Loading...
05-1454-00512 4 F- 00 N WEST ELEVATION - (REAR) SCALE: 1/411 = 1' -0" WINDOW NOTES: I I+ i 4 12 12 41 714 ALL WINDOWS ON THIS ELEVATION ARE: PGT INDUSTRIES HORIZONTAL ROLLER, N.OAj 02- 0313.10, IMPACT RESISTANT 1. CONTRACTOR SHALL COORDINATE AND VERIFY WITH WINDOW MANUFACTURER'S SHOP DRAWINGS FOR REQUIRED MASONRY OPENING FOR PROPER INSTALLATION BEFORE CONCRETE BLOCK WORK IS STARTED OR TIE COLUMNS ARE POURED. G.C. TO VERIFY WITH WINDOW INSTALLER. WINDOW SIZES ON ELEVATIONS AND SCHEDULES ARE NOMINAL DIMENSIONS. WINDOW MANUFACTURERS DIMENSIONS MAY VARY. 2. INSTALLATION OF WINDOWS SHALL BE IN STRICT ACCORDANCE WITH THE DESIGNATED AND APPROVED METHOD INDICATED IN THE SHOP DRAWINGS AND THE N.O.A. SUBMITTALS AS APPROVED PER THE F.B.C. J. ALL FIXED GLASS PANELS SHALL BE 3116" OR THICKER AS REQ. TO MEET WIND LOAD AND IMPACT REQUIREMENTS. ALL GLASS USED INSIDE OF DWELLING TO BE TEMPERED, TO COMPLY WITH THE F.B.C. 4. ALL WINDOWS IN RENOVATION TO BE IMPACT RESISTANT. SEE MIAMI -DADE COUNTY PRODUCT APPROVALS (N.O.A.'S) AND SHOP DRAWINGS FOR EXACT SPECIFICATIONS. 5. EGRESS TYPE WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT, AND SHALL PROVIDE A CLEAR OPENING OF NOT LESS THAN 20" WIDE, 24" HIGH, AND 5.7 FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, AND NO PART OF THE MECHANISM SHALL BE PLACED HIGHER THAN 54" ABOVE THE FLOOR. 6. PRODUCT APPROVAL SHEETS (NOA'S) FOR ACCEPTABLE BUCK AND SCREW INSTALLATION, SCREW SPACING, SCREW LENGTH AND IMBEDMENT, ETC. 7. PROVIDE OPAQUE GLASS AT BATHROOM WINDOW AS PER F.B.C. 0 - _ _ ..................... _ _.......... _ — - - -- ELEV. + 19' -11 ROOF H.P. 12 —14 ELEV. +17' -0" CHIMNEY H.P. ELEV. +14' -8" ROOF H.P. ELEV. +12-10" ROOF H.P. 12 ELEV. +10' -6" 4r- T.O. TIE BEAM I------------- ------ � DEPTH OF T.B. EXTERIOR IMPACT RESISTANT GLASS -NOA ACCEPTANCE 101- 1109.03 o q cot 00 N 1 N 1 a CHIMNEY SHALL EXTEND AT LEAST 3FT. ABOVE THE HIGHEST POINT WHERE IT PASSES THROUGH THE ROOF AND AT LEAST 2FT. HIGHER THAN PORTION OF ROOF WITHIN 1OFT. HORIZONTALLY OF CHIMNEY AS PER F.B.C. 2804.2.4 ELEV. +15' -11" ROOF H.P. ELEV. +13' -10" — - ROOF H.P. 12 4 F_ ELEV. +14' -8" — ROOF H.P. 12 4F___i PGT INDUSTRIES HORIZONTAL ROLLER, N.O.A.# 02- 0313.10, IMPACT RESISTANT 00 L__J 6 "X12" GARAGE SCREEN VENT MOUNTED 12" A.F.F., TYP. NORTH ELEVATION SCALE: 1/4" = V -0" O °° N 12 4 12 4 Al 1 A -4.0 12 4 F- Ja 12 74 —14 _ ELEV. +13' -3" T.O. TIE BEAM 0 u u \ O 0 PGT INDUSTRIES CASEMENT, EXTERIOR FLUSH SOLID N.O.A.# 02- 0327.04, AND CORE FINISH GRADE WITH PGT FIXED WINDOW, N.O.A. IMPACT RESISTANT GLASS # 02- 0716.03, 3' -4" 5' -4" 3' -4" N.O.A. ACCEPTANCE #02- 0927.13 BOTH IMPACT RESISTANT EAST ELEVATION - (FRONT). SCALE: 1/4" = 1' -0" 12 4 1— PGT INDUSTRIES HORIZONTAL ROLLE° N.0 A.# 02- 0313.10, IMPACT RESIST I I 0o i O �i I i I \ A/C UNIT ON\ 4" CONC. PAD - (RIGHT SIDE) 12 41 00 00 O r•7 N O O ............. _._-_.... ----- _- ....................... � ALL WINDOWS ON THIS ELEVATION ARE: PGT INDUSTRIES HORIZONTAL ROLLER, € N.O.A.f 02- 0313.10, IMPACT RESISTANT 12 —14 12 � 4 ..... ........ ......................... ...... +19' -11" ROOF 1­11. P. _ ELEV. +15' -11" ROOF H.P. ELEV. +13' -10" 12 12 ROOF H.P. 4 F— —14 2'- 1 1. -2 9'-4 1 -2 2 -1 I ELEV. +0' -0" GRADE - N.G.V.D. 10 I tom. i, PGT INDUSTRIES CASEMENT, N OA.# 02- 0327.04, IMPACT RESISTANT '• I V 00 O d- 4 EGRESS WINDOW W/ ESCAPE OPENING: (MIN. 5.7 S.F., MIN W. 20 ", SOUTH ELEVATION - (LEFT SIDE) MIN. H. SILL ®44" A.F.F. MAX. SCALE: 1/4" = V -0" EGRESS WINDOW W/ ESCAPE OPENING: (MIN. 5.7 S.F., MIN W. 20 ", MIN. H. 24 ") SILL ® 44" A.F.F. MAX. ELEV. +19' -11" ROOF H.P. ELEV. +14' -8" 12 ROOF H.P. 14 1n I N ELEV. +0' -0" GRADE - N.G.V.D. 10.0' ELEV. +19' -11" ROOF H.P. ELEV. +15' -11" 1 H.P. -� 4 0 Q I t W cy) t- ELEV. +0' -0" GRADE - N.G.V.D. 10.0' ELEV. +19' -11" ROOF H.P. ELEV. +15' -11" 12 ROOF H.P. -� 4 W 00 I r7 T 12 12 , 14 - 14 EGRESS WINDOW W/ ESCAPE OPENING: (MIN. 5.7 S.F., MIN W. 20 ", MIN. H. 24 ") SILL 0 44" A.F.F. MAX. ELEV. +0' -0" GRADE - N.G.V.D. 10.0' COLTRAIN AND JONES ARCHITECTURE, P.A. DESIGN -I- CAD PRODUCTION CONSTRUCTION ADMINISTRATION BUILDING INSPECTIONS TEL1305) 285 -6723 FAX005) 285 -6722 535 SW 8 ST. SUITE 100 MIAMI, FL 33130 REVISIONS /COMMENTS: W U z W Q Cn W cy) t- W cv)M z` , W Q J Q Q cr W O z .�• J 0 co .. m 3�: a: Q Q cf) U O _ N � � W r0n c 0 SEAL- lo MARK A. COLTRAIN RICHARD K. JONES, AIA AR 0013380 AR 0015755 SHEET TIRE: ELEVATIONS NOTES /DATES: JOB NO.: SHEET NO. 2005 -12 CARBONELL PERMIT SUBMITTAL DATE: 9/29/05 DATE PRINTED: 02/07/06 A-3.0 scALE: AS NOTED DRAWN BY- M.R.