GENERAL NOTES:
I.-WORKS PERFORMED SHALL COMPLY WITH THE FOLLOWING
A) ALL NOTES WRITTEN ON ALL SHEETS AND / OR PLANS
OF THE PRESENT PROJECT.
B) ALL APPLICABLE LOCAL, COUNTY OR STATE ORDINANCE,
2.g ON 51TE VERIFICATION OF ALL DIMEN51ONS AND CONDITIONS
SHALL BE RESPONSIBILITY OF THE CONTRACTOR,
3.- IT SHALL BE RE5PON51E31LITY OF THE GENERAL CONTRACTOR
TO VERIFY WITH THE ENGINEER IN WRITING ANY 0M155ION5 OR
DISCREPANCIES ARISING FROM THE INFORMATION CONTAINED
WITHIN THESE SPECIFICATIONS AND DRAWINGS,
4.- CONTRACTOR AND SUBCONTRACTOR SHALL COMPLETELY
FAMILIARIZE THEMSELVES WITH EXISTING SITE CONDITIONS AND VERIFY
THE LOCATION AND AVAILABILITY OF ALL UTILIES PRIOR TO
SUBMITTING BID.
5.-- CONTRACTOR SHALL BE RESPONSIBLE FOR THE DE51NG AND
CONSTRUCTION OF THE FORMWORK:
G.- IF ANY D15CREPANCIE5 ARE FOUND; STOP WORKING AND CONTACT
THE OWNER * THE ENGINEER.
NOTE DOORS
2 I -2.4. 1 NO DOORS IN THE PATH OF TRAVEL OF MEAN SCAPE
SHALL BE LE55 28' 1 h.
DOOR SHALL BE MIN G' -G" (2m) NOMINAL HT.
2 1.2.4-3. EVERY CL05ET DOOR LATCH SHALL BE SUCH CHINDREN CAN OPEN
THE DOOR FROM IN51DE THE CLOSET,
2 1 .2.4,4, EVERY BATHRM DOOR SHALL BE DE51NG TO ALLOW OPENING FROM
THE OUTSIDE DURING AN EMERGENCY WHWN LOCKED
SECURITY AND FORCED ENTRY PREVENTION
I.-PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH
IN CHAPTER 3G OF THE FLORIDA BUILDING CODE
2.- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPA13LE OF RE515TIN5 A
FORCE OF 300 LB. APPLIED IN ANY MOVEA13LE DIRECTION AND IN
ACCORDANCE WITH RE515TANCE 5TANDAR5 SET FORTH IN THE FLORIDA
BUILDING CODE,
3,-:ALL SINGLE EXTERIOR SWING DOOMS SHALL HAVE A LOCK TO BE KEY
OPERATED FROM THE EXTERIOR WITH A MINIMUN OF GOOO F0551BLE
KEY CHANGES OR LOCKING AUXILIARY 51NGLE DEAD BOLT WITH
HARDENED DOLT INSERTS;
4.- THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOOK5 SHALL HAVE
SAME; LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS THE
INACTIVE LEAF SHALL HAVE MULTIPLE POINTS OF LOCKS WITH 5 /6"
MIN. THROW BOLTS WITH INSERTS.
5,- HINGES ON EXTERIOR OUT 5WINGIN5 DOORS SHALL HAVE NON
REMOVABLE PINS AND NON - EXP05ED SCREWS.
,� G.- GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN
BAT
IL NATIONAL 5TANDAR5 INTITUTE'S STANDARS 297,
_ 7.- V151ON PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF
ro
THE IN51DE LOCKING ACTIVANTING DEVICE OF L005E AND SWING DOORS
SHALL COMPLY WITH THE AMERICAN NATIONAL`STANDARS INTITUTE5
STANDARS 297.1
8, SLIDING GLA55 DOORS AND WIND, SHALL DE IN5T. AND CON5T. SO THAT
NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION
w.ijc� AND 50 AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MAG5,
I ASSOCIATION STANDARS FOR FORCE ENTRY RESISTANCE, AAMA 13.33
- — PROVIDE LOCKS AS PER FBC 3GO32 (A) (B) 2 (AA) AND (C) EXTERIOR
WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITH5TAND(NGA
FORCE OF 150 LB, APPLIED IN AN OPERABLE DIRECTION,
10.- EXTERIOR WINDOW USED AS A MEANS OF ESCAPE SHALL ALSO COMFY
EXISTING E WITH A DOOR SCOPE OR V151ON PANELS: