05-1525(2)-0084" O MTL DI
GAUGE) PRC
DAMPER (N(
2" CD, LINE TC
OF STRUCT.
TERMINATED F
G" ABV. GRAD
NOTE:
EF.: " NUTONE" 50 CFM. EXH. FAN UP TO
ROOF JACK 4" COND. (FLEX)
(SEE EXHAUST FAN ROOF CAP DETAIL)
2" CD. LINE TO
OF STRUCT.
TERMINATED F,
G" ABV. GRAD[
EXTERIOR.
CAP FOR FUTURE
CONNECTION 50LAR
OR HEAT RECOVERY
GATE VALVE
H.W. TO FIXTURE5
HOT WATER, 3/4"
H EAT TRAP
GATE VALVE
COLD WATER, 3/4"
PRE55URE t TEMPERATURE
RELIEF VALVE (A5ME APPRVD.)
3/4" Cu RELIEF D15CHARGE
LINE, TO OUT5IDE GREEN
AREA, TERMINATE G"
ABOVE FIN. GRADE
WATER HEATER PIPING DIAGRAM
NO SCALE
PLUMBING NOTES:
I . ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE
LATEST EDITION OF THE FLORIDA BUILDING CODE, CHAPTER 4G I
LOCAL ORDINANCES, AND IN COMPLIANCE WITH THE FLORIDA ENERGY
EFFICIENCY CODE, FOR BUILDING CONSTRUCTION
2. CONTRACTOR TO VERIFY AT SITE, LOCATION FOR THE ELEVATION AND 512E
OF EXISTING SEWER AND WATER MAINS FOR THE CONNECTION OF NEW
SERVICES BEFORE INSTALLATION OF ANY PIPING.
3. PROVIDE SHUT -OFF AND VACUUM BRAKER TO ALL HOSE BIBS AND FAUCETS
WITH H05E -END CONNECTIONS.
4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR
CHAMBERS OR SHOCK ABSORBERS.
5. PLUMBING FIXTURES SHALL BE AS PER EQUIPMENT SCHEDULE, OR APPROVED
EQUAL. ALL FIXTURE TRIM SHALL BE CHROME PLATED. FIXTURES SHALL
BE PROVIDED WITH SUPPORTS, HANGERS, ETC.
G. WASTE LINES SHALL SLOPE 114" PER FOOT, UNLESS OTHERWISE NOTED.
7. VENT LINES SHALL EXTEND 5" MIN. ABOVE ROOF, AND FLASHED WITH LEAD
OR CONNECTED TO EXISTING VENT LINES.
8. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF
THE TRAP,
9, CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS,
MODIFICATIONS TO EXISTING CONDITIONS, LOCATIONS, AND DIMENSIONS
AFFECTING MIS WORK, AS SHOWN AND /OR NOTED ON THE PLANS.
10. ALL WORK SHALL CONFORM TO THE FLORIDA BUILDING CODE, NFPA.
AND U.L. REQUIREMENTS.
I I . CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR A
PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY THE OWNER.
CONTRACTOR SHALL REPLACE ALL DEFFECTIVE MATERIALS AND INFERIOR
WORKMANSHIP FOR THE GUARANTEE PERIOD AT NO COST TO THE OWNER
INCLUDING ALL LABOR REQUIRED TO CORRECT THE DEFECTIVE WORK.
12. CONTRACTOR SHALL SECURE ALL PERMITS AND PAY ALL FEES REQUIRED TO
PROCCE5 THE WORK.
WATER HEATER NOTES:
I . A HEAT TRAP IS DEVICE CONSISTING OF A DOWNWARD BEND LOCATED AS
CLOSE AS POSSIBLE TO THE WATER HEATER OUTLET, DESIGNED TO PREVENT
THE CONVECTION OF HEAT FROM A HOT WATER TANK THROUGH THE HOT
WATER DISTRIBUTION LINE IN A NON -RECIRCULATING SYSTEM.
2. IF SPACE PERMITS, M =G ", IF NOT PROVIDE 3 -1/2" MIN.
3. IN LIEU OF THE HEAT TRAP DESCRIBED IN NOTE # 1, THE PLUMBER MAY
SUBSTITUTE AN INTERGRAL BALL CHECK VALVE ON THE HOT WATER OUTLET
AND COLD WATER INLET AS MANUFACTURED BY A.O. SMITH.
4. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE.
5. PROVIDE VACUUM RELIEF VALVE.
G. DISCHARGE OUTSIDE G" ABOVE GROUND.
7. ALL DOMESTIC HOT WATER PIPING SHALL BE COPPER/ CPVC
PLUMBING FIXTURE SCHEDULE
UNIT DESIGNATION
FIXTURE TYPE
TRAP
SIZE
C.W.
H.W.
DESCRIPTION
ESYMBOL
WATER CLOSET
3"
\"
—
4,500 W
C
LAVATORY
1 \"
\"
\"
1 -60 -240
LOCATION
BATH TUB
2"
\"
\"
w/ ANTI —SCALD VALVE
SHOWER
2"
\"
\"
w/ ANTI -SCALD VALVE
❑ °�
KITCHEN SINK
1 \"
\"
\"
w/ GARBAGE DISPOSAL
r •
DISHWASHER
*
_
\„
DISCHARGE INTO GARBAGE
DISPOSAL UNIT.
FD
WASHING MACHI.
2"
\"
\"
• r
NOTE: ALL DRRAIN PIPING UNDER SLAB SHALL BE 2" MIN
2" do LESS DIA DRAIN @ 1/4" DROP
3" do 4" DIA DRAIN @ 1/8" DROP
EXIST. ELECTRIC WATER HEATER SCHEDULE
UNIT DESIGNATION
WATER HEATER –_1
MANUFACTURER
LOCHINUAR OR EQUAL
MODEL No.
KTA040KK
_
GALLONS CAPACITY
50 GALS
SERVICE TEMPERATURE
120
UPPER ELEMENT
4,500 W
LOWER ELEMENT
4,500 W
TOTAL WATTS
4,500 W
ELECT. SERVICE AVAILABLE
1 -60 -240
LOCATION
SHOWN
REMARKS: * NON SIMULTANEOUS WIRING
EF= .89 REQ'D
PLUMBING LEGEND
CTG
c-�
VTR
—� FCO
SANITARY SEWER LINE
CLEANOUT TO GRADE
COLD WATER (C.W.) LINE
HOT WATER (H.W.) LINE
GATE VALVE
HOSE BIBB
VENT THRU ROOF
FLOOR CLEAN OUT
PROPOSED NEW ADDITION
FOR: Mr. & Mrs. GONZALES
7861 S.W. 68 th AVE.,MIAMI, FL. 33143
WATER PLAN
DRAWN BY: LG
0 L.
9 • Y
+•Y
•
•
•
.�
Of
r
Y •
Y
• y
•rr•,
ri •
•
•
•
•
t _
•
v r
• w
r •
.••z Y
• r
•ii••U
....
Y
• y
Y •
• (i •i'G
•G, L
• Y
• y •
G
C
•
PROPOSED NEW ADDITION
FOR: Mr. & Mrs. GONZALES
7861 S.W. 68 th AVE.,MIAMI, FL. 33143
WATER PLAN
DRAWN BY: LG
0 L.
9 • Y
+•Y
•
•
•