05-1525-005d �a . Q 6 3D� ►RD�N -�1 ME ELECTRICAL PLAN 0lrf-%LC: 1 /'F — I -V T. 150 AMPS TYPE: LOAD: CENTER EXIST. PANEL: "A" t "B" I PHASE 3 WIRES SERVICE: LIGHTS / APPLIANCES 10.000 AIC 120/240 V VOLTAGE: 240/120 V, 10 3W SOLID NEUTRAL AMPS. POLES V.A COND WIRF REMARKS CKT No CKT No REMARKS WI RE COND. V.A POLES AMPS. 50 2 7500 3 G AHU #1 1 2 DRYER FIRST 10 KW @ 10 % 2 0000 2 40 50 2 5000 3/4 G ACC # 1 3 4 5 G H.W.H G 3/2 5000 2 50 SPACE 7 8 20 1 000 1/2 12 WASHER 9 1 10 SMALL AP. 12 112 1500 1 20 50 2 800 1 G RANGE I 1 12 1 SMALL AP. 12 112 1500 1 20 13 14 DINING RECEPT. 12 1/2 1500 1 20 15 1 G GEN. LIGHTS FAMILY 12 1/2 GOO 1 20 20 I 1200 1/2 12 DISHWASHER 17 18 GEN. LIGHTS LIVING 12 112 000 1 20 20 1 GOO 1/2 12 COMPACTOR 19 20 GEN. LIGHTS ENTRANCE 14 112 500 1 15 20 1 750 1/2 12 REFRIGERATOR 21 22 GEN. LIGHTS CORRIDO 14 1/2 500 1 15 20 1 GOO 1/2 12 PLAYROOM 23 24 GEN. LIGHTS GROUND. 12 112 GOO 1 20 20 1 500 1/2 14 PLAYROOM 25 2G GEN. LIGHTS LIGHTS 12 1/2 GOO 1 20 20 I GOO 1/2 12 TOILETS 27 28 GEN. LIGHTS LIGHTS 12 1/2 GOO I 20 15 1 500 112 14 BEDROOM 29 30 GEN. LIGHTS TOILET 12 112 G00 1 20 15 1 500 1/2 14 BEDROOM 31 32 MASTER BR. 14 1/2 500 1 15 20 1 GOO 1/2 12 GEN. LTS. 33 34 MASTER BR. 14 1/2 500 1 15 15 1 500 1/2 12 GEN. LT5 35 3G SPACE 20 1 600 1/2 12 SMALL APP. 37 38 SPACE 20 1 000 1/2 12 BATHROOM 39 40 SPACE TOTAL CONN. LOAD: 39.750 W. ELECT. LOAD CALCULATION GENERAL LIGHTING 5WITCH 1450 S.F. @ 3W/5F 4350 SMALL APPLIANCES 4500 LAUNDRY 1500 RANGE 750 OVEN 6000 WATER HTR EXHAUST FAN WASHER D15WA5HER 1200 COMPACTOR GOO REFRIGERATOR 750 SUB -TOTAL 25.650 FIRST 10 KW @ 10 % 10.000 REMAINDER @ 40 % 8.120 A/C @ 100 % 7500 TOTAL 25.620/240 = I OG A NOTE: RECEPTACLES OUTLETS IN BEDROOMS SHALL BE PROTECTED BY AN ARC- FAULT CIRCUIT INTERRUPTERS METER CAN 10 I # 1/0 GRD CU -1 12" C TO CWP- 2-5/8"X I O'CU GRND RD. NEC - 250 -50 (C) NOTE: EXIST. FOOTERS IN HOUSE 2 1/2" # DOWN PIPE FOR POWER C.O. SECONDARY SERVICE CONDUCTORS VERIFY WITH POWER CO. _ BEFORE COMMENCING WORK 3 # 1/0 (CU) THWN -2'C 2P/150A DISC. NEMA 3R (10 K AIC) 150 A PNL 11811 40 CIRC. 3 # 1/0 # 8 (GRD) (CU) THWN IN 2" C ELECTRICAL RISER DIAGRAM NOTE: ALL WIRING 5HALL BE COPPER THWN RODRIGO H. CADAVID P.E. CIVIL AND STRUCTURAL ENGINEER PE # 0039415 13285 S.W. 124 ST, SUITE #14 MIAMI, FLA 33186 PH: (305) 385 -5220 = d„ ELECTRICAL NOTES: I . OUTSIDE RECEPTACLE5, RECEPTACLE5 AT BATH, GARAGE AND G FEET FROM KITCHEN SINK, SHALL BE G.F.I. 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM NON- 5WITCHABLE NO G.F.I. LIGHTING CIRCUIT INTERCONNECTED AND WITH BATTERY BACK -UP. 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY A5 PER SERVICE ENTRANCE LOCATION. 4. ELECTRICAL CONTRACTOR TO COORDINATE 5ERVICE WITH F.P.L. 5. ALL "J" BOXE5 SHALL COMPLY WITH N.E.C. 370 -17A. G. MAXIMUM NUMBER OF OUTLETS PER CIRCUIT SHALL COMPLY WITH S.F.B.C. 1990 DADE COUNTY EDITION (TABLE 45 -A). 7. ELECTRICAL OUTLETS (RECEPTACLE5 AND LIGHTING) BELOW BA5E FLOOD ELEVATION SHALL BE IN5TALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THE05E IN THE HABITAL AREA5. 8. NO APPLIANCE5 OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. 9. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BA5E FLOOD ELEVATION 10. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BA5E FLOOD ELEVATION. 1 1. IT 15 5UGGE5TED THAT YOU CONFER WITH FLORIDA POWER AND LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANGEMENT AGENCY REQUIREMENT5 ELECTRICAL LEGEND: $ 5WITCH DUPLEX RECEPTACLE T SPECIAL RECEPTACLE 0 CEILING MOUNTED FIXTURE Q WALL MOUNTED FIXTURE ® RECESSED CEILING FIXTURE 0 EXHAUST FAN ❑p DISCONNECT 5WITCH !� ELECTRIC PANEL 23 ELECTRIC METER WP WEATHER PROOF GFI GROUND FAULTED INTERRUPTER E -1 PROPOSED NEW ADDITION & REVISIONS FOR: Mr. & Mrs. GONZALES 7861 S.W. 68 th AVE.,MIAMI, FL. 33143 ELECTRICAL PLAN DRAWN BY: I.G