05-1525(2)-005TYPE: LOAD: CENTER 150 AMC 5 PANEL: "N' I PHA5E 3 WIRES 5ERVICE: LIGHT5 / APPLIANCES 10.000 AIC 120/240 V SOLID NEUTRAL VOLTAGE. 240/120 V, 10 3W AMPS. POLES V.A COND WIRE REMARKS CKT No CKT Na REMARKS WIRE COND. V.A POLES AMPS. 50 2 7500 3/4 G AHU #1 I 2 DRYER 8 3/2 GO00 2 40 50 2 5000 3/4 G ACC #1 3 q 5 G H.W,H G 3/2 5000 2 50 SPACE 7 8 20 1 GOO 112 12 WASHER 9 10 -SMALL AP. 12 112 1 500 1 20 50 2 800 1 G RANGE 11 ! 2 SMALL AP. 12 112 1 500 1 20 13 14 DINING RECEPT. 12 1/2 1:500 I 20. 15 I G GEN. LIGHTS FAMILY 12 112 GOO I 20 20 1 1200 112 12 DI5HWA5HER 17 18 GEN. LIGHTS LIVING 12 112 GOO 1 20 20 1 GOO 112 12 COMPACTOR 19 20 GEN, LIGHTS ENTRANCE 14 112 500 1 15 20 1 750 I12 12- REFRIGERATOR 21 22 GEN. LIGHTS C'ORRIDOF. 14 112 500 1 15 20 1 GOO 112 12 PLAYROOM 23 24 GEN, LIGHTS GROUND. 12 1/2 GOO I 20 20 I 500 I /2 14 PLAYROOM 25 2G GEN. LIGHTS LIGHTS 12 I /2 GOO I 20 20 1 GOO 112 12 TOILETS 27 28 GEN. LIGHTS LIGHTS 12 112 GOO 1 20 15 1 500 112 14 BEDROOM 29 30 GEN. LIGHTS TOILET 12 112 600 1 20 15 I 500 112 14 BEDROOM 31 32 MASTER BR. 14 112 500 1 15 20- 1 GOO 112 12 GEN. LT9. 33- 34 MASTER BR. 14 112 500 1 15 _ 15 1 500 1/2 12 GEN. LT5 3..5 3G SPACE 20 1 GOO 112 12 SMALL APP. 37 38 SPACE 20 1 GOQ 112 12 BATHROOM 39 40 5PACE' TOTAL CONN. LOAD: 39.750 W. r/ D I _ � 1 REP. I C Ki I=XAl f 1 ELECTRICAL NOTES: 1. OUTSIDE RECEPTACLES, RECEPTACLES AT BATH, GARAGE AND '. G FEET FROM KITCHEN SINK, SHALL BE G.F.I: 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM NON- SWITCHABLE NO G.F.I. LIGHTING CIRCUIT INTERCONNECTED AND WITH BATTERY BACK -UP. 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER SERVICE ENTRANCE LOCATION. 4, ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. 5. ALL "J" BOXES SHALL COMPLY WITH N.E.C. 370 -1 7A. 3 # 1/0 (CU) THWN --2'G I' ,I 150 METER CAN PNL I' # 1/0 GRID CU -112" C a TO CWP- 40 CIRC. 2 -5/8 "X I O'CU GRIND RD. 2 P/ 150 A I j NEC- 250 -50 (C __ DISC. NtMA 3R. NOTE: EXIST. FOOTERS r (10 K A G) 3 # 1/0 # 8 (GRID) ! IN HOUSE (CU) THWN IN 2" C 2 112" # DOWN PIPE FOR POWER C.O. SECONDARY SERVICE CONDUCTORS VERIFY WITH POWER CO, 5EFORE COMMENCING WORK ELEC`TLRICAL RISER DIAGRAM NOTE: ALL WIRING 5HALL BE COPPER THWN G MAX I MUM NU MBER OF OUTLETS PER CIRCUIT SHALL COMPLY WITH S.F.B.C, 1990 . DADE COUNTY EDITION (TABLE 45 -A). 7. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW - t : � � ° _ �B A E F LOOD, ELEVATION SHA LL BE INSTALLS AT THE Go , HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED o k i c ON (SEPARATE) INDEPENDENT CIRCUITS FROMTHEOSE IN 0Uc THE HABITAL AREAS, Q Q U ", G 8, NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE r F INSTALLED BELOW BASE FLOOD ELEVATION.i ,h? w 9. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION 10. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION, PROPOSED NEW ADDITION FOR IT 1S SUGGESTED THAT YOU CONFER WITH FLORIDA POWER y" Mr. Mrs. GONZALES AND LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY 7861 S.W. 68 th AVE.,MIAM , EL. 33143 A REQUIREMENTS WITH FEDERAL EMERGENCY MANGEMEN T AGENCY _ _._ -.... _.__... __ -- - ' ELETR CAL PLAN DRAWN BY LG :x