Loading...
05-1525(2)-011- 1 a i Lo J J O l�- a� �0 0 9 G' -G" I I\• I II I I v I N __x411/ Fr. EXIST. ROOF 0 3 I — — — — fi - ...... ...... ...... _ ...._ ._._._._._._,.........._... .�._ 1 I I I 1 1 I I L I I 1 I 1 it I I I I I I I I I I ._._r. -_... - ._. _. _. ...... II I I 1 1 I I I I I I I 21 11 •�•� .� ._ .1_._ - -r- - -T o -1 ���i0 T1 I � U N i EXIST. ROOF IM I I .�- - Ln I I� I I 110 0 . --------- ._._._._...L o ° '/411/ FT. Q .._. -------- it I x I I I I ci �...H. - 1.7._._._._._._ _.- ._._._.I .r I I I I I I I I I I O _i -4 -------------------------- . .. ...- ....... .............. - '" N -I -I -- 1I �• ( I I I `� I I II I o _j TB 1 I --j ¢, 131 -G" - ROOF PLAN SCALE: 1 \4 "= 1'-•0" ROOF NOTES: ALL ROOFING ACCESSORIES AND MATERIALS SHALL HAVE DADE COUNTY PRODUCT CONTROL APPROVAL AND MUST BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS AND DIRECTIVES OF THE NOTICE OF ACCEPTANCE ISSUED FOR EACH INDIVIDUAL PRODUCT OF THE SYSTEM. ROOF SHEATHING SHALL BE A.P.A. RATED, NOT LESS THAN 5 /6" (19/32") EXTERIOR GLUE TYPE PLYWOOD SHEATHING AND SHALL HAVE MANUFACTURER'S PRODUCT STAMP CLEARLY VISIBLE. INSTALL SHEATHING IN ACCORDANCE WITH REQUIREMENTS OF F.B.C. CHAPTER 23. SHEATHING SHALL BE NAILED TO ROOF TRUSSES TO FORM A DIAPHRAGM USING NO. I Od GALV. RING SHANK NAILS (311x0. 135 MIN. SHANK DIA. AND RING OF 0.0 1 2 DIA. OR LARGER) @ G "O.C. (U.O.N.). BLOCKED * UNBLOCKED PLYWOOD DIAPHRAGM SHALL CONSIST OF 5/8" STRUCTURAL GRADE I PLYWOOD CONTINUOUS OVER TWO OR MORE SPANS, FACE GRAIN PERPENDICULAR TO SUPPORTS, FASTENED WITH I Od GALV, RING SHANK NAILS, I %" MIN. PENETRATION IN 2" MIN. NOMINAL FRAMING MEMBERS SPACED AT 4" O.C. AT ROOF DIAPHRAGM BOUNDARY PANELS t AT G" O.C. AT ALL OTHER PLYWOOD PANEL EDGES AND ALONG INTERMEDIATE FRAMING MEMBERS. FLOOR DESING CRITERIA DEAD LOAD: 2G PSF. LIVE LOAD :30 PSF O VENTILATION: SOFFIT VENTILATION REQUIRED 1,430 SQ. FT. = 9.5 SQ. FT. SOFFIT VENTILATION PROVIDED G" X 2411 144 10 VENTS @ I SQ. FT. EA. = 10 SQ. FT. TOTAL VENTILATION PROVIDED 10 SQ. FT. DOKOWALL TRUSS TYPE HORIZONTAL {�' "' REINFORCING EVERY OTHER COURSE (I G") CS. - BLOCK� EXTEND 4" INTO CONC. COLUMN. MORTAR Sf1ALL~COMPLY W/ ASTM C -270 SLUMP 5" MIN. - 8" MAX. #3 DOWEL_ WELDED TO COL @36" O.0 do 12" FROM JOINT HALVES AS PER TOP & BOTTOM. MRF RECOMMENDATIONS W/ CONC/ CEMENT GLUE. - 10" DIA. PREFAB STEEL COL DECORATIVE COLUMN (SEE PLAN FOR (SEE PLAN) SIZE & LOCATION) DECORATIVE COLUMN DETAIL SCALE: N.T.S. BACKER ROD & RESILIENT CAULKING EA. FACE 3/4" VERT. CONTROL JOINT •� FILLED CELL W/ TYP. WALT_ REINF. EA. SIDE OF CONTROL JOINT NOTES: 1. CONTROL JOINT SHALL BE CONTINUOUS WITHOUT INTERRUPTION FROM FOUNDATION TO TOP OF WALL. 2. TERMINATE HORIZ. REINF. 2" FROM CONTROL JOINT. 