL BE PLACED HIGHER THAN 54" ABOVE THE FLOOR. 6. PROVIDE OPAQUE GLASS AT BATHROOM WINDOW AS PER F.B.C. PROVIDE SAFETY TEMPERED GLASS AS PER F.B.C. FOR WINDOW AND SHOWER ENCLOSURE. DOOR NOTES: 1. CONTRACTOR SHALL COORDINATE AND VERIFY WITH DOOR MANUFACTURER'S SHOP DRAWINGS FOR REQUIRED MASONRY OPENING FOR PROPER INSTALLATION BEFORE CONCRETE BLOCK WORK IS STARTED OR TIE COLUMNS ARE POURED. 2. INSTALLATION OF DOOR ASSEMBLIES SHALL BE IN STRICT ACCORDANCE WITH THE DESIGNATED AND APPROVED METHOD INDICATED IN THE SHOP DRAWINGS AND THE N.O.A. SUBMITTALS AS APPROVED PRODUCT CONTROL PER THE F.B.C. J. ALL FIXED GLASS PANELS SHALL BE 3116" OR THICKER AS REQ. TO MEET WIND LOADS AND IMPACT REQUIREMENTS, SAFETY GLASS. ALL GLASS USED INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C. 4. ALL EXTERIOR DOORS IN RENOVATION TO BE IMPACT RESISTANT. SEE SHOP DRAWINGS FOR EXACT SPECIFICATIONS. ALL EXISTING OPENINGS (IF APPLICABLE) TO BE FIELD VERIFIED PRIOR TO ORDERING DOOR ASSEMBLY. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANEL. 5. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN F.B.C. 6. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. 7. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. FINISH SCHEDULE ROOM SIZE MATERIAL ol WALLS THRESHOLD HARDWARE REQUIREMENTS O INTERIOR DOUBLE BI -FOLD HOLLOW CORE STAIN GRADE 0 1 0 2' -8" INTERIOR FLUSH SOLID CORE STAIN GRADE 3' -0" All CD INTERIOR FLUSH SOLID CORE 1 HR FIRE RATED FINISH NOTES: 1. FINISHES ARE TO BE SELECTED BY OWNER. G.C. TO PROVIDE AND INSTALL. G.C. TO COORDINATE FINISHES W/ OWNER SELECTIONS. 2. PAINT IS TO BE 2 COATS OF BENJAMIN MOORE REGAL INTERIOR PAINT. PAINT COLOR AND FINISH TO BE SELECTED BY OWNER. 3. FLOORING AND BASE TO BE SELECTED BY OWNER. G.C. TO PROVIDE AND INSTALL. WINDOW NOTES: 1. CONTRACTOR SHALL COORDINATE AND VERIFY WITH WINDOW MANUFACTURER'S SHOP DRAWINGS FOR REQUIRED MASONRY OPENING FOR PROPER INSTALLATION BEFORE CONCRETE BLOCK WORK IS STARTED OR TIE COLUMNS ARE POURED. G.C. TO VERIFY WITH WINDOW INSTALLER. WINDOW SIZES ON DRAWINGS ARE NOMINAL DIMENSIONS. 2. INSTALLATION OF WINDOWS SHALL BE IN STRICT ACCORDANCE WITH THE DESIGNATED AND APPROVED METHOD INDICATED IN THE SHOP DRAWINGS AND THE N.O.A. SUBMITTALS AS APPROVED PRODUCT CONTROL PER THE F.B.C. 3. ALL FIXED GLASS PANELS SHALL BE 3116" OR THICKER AS REQ. TO MEET WIND LOAD AND IMPACT REQUIREMENTS. ALL GLASS USED INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C. 4. ALL WINDOWS IN RENOVATION TO BE IMPACT RESISTANT. SEE SHOP DRAWINGS FOR EXACT SPECIFICATIONS. 5. EGRESS TYPE WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL PROVIDE A CLEAR OPENING OF NOT LESS THAN 20" WIDE, 24" HIGH, AND 5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL BE PLACED HIGHER THAN 54" ABOVE THE FLOOR. 6. PROVIDE OPAQUE GLASS AT BATHROOM WINDOW AS PER F.B.C. PROVIDE SAFETY TEMPERED GLASS AS PER F.B.C. FOR WINDOW AND SHOWER ENCLOSURE. DOOR NOTES: 1. CONTRACTOR SHALL COORDINATE AND VERIFY WITH DOOR MANUFACTURER'S SHOP DRAWINGS FOR REQUIRED MASONRY OPENING FOR PROPER INSTALLATION BEFORE CONCRETE BLOCK WORK IS STARTED OR TIE COLUMNS ARE POURED. 2. INSTALLATION OF DOOR ASSEMBLIES SHALL BE IN STRICT ACCORDANCE WITH THE DESIGNATED AND APPROVED METHOD INDICATED IN THE SHOP DRAWINGS AND THE N.O.A. SUBMITTALS AS APPROVED PRODUCT CONTROL PER THE F.B.C. J. ALL FIXED GLASS PANELS SHALL BE 3116" OR THICKER AS REQ. TO MEET WIND LOADS AND IMPACT REQUIREMENTS, SAFETY GLASS. ALL GLASS USED INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C. 4. ALL EXTERIOR DOORS IN RENOVATION TO BE IMPACT RESISTANT. SEE SHOP DRAWINGS FOR EXACT SPECIFICATIONS. ALL EXISTING OPENINGS (IF APPLICABLE) TO BE FIELD VERIFIED PRIOR TO ORDERING DOOR ASSEMBLY. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANEL. 5. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN F.B.C. 6. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. 7. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. FINISH SCHEDULE ROOM SIZE MATERIAL TYPE WALLS THRESHOLD HARDWARE REQUIREMENTS NO. LOCATION FLOOR BASE CEILING NOTES: NORTH EAST SOUTH WEST 6' -0" x 7' -0" ALUM /GLASS EXT. ALUM. >o EXTERIOR HARDWARE & DEAD BOLT too ENTRY TILE TILE STUCCO STUCCO STUCCO STUCCO STUCCO ® 2' -8' x 7'-0' WD INT. WD PAINT PAINT PAINT PAINT PAINT WD tat FOYER TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. WD DOOR PULLS, SELECTED BY OWNER O7 PAINT PAINT PAINT PAINT PAINT DOOR PULLS, SELECTED BY OWNER toe HALL TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT t03 GALLERY TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT toa UTILITY TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT toy GARAGE CONC. _ GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT tos MECHANICAL ROOM CONC. _ GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT toy DINING ROOM TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT 108 MASTER BEDROOM CARPET WOOD GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT PAINT tog WALK —IN CLOSET (W.I.C.) CARPET WOOD GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT PAINT t to HALL CARPET WOOD GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT PAINT t 1 t MASTER BATHROOM TILE TILE TILE TILE TILE TILE M.R. GYP. BD. PAINT 1 t2 SHOWER TILE TILE TILE TILE TILE TILE TILE tt3 HALL TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT tta KITCHEN TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT tts FAMILY ROOM TILE TILE GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT tts BEDROOM 2 CARPET WOOD GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT PAINT tt� BATH 2 TILE TILE TILE TILE TILE TILE M.R. GYP. BD. PAINT t to BEDROOM 3 CARPET WOOD GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT PAINT 1 t9 BATH 3 TILE TILE TILE TILE TILE TILE M.R. GYP. BD. PAINT tz BEDROOM 4 /OFFICE CARPET WOOD GYP. BD. GYP. BD. GYP. BD. GYP. BD. GYP. BD. PAINT PAINT PAINT PAINT PAINT PAINT 12t PORCH TILE TILE STUCCO STUCCO STUCCO STUCCO STUCCO PAINT PAINT PAINT PAINT PAINT DOOR SCHEDULE NO. SIZE MATERIAL TYPE FRAME THRESHOLD HARDWARE REQUIREMENTS REMARKS Oj 3' -0" x 6' -8" ALUM /GLASS EXT. ALUM. EXTERIOR HARDWARE & DEAD BOLT SIDE LIGHTS AND TRANSOM 0 6' -0" x 7' -0" ALUM /GLASS EXT. ALUM. >o EXTERIOR HARDWARE & DEAD BOLT J O3 5' -0" x 7' -0" WD /GLASS INT. DOUBLE DOORS WD INTERIOR HARDWARE UL ® 2' -8' x 7'-0' WD INT. WD � INTERIOR HARDWARE & PRIVACY LOCK U) 0 2' -4" x 7' -0" WD INT. WD INTERIOR HARDWARE & PRIVACY LOCK O 3' -0" x 7' -0" WD INT. BI —FOLD WD DOOR PULLS, SELECTED BY OWNER O7 8' -0" x 7' -0" WD INT. DBL. BI —FOLD WD DOOR PULLS, SELECTED BY OWNER Og 3' -0" x 7' —O" WD INT. WD EXTERIOR HARDWARE & DEAD BOLT 1 HR FIRE RATED TYPE 1: NO THRESHOLD CARPET CARPET 1 TYPE 2: THRESHOLD STONE OR CARPET CONC. THRESHOLD TYPES NOT TO SCALE TYPE 3: NO THRESHOLD CONC. CONC. OR OR STONE STONE 3 TYP E 4: THRESHOLD TILE OR CARPET X STONE TYPE 5: NO THRESHOLD TILE STONE COLTRAIN AND JONES ARCHITECTURE, P.A. DESIGN + CAD PRODUCTION CONSTRUCTION ADMINISTRATION BUILDING INSPECTIONS TEL(305) 285 -6723 FAX.(305) 285 -6722 535 SW 8 ST. SUITE 100 MIAMI, FL 33130 REVISIONS /COMMENTS: W U z w D w UJ cy) z co � >o J Q � z � O UL m(.0 � Q U) � U�= uioo C� ac Q SEAL:- MARK A. COLTRAIN AR 0013380 RICHARD K. JONES, AIA AR 0015755 SHEET TITLE: SCHEDULES NOTES /DATES: JOB NO.: SHEET NO. PERMIT SUBMITTAL DATE: 9/29/05 DATE PRINTED: 02/07/06 —4.1 SCALE: DRAWN BY: M.R.