05-1465-031COVER SECURED
WITH SCREWS
THREADED C.O. PLUG
FIN. GRADE
4 X 6" DIA. CONCRETE
PAD FLUSH W /FIN. GRADE SLIP JOINT
UL1479
UL2079
EXTERIOR TYPE
r'
ADJUSTABLE COLLAR
THREADED C.O. PLUG
FIN. FLOOR -7
FLOOR
TYPICAL CLEANOUT DETAIL
N.T.S.
UL FIRE RESISTANCE DIRECTORY :``
A. FILLS, VOIDS OR CAVITY MATERIALS
(XHHW)
B. FIRESTOP DEVICES (XHJI)
WALL
FAEOF
,.�. Tww'12
FIN. GRADE
STAINLESS ST�EL COVER 24" DIA. X 24" REINFORCED
1 CONCRETE PIPE
SCREWED TO THREADED -
C.O. PLUG. I I �°• °� °� ° - s CO D
I 89 a RAIN I
Ail
1I °
vo
oil
O BdJ I _
0° p
TO PERVIOUS RO&%. �P ®p ® � °°
�;P'� cl .. C A. g� a3� O O ° CLEAN LOOSE
PEA ROCK
FRENCH DRAIN DETAIL
nppPIIAIC AAIPI AIR" r`AKI'T RC7An nW cCAI AKIT Tin ❑C- A001 IC-n AT Aorne TREMSTOP MCR.
- ' "TREMCO'" FIODEL: �TREMSTOP W FOR ''I ' "" "" " "TREMCO" MODEL: TREMSTOP D FOR 2
OF POINT CONTACTOR 2 HOUR FIRE RATED PENETRATION HOUR FIRE RATED PENETRATION FOR
FOR SINGLE METALLIC PIPE THRU SINGLE PLASTIC PIPE THRU GYPSUM
GYPSUM WALL WALL
FIRE STOPPING DETAIL
N.T.S.
CHECK VAL
1 -1/4' HOT WATER SUPPLY 6
1-1/4" COLD WATER SUPPLY 9---�
[' RECIRCULATING o`
HOT WATER
SEE FLOOR PLAN
FOR CONTINUATION
AND RISER FOR PIPE SIZES
IN -LINE RECIRCULATING
PUMP LITTLE RED MFG.
LL -20 MODEL WITH
12' HEAD e 2 GPM, 1/20 HP
UNION (TYP.
AT
VACUUM RELIEF VAL
3/4" 1/2"
3/4" 3/
WATER D
HEATER I
EWH -1 —AIR
N.T.S.
HANGER SPACING
PIPING MATERIAL
MAXIMUM
HORIZONTAL
SPACING
MAXIMUM
VERTICAL
SPACING
5
5' (A)
15'
d
12'
10'
COPPER TUBING 1 1/4'0 AND LESS
6'
10'
COPPER TUBING 1 1/2 "0 AND OVER
.
10'
2
1 •
PRE -RATED GYPSUM WALLBOARD /STUD WALL ASSEMBLY
STEEL PIPE
3
15'
—� FCO
FLOOR CLEAN OUT
—�i CO
WALL CLEAN OUT
WHIRLPOOL BA'H
GATE VALVE
2•
PLASTIC PIPE - NOM. 4 "0 (OR SMALLER) SCH. 40 PVC PIPE FOR USE
HOSE BIBB
P -2C
IN CLOSED OR OPEN PIPING SYSTEMS. SEE TABLE BELOW FOR REQUIRED
1 • PRE -RATED GYPSUM WALLBOARD /STUD WALL ASSEMBLY
VV
ANNULAR SPACE.
CO--
3.
LAVATORY
2. METALLIC PIPE:
--III—
TREMSTOP WS - INTUMESCENT P STRIP, CONTINUOUSLY WRAPPED
A) STEEL PIPE - 12" 0 (OR SMALLER) SCH. 10 (OR HEAVIER) STEEL
�pBLW
AROUND OUTEPpj fe(jl1 EREN� F THE PI*.SEE TABLE BELOW FOR
PIPE.
CEILING
FLOOR
MIN. WRAPS REQUIRED. 3/1 fi WRAPS
B) IRON PIPE - 12 "0 (OR SMALLER) CAST OR DUCTILE IRON PIPE.
(UG)��
3
/8 4
C) COPPER TUBING - 4 "0 (OR SMALLER) TYPE L (OR HEAVIER) COPPER
VACUUM BREAKER
4 111
TUBING.
4,
TREMSTOP MCR - PREFABRICATED STEEL COLLAR WRAPPED OVER THE
D) COPPER PIPE - 40 (OR SMALLER) REGULAR (OR HEAVIER) COPPER
/2"
WRAP STRIPS (ITEM 3) AND MECHANICALLY FASTENED TO BOTH SIDES OF
PIPE.
3'
P -5B
WALL ASSEMBLY.
E) CONDUIT - 4"0 (OR SMALLER) EMT OR 6 0 (OR SMALLER) STEEL
1/2"
1/2"
CONDUIT.
5•
TREMSTOP 1A OR TREMSTOP ACRYLIC (OPTIONAL) - MIN %" BEAD OF
THE ANNULAR SPACE SHALL BE MIN. 0" TO MAX 1" WITHIN THE
1 /2"
SEALANT APPLIED AT THE WALLBOARD /DEVICE AND DEVICE /PIPE
FIRESTOP SYSTEM.
P -6A
INTERFACES.
TREMSTOPIA - MIN %" THICKNESS OF SEALANT APPLIED WITHIN
1/2"
NOTE: TREMSTOP D CAN BE USED IN PLACE OF TREMSTOP WS AND
nppPIIAIC AAIPI AIR" r`AKI'T RC7An nW cCAI AKIT Tin ❑C- A001 IC-n AT Aorne TREMSTOP MCR.
- ' "TREMCO'" FIODEL: �TREMSTOP W FOR ''I ' "" "" " "TREMCO" MODEL: TREMSTOP D FOR 2
OF POINT CONTACTOR 2 HOUR FIRE RATED PENETRATION HOUR FIRE RATED PENETRATION FOR
FOR SINGLE METALLIC PIPE THRU SINGLE PLASTIC PIPE THRU GYPSUM
GYPSUM WALL WALL
FIRE STOPPING DETAIL
N.T.S.
CHECK VAL
1 -1/4' HOT WATER SUPPLY 6
1-1/4" COLD WATER SUPPLY 9---�
[' RECIRCULATING o`
HOT WATER
SEE FLOOR PLAN
FOR CONTINUATION
AND RISER FOR PIPE SIZES
IN -LINE RECIRCULATING
PUMP LITTLE RED MFG.
LL -20 MODEL WITH
12' HEAD e 2 GPM, 1/20 HP
UNION (TYP.
AT
VACUUM RELIEF VAL
3/4" 1/2"
3/4" 3/
WATER D
HEATER I
EWH -1 —AIR
N.T.S.
HANGER SPACING
PIPING MATERIAL
MAXIMUM
HORIZONTAL
SPACING
MAXIMUM
VERTICAL
SPACING
CAST IRON
5' (A)
15'
COPPER PIPE
12'
10'
COPPER TUBING 1 1/4'0 AND LESS
6'
10'
COPPER TUBING 1 1/2 "0 AND OVER
10'
10'
PVC PIPE
4'
10' (8)
STEEL PIPE
12'
15'
A - SPACING SHALL BE 10' IF 10' LENGTHS ARE INSTALLED
B - MID STORY GUIDE FOR 2 00 AND LARGER
•.
CONC. SLAB '-CONC. INSERT
• yi
X3/8" ALL THREAD ROD
PIPE
PIPE RING HANGER
INSULATION FOR NOISE
PIPE HANGER
N.T.S.
GUY GRAY SPACE
SAVER W/3.5" DEEP BOX;
FOR METAL STUD WALL
°
I
HW & CW HOSE CONNEC-
s:., < TIONS W/VACUUM BREAKERS G
° <= (WATTS OR EQUAL)., '
•�A1�fROL MODEL 500
E " :'�A'iER HAMMER ARRES- ` -Y
1/2 HW & CW ` . '� t. , i, % ls TOR.
PPIPING.
2" DIA.-;
WASTE.
- FINISHED --
" FINISHED FLOOR I
..... ......... . .
- WASHING MACHINE DETAIL
- . N.T.S.
-3/4" THERMOMETER W/ GAGE COCK (TYP) "
SHUTOFF VALVE (TYPJ
A.S.M.E. APPROVED
D TEMPERATURE AND
PRESSURE REIEF VALVE (TYP)
WATER RELIEF PIPE -FULL
NEATER SIZE OF DISCHARGE
EWH -2 OPENING. (TYP)
--AIR GAP
-FL E
DRAIN VALVE (TYP)
• ° " • TO OUTSIDE
4" HIGH CONCRETE FINISH® FLOOR
PAD W/ CHAMFERS
ELECTRIC WATER HEATERS DETAIL
SCHEMATIC DIAGRAM N.T.S.
1 1/4'
PERFORATE
VENT CAP-
SLOPE, 1/87 FT.
12" MIN.
UNION
CONDENSATE TRAP DETAIL
N.T.S.
GENERAL NOTES:
1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE,
STATE AND LOCAL ORDINANCES.
2, BUILDING DRAINAGE SYSTEM TO BE SLOPED AT 1/8" PER FT. MIN. FALL FOR 3" PIPE AND
LARGER 1/4" PER FT. SLOPE FOR 2" PIPE SIZE AND SMALLER DEVIATIONS SHALL BE
APPROVED BY ARCHITECT /ENGINEER.
3. PROVIDE CLEAN OUTS EVERY 75 FT. AND AT BASE OF EVERY WASTESTACK.
ALL CLOSE -OUTS TO BE FLUSH MOUNTED.
4• MATERIALS SHALL BE ALL NEW AND AS FOLLOWS:
A. DRAINAGE WASTE AND VENT PIPING INCLUDING:
PVC DRAINAGE WASTE AND PIPING (DWV) CONFORMING TO
ASTM D -2665, UNDERGROUND NO HUB CAST IRON CISPI STANDARD 301
ABOVE GROUND AND CAST IRON HUB, PLAIN END ASTM A -74 WITH NEO-
PRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN
ITS APPROVED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR
RETURN PLENUM.
B. WATER PIPING: COPPER TYPE "L" ASTM B -88 ABOVE GROUND AND
COPPER TYPE "K" ASTM B -88 UNDERGROUND.
C. CONDENSATE DRAIN PIPING: COPPER TYPE "M" ASTM B -88 INSIDE
THE BUILDING AND PVC SCHEDULE 40 ABOVE ROOF AND UNDERGROUND.
PROVIDE 3/4" ARMAFLEX PIPE INSULATION TO ALL CONDENSATE DRAIN
PIPING.
D. GAS PIPING: BLACK STEEL SCHEDULE 40 ASTM -53
E. FLOOR CLEAN OUTS: JOSAM SERIES 56020 OR EQUAL.
F. WALL CLEAN OUTS: JOSAM SERIES 58750 WITH ACCESS COVER OR EQUAL.
H. VALVES: 125 PSI NIBCO SCOTT, STOCKHAM OR EQUAL.
I. HOSE BIBBS: CHICAGO 837 OR EQUAL WITH VACUUM BREAKER.
5, PERFORM THE FOLLOWING TEST:
A. WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF
100 PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM
BUT NOT LESS THAN ONE HOUR.
B. DRAINAGE SYSTEM: BEFORE INSTALLATION OF ANY DRAINS, THE END OF THE
SYSTEM SHALL BE CAPPED & ALL LINES FILLED WITH WATER TO HIGHEST
POINT & ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVELS
REMAIN CONSTANT.
C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTS.
D. COMPLETE SYSTEM FIXTURE & EQUIPMENT SHALL BE GIVEN AN IN SERVICE
TEST AFTER COMPLETION OF THE INSTALLATION.
E. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) POUNDS OF CHLORINATED
LIME TO EACH 1000 gal. OF WATER (50 PPM OF AVAILABLE CHLORINE.) RETAIN
MIXTURE IN PIPES FOR 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER
BEFORE PLACING IN SERVICE.
6• PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING
WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD
OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE, AND THAT HE WILL, AT HIS EXPENSE,
REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING GUARANTEE PERIOD.
7. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF EXISTING UTILITIES AND POINTS OF
CONNECTION BEFORE COMMENCING ANY WORK.
8. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION
CHARGES REQUIRED.
9. SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT,
MATERIALS AND LAYOUTS PRIOR INSTALLATION.
10. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE, DUCTWORK, ETC.
AS SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS.
11. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A/C CONDENSATE DRAIN
AND TRAP. SEE A/C PLANS FOR LOCATION OF UNITS AND DRAINS.
12. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS
AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT.
13. COORDINATE WORK WITH OTHER TRADES.
14. FURNISH AND INSTALL FIXTURES AS SPECIFIED IN SCHEDULE, THIS DRAWING.
15. EACH BATHROOM GROUP SHALL BE PROVIDE WITH AIR CHAMBERS OR SHOCK
ABSORBER.
16. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE, JUST BEFORE CONNECTING TO FIXTURE.
17. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING
SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES.
18. PIPE INSULATION:
A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT
ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE
DEVELOPED RESPECTIVELY.
B. ALL HOT WATER LINES & 1/2" RECIRCULATING HOT WATER LINES SHALL BE
INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF
25/50 FLAME SPREAD AND SMOKEDEVELOPED RESPECTIVELY.
AC UNIT
PLUMBING LEGEND
SYMBOL
DESCRIPTION
WASTE
1
COLD WATER LINE (CW)
H.W.
REMARKS /SPECS
HOT WATER RECIRC (HWR)
WATER CLOSET
--CD—
CONDENSATE DRAIN LINE
HOT WATER LINE (HW)
-
WALL MOUNTED, FLUSH TANK
SANITARY WASTE LIE (SAN)
TUB
2'`.
SANITARY VENT LI N (V)
3/4"
ANTISCALD, PRESSURE
BALANCING VALVE
WATER HAMMER ARRESTOR
SHOWER
„
CHECK VALVE
—� FCO
FLOOR CLEAN OUT
—�i CO
WALL CLEAN OUT
WHIRLPOOL BA'H
GATE VALVE
3 / 4"
HB
HOSE BIBB
P -2C
VALVE IN BOX
2 ""
VV
GATE VALVE IN VERTICAL
CO--
"P" TRAP
LAVATORY
UNION
--III—
ABV.
ABOVE
�pBLW
BELOW
IL., CLG.
L.
CEILING
FLOOR
F.U.
FIXTURE UNIT
(UG)��
UNDERGROUND
VENT THRU ROOF
VB
VACUUM BREAKER
1/2"
TRAP PRIMER
P -5A
CONNECTION (NEW TO EXISTING)
I
PLUMBING FIXTURE CONNECTION SCHEDULE
MARKS
DESCRIPTION
WASTE
C.W.
H.W.
REMARKS /SPECS
P -1
WATER CLOSET
3" t
1/2"
-
WALL MOUNTED, FLUSH TANK
P -2
TUB
2'`.
3/4"
3/4"
ANTISCALD, PRESSURE
BALANCING VALVE
P -2A
SHOWER
„
s
3/4"
3/4 '•
ANTISCALD, PRESSURE
BALANCING VALVE
P -28
WHIRLPOOL BA'H
3 / 4"
3 4"
/
COORDINATED WITH EQUIPMENT
MANUFACTURER
P -2C
SHOWER
2 ""
2) 3/4"
2) 3/4"
RE
AN ALANCING VALVE
P -3
LAVATORY
110:Z11 /2'
1/2"
1/2"
COUNTER TOP
P -4
BIDET
2" ^
1/2"
1/2"
FLOOR MOUNTED. PROVIDE
VACUUM BREAKER
P -5
KITCHEN SINK
1 -1/2"
1/2"
1/2"
SINGLE COMPARTMENT
P -5A
BUTLER SINK
1 -1/2 "'
/2"
1/2"
SINGLE COMPARTMENT
P -5B
BAR SINK
1114V�?•
1/2"
1/2"
SINGLE COMPARTMENT
P -6
LAUNDRY SINK
1 •kt/21+'
1 /2"
1/2"
SINGLE COMPARTMENT
P -6A
BBQ SINK
1-1/2
1/2"
1/2"
SINGLE COMPARTMENT
WM
WASHER
2"
1/2"
1/2"
PROVIDE RECESSED
SUPPLY DRAIN BOX
DW
DISH WASHER
1 -1/2"
—
1/2"
INDIRECT CONNECTION TO
KITCHEN SINK
REF
REFRIGERATOR
-
1/2"
-
PROVIDE SHUTOFF VALVE
NOTE:
REFER TO ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE SPECIFICATIONS
WATER HEATER SCHEDULE
SYMBOL
SERVICE
GAL.
CAP.
ELECTRICAL
REQUIREMENTS
FUEL / BTUH
REQUIREMENTS
MANUFACTURER /MODEL
EWH -1 & EWH -2
SEE FL PLAN
80
240 V.1PH.60HZ.
2) 6.0 KW EA.
ELECTRIC
LOCHINVAR MODEL ETA082PP
NON— SIMULTANEOUS UPPER & LOWER ELEMENTS
0
I
,�, •� � L� ' JOB I0p1, � r•-•
A M Consulting Engineers LM- I ,� -_:._'
Certificate OF Authorization #9692 ��W -""" 4 •'
t r1
```�..A r Jose M. Martinez P.E. #56018
c�, •�ti { . .� �; 7985 S.Y. 136th STREET TEL, (305) 255 -1621a R�Mff Nom.
• ,cr p l 8 f Miami, Florida 33156 FAX (305) 255 -1732 I _
' �yq N TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED rte` y ♦ 1
jp {� i HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE
s , s' • '• APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF I
;••';. '� Q, 'JAM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE
1 �j C .., REPRODUCED IN WMOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMS5ON a �� P 3■I
• �� OF JMM CONSULTING ENGINNERS, LLC.
i it i
i -
' .,oa
W
00
v
43
4 t 0�
Ir, E
U
■ O
w
F�
Z
# r
",j
I t
I
L REVIKP� w sgP
IM
I I
1
II
I'