3. MAX. SPACING OF CONTROL JOINTS SHALL BE 3 x WALL HEIGHT OR 50' -0 ", WHICHEVER IS LESS. MASONRY CONTROL .JOINT DETAIL SCALE: N.T.S. STRUCTURAL NOTES: SOIL STATEMENT: FOR A VISUAL INSPECTION, THE SOIL IS ROCK AND SOND WITH A BEARING CAPACITY OF 2000 PSF, HOWEVER IF AT THE TIME OF CONSTRUCTION DIFFERENT CHARACTARISTICS ARE ENCOUNTERED, ENGINEER WILL HAVE TO BE CONTACTED. ALSO AT THE TIME OF CONSTRUCTION, A LICENSED ENGINEER OR ARCHITECT SHALL SUBMIT A LETTER ATTESTING THAT THE SOIL HAVE BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN 15 BASED. SOIL COMPACTION: FILL AND BACKFILL TO BE COMPACTED TO A MIN. OF 95% OF THE MAXIMUM DENSITY AT OPTIMUS MOISTURE AS DETERMINED BY TESTS. COMPACTION TEST REPORTS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL BEFORE STARTING CONSTRUCTION WORK. TERMITE TREATMENT: TERMITE TREATMENT CERTIFICATE SHALL BE SUBMITTED TO THE BUILDING OFFICIAL AFTER COMPATION IS COMPLETED. SLAB ON FILL: SHALL BE PLACED ON CLEAN NON ORGANIC SOIL MOISTENED BEFORE CONCRETE IS POURING. SHALL BE POURED IN A CHECKERBOARD 5EQUE- NCE EACH FRAGMENT OF WHICH NOT EXCEED A MAXIMUM AREA OF G25 S.F. OR 30 LINEAL FEET IN ANY DIRECTION. ALSO PROVIDE A POLYETHY- LENE FILM (0.000) UNDER THE SLAB ON GROUND OVER A WELL COMPACTED FILL. FIRE STOPPING: SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT SPACES BOTH VERTICAL AND HORIZONTAL. STEEL STRENGTH: SHALL BE 60,000 PSI. CONCRETE STRENGTH: FOOTINGS... 2,500 PSI, COLUMNS, BEAMS AND SLAB ON GROUND SHALL BE NO LESS THAN 3,000 PSI. PLYWOOD SHEATHING: PLYWOOD ROOF SHEATHING SHALL BE 32" WITH A FACE GRAIN PERPENDICULAR TO THE SUPPORTS, ON A CHECKERBOARD DISTRIBU- TION. PLYWOOD PANELS SHALL BE NAILED TO SUPPORTS WITH 8 -D COMMON NAILS, SPAC- ING AT PANELS EDGES G" AND AT GABLE END 4 ". EAVE AND GABLE DRIP SHALL BE INSTALLED SO THAT THE BOTTOM OF THE DRIP EDGE SHALL HAVE A MINIMUN OF 2" CLEARANCE FROM THE STRUCTURE.. CONSTRUCTION NOTES: TIE COLUMNS: CONCRETE TIE COLUMNS SHALL BE REQUIRED IN EXTE- RIOK WALLS OF UNIT MASONRY. CONCRETE TIE COLU- MNS SHALL BE REQUIRED AT ALL CORNERS, AT INTER- VALS NOT TO EXCEED I G'- 00" CENTER TO CENTER OF COLUMNS, ADJACENT TO ANY OPENING EXCEEDING 4'- 00" IN WIDTH AND AT THE END OF FKEE STANDING WALLS EXCEEDING 2'- 00" IN LENGTH. WHEN OPENINGS EXCEED 8' -00" IN WIDTH, TIE COLUMNS SHALL BE PRO- VIDED ON EACH SIDE OF ALL SUCH OPENINGS. ALL GABLE AND SHED END CORNERS SHALL HAVE TIE COLU- MNS. WHEN OPENINGS ARE BETWEEN 3' -00" AND 8' -00" IN WIDTH, SUCH OPENINGS SHALL HAVE ONE � 5 VEKTI- CAL REINFORCING BAR AT EACH SIDE, TIE BEAMS: ALL TIE BEAMS SHALL HAVE FOUR # 5 VERTICAL MINI- MUM AND # 3 TIES @ 12" C/C AT CORNERS AND EACH BEND AT 48" C/C ELSEWHERE. A TIE BEAM SHALL NOT BE LESS IN DIAMEN51ON OR REINFORCING THAN RE- QUIRED FOR THE CONDITIONS OF LOADING. CONTINUITY SHALL BE PROVIDED AT CORNERS ADDING 2 # 5 BENT BARS WHICH EXTEND 30" EACH WAY FROM THE CORNER. HORIZONTAL REINFORCING IN WALLS: SHALL BE PROVIDED AT EVERY SECOND COURSE ( I G" VERTICALLY) FOR ALL EXTE- RIOR WALLS. STANDARD # 8 LADDER TYPE FOR REIN- FORCING MASONRY AND TRUSS TYPE FOR ALL OTHERS SHALL BE PROVIDED. THIS REINFORCEMENT SHALL EXTEND 4" INTO COLUMNS. :NEW •� N � eJ v,,, y y.. FIRESTOP CONTINUITY 1'8" x 12" CONC. TIE ' BK W/ (4)45 #3' 48" O.C. NOTE: 112" GYP. BD. APPLIED I'st (4) #3- ;TO BE @ C7 TO I" x 2" P.T. FURR. :.1 2" O.C. @ CORNERS .. STRIPS @ 24" O.C. REINF. MASONRY STL. BEYOND'k R -5.0 INSUL. BETW. STRIPS ` EXT. 3/4" STUCCO «' WD. BASEBD. 112" EXP. JT. 4" THK. CONIC. SLAB W 1 G "xG "x #10WWM ON G MIL. POLYETHYLENE VAPOR BARRIER COMPACT FILL TO J5 07- PROCTOR r �a IPA F N. GK4DE 00 MAX. DENSITY I G "X 12" W12 #5 CONT. ` (TYP). MIN. CLEAR REQ'D.(TYP). •i •• TYP. WALL SECTION N.T.S. ru , "11'x' 4i.G•• v 4 V V • I ii i V � iG•••• VV •V {, V V J • r U iiV• . . V• V y r • • •cuc i i�` , • r v • • �t � V .. • 4u ••io • V �+ G •V'i VuGV Urii � rt, l+ V �`�' ql i i b • b=2 PROPOSED NEW ADDITION*%' - - FOR: Mr. & Mrs. GONZALES„r' r 7861 S.W. 68 th AVE.,MIAMI, FL. X33143 - -- - ' --_ ROOF PLAN & DETAIL'S YR DRAWN BY: I.G 'k• 5/8 "" PLYWOOD SHEATHING NAILED TO RAFTERS @ G" O.C. " W/ I Od NAILS, SHEATHING TO BE COVERED W/ 43# BASE SHEET T.C., COV. W/ 2 -PLY FIBERGLASS HOT MOPPED f' TOPPED W/ ALUM. COATING OR CAP SHEET I " SLOPE PER FT. /3" x 3" 26 GA�,,N1�L. SAVE F� DRIP �w , 2" x10" WD. JOISTS @ 24" O.C. "' x 2" WD. BLOCKING,;�Y INS. BATT (R -1 9) 0. H. 2" x 12" P.T. WD. F,,ACIA i „r 30# FELT * MTL*'•RI,B. LATH 1/2" GYP. BD. ON COV. W/ EXT. STUCCO I " x 3" WD. FURR. 3 "X22" VENT $ INSECT SCREEN @ 48" V-3,; ,. STRIPS @ 24" O.C. NOTE: PROVIDE (2) #5'Rx GO" LONG BENT I " x 4" P.T. WD. CORNERS (30" EA. WAY) FIRESTOP CONTINUITY 1'8" x 12" CONC. TIE ' BK W/ (4)45 #3' 48" O.C. NOTE: 112" GYP. BD. APPLIED I'st (4) #3- ;TO BE @ C7 TO I" x 2" P.T. FURR. :.1 2" O.C. @ CORNERS .. STRIPS @ 24" O.C. REINF. MASONRY STL. BEYOND'k R -5.0 INSUL. BETW. STRIPS ` EXT. 3/4" STUCCO «' WD. BASEBD. 112" EXP. JT. 4" THK. CONIC. SLAB W 1 G "xG "x #10WWM ON G MIL. POLYETHYLENE VAPOR BARRIER COMPACT FILL TO J5 07- PROCTOR r �a IPA F N. GK4DE 00 MAX. DENSITY I G "X 12" W12 #5 CONT. ` (TYP). MIN. CLEAR REQ'D.(TYP). •i •• TYP. WALL SECTION N.T.S. ru , "11'x' 4i.G•• v 4 V V • I ii i V � iG•••• VV •V {, V V J • r U iiV• . . V• V y r • • •cuc i i�` , • r v • • �t � V .. • 4u ••io • V �+ G •V'i VuGV Urii � rt, l+ V �`�' ql i i b • b=2 PROPOSED NEW ADDITION*%' - - FOR: Mr. & Mrs. GONZALES„r' r 7861 S.W. 68 th AVE.,MIAMI, FL. X33143 - -- - ' --_ ROOF PLAN & DETAIL'S YR DRAWN BY: I.G