05-1525-003a
a
.4 a
a
a
4 a
a _ d
o�
I I
I I
GARDEjN
I I
' I
2" CD. LINE TO O1,JTSIDE
STRUCT. t TO �\
TERMINATED FACE DN.
" ABV. GRADE @ BLDG.
ER. IOR. Q
Q a
SCALE: 1/4" = 1' -0"
II „
I
REFR. LINES
7/8" t- 3/8" REF. I
EXISTING WIN1111
O
m
A/C. DUCT R G INSULATION (TYPICAL)
TYP. AROUND UNIT
CLOSET PARTITION WALL
PROVIDE CAP OFF W/ 1/4"
A.H.0 PERFORATION FOR VENT
PROVIDE FLOAT SWITCH AT
5ECUNDAKY DRAIN CONNECTION TO
CONTROL OVERFLOW BY SHUTTING
DOWN THE SYSTEM
AS PER FMC 5ECTION 307
�.— - - - -- - a
A.H.U. DETAIL
- MECHANICAL CODE -
- UNDERGROUND CONDENSATE DRAIN LINE SHALL BE 2 INCHES DIAM. MINIMUM.
- ANCHORING DETAIL OF THE CONDENSING UNIT TO THE CONCRETE SLAB TO
WITHSTAND 120 M.P.H. WIND FORCE.
- ALL EXHAUST DUCTS SHALL BE CONSTRUCTED OF SHEET METAL, TERMINATE
OUTSIDE THE BUILDING, AND BE EQUIPPED WITH A BACKDRAFT DAMPER.
(NO T -FIN ALLOWED)
- ALL TOILETS ROOMS, NOT HAVING AN OUTSIDE OPERABLE WINDOWS,
SHALL BE PROVIDED WITH A MECHANICAL EXHAUST SYSTEM TO PRODUCE
I COMPLETE AIR CHANGE EVERY 3 MINUTES, EXCEPT THAT WHERE THE
THE VENTILATING AIR HAS BEEN CONDITIONED, THERE SHALL BE A COMPLETE
AIR CHANGE EVERY 7 1/2 MINUTES.- (AN A/C DROP IN THE TOILET ROOM
FOR AN INTERIOR BATHROOM 15 NOT SUFFICIENT OR ACCEPTABLE MEANS OF
VENTILATION.- AN EXHAUST FAN SHALL BE PROVIDED.)
- DUCTS FROM 'TOILET ROOMS" SHALL DISCHARGE TO THE OUTSIDE OF THE
BUILDING, SHALL BE TERMINATED NOT LE55 THAN G INCHES ABOVE THE
FINISHED ROOF SURFACE, AND SHALL BE SCREENED WITH A CORROSION
RESISTANT MATERIAL HAVING A MESH 51ZE NOT LARGER THAN 1/2 INCH.
(PROVIDE G005E NECK OR RAIN CAP ON ROOF TERMINATIONS)'
"FOR THE PURPOSE OF THI5 PARAGRAPH, THE TERM 'TOILET ROOM" SHALL
BE CONSTRUED AL50 TO MEAN BATHROOMS, SERVICE SINK ROOMS, AND
JANITOR'S CLOSETS.
- CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED. 4" DIA. MIN.
- CLOTHES DRYERS EXHAUST DUCTS (OR VENTS) SHALL COMPLY WITH
MANUFACTURER'5 INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A
MINIMUM 2G GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE
WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW.
DUCTS JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL 5CREW5
OR OTHER FASTENERS WHICH EXTEND INTO THE DUCT.
\m
BE
BE
N.T.S.
CONDEN51NG
UNIT
6" MIN.
112" ANCHOR BOLT BY 2" EA. —J
CORNER W 12X2 BY 1 /8" L WELDED.
A/C COMP SHALL BE INTALLED
ABOVE BASE FLOOD ELEVATION
G' MIN.
neoprene pad (typical),
CONCRETE BASE W/
GXG - 10/ 10 WWF-
a a a
• 4 L
concrete pad
NOTE: UNITS SHALL BE CLEAR
BY 3" MIN. FROM DRAP
LINE.
a
BUILT -IN A.H.U. DISC. TO
COMPLY WITH NEC. 110 -1 G –
PROVIDE 3/4" PVC. OVERFLOW _
(2" BELOW GROUND SLAB) NOT
SHOWN FOR CLARITY
A.H.U. 5UPPORT5
CONC. 5LAB
METAL BAND 1 -1 /2" 20 GA.
TYP AROUND COND. UNIT AS
SHOWN
LIQUID AND SUCTION LINE
W/O INSULATION
CONDENSING UNIT MO
N.T.S.
METAL ROUND FITTING
QUADRANT OPERATOR
TO BE OUTSIDE INSULATION_
PROVIDE INSULATION GUARD
WHERE NECESSARY
PROVIDE FIBERGLASS
INSULATION SEAL TO
NECK * PERIMETER OF
DIFFUSER
DIFFUSER OR
REGISTER
(RESIDENTIAL GRADE)
SEAL JOINT WITH
DUCT SEALER
AND TAPE —,
POWER t CONTROL
CONNECTIONS
SEAL ENTRANCE OF REFRIGERANT
LINES INTO P.V.C. PIPE W/
IMPERMEABLE, RE51LENT MATERIAL
4" SCHEDULE
40 P.V.C. PIPE
SUCTION LINE W/ I -1 /2"
ARMAFLEX INSULATION
t VAPOR BARRIER
UNTING DETAIL
R -G MIN. INSULATION
O1�
2_J
INSULATED FLEX. DUCT
R G MIN. INSULATION
SEAL JOINT WITH
DUCT SEALER
AND TAPE
AIR FLOW
DRIGO H. CADAVID RE-
V- C IL AND STRUCTURAL ENGINEER
PE # 0039415
1 285 S.W. 124 ST, SUIT #14
MIAMI, FLA
PH: (305) 385 -5220
R -G MIN.
INSULATION
FLEXIBLE DUCT CONNECTION DETAIL:
N.T.S. s� •'...
YYt
I -112"X2 2 GAUGE METAL
STRAP ANCHORD TO SLAB
W /SPAN510N ANCH. @
cF r hAAV
MAX 5 FT. SPACING
BETW. SUPPORT
GAL. METAL STRAP
SUPPORT W /METAL SCREW
LOW VELOCITY
FLEXIBLE DUCT
FLEXIBLE DUCT SUPPORT DETAIL
N.T.S.
GRA55ED AREA —
2" CONDENSATE
DRAIN PIPE —,
DRAIN AREA
501L
N.T.S
TO CONDENSATE A/C UNIT DRAIN
DRAIN LINE CONNECTION
INSTALLATION OF PIPING TO CLEAR
FILTER PULL OUT AREA t- SERVICE
REMOVABLE PANELS
D� I N�i�NGMNT CONDENSATE
AT Alit CONDITIONER UNIT
N.T.5
DUCT TRANSITION
DRYER V
N.T.S.
EXHAUST ROOF CAP
BIRD SCREEN
NOT FOR DRYER
ROOF TILE ON B.U.R.
4
2 "X4"
8 "X 12" GALV. DUCT
FROM (2G GAUGE)
ENT TERMINATION DETAIL
PROPOSED NEW ADDITION & REVISIONS
FOR: Mr. & Mrs. GONZALES
7861 S.W. 68 th AVE.,MIAMI, FL. 33143
MECHANICAL PLAN &DETAILS
DRAWN BY: I.G