Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-795-007
r_________________________________________________________ I I 1 , 4B I I I I I I I I I I , I 124 GFI /WR ° c - A 2013 A o ROOD �ioaT � I 014 ----- - - - - -J I S�. I I I I I 2© - - - - - -- - - - - -- 1 I I I I I I 19a GFI/U1 ' I I "-• I I I I I N.LC. I I 1 I � I I 1 ' I I 2�A 19A i i ' I Tv MASTER BEDROOM 1 � ' oos 205 iL------- -------- ---- ---- - - - - -� GFI/WP 19A I ' 19A - -- 193 PANTRY ' 205 GFI/WP ' - - - -- L-----------, � FOYER I I 1 I ' , 195 195 I U OUN A 193 ISA ISB ' 1913 I I I ' i IIA - -- UTILITY IIB I 1 - - -I 1 1313 � I 1 I I I I 1 I I I 1 I I I I I I I EXNnNG GARAGE ' I I I 1 I 1 1 I I I 1 I 1 I I I I I Q I :I 0 E.P. 1 EM Cl :1 ;1 ;1 MAIN ENTRY I I --- ----- - - - - -- I I I I 1 I I 1 I I , - - --I I ------------------------------------------------------ ELECTRICAL POWER PLAN A2.3 SCALE: 1/4' : 11 -0" ELECTRICAL NOTES: I. DO NOT SCALE DRAWINGS. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT AND CONFIRM WITH OWNER REPRE5ENTATIVE. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE N.E.G. AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 3. UNLESS OTHERWISE NOTED, MINIMUM WIRE SIZE SHALL BE No. 12 AWG. AND ALL CONDUCTORS SHALL BE COPPER WITH TW INSULATION FOR SIZES No. 6 AND SMALLER. CONDUCTORS LARGER THAN No. 6 SHALL HAVE TYPE THW INSULATION. ALL CONDUCTORS No. 10 AND SMALLER MAY BE SOLID. ALL THOSE No. 8 AND LARGER SHALL BE STRANDED. EQUIVALENT ALUMINUM CONDUCTORS CAN BE USED IN 5UBFEEDER5 No. 6 OR LARGER IF APPROVED BY LOCAL REGULATIONS. CONTRACTOR TO VERIFY. 4. ALL RACEWAYS AND PIPES PLACED IN OR THRU ANY CONCRETE SLAB SHALL BE SPACED A MINIMUM OF 3 DIAMETERS OF THE LARGEST CONDUIT OR PIPE OF ANY OTHER SERVICE. 5. ALL RACEWAYS UNDERGROUND AND /OR LARGER THAN 2 INCHES IN DIAMETER SHALL BE GALVANIZED RIGID STEEL. PVC PIPE SCH.40 WILL BE ACCEPTABLE, IF APPROVED BY LOCAL REGULATIONS. CONTRACTOR TO VERIFY. 6. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS AND CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS. -1. DISCONNECT SWITCHES SHALL BE QUICK MAKE, QUICK BREAK, IN NEMA 1 OR 3R ENCLOSURE, AS REQUIRED BY EXPOSURE. 8. ALL MATERIAL SHALL BE NEW AND SHALL BEAR UNDERWRITERS AND UNION LABELS WHERE APPLICABLE. 9. ALL WORK SHALL BE PERFORMED 5Y,4 LICENSED ELECTRICAL CONTRACTOR IN A WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENGJARCH MUST BE A CONDITION OF THE CONTRACT. ELECTRICIAN SHALL INDICATED ON ELECTRICAL PANEL BOARD AREAS SERVED BY EACH G.B. 10. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH PROGRESS OF CONSTRUCTION. II. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE OF DEFECT FORA PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. ELECTRICAL FLOOD CRITERIA: I. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED WITH SEPARATE INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS. 2. NO APPLIANCE OR APPLIANCE OUTLETS 5HALL BE INSTALLED BELOW BASE FLOOD ELEVATION. 3. A/C COMPRESSORS $HALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. 4. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION. S. COORDINATE WITH FLORIDA POWER AND LIGHT COMPANY TO LOCATE THE ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. I I I , I , I , 1 , I ' E•' • / , I � I ` ♦15a `\ _ I \ I /A - - - - - - - 1vP - �I -DIM ,'� I 84'AFF. `♦ 84'AFF. I ♦ / 1 -DIM l 1 I - ® ♦ ��r I I I ♦ ------------ __ - - - -- `♦1 - -- � � I W.I.C. - -- I 0 11 I ® o , I J MASTER I : , ---- - -' = =- -------------------------------------------------------------- - - - - -, BEDROOM I 00$ 1 I 19A 1 �'j �A /' SD — 19A �pIM �20A 1 , 1 I9B a I Wj 155 PANTRY ;AFF1 =t 1913 I 1 1 , �• 1913 � , L----------- � I I , I 1 I I I 1 1 I I I I I I I I __ UTILITY gB' 20A • I I — — — — — — — — — — — — -- - -- i i 002 I I —= I SDQ 003 �— -- — — — I I I 1 I I I I I 43 ' I I 1 Sd'AFF. ----- -- -- -- I EX=NO GARAGE I I 1 I i i i i i I I 145 I I I I S{4'AFF. I I I 1 I , I I — I I ;1 EM GFI/WP i i " ;I I 2 L IGNTING PLAN LEGEND ELECTRICAL WIRING CEILING MOUNTED FAN W /LIGHT. FAN BLADES TO BE MINIMUM 6' -8' APP. SC,4LE± 114" : 1' -0' TYPE: SERVICE: VOLTAGE: 240/120 V 10 3W MOUNTING: AMPS. POLE5 TOTAL CON - VA. DUIT 20 1 600 1/2 1•DIM SINGLE POLE W /ADJUSTABLE DIMMER ELECTRICAL LIGHT SWITCH CEILING MOUNTED A/C EXHAUST GRILL. FOR ® EXHAUST SIZE REFER TO MECHANICAL PLAN. 20 INFILTRATION ENERGY COMPLIANCE MINIMUM RE OUIREMENT5: BARRIER WINDOWS MINIMUM OF 034 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK(INCLUDES SLIDING GLASS DOORS). INTERIOR 1/2 15 JOINTS /CRACKS EXTERIOR t MAXIMUM OF 0.5 CFM PER 50. FT. OF DOOR AREA: SOLID CORE, WOOD PANEL, INSULATED OR GLA55 20 ADJACENT DOORS DOORS ONLY. EXHAU5T FANS EXTERIOR JOINTS TO BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED. HOT WATER PIPES 4 CRACKS 2 8900 SOLE 4 TOP SOLE PLATES AND PENETRATIONS THROUGH TOP PLATES OF EXTERIOR WALLS AND RAISED WOOD SHOWER HEADS PLATES FLOORS. COMP. AND MODEL TO BE CHOSEN BY OWNER 20 HVAC DUCT INFILTRATION INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS AND RAISED WOOD FLOORS CONSTRUCTION, BARRIER 1 INSULATION 4 TO BE CHOSEN BY OWNER 4 INSTALLATION LEGEND ELECTRICAL WIRING CEILING MOUNTED FAN W /LIGHT. FAN BLADES TO BE MINIMUM 6' -8' APP. SC,4LE± 114" : 1' -0' TYPE: SERVICE: VOLTAGE: 240/120 V 10 3W MOUNTING: AMPS. POLE5 TOTAL CON - VA. DUIT 20 1 600 1/2 1•DIM SINGLE POLE W /ADJUSTABLE DIMMER ELECTRICAL LIGHT SWITCH CEILING MOUNTED A/C EXHAUST GRILL. FOR ® EXHAUST SIZE REFER TO MECHANICAL PLAN. 20 1 600 I/2 15 1 600 1/2 15 1 600 1/2 20 1 600 112 CEILING MOUNTED EXHAUST FAN. 20 1 600 1/2 REFER TO MECHANICAL PLAN 50 2 10000 3/4 INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS AND RAISED WOOD FLOORS ALL OPENINGS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS MUST BE SEALED. EXHAUST FANS VENTED TO UNCONDITIONED SPACE SHALL HAVE DAMPERS, EXCEPT FOR COMBUSTION DEVICES WITH INTEGRAL EXHAUST DUCTWORK INSULATION 15 REQUIRED ONLY FOR RECIRCULATING SYSTEMS, INCLUDING HEAT RECOVERY UNITS. IN SUCH CASES, PIPING HEAT L055 SHALL BE LIMITED TO A MAXIMUM OF 1-1.5 BTUP PER LINEAR FOOR OF PIPE. WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 80 PSIG. ALL DUCTS, FITTINGS, MECHANICAL EQUIPMENT AND PLENUM CHAI`15ER5 514ALL BE MECHANICALLY ATTACHED, SEALED, INSULATED AND INSTALLED IN ACCORDANCE WITH THE CRITERIA OF SECTION 904fo, DUCTS IN UNCONDITIONED SPACE AND AIR HANDLERS LOCATED IN ATTICS MUST BE INSULATED TO A MINIMUM R -6 WIRE 12 12 14 14 12 12 ..;I 50 CEILING MOUNTED LIGHT FIXTURE O `� CEILING MOUNTED SMOKE DETECTOR 8 TO BE CHOSEN BY OWNER. LIGHTING 3A LIGHTING 35 50 CABLE Tv - OUTLET 10000 CEILING MOUNTED CHANDELIER T14 14 SB TO BE CHOSEN BY OWNER. A/C -EXIST 9A 50 2 8900 ELECTRICAL DUPLEX OUTLET 0 4' RECESSED LIGHT FIXTURE. COLOR A/C -NEW 13A COMP. AND MODEL TO BE CHOSEN BY OWNER 20 GFI ELECTRICAL WATERPROOF DUPLEX OUTLET 1/2 WALL MOUNTED LIGHT FIXTURE 20 1 1000 TO BE CHOSEN BY OWNER 4 WALL MOUNTED TELEPHONE JACK 2 SINGLE POLE ELECTRICAL LIGHT SWITCH 56© FF. 12 r` ch N JUNCTION BOX - WALL MOUNTED 56' AFF. $2 m EXISTING ELECTRICAL PANEL FEEDER: (3)"3/0 CU THW FED FROM: METER TWO -WAY ELECTRICAL LIGHT SWITCH a� -�-� $3 THREE -WAY ELECTRICAL LIGHT SWITCH NEW 80 GALLON WATER NEATER ® 4' RECESSED VAPOR RESISTANT LIGHT FIXTURE. NEW LOCATION OF EXISTING Vp COLOR AND MODEL TO BE CH05EN BY OWNER. CEILING MOUNTED FLOOD LIGHT FIXTURE. SCs -� STEAM GENERATOR LOCATED UNDER THE SHOWER SEAT. Lu ' CONTRACTOR TO PROVIDE ACCESS PANEL FROM CLOSET DISCONNECT SWITCHBOX Li WALL. MODEL TO BE CHOSEN BY OWNER rO INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS AND RAISED WOOD FLOORS ALL OPENINGS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS MUST BE SEALED. EXHAUST FANS VENTED TO UNCONDITIONED SPACE SHALL HAVE DAMPERS, EXCEPT FOR COMBUSTION DEVICES WITH INTEGRAL EXHAUST DUCTWORK INSULATION 15 REQUIRED ONLY FOR RECIRCULATING SYSTEMS, INCLUDING HEAT RECOVERY UNITS. IN SUCH CASES, PIPING HEAT L055 SHALL BE LIMITED TO A MAXIMUM OF 1-1.5 BTUP PER LINEAR FOOR OF PIPE. WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 80 PSIG. ALL DUCTS, FITTINGS, MECHANICAL EQUIPMENT AND PLENUM CHAI`15ER5 514ALL BE MECHANICALLY ATTACHED, SEALED, INSULATED AND INSTALLED IN ACCORDANCE WITH THE CRITERIA OF SECTION 904fo, DUCTS IN UNCONDITIONED SPACE AND AIR HANDLERS LOCATED IN ATTICS MUST BE INSULATED TO A MINIMUM R -6 WIRE 12 12 14 14 12 12 ..;I 50 2 5900 1/2 8 IB LIGHTING 3A LIGHTING 35 50 2 10000 3/4 6 14 SB -15 A/C -EXIST 9A 50 2 8900 112 8 IIB A/C -NEW 13A COMP. 135 20 1 1500 1/2 12 20 1 1000 1/2 12 20 2 2400 1/2 12 15 I 600 1/2 14 15 1 600 112 14 DEMAND LOAD: 44,449 WATTS 1852 AMPS ELECTRICAL R15ER DIAG-r -2AM (N.T.5.) REMARK5 CKT NO. LIGHTING IA LIGHTING IB LIGHTING 3A LIGHTING 35 LIGHTING 5A LIGHTING 55 AHU -EXIST 14 SB -15 A/C -EXIST 9A COMP. 93 AHU -NEW IIA 125 IIB A/C -NEW 13A COMP. 135 MASTER BATH 15.4 DISPOSAL 155 POOL 11A PUMP ISB LIGHTS 4 REC. 19A LIGHTS 4 REC. 195 ELECTRICAL METER 1 •2 TW. CU. IN C TO CWP. — 2' C. RIGID GALV, STL. EXIST. UNDERGROUND ELECTRICAL SERVICE / / I7 7I EXISTINC3 F ANEL 2 0 DISC. SW. CKT NO. REMARKS 2A REFRIGERATOR 25 KITCHEN GFI 4A RECEPTACLES 413 TERR. LIGHTS 6A BEDROOM "2 65 BEDROOM "I 8A WASHER SB DRYER 10A 1 1013 WHIRLPOOL 12A 1 125 RANGE t 14A OVEN 145 GAR DR OPNR. I&A WATER PUMP 168 SPRINKLER PUMP 18A WATER HEATER 185 N 20A BATHROOM 205 GFI REC. 3 - 03/0 CU. THW IN 2' C. 200 AMP. PANEL W/MAIN CIRC. BRKR. W/ 40 - IF SPACES. WIRE 12 12 14 14 12 12 12 10 E 6 (2) 10' -0' DEEP GROUNDING RODS Sje DIAMETER SPACED 6 FT. APART 4 BOND TO FOUNDATION. -- - FERMI -r &;_�T -- REy510NS DATE MAIN BUS: 200 AMPS NEUTRAL: MAINS: LOCATION: CON- DUIT TOTAL v.A. POLES AMPS 1/2 1500 1 20 V2 1500 1 15 112 600 1 20 1/2 600 1 20 1/2 1500 1 15 1/2 1500 1 15 1/2 1500 1 20 112 5000 2 30 1/2 I/2 I/2 1/2 1/2 1/2 I � Lu Lu ry p n ll—!l 1 z LL ARCHITECT OF RECORD A.R. 0010458 Cn 4500 0 30 4 w F— U U a Z ,i -'Lc) LI I Lr) O_ CU N N Z Q O Q U CU ~ N L0 C) a Lu m 1500 ¢ a C4 � N I�—p cfj 1 20 r` ch N N ARCHITECT OF RECORD A.R. 0010458 TO THE BEST OF MY KNOWLEDGE THESE PLANS COMPLY WITH THE2 -3 MINIMUM STANDARDS OF THE FLORIDA BUILDING CODE 2001 EDITION Cn 4500 2 30 w O O 1500 I 20 ,Z �l I�—p 1500 1 20 U FEEDER: (3)"3/0 CU THW FED FROM: METER 2' C. a� -�-� U Q Lu I- n Lu n w w n w Q DROU�I E. ALvARADO CHECKED E 4JRP. No DATE 05 -26 -05 SCALE As noted JOB NO. TD503 -02 GENERAL NOTE: SHEET TO THE BEST OF MY KNOWLEDGE THESE PLANS COMPLY WITH THE2 -3 MINIMUM STANDARDS OF THE FLORIDA BUILDING CODE 2001 EDITION