05-1525-003a a .4 a a a 4 a a _ d o� I I I I GARDEjN I I ' I 2" CD. LINE TO O1,JTSIDE STRUCT. t TO �\ TERMINATED FACE DN. " ABV. GRADE @ BLDG. ER. IOR. Q Q a SCALE: 1/4" = 1' -0" II „ I REFR. LINES 7/8" t- 3/8" REF. I EXISTING WIN1111 O m A/C. DUCT R G INSULATION (TYPICAL) TYP. AROUND UNIT CLOSET PARTITION WALL PROVIDE CAP OFF W/ 1/4" A.H.0 PERFORATION FOR VENT PROVIDE FLOAT SWITCH AT 5ECUNDAKY DRAIN CONNECTION TO CONTROL OVERFLOW BY SHUTTING DOWN THE SYSTEM AS PER FMC 5ECTION 307 �.— - - - -- - a A.H.U. DETAIL - MECHANICAL CODE - - UNDERGROUND CONDENSATE DRAIN LINE SHALL BE 2 INCHES DIAM. MINIMUM. - ANCHORING DETAIL OF THE CONDENSING UNIT TO THE CONCRETE SLAB TO WITHSTAND 120 M.P.H. WIND FORCE. - ALL EXHAUST DUCTS SHALL BE CONSTRUCTED OF SHEET METAL, TERMINATE OUTSIDE THE BUILDING, AND BE EQUIPPED WITH A BACKDRAFT DAMPER. (NO T -FIN ALLOWED) - ALL TOILETS ROOMS, NOT HAVING AN OUTSIDE OPERABLE WINDOWS, SHALL BE PROVIDED WITH A MECHANICAL EXHAUST SYSTEM TO PRODUCE I COMPLETE AIR CHANGE EVERY 3 MINUTES, EXCEPT THAT WHERE THE THE VENTILATING AIR HAS BEEN CONDITIONED, THERE SHALL BE A COMPLETE AIR CHANGE EVERY 7 1/2 MINUTES.- (AN A/C DROP IN THE TOILET ROOM FOR AN INTERIOR BATHROOM 15 NOT SUFFICIENT OR ACCEPTABLE MEANS OF VENTILATION.- AN EXHAUST FAN SHALL BE PROVIDED.) - DUCTS FROM 'TOILET ROOMS" SHALL DISCHARGE TO THE OUTSIDE OF THE BUILDING, SHALL BE TERMINATED NOT LE55 THAN G INCHES ABOVE THE FINISHED ROOF SURFACE, AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING A MESH 51ZE NOT LARGER THAN 1/2 INCH. (PROVIDE G005E NECK OR RAIN CAP ON ROOF TERMINATIONS)' "FOR THE PURPOSE OF THI5 PARAGRAPH, THE TERM 'TOILET ROOM" SHALL BE CONSTRUED AL50 TO MEAN BATHROOMS, SERVICE SINK ROOMS, AND JANITOR'S CLOSETS. - CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED. 4" DIA. MIN. - CLOTHES DRYERS EXHAUST DUCTS (OR VENTS) SHALL COMPLY WITH MANUFACTURER'5 INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A MINIMUM 2G GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCTS JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL 5CREW5 OR OTHER FASTENERS WHICH EXTEND INTO THE DUCT. \m BE BE N.T.S. CONDEN51NG UNIT 6" MIN. 112" ANCHOR BOLT BY 2" EA. —J CORNER W 12X2 BY 1 /8" L WELDED. A/C COMP SHALL BE INTALLED ABOVE BASE FLOOD ELEVATION G' MIN. neoprene pad (typical), CONCRETE BASE W/ GXG - 10/ 10 WWF- a a a • 4 L concrete pad NOTE: UNITS SHALL BE CLEAR BY 3" MIN. FROM DRAP LINE. a BUILT -IN A.H.U. DISC. TO COMPLY WITH NEC. 110 -1 G – PROVIDE 3/4" PVC. OVERFLOW _ (2" BELOW GROUND SLAB) NOT SHOWN FOR CLARITY A.H.U. 5UPPORT5 CONC. 5LAB METAL BAND 1 -1 /2" 20 GA. TYP AROUND COND. UNIT AS SHOWN LIQUID AND SUCTION LINE W/O INSULATION CONDENSING UNIT MO N.T.S. METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION_ PROVIDE INSULATION GUARD WHERE NECESSARY PROVIDE FIBERGLASS INSULATION SEAL TO NECK * PERIMETER OF DIFFUSER DIFFUSER OR REGISTER (RESIDENTIAL GRADE) SEAL JOINT WITH DUCT SEALER AND TAPE —, POWER t CONTROL CONNECTIONS SEAL ENTRANCE OF REFRIGERANT LINES INTO P.V.C. PIPE W/ IMPERMEABLE, RE51LENT MATERIAL 4" SCHEDULE 40 P.V.C. PIPE SUCTION LINE W/ I -1 /2" ARMAFLEX INSULATION t VAPOR BARRIER UNTING DETAIL R -G MIN. INSULATION O1� 2_J INSULATED FLEX. DUCT R G MIN. INSULATION SEAL JOINT WITH DUCT SEALER AND TAPE AIR FLOW DRIGO H. CADAVID RE- V- C IL AND STRUCTURAL ENGINEER PE # 0039415 1 285 S.W. 124 ST, SUIT #14 MIAMI, FLA PH: (305) 385 -5220 R -G MIN. INSULATION FLEXIBLE DUCT CONNECTION DETAIL: N.T.S. s� •'... YYt I -112"X2 2 GAUGE METAL STRAP ANCHORD TO SLAB W /SPAN510N ANCH. @ cF r hAAV MAX 5 FT. SPACING BETW. SUPPORT GAL. METAL STRAP SUPPORT W /METAL SCREW LOW VELOCITY FLEXIBLE DUCT FLEXIBLE DUCT SUPPORT DETAIL N.T.S. GRA55ED AREA — 2" CONDENSATE DRAIN PIPE —, DRAIN AREA 501L N.T.S TO CONDENSATE A/C UNIT DRAIN DRAIN LINE CONNECTION INSTALLATION OF PIPING TO CLEAR FILTER PULL OUT AREA t- SERVICE REMOVABLE PANELS D� I N�i�NGMNT CONDENSATE AT Alit CONDITIONER UNIT N.T.5 DUCT TRANSITION DRYER V N.T.S. EXHAUST ROOF CAP BIRD SCREEN NOT FOR DRYER ROOF TILE ON B.U.R. 4 2 "X4" 8 "X 12" GALV. DUCT FROM (2G GAUGE) ENT TERMINATION DETAIL PROPOSED NEW ADDITION & REVISIONS FOR: Mr. & Mrs. GONZALES 7861 S.W. 68 th AVE.,MIAMI, FL. 33143 MECHANICAL PLAN &DETAILS DRAWN BY: I.G