Loading...
08-1279-008I GENERAL NOTES: 1. THE CONTRACTOR SHALL VISIT THE PREMISES AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL DETAILS OF THE WORK AND WORKING CONDITIONS. VERIFY ALL DIMENSIONS IN THE FIELD, AND ADVISE THE ARCHITECT / ENGINEER OF ANY DISCREPANCY BEFORE PERFORMING THE WORK. 2. THE CONTRACTOR SHALL PERFORM ALL WORK REQUIRED UNDER THIS CONTRACT FOR A COMPLETE INSTALLATION AND IN SUCH MANNER THAT SURFACES NOT AFFECTED BY REMOVAL OF EXISTING OR FROM NEW WORK SHALL REMAIN UNDISTURBED AND NORMAL ACTIVITIES AT THE INSTALLATION MAY CONTINUE WITH THE LEAST POSSIBLE INTERFERENCE ALL DEBRIS SHALL BE REMOVED FROM THE SITE OF THE WORK AT THE END OF EACH WORKING DAY. MATERIALS AND EQUIPMENT SHALL BE STORED ONLY AT LOCATIONS APPROVED BY THE ARCHITECT / ENGINEER AND OWNER'S REPRESENTATIVE. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE STRUCTURES AND PERSONNEL DURING THE WORK UNDER THIS CONTRACT. ALL ALTERING, CUTTING, DRILLING OF PAVEMENT, FLOOR AND OTHER MODIFICATIONS SHALL BE NEATLY AND CAREFULLY DONE BY SKILLED MECHANICS. 4. THE CONTRACTOR SHALL 15E RESPONSIBLE FOR ALL DAMAGE TO EXISTING WORK, MATERIALS, AND EQUIPMENT AS A RESULT OF HIS OPERATIONS. ALL DAMAGED WORK SHALL BE REPAIRED OR REPLACED WITH MATERIALS OF LIKE TYPE, QUALITY AND FINISH BY SKILLED MECHANICS OF THE TRADES INVOLVED AT NO ADDITIONAL COST TO THE OWNER AND TO-THE FULL SATISFACTION OF THE ARCHITECT / ENGINEER. 5. DISPOSAL OF ALL MATERIAL NOT SPECIFIED OR SHOWN TO BE SALVAGED AND / OR REUSED RESULTING FROM REMOVAL OPERATIONS SHALL BETHE RESPONSIBILITY OFTHE CONTRACTOR. ALL COSTS IN CONNECTION WITH DISPOSING OF THE MATERIALS WILL BE AT THE CONTRACTOR'S EXPENSE. ALL LIABILITY OF ANY NATURE RESULTING FROM THE DISPOSAL OF THE MATERIALS.WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 6. CONTRACTOR SHALL PROVIDE AND MAINTAIN ACCESS TO ALL EXISTING FACILITIES AND THOSE UNDER CONSTRUCTION IN THE IMMEDIATE VICINITY, AT ALL TIMES DURING CONSTRUCTION OF PROPOSED PROJECT. CONTRACTOR SHALL INSTALL SECURITY FENCING AND BARRICADES AS REQUIRED BY THE LOCAL AUTHORITIES, AND /OR DIRECTED BY ARCHITECT/ ENGINEER. a. VERIFICATION OF EXISTING CONDITIONS: EACH CONTRACTOR SHALL DETERMINE AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE BUILDING SITE AND SHALL QE RESPONSIBLE FOR SAME BEFORE COMMENCING THE WORK. DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT AND /OR ENGINEER AND SHALL BE RESOLVED BEFORE RESUMING THE WORK. DIMENSIONS SHALL BE READ AND NEVER SCALED OR ESTIMATED FROM THE ARCHITECTURAL DRAWINGS. 9. CODE COMPLIANCE: EACH CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OFTHE FLORIDA BUILDING CODE 2004, SUPPLEMENT 2005, AND WITH ALL OTHER CODES AND GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER HIS PORTION OF THE WORK. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURE'S AND FOR SAFETY PRECAUTION AND PROGRAMS IN CONNECTION WITH HIS PORTION OF THE WORK. 10. EXAMINATION OF THE CONTRACT DOCUMENTS AND SITE: EACH CONTRACTOR FOR THIS PROJECT SHALL STUDY AND FAMILIARIZE HIMSELF WITH THE SITE AND WITH ALL THE DRAWINGS FOR ALL TRADES AND PARTS OF THE WORK. SHOULD ANY CONTRACTOR HAVE THE OPINION THAT THERE EXISTS IN THE ARCHITECTURAL DRAWINGS ANY ERRORS OR DISCREPANCIES, OR THAT CONDITIONS OF THE WORK OF ANY OTHER CONTRACTOR IS SUCH THAT IT WILL PREVENT HIM FROM COMPLETING HIS WORK IN A COMPETENT MANNER, HE SHALL NOTIFY THE ARCHITECT OF SUCH BEFORE PROCEEDING WITH HIS WORK. THE CONTRACTOR SHALL HAVE AT THE BUILDING SITE, FROM START TO FINISH OF CONSTRUCTION, A RESPONSIBLE FOREMAN. IN ADDITION, THE CONTRACTOR SHALL GIVE HIS PERSONAL SUPERVISION TO THE WORK. THE FOREMAN SHALL BE ON DUTY DURING ALL WORKING HOURS. ANY INSTRUCTIONS. OR NOTICES GIVEN TO HIM SHALL HAVE THE_ SAME IMPORTANCE AS IF GIVEN TO THE CONTRACTOR IN PERSON. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING. TEMPORARY PROVISIONS SUCH AS TOILETS, WATER SUPPLY, LIGHT AND POWER AS WELL AS ANY OTHER DEEMED NECESSARY FOR THE COMPLETION OF THE BUILDING. ANY ITEM OF WORK NECESSARYTO THE PROPER COMPLETION OF CONSTRUCTION WHICH IS NOT SPECIFICALLY COVERED IN THESE DOCUMENTS SHALL BE PERFORMED IN A MANNER DEEMED GOOD PRACTICE OF THE TRADE INVOLVED. TERMITE PROTECTION NOTES TERMITE PROTECTION. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, THE INITIAL CHEMICAL SOIL TREATMENT INSIDE THE FOUNDATION PERIMETER SHALL BE DONE AFTER ALL EXCAVATION, BACKFILLING AND COMPACTION IS COMPLETE. IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SOILAREA DISTURBED AFTER INITIAL CHEMICAL SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL TREATMENT, INCLUDING SPACES BOXED OR FORMED, IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SPACE IN CONCRETE FLOORS BOXED OUT OR FORMED FOR THE SUBSEQUENT INSTALLATION OF PLUMBING TRAPS, DRAINS OR ANY OTHER PURPOSE SHALL BE CREATED BY USING PLASTIC OR METAL PERMANENTLY PLACED FORMS OF SUFFICIENT DEPTH TO ELIMINATE ANY PLANNED SOIL DISTURBANCE AFTER INITIAL CHEMICAL SOIL TREATMENT. IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CHEMICALLY TREATED SOIL SHALL BE PROTECTED WITH A MINIMUM 6 MIL. VAPOR RETARDER TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS 15EFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED, ANY WORK, INCLUDING PLACEMENT OF REINFORCING STEEL, DONE AFTER CHEMICAL TREATMENT UNTIL THE CONCRETE FLOOR IS POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID PENETRATING OR DISTUBING TREATED SOIL. IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CONCRETE OVERPOUR OR MORTAR ACCUMULATED ALONG THE EXTERIOR FOUNDATION PERIMETER SHALL BE REMOVED PRIOR TO EXTERIOR CHEMICAL SOIL TREATMENT, TO ENHANCE VERTICAL PENETRATION OF THE CHEMICALS. IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CHEMICAL SOIL TREATMENTS SHALL ALSO BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1 FOOT (305 MM) OF THE PRIMARY STRUCTURE SIDEWALLS. ALSO, A VERTICAL CHEMICAL BARRIER SHALL BE_APPLIED PROMPTLYAFTER CONSTRUCTION IS COMPLETED, INCLUDING INITIAL LANDSCAPING AND IRRIGATION/SPRINKLER INSTALLATION. ANY SOIL DISTURBED AFTER THE CHEMICAL VERTICAL BARRIER IS APPLIED SHALL BE PROMPTLY RETREATED. 11. PERMITS, FEES AND TAXES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES LICENSES AND DEPOSITS AND BE LIABLE FOR ALLSTATE AND FEDERAL SALES TAXES, AND ALL OBLIGATION UNDER.THE FEDERAL SECURITY ACT. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL OBTAIN CERTIFICATES OF COMPLIANCE, APPROVAL OR ACCEPTANCE FROM ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK AND DELIVER THESE CERTIFICATES TO THE OWNER ALONG WITH OFFICIAL RECEIPTS FOR SAME. 12. PERFORMANCE OF WORK: NO SUBCONTRACTOR SHALL BEGIN HIS WORK UNLESS THE PREVIOUS TRADES, UPON WHOM HE IS DEPENDENT, HAS PERFORMED THEIR WORK SATISFACTORILY ACCORDING TO THE PLANS AND SPECIFICATIONS. ONCE THE CONTRACTOR HAS STARTED HIS WORK, HE ASSUMES FULL RESPONSIBILITY FOR THAT WORK, BOTH FOR MATERIALS AND LABOR PERFORMED, ALL SUBCONTRACTORS ARE RESPONSIBLE FOR REMOVING DEBRIS RESULTING FROM THEIR WORK FROM THE PREMISES. 13. CLEANUP: IN ADDITION TO THE REMOVAL OF ALL CONSTRUCTION DEBRIS FROM THE PREMISES, IT IS THE FINAL RESPONSIBILITY OF THE CONTRACTOR TO REMOVE ALL SMUDGES, SPOTS OF PLASTER, PUTTY, CAULKING COMPOUND, ADHESIVE, PAINT AND PENCIL MARKINGS, TAGS AND "DESTINATION LABELS NOT CALLED FOR AS BEING PERMANENT. THE CONTRACTOR SHALL ALSO CLEAN EACH AREA SEPARATELY, INCLUDING THE WASHING OF ALL WINDOWS AND VACUUMING OR WAXING OF ALL FLOORS, PRIOR TO HANDING THE COMPLETED PROJECT OVER TO THE OWNER. 14. MATERIALS: ALL MATERIALS SHALL BE NEW, AS CAI ED FOR IN THE DRAWINGS, AND THE BEST OF THEIR RESPECTIVE KINDS. NO SUBSTITUTIONS SHALL BE MADE BY THE CONTRACTOR WITHOUT PRIOR WRITTEN APPROVAL BY THE OWNER, UNLESS SPECIFIED OTHERWISE ON THE DRAWINGS. FOR PORTIONS OF THE WORK NOT SHOWN IN DETAIL., BUT WHICH ARE SHOWN GENERALLY, OR ARE REASONABLY INFERABLE AS BEING, REQUIRED FOR A COMPETENT AND COMPLETE INSTALLATION, THE MATERIAL METHODS AND WORKMANSHIP SHALL CONFORM AS A MINIMUM TO THE TYPICAL OR REPRESENTATIVE. 15_ FIRE'RESISTANCE / UNDERWRITERS LABORATORY RATINGS: WHERE ASSEMBLIES OR THEIR VARIOUS COMPONENTS, MATERIALS OR CONSTRUCTION SYSTEMS ARE INDICATED TO HAVE FIRE RESISTANCE RATINGS / UNDERWRITERS LABORATORY RATINGS., ALL SUCH SHALL BE COMPOSED OF MATERIALS AND BE ASSEMBLED SO AS TO CONFORM TO THE STANDARDS ESTABLISHED IN GOVERNING CODES IN ORDER TO ACHIEVE THE REQUIRED RATING IN THE COMPLETED WORK. 16. CUTTING AND PATCHING: EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CUTTING, FITTING, PATCHING AND MATCHING OF HIS NEW WORKTO EXISTING WORK WHERE APPLICABLE AND INDICATED IN THE DRAWINGS. NO CONTRACTOR SHALL ENDANGER ANY WORK OF ANY OTHER CONTRACTOR BY EXCAVATING CUTTING OR OTHERWISE ALTERING ANY WORK OF ANY OTHER CONTRACTORS. 17. DEMOLITION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF DEBRIS REQUIRED TO COMPLETE THE CONSTRUCTION AS SPECIFIED ON THE DRAWINGS. EXISTING UNUSED ELECTRIC AND PLUMBING SHALL BE REMOVED OR ADEQUATELY CAPPED AS ALLOWED BY CODE. TERMITE PROTECTION. ALL BUILDINGS SHALL HAVE PRE-CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE DEEMED AS APPROVED WITH RESPECT TO PRE - CONSTRUCTION SOIL TREATMENT FOR PROTECTION AGAINST SUBTERRANEAN TERMITES. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: 'THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES PENETRATION. PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL NOT ME OF CELLULOSE - CONTAINING MATERIALS AND SHALL RECEIVE APPLICATION OFA TERMITICIDE IN ANNULAR SPACE BETWEEN SLEEVE AND PIPE. GENERAL DEMOLITION NOTES 1. ARCHITECTURAL AND STRUCTURAL- CAREFULLY REMOVE AREAS OF WAIL, FLOOR AND /OR CEILING PRECISELY AS INDICATED SO AS NOT TO COMPROMISE ARCHITECTURAL OR STRUCTURAL INTEGRITY OF THE BUILDING OUTSIDE THE LIMITS OF DEMOLITION. PROVIDE 3K POST SHORING @ 48" O.C. @ ALL MANSONRY OPENINGS ENLARGED BY DEMOLITION OR IN LOCATIONS AS SHOWN ON PLANS. 2. MECHANICAL- DISCONNECT AND REMOVE ALL DUCTS, FANS AND ASSOCIATED CONTROLS FROM AREA OF WORK DEMOLITION AND REMOVAL OF ALL HVAC EQUIPMENT SUBJECT TO APPROVAL OF MECHANICAL ENGINEER OF RECORD AND OWNER'S MEP. 3. ELECTRICAL- DISCONNECT AND REMOVE ALL SWITCHES, RECEPTACLES, FIXTURES, DEVICES, ASSOCIATED, WIRING AND TELEPHONE WIRING JACKS WITHIN LIMITS OF DEMOLITION AS SHOWN ON PLANS. 4. PLUMBING- DISCONNECT AND REMOVE ALL FIXTURES, DEVICES AND ASSOCIATED CONTROLS, PIPING AND FITTING IN THE AREA OF WORK. CAP OFF WASTE VENT AND SUPPLY PIPING SO AS NOT TO INTERFERE WITH THE WORK OF OTHER SPACES. DEMOLITION AND REMOVAL OF ANY AND ALL PLUMBING IS SUBJECT TO APPROVAL BY PLUMBING ENGINEER AND OWNER'S REP. SECURITY NOTES: APPLICABLE ITEMS FBC RE: INTRUSION AND BURGLARY SECURITY 1.) ALL LOCKS ON EXTERIOR DOORS SHALL DE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN METRO CODE 360. 2.) ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM EXTERIOR WITH A MIN. OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY 3.) THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE INACTIVE LEAF OF THESE PAIRS OF DOORS SHALL HAVE MULTIPLE POINT LOCKS WITH 3/5" MIN: THROW BOLTS WITH INSERTS. 4.) HINGES ON EXTERIOR OUT-SWINGING DOORS SHALL HAVE NON- REMOVABLE PINS. 5.) JAMBS OF ALL EXTERIOR OFFSETTYPE INSWING DOORS BE RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF LOCKS AND LATCHES. 6. SINGLE, SWINGING, EXTERIOR DOORS, IF USED SHALL BE SOLID CORE OF NO LESS THAN 13/41 THICK.. 7.) GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS INSTITUTES STANDARD 297.1. _.) VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING WITHIN A0" OF THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE'S- STANDARD 297.1. 9.) SLIDING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MFG'S ASSOCIATION STANDARDS FOR FORCED ENTRY RESISTANCE, AAMA 1303.3. 10.) FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANEL 11.) DOOR AND WINDOWS BY CARADCO PRODUCTS (OR EQUAL) ABBREVIATIONS: • •.• • A ANCHOR HT HEIGHT A/C AIR CONDITIONING HORIZ HORIZONTAL ACOUST ACOUSTICAL H.B. HOSE BIBB ACP ACOUSTICAL CEILING PANEL I.D. INTERIOR DIMENSION A.F.F. ABOVE FINISH FLOOR INSUL INSULATION AL OR ALUM ALUMINUM INTERM INTERMEDIATE ANOD. ANODIZE JAN. JANITOR BD BOARD MANUF. MANUFACTURER B.F.F. BELOW FINISH FLOOR MAT MATERIAL BLKG BLOCKING MAX MAXIMUM BLK BLOCK MIN MINIMUM CEM CEMENT MTL METAL CER CERAMIC NIC NOT IN CONTRACT C.F.V. CONTRACTOR FIELD VERIFY NEOPR NEOPRENE C.J. CONTROL JOINT O.D. OUTSIDE DIMENSION CLG CEILING O.C: ON CENTER COL COLUMN O.S. OVERFLOW SCUPPERS CONC CONCRETE PTN PARTITION CONT CONTINUOUS Pi PANELJOINT COVER'G COVERING PL PLATE DBL DOUBLE L.P. LIGHT POLE DIM DIMENSION PLYWD PLYWOOD DTL/DTLS DETAILS PNL PANEL E.A. EACH PLAM PLASTIC LAMINATE ELECT/ELEC ELECTRICAL P.T. PRESSURE TREATED EL. ELEVATION REINF. REINFORCING ELEV. ELEVATOR REM REQUIRED EXH. EXHAUST RM ROOM EXIST. EXISTING R.D. ROOF DRAIN EXP. EXPANSION SHT SHEET EXT. EXTERIOR SCH SCHEDULE F.D. FLOOR DRAIN S.S. STAINLESS STEEL F.E. FIRE EXTINGUISHER STL STEEL FIRE EXT. CAB, FIRE EXTINGUISHER CABINET STD. STANDARD F.O.I.C. FURNISHED BY OWNER, SECT SECTION INSTALLED BY CONTRACTOR SIM SIMILAR FLUOR FLUORESCENT SPECS SPECIFICATIONS FIN. FINISH STRUCT STRUCTURE GA GAUGE SC SOLID CORE WOOD GWB GYPSUM WALL BOARD PH. TELEPHONE GYP. BD. GYPSUM BOARD TEMP TEMPERED GALV. GALVANIZED VCT VINYL COMPOSITION TILE GS GALVANIZED STEEL VERT VERTICAL GL GLASS VEST. VESTIBULE HM HOLLOW METAL SYMBOLS: NORTH ARROW A COLUMN.REFERENCE GRIDS A WALL SECTION A1.1 DETAIL NO. SHT. ON WHICH DETAIL IS SHOWN OR SHT. ON WHICH DETAIL IS CALLED OUT SECTION NO. A BUILDING SECTION q Ai.i SHT. ON WHICH SECTION SHOWN OR SHT. ON WHICH SECTION IS CALLED OUT (PLAN, ELEVATION) WT WALL TYPE # ELEVATION NO. SHEET ON WHICH ELEVATION IS SHOWN DOOR No. #� WINDOW TYPE # ROOM NAME # ROOM No. # ELEVATION # NGVD RELATED NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED. f • • • • •.• • Y 00: • • *Q.. w w w ••• f Y • • Y u • u y W • V• i u v• i• V • Y W W `V • .40 u u • m U t M 0 z m m x • • u V V u J • V G i V W • . • W u i i v i f i W Vii , • . V V Viii y y Y i • W • • • • • V y Y y W • • • • soUrt� Cl i e b� otsG At. S�"- CfitOt� S'Cvjuclu� r� N w w w w M N Z w z N z m U t M 0 z m m x U Q _O�U Z 0 w 0 W La W x W c� 0 z K M is z U L � 4! W z 0 F 0 LA U L k znf oo t r z Z CONSULTING: N w w w z M N Z w z N z m U t M 0 z m m x U Q _O�U � 0 w 0 W La W x o c� � z K M is z U L � 4! Li ..B �J M M M L1- M ry M -_i U_ J m U t M W g m m � M Q _O�U K U X: Ld La o U M t N w a W LL F 0 U vi znf oo t :2 m Z 0 O z M t 0 0 � M n r= C O � A Li ..B �J M L1- M ry o w m U t M W g O (D cc x U M Q _O�U c to Li ..B �J w ll,� . •... '`c GENERAL N05 SCALE AS SHOWN DRA" jtt BALD DATE 11108 SHEET: A -6 6 OF:6