08-1279(2)-007TYPE: ITE SIEMENS PANEL A MAIN BUS: 20OMPS SERVICE: 10, 3W NEMA 311 NEUTRAL: FIN VOLTAGE: 120/240 V. 30 KAIC (SEE KAIC NOTE 14 MAIN: M.L.O. MOUNTING: FLUSH ON THIS SHEET) LOCATION: WALL K /VOLT AMP POLE TRIP CONDUIT WIRE REMARKS CKT. NO. WIRE CKT. NO. REMARKS WIRE CONDUIT TRIP POLE K /VOLT AMPS. 10.00 2 50 3/4" #6 AHU #1 (HEAT PUMP) + 1 2 CU #1 (HEAT PUMP) • #8 in 60 2 10.00 3 4 1.50 1 20 - -- #12 SMALL APPLIANCE 5 8 DRYER #10 3/4" 30 2 6.00 1.50 1 20 --- #12 SMALL APPLIANCE 7 8 1.50 1 20 - -- #12 REFRIGERATOR 9 10 18KW I.R.H. #3 1 1/4° 100 2 18.00 1.20 1 20 --- #12 WINE CELLAR 11 2 12 1.20 1 20 - -- #12 DISPOSAL 13 14 BATH GFCI #12 - -- 20 1 0.30 1.50 1 20 - -- #12 DISHWASHER 15 18 BATH GFCI #12 - -- 20 1 0.30 1.08 1 20 - -- #12 GENERAL LIGHTS ** 17 1 18 BATH GFCI #12 - -- 20 1 0.30 1.08 1 20 - -- #12 GENERAL LIGHTS ** 19 -- 20 GENERAL LIGHTS ** #12 - -- 20 1 1.08 1.08 1 20 - -- #12 GENERAL LIGHTS +* 21 2 22 GENERAL LIGHTS ** #12 - -- 20 1 1.08 1.08 1 20 - -- #12 GENERAL LIGHTS *+ 23 24 SECURITY LTS. (THRU TIMER) #12 - -- 20 1 1.08 1.08 1 20 --- #12 GENERAL LIGHTS 25 #8 26 GENERAL LIGHTS *+ #12 - -- 20 1 1.08 1.50 1 20 - -- #12 WASHER MACHINE 27 28 GENERAL LIGHTS *+ #12 - -- 20 1 1.08 1.08 1 20 - -- #12 GARAGE DOOR 29 30 KITCHEN LIGHTS #12 - -- 20 1 1.08 12.00 2 50 3/4" #6 RANGE 31 -- 32 LIGHTS '* #12 - -- 20 1 1.08 33 1 34 LIGHTS #12 - -- 20 1 1.08 1.20 1 20 - -- #12 KITCHEN EXHAUST 35 1 36 GARAGE RECEPTACLES /LTS #12 - -- 20 1 1.08 1.00 1 -- - -- #12 GARAGE DOOR 37 1 38 SPACE -- -- -- 1 --- 1.08 1 20 - -- #12 GENERAL LIGHTING (GFCI) 39 1 40 SPACE -- -- -- 1 --- 1.08 1 20 - -- #12 GENERAL LIGHTING 41 1 42 SPACE -- -- -- 1 - -- TOTAL CONNECTED LOAD: 71.47 KVA TOTAL CONNECTED LOAD WITH OUT CU 52.22 KVA ROMEX CABLE WILL BE ACCEPTED * NON COINCIDENT DEMAND LOAD (SEE LOAD CALCULATIONS): I =140 AMPS ** PROVIDE AFCI (ARC- FAULT) BREAKER IN ALL OUTLETS IN ELECTRICAL LEGEND $M 120 V TOGGLE SWITCH, SINGLE POLE. ( +48" AFF UNLESS OTHERWISE NOTED). VOLTAGE AS PER CIRCUIT DESIGNATION. LETTER "M" INDICATE MOTORIZED RATED. 3w 120 V THREE RAY TOGGLE SWITCH, SINGLE POLE. ( +48" AFF UNLESS OTHERWISE NOTED). VOLTAGE AS PER CIRCUIT DESIGNATION. DIMMER SWITCH, SINGLE POLE. ( +48- AFF UNLESS OTHERWISE NOTED.) LOAD AS PER CIRCUIT LOAD, DO NOT OVERLOAD DIMMER OVER 80R OF DIMMER RATED CAPACITY. GROUNDED TYPE DUPLEX RECEPTACLE, WALL. ( +18- AFF UNLESS OTHERWISE NOTED.) LETTER "D" DESIGNATION MEANS DEDICATED; LATTER "I" DESIGNATION MEANS ISOLATED GROUND. LETTER "E" MEANS EXISTING. (� GROUNDED TYPE DUPLEX RECEPTACLE, WALL. ( +4" ABOVE COUNTER UNLESS TT OTHERWISE NOTED.) LETTER -D- DESIGNATION MEANS DEDICATED; LATTER 'I" DESIGNATION MEANS ISOLATED GROUND. GROUNDED TYPE DUPLEX RECEPTACLE, WALL HALF SWITCHED. - JUNCTION BOX. INSTALL FAN TYPE JUNCTION BOX (FOR 60 LBS) IN ALL FANS. ®� TELEPHONE OUTLET, WALL. ( +18" AFF) TV T.V. OUTLET CABLE - - - CONDUIT CONCEALED IN OR UNDER FLOOR SLABS. CONDUIT CONCEALED ABOVE CEILING OR IN WALL. PANEL DISCONNECT SWITCH. 2 POLES, 240V ENCLOSED CIRCUIT BREAKER ECB -�- GROUND CONNECTION. Z. ELECTRIC MOTOR CONNECTION. K- WALL SCONCE (TO BE SELECTED) DELUXE SECURITY FLOOD LIGHTS -0- STD. SURF. MTD. FDIT. SD FIRE ALARM SMOKE DETECTOR ®VAPOR PROOF RECESSED HI HAT (FOR ALL BATH TUBS & SHOWERS) O DEDICATED COMPUTER PHONE LINE Og FIRE DETECTOR Q VOLUME CONTROL CEILING MOUNTED SPEAKERS (TO BE SELECTED BY OWNER) O DOOR BELL p VIDEO CAMERA SCREEN L� ALARM CONTROL PANEL TYPE: ITE SIEMENS PANEL B MAIN BUS: 150AMPS SERVICE: 10. 3W! NEMA 3R NEUTRAL: FIN VOLTAGE: 120/240 V. 30 KAIC (SEE KAIC NOTE 14 MAIN: M.L.O MOUNTING: FLUS ON THIS SHEET) LOCATION: WALL K /VOLT POLE TRIP CONDUIT WIRE REMARKS CKT. CKT. REMARKS WIRE CONDUIT TRIP POLE K /VOLT AMP N0. NO. AMPS. 8.00 2 50 1" #6 AHU #2 (HEAT PUMP) + 1 2 CU #2 (HEAT PUMP) $ in 40 2 8.00 3 4 1.08 1 20 -- #12 LIGHTS LIVING ROOM 5 $ yr /H #2 #10 3/4" 30 2 5.00 1.08 1 20 -- #12 GENERAL LTS. LIVING ROOM 7 8 POOL EQUIPMENT 9 10 LANDSCAPE GFCI #12 -- 20 1 1.08 11 12 SECURITY LIGHTS (THRU TIMER) #12 __ 20 1 1.08 3.00 2 -- -- -- (SEPARATE PERMIT) 1.00 1 20 1/2° #12 POOL LTS. (GFCI) 13 14 CU #3 (HEAT PUMP) 1 #8 1' 40 2 8.00 15 18 (J'a.00 2 40 in #8 AHU #3 (HEAT PUMP) + 1 1 17 18 SPACE - -- 19 20 SPACE -- -- -- 1 --- --- 1 -- -- -- SPACE 21 22 SPACE -- -- -- 1 - -- --- 1 -- -- -- SPACE 23 24 SPACE - -- -- 1 - -- --- 1 -- -- -- SPACE 25 26 SPACE -- -- -- 1 - -- --- i -- -- -- SPACE 27 28 SPACE -- -- -- 1 - -- --- 1 -- -- -- SPACE 29 30 SPACE -- -- -- 1 - -- --- 1 -- -- -- SPACE 31 32 SPACE -- -- 1 - -- TOTAL 23.18 22.18 TOTAL CONNECTED LOAD: 45.32 KVA TOTAL TOTAL CONNECTED LOAD WITH OUT CU 29.32 KVA ROMEX CABLE WILL BE ACCEPTED # NON COINCIDENT TOTAL CONNECTED LOAD: I =123 AMPS ** PROVIDE AFCI (ARC- FAULT) BREAKER IN ALL OUTLETS IN 1 ELEC'PRICAL PANELS AND LOAD CALCULATIONS Saar. ors L_ rm. CONSULTING: Iva N 0 ot w' U 3��� h �� y� N 0. h Cy `O �ti W A� A cn � M O = M E o� m N h 'E c Q Ii U O c: V) 00 "D M N Q M W o ***� ii Q M - d- Q CI. M Q ~ rn M U W O M � U ao O � Q 2. „2 _< 222 ti22 r=k �:fk k`h kk ik \ tow" kkx \, ik ��k2 E, NE � � x 4 • � a' . w'fi d, DAM 11-18-08 ELECTRICAL PANELS auut AS SHOWN oruwn 0 .�• 2oos SHEET: E -2 2 OF: 3 o ELECTRICAL PANELS auut AS SHOWN oruwn DFG .�• 2oos SHEET: E -2 2 OF: 3