Loading...
05-1454-004N OTES : 1. SMOKE DETECTORS ARE TO BE HARDWIRED FOR 120V AND INTERCONNECTED WITH A BATTERY BACKUP. OS SMOKE DETECTOR -0-a SURFACE MOUNT LIGHT e GIMBLED WALL WASHER • POG LIGHT LT. RECESSED MOUNT LT. _0- EXHAUST FAN EX. FAN THREE -WAY RCD. LT. O RECESSED LIGHT O-II WALL MOUNT LIGHT OEXHAUST FAN /LIGHT O PENDANT LIGHT D FLOODLIGHT 4 DISCONNECT � DATA / PHONE � WALL MOUNT OULET WALL MOUNT SWITCH O JUNCTION BOX m ELECTRIC PANEL Tip CABLE TV OUTLET ® FLOOR MOUNT RECEPTACLE C COUNTER HEIGHT N NEW WP. WATER PROOF E EXISTING R RELOCATED DIM. DIMMER 3 THREE -WAY GF1 GROUND FAULT INTERRUPTED U.C. UNDER COUNTER V.P. VAPOR PROOF D DEDICATED CIRCUIT ATTIC VENT CALCULATION: HOUSE CLG. AREA: VENT AREA REQ'D.: VENT SIZE: REQ'D VENTS: 422,102 S.I./150 = 2880 S.I. 6 "x12" = 72 S.I. 2880 S.I. / 72 S.I. = 40 VENTS REFLECTED CEILING PLAN SCALE: 1 /4" = 1' -0" 4" EXHAUST VENT WITH SCREEN SEE DETL. 2, A -4.0 COLTRAIN AND JONES ARCHITECTURE, PA. DESIGN + CAD PRODUCTION CONSTRUCTION ADMINISTRATION BUILDING INSPECTIONS TEL.(305) 285 -6723 FAX.(305) 285 -6722 535 SW 8 ST. SUITE 100 MIAMI, FL 33130 REVISIONS /COMMENTS: W (1) z w O U) � � z co cy) � >o J Q � z � O LL m Qcf) � U0 Woo (o 0 ac Q SEAL MARK A. COLTRAIN AR 0013380 RICHARD K. JONES, AIA AR 0015755 SHEET TITLE: REFLECTED CEILING PLAN NOTES /DATES: JOB NO.: SHEET NO. 2005 -12 CARBONELL PERMIT SUBMrrrAL DATE: 9/29/05 DATE PRINTED: 02/07/06 SCALE: A-2.1 AS NOTED DRAWN BY: M.R.