05-1454-006tun Tnt irrrr+ VE SECTION THROUGH ARCHED ENTRANCE SCALE: 3/4" = 1' -0" F-AKI Rnv IC\ICInF* 5/8" PLYWOOD SHEATHING (SEE STRUCT. DWGS) 2" x 4" WD. TRUSSES (SEE STRUCT. DWGS) HURRICANE STRAP (SEE STRUCT. DWGS) USE ONLY TRIPPLE ZINC — G 185 GALVANIZED HANGERS & STR/9?&VANIZED DRIP EDGE T.O.B. ELEV. VARIES SEE ELEVS. 1"X2" WD. PT. 1"X6" FACIA BOARD 6 "x12" PVC TYPE SCREEN VENT METAL LATH AND STUCCO 3/4" STUCCO FINISH 8" CMU WALL (SEE STRUCT. DWGS) FINISH GRADE U-1 0 z 00 IaES IN ■ i i ■ ■ m . IN 0 12 4 DESIGNED IN ACCORDANCE_-WITri FBC 2001 & ASCE 7 =98_ - W 140 MPH WINDS EXPOSURE 'C' -_ R -30 BAT INSUL. WD. TRUSSES AT 24" O.C. +9' -6" CLNG. HEIGHT 1/2" DRYWALL ON 1"X2" P.T FURRING STRIPS, 16" O.C. 8" x 20" TIE BEAM @ ARCH WINDOW (SEE STRUCT. DWGS) NOTE: ALL WOOD MEMBERS ATTCHED TO CMU OR CONC. SHALL BE P.T. WOOD FOAM INSULATION, R -5 1/2" DRYWALL ON 1"X2" P.T FURRING STRIPS, 16" O.C. BASE, OWNER TO SELECT CONTROL JOINT FLOOR FINISH TO BE SELECTED AND PROVIDED BY OWNER G.C. TO INSTALL /— 4" CONC. SLAB +0' -8" T.O.S. N.G.V.D. 10' -8" 6 MIL VAPOR BARRIER �....— ...!.... -- .......... ........... —' .. —._ . - I.............'...i_— - 1.:f.:1 -11 ! I_Y_I- 95% COMPACTED FILL ---- , -. - -- — _ - - -- , I - - -. ..I WALL FOOTING, SEE 1I I I I STRUCT. DWGS FOR SIZES AND REBAR SPACING I; VAPOR BARRIER: VAPOR RETARDER CONSISTING OF 6 MIL MINIMUM POLYETHYLENE WITH JOINTS LAPPED 6" AND SEALED, INSTALLED UNDERNEATH THE SLAB. FBC. 1909.2 TYPICAL WALL SECTION SCALE: 3/4" = 1' -0" SEE MECH. ENERGY CALCS. FOR R -VALUE OF WALL EXTERIOR STUCCO, FLOAT FINISH INTERIOR EXTERIOR 8" CMU WITH #5 REINF. RODS SEE STRUCT. DWGS. iN 1 LAYER OF 1/2" GYPSUM BOARD .S. AND RIGID INSULATION ON MTL FURRING STRIPS, PAINT TYPICAL VENT DETAIL - THROUGH OVERHANG SCALE: 3/4" = 1' -0" SCHEDULED BASE FINISH FLOOR, SEE SCHD. DO NOT FASTEN TOP RUNNERS DIRECTLY TO TRUSSES! 8' -4' TRUSSES ABOVE B.O. C. 1/2 "" GYP. BD. CLG. 1" FURRING STRIPS 2 "x4" TOP RUNNER & FIREBLOCK ------------------ - - - - -- 3 -5/8" WD. STUD 16" D.C. 1/2" GYP. BD. 2 "x4" WD. @ MIDPOINT FOR FIREBLOCK /DRAFTSTOP INTERIC :RIOR BOTTOM RUNNER USE P.T WOOD ON CONCRETE BASE, BY OWNER FLOOR FINISH, BY OWNER, ON CONC. SLAB TERMITE PROTECTION: APPLIED AT FOUNDATION PERIMETER AFTER EXCAVATION AND BACK FILLING AND COMPACTING IS COMPLETE IN ACCORDANCE TO SECTION 1816.1.3 AND ALL OTHER SUBSECTIONS RELATED TO TERMITE PROTECTION. COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY. DO NOT FASTEN TOP RUNNERS DIRECTLY TO TRUSSES! 8'-4" TRUSSES ABOVE B.O.C. 1/2"" GYP. BD. CLG. \- 1" FURRING STRIPS 2 "x4" TOP RUNNER & FIREBLOCK ............ ...........3 -5/8" WD. STUD 16' O.C. 2 "x6" WD. BLOCKING BETWEEN STUDS FOR CABINETS 1/2" GYP. BD. 2 "x4" WD. ® MIDPOINT FOR - FIREBLOCK/DRAFTSTOP INT RIOR INTERIOR INTERIi ANCHOR 2 "x6" WD. BLOCKING BETWEEN STUDS ® ALL FIXTURE /CABINET LOCATIONS BOTTOM RUNNER USE P.T WOOD ON CONCRETE BASE, BY OWNER A AL X-1-OWNER, OFON CONC. SLAB TRUSSES ABOVE 1" FURRING STRIPS 1/2" MR GYP. BD. CLG. 2 "x4" TOP RUNNER & FIREBLOCK 1/2" GYP. BD. 3 -5/8" WD. STUD 16" O.C. "HROOM CERAMIC TILE, BY OWNER 1/2" DUROCK BOTTOM RUNNER USE P.T WOOD ON CONCRETE CERAMIC TILE FL. @ BATH COLTRAIN AND JONES ARCHITECTURE, P.A. DESIGN + CAD PRODUCTION CONSTRUCTION ADMINISTRA11ON BUILDING INSPECTIONS TEL(305) 285 -6723 FAX(305) 285 -6722 535 SW 8 ST. SUFE 100 MIAMI, FL 33130 REVISIONS /COMMENTS: w U Z w 0 w J J ui 0 Z m Q U i N ui 0 Q SEAL' w� r zCIO W Q Q � �O J LL _Q O = O , d hJ • , MARK A. COLTRAIN AR 0013380 RICHARD K. JONES, AIA AR 0015755 SHEET TITLE: DETAILS AND PARTITION TYPES NOTES /DATES: I A CMU WALL B INTERIOR PARTITION WALL C INTERIOR PARTITION WALL D BATHROOM PARTITION WALL JOB NO.: SHEET NO. W/ MOUNTING SUPPORTS 2005 -12 CARBONELL PARTITION TYPES SCALE: 1/2" = 1' -0" PERMIT SUBMITTAL DATE: 9/29/05 DATE PRINTED: oz /o� /os — SCALE: ■ AS NOTED DRAWN BY: M.R.