Loading...
05-1465-022Electrical Symbols Legend: Not all sy mbols are used O Recessed lighting fixture © Recessed low- voltage lighting fixture -0- Surface mounted lighting fixture FO Wall mounted lighting fixture 0 Recessed wall washer lighting fixture Q Recessed pinhole lighting fixture ® Recessed vapor proof shower fixture 0 / Recessed surface mounted fluorescent lighting fixture >04 Ceiling mounted spot light �--� —+ Under counter low - voltage lighting fixture Q—• Pole mounted lighting fixture Single pole switch 20A $3 Three -way switch 20A $4 Four -way switch 20A Dimmer switch sized as required -� Single receptacle outlet 20A Duplex receptacle outlet 15A. Small appliances do bathrooms to be 20A) Duplex receptacle outlet above counter top (20A) Quadruplet receptacle outlet 15A Duplex receptacle outlet -sprit wire 15A Fel Floor duplex receptacle outlet F► Floor telephone outlet ► Telephone outlet �5 Speaker outlet T.V. Cable outlet OS Satellite cable outlet -{B 240V connection Q Junction box ❑-€ Disconnect switch sized as required per equipment manufacturer nameplate Ceiling fan Exhaust fan SD Smoke detector (110 v. battery back -up interconnected) GFl Indicates ground -fault interrupter WP Indicates weatherproof device or plate AFF Indicates above finished floor or grade NOTES: (NOT ALL NOTES ARE APPLICABLE) 1. PROVIDE ALL FINAL CONNECTIONS TO ALL EQUIPMENT AND APPLIANCES. 2. PROVIDE ALL A/C CONTROL IN SEPARATE 1/2 "C AS REQUIRED BY A/C DRAWINGS OR MANUFACTURER DIAGRAMS. 3. ALL LAVATORIES AND KITCHEN RECEPTACLES SHALL BE GFl TYPE. 4. TERRACE RECEPTACLES TO BE GFl AND WEATHER PROOF. 5. COORDINATE LOCATION OF ALL DISCONNECT SWITCHES WITH OTHER TRADES TO ALLOW N.E.C. REQUIREMENT CLEARANCE. 6. CIRCUITS WIRING REQUIRED TO BE AS FOLLOWS: 120V -2 WIRE (L -n); 120/240V - 3 WIRE (LL -N); 240V -2 WIRE (LL). wHEN EQUIPMENT GROUND IS REQUIRED INCREASE CONDUIT SIZE AS REQUIRED. 7. ALL WIRING TO BE COPPER. THHN/THWN TYPE RUN IN METALIC CONDUIT. 8. ALL COUNTER RECEPTACLES AND SWITCHES TO BE MOUNTED +48" MAXIMUM FINISHED FLOOR (TO BOTTOM OF PLATE). UNLESS OTHERWISE NOTED COORDINATE HEIGHT WITH ARCHITECT. 9. REFRIGERATOR RECEPTACLE TO BE MOUNTED + 48" A.F.F. 10. ALL LAVATORY RECEPTACLES TO BE MOUNTED + 48" A.F.F. MAXIMUM, COORDINATE HEIGHT WITH ARCHITECT. 11. COORDINATE LOCATION OF AIR CONDITIONER (INDOOR UNIT) DISCONNECT SWITCH WITH A/C CONTRACTOR TO KEEP N.E.C. REQUIRED CLEARANCE. 12. ALL DUPLEX RECEPTACLES IN EXTERIOR AREAS TO BE OF GFI TYPE AND WEATHER PROOF. 13. MINIMUM WIRE SIZE SHALL BE #12 THHN /THWN WITH THE EXCEPTION OF 15A GENERAL LTG. AND RECEPTACLE BRANCH CIRCUITS WHICH ARE #14 THHN /THWN 14. CONDUCTORS #6 AWG AND LARGER SHALL BE THW. 15. ALL CONDUCTORS SHALL BE COPPER. 16. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. 17. CONDUIT IN UNFINISHED AREAS SHALL BE EXPOSED. 18. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE. 19. INSTALL NYLON PULL STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. 20. ALL MATERIALS SHALL BE U.L. APPROVED. 21. WORKMANSHIP SHALL BE TO BEST COMMERCIAL PRACTICE. 22. INSTALLATION SHALL BE IN ACCORDANCE WITH LOCAL, STATE AND NATIONAL CODES. 23. RECESSED LIGHT FIXTURES OVER BATHTUB OR SHOWER SHALL BE COMPLETELY ENCLOSED AND VAPOR PROOF SUITABLE FOR WET LOCATIONS. 24. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMENDATIONS AND LