05-1454-006tun Tnt irrrr+
VE
SECTION THROUGH ARCHED ENTRANCE
SCALE: 3/4" = 1' -0"
F-AKI Rnv IC\ICInF*
5/8" PLYWOOD SHEATHING
(SEE STRUCT. DWGS)
2" x 4" WD. TRUSSES
(SEE STRUCT. DWGS)
HURRICANE STRAP
(SEE STRUCT. DWGS)
USE ONLY TRIPPLE ZINC — G
185 GALVANIZED HANGERS &
STR/9?&VANIZED DRIP EDGE
T.O.B. ELEV. VARIES
SEE ELEVS.
1"X2" WD. PT.
1"X6" FACIA BOARD
6 "x12" PVC TYPE
SCREEN VENT
METAL LATH AND
STUCCO
3/4" STUCCO FINISH
8" CMU WALL
(SEE STRUCT. DWGS)
FINISH GRADE
U-1
0
z
00
IaES
IN
■
i i
■ ■
m .
IN 0
12
4
DESIGNED IN ACCORDANCE_-WITri
FBC 2001 & ASCE 7 =98_ - W
140 MPH WINDS EXPOSURE 'C' -_
R -30 BAT INSUL.
WD. TRUSSES
AT 24" O.C.
+9' -6" CLNG. HEIGHT
1/2" DRYWALL ON 1"X2" P.T
FURRING STRIPS, 16" O.C.
8" x 20" TIE BEAM @ ARCH
WINDOW (SEE STRUCT. DWGS)
NOTE: ALL WOOD MEMBERS
ATTCHED TO CMU OR CONC.
SHALL BE P.T. WOOD
FOAM INSULATION, R -5
1/2" DRYWALL ON 1"X2" P.T
FURRING STRIPS, 16" O.C.
BASE, OWNER TO SELECT
CONTROL JOINT
FLOOR FINISH TO BE SELECTED
AND PROVIDED BY OWNER
G.C. TO INSTALL
/— 4" CONC. SLAB
+0' -8" T.O.S.
N.G.V.D. 10' -8"
6 MIL VAPOR BARRIER
�....— ...!.... -- ..........
........... —' .. —._ . - I.............'...i_— -
1.:f.:1 -11 ! I_Y_I- 95% COMPACTED FILL
---- , -. - -- — _ - - -- , I - - -. ..I WALL FOOTING, SEE
1I I I I STRUCT. DWGS FOR SIZES
AND REBAR SPACING
I;
VAPOR BARRIER:
VAPOR RETARDER CONSISTING OF 6 MIL
MINIMUM POLYETHYLENE WITH JOINTS
LAPPED 6" AND SEALED, INSTALLED
UNDERNEATH THE SLAB. FBC. 1909.2
TYPICAL WALL SECTION
SCALE: 3/4" = 1' -0"
SEE MECH. ENERGY CALCS. FOR
R -VALUE OF WALL
EXTERIOR STUCCO,
FLOAT FINISH
INTERIOR EXTERIOR
8" CMU WITH
#5 REINF. RODS
SEE STRUCT. DWGS.
iN 1 LAYER OF 1/2" GYPSUM BOARD
.S. AND RIGID INSULATION ON MTL
FURRING STRIPS, PAINT
TYPICAL VENT DETAIL - THROUGH OVERHANG
SCALE: 3/4" = 1' -0"
SCHEDULED BASE
FINISH FLOOR, SEE SCHD.
DO NOT FASTEN TOP RUNNERS
DIRECTLY TO TRUSSES!
8' -4' TRUSSES ABOVE
B.O. C. 1/2 "" GYP. BD. CLG.
1" FURRING STRIPS
2 "x4" TOP RUNNER &
FIREBLOCK
------------------ - - - - -- 3 -5/8" WD.
STUD 16" D.C.
1/2" GYP. BD.
2 "x4" WD. @ MIDPOINT FOR
FIREBLOCK /DRAFTSTOP
INTERIC
:RIOR
BOTTOM RUNNER USE P.T
WOOD ON CONCRETE
BASE, BY OWNER
FLOOR FINISH, BY
OWNER, ON CONC. SLAB
TERMITE PROTECTION: APPLIED AT FOUNDATION
PERIMETER AFTER EXCAVATION AND BACK FILLING
AND COMPACTING IS COMPLETE IN ACCORDANCE TO
SECTION 1816.1.3 AND ALL OTHER SUBSECTIONS
RELATED TO TERMITE PROTECTION. COMPLIANCE
SHALL BE ISSUED TO THE BUILDING DEPARTMENT
BY A LICENSED PEST CONTROL COMPANY.
DO NOT FASTEN TOP RUNNERS
DIRECTLY TO TRUSSES!
8'-4" TRUSSES ABOVE
B.O.C.
1/2"" GYP. BD. CLG.
\- 1" FURRING STRIPS
2 "x4" TOP RUNNER &
FIREBLOCK
............ ...........3 -5/8" WD.
STUD 16' O.C.
2 "x6" WD. BLOCKING BETWEEN
STUDS FOR CABINETS
1/2" GYP. BD.
2 "x4" WD. ® MIDPOINT FOR
- FIREBLOCK/DRAFTSTOP
INT RIOR INTERIOR INTERIi
ANCHOR 2 "x6" WD. BLOCKING
BETWEEN STUDS ® ALL
FIXTURE /CABINET LOCATIONS
BOTTOM RUNNER USE P.T
WOOD ON CONCRETE
BASE, BY OWNER
A AL X-1-OWNER, OFON CONC. SLAB
TRUSSES ABOVE
1" FURRING STRIPS
1/2" MR GYP. BD. CLG.
2 "x4" TOP RUNNER &
FIREBLOCK
1/2" GYP. BD.
3 -5/8" WD. STUD
16" O.C.
"HROOM
CERAMIC TILE, BY
OWNER
1/2" DUROCK
BOTTOM RUNNER USE P.T
WOOD ON CONCRETE
CERAMIC TILE
FL. @ BATH
COLTRAIN AND JONES
ARCHITECTURE, P.A.
DESIGN + CAD PRODUCTION
CONSTRUCTION ADMINISTRA11ON
BUILDING INSPECTIONS
TEL(305) 285 -6723 FAX(305) 285 -6722
535 SW 8 ST. SUFE 100 MIAMI, FL 33130
REVISIONS /COMMENTS:
w
U
Z
w
0
w
J
J
ui
0
Z
m
Q
U
i
N
ui
0
Q
SEAL'
w�
r
zCIO
W Q
Q �
�O
J
LL
_Q
O =
O
,
d
hJ
• ,
MARK A. COLTRAIN
AR 0013380
RICHARD K. JONES, AIA
AR 0015755
SHEET TITLE:
DETAILS AND
PARTITION TYPES
NOTES /DATES: I
A CMU WALL B INTERIOR PARTITION WALL C INTERIOR PARTITION WALL D BATHROOM PARTITION WALL JOB NO.: SHEET NO.
W/ MOUNTING SUPPORTS 2005 -12 CARBONELL
PARTITION TYPES
SCALE: 1/2" = 1' -0"
PERMIT SUBMITTAL DATE:
9/29/05
DATE PRINTED:
oz /o� /os —
SCALE: ■
AS NOTED
DRAWN BY:
M.R.