05-1525(3)-005:
•t•
i
METAL SHED
EXISTING
CONC. WALKWAY
74.58'
I I
I I
I I
I- I
- EXISTING I-- — —�
TO BE RELOCATED
EXISTING
SWIMMING POOL
Zill._�i /.L
0
PROPOSED
r-I
19' -4' NEW ADDTION
/� ....
�.
- .:
I . ) .......... ...............................
............ ...................................... ....................:... :......
:::: : ::.:.:::::::::::: EXISTING ONE STORY
RESIDENCE # 125 :.:::::::::::::::::::::::::.
....:.
4
— PROPOSED
NEW WOOD FENCE
op
]-
-
�I
P.
nr }
4 —d
PROPO ED
CAR -PO T n n
ENCLOS RE °
4 °
A
° EXI TING DRIVEWAY A
°
A n
°
4 74.55'
°
A n
n
°
n 4 v
n
44 n EXIST. PARKWAY
°
°
n n
A n
°
°
4
4
- S.W_._68_th._AVE•
SITE PLAN
SCALE: 3/32 - V-011
LEGAL DESCRIPTION
78G I S.W. GBth. AVE., MIAMI,FL.33 143
LOT 15 BLK. -
LUDLAND GROVES
ACCORDING TO THE PLAT THEREOF AS RECORDED IN
PLAT BOOK 58 AT PAGE 48 OF THE PUBLIC RECORDS
OF DADE COUNTY, FLORIDA.
SCOPE OF WORK.
• PROP05ED NEW ADDITION (FAMILY ROOM)
• REV1510N FOR: LAUNDRYT AHU CLOSET
'M.E.P WORK UNDER TH15 PERMIT.
b
rYi
d'
WALL LEGEND
-NEW 8" CBS. WALL
U EXISTING 8" CBS. WALL
■ #5 FILL CELL ATTACHED TO FTG. T CONC. BM.
G" MIN EPDXY EA. SIDE OF OPNG
® NEW 4" WD. PART. WALL
0 EXIST. 4" WD. PART. WALL
AREAS SCHEDULE
' NET LOT AREA : I 0,G75 5Q.FT.
EXIST. COVER AREA CONSTRUCTION: 2045 5Q.FT.
' AREA NEW ADDITION: 109 5Q.FT.
' TOTAL AREA HOUSE : 22 154 5Q.FT.
FLOOR PLAN - PROPOSED
SCALE: 1 \8 " =V -0"
GENERAL NOTES_: i
I.-WORKS PERFORMED SHALL COMELY WITH TtiE FOLLOWING
A) ALL NOTES WRITTEN ON ALL Shfti5 AMU % OR VLANS
OF THE PRESENT PROJECT. I
B) ALL APPLICABLE LOCAL, COUNTY OR STATE ORDINANCE.
2.- ON 51TE VERIFICATION OF ALL DIMEN51ON5 AND CONDITIONS
SHALL BE RESPONSIBILITY OF THE CONTRACTOR.1
3.- IT SHALL BE RESPONSIBILITY OF THE GENERAL! CONTRACTOR
TO VERIFY WITH THE ENGINEER IN WRITING ANY OMISSIONS OR
DISCREPANCIES ARISING FROM THE INFORMATION CONTAINED
WITHIN THESE SPECIFICATIONS AND DRAWINGS.
4.- CONTRACTOR AND SUBCONTRACTOR SHALL COMPLETELY
FAMILIARIZE THEMSELVES WITH EXISTING SITE CONDITIONS AND VERIFY
THE LOCATION AND AVAILABILITY OF ALL UTILIES PRIOR TO
SUBMITTING BID. i
5.- CONTRACTOR SHALL BE RESPONSIBLE FOR THE OESING AND
CONSTRUCTION OF THE FORMWORK. '
G.- IF ANY DISCREPANCIES ARE FOUND, 5TOP WORKING AND CONTACT
THE OWNER * THE ENGINEER.
NOTE DOORS
21 -2.4.1 NO DOORS IN THE PATH OF TRAVEL OF MEAN 5CAPE
SHALL BE LESS 28' 1 h.
DOOR SHALL BE MIN G' -G" (2m) NOMINAL HT.
21.2.4.3. EVERY CLOSET DOOR LATCH SHALL BE SUCH CHINDREN CAN OPEN
THE DOOR FROM INSIDE THE CLOSET. • I
21 .2.4.4. EVERY BATHRM DOOR SHALL BE DE51NG'T0 ALLOW OPENING FROM
THE OUTSIDE DURING AN EMERGENCY WHWN LOCKED
SECURITY AND FORCED ENTRY PREVENTION
'.- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RE5I5TIN5 A
FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN
ACCORDANCE WITH RESISTANCE 5TANDAR5 SET FORTH IN THE FLORIDA
BUILDING CODE,
'.- ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY
OPERATED FROM THE EXTERIOR WITH A MINIMUN OF 6000 P0551BLE
KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH
HARDENED BOLT INSERTS.
'.- THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE
SAME LOCK5 A5 REQUIRED FOR SINGLE EXTERIOR SWING DOORS THE
INACTIVE LEAF SHALL HAVE MULTIPLE POINTS OF LOCKS WITH 5/8"
MIN. THROW BOLTS WITH INSERTS.
•.- HINGES ON EXTERIOR OUT 5WINGIN5 DOORS SHALL HAVE NON
Rti.40VABLE PINS AND NON - EXPOSED SCREWS.
•.- G A55 AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN
NATIONAL 5TANDAR5 INTITUTE'S 5TANOAR5 297. 1'.
'.- VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF
THE IN51DE LOCKING ACTIVANTING DEVICE OF L005E AND SWING DOORS
SHALL COMPLY WITH THE AMERICAN NATIONAL 5TANDAR5 INTITUTES
5•fANDAR5 297.1 i
'. SLIDING GLA55 DOORS AND WIND. SHALL DE IN5T. AND CON5T. SO THAT
NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION
AND 50 AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MAGS.
ASSOCIATION 5TANDAR5 FOR FORCE ENTRY RESISTANCE, AAMA 13.33
PROVIDE LOCK5 A5 PER FBC '04. (A) (B) 2 (AA) AND (C) EXTERIOR
WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITH5TANDINGA
FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION.
'.- EX ERIOR WINDOW USED AS A MEANS OF ESCAPE SHALL ALSO COMFY
WITH A DOOR SCOPE OR V1510N PANELS.
'.- FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDE WITH A DOORS SCOPE
OR Vi510N PANELS.
a
r�
TERMITE PROTECTION
ALL BUILDINGS SHALL HAVE PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST
SUBTERRANEAN TERMITES. THE RULES AND LAWS AS E5TABLI5HED BY THE FLORIDA
DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE DEEMED AS APPROVED
WITH RESPECT TO PRE - CONSTRUCTION SOIL TREATMENT FOR PROTECTION AGAINST
SUBTERRANEAN TERMITES. A CERTIFICATE OF COMPLIANCE SHALL BE 155UED TO THE
BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY
NOTE
ALL WORK SHALL BE TO CONFORM
Wi F.B.C: 04.
!
1
!
I
i
G
Aml
PROPOSED NEW ADDITION & REVISIONS
FOR: Mr. & Mrs. GONZALES
7861 S.W. 68 th AVE.,MIAMI, FL. 33143
SITE PLAN & FLOOR PLAN
DRAWN BY: I.G
. .
a
J
M
z
O
U
C.0
o
z
I /
r-l�
to Ln
.�.
U)
Q.
0) N
N
z
N N
(�
U
� Ln
.—
a
o 0
MM
W
lO
0
G
_ x
u_
w
z .
z
a.
Cd
�G
�.
1 1--�
(
N
:J
U
o
rn
Z
Q0
u
Q
w-
I
L
<
d
n
I
W
u�
w
LL!
u M
h-
M
� v
It O
r-1
U) E
t-i (0
h
z
a
M
U) Li
z w
cm
la N
7�
U
cn
O M
c
�C3 h�
�_ N
C> M
c3 "'
•cam - ...
,� 4
�
I /
,� 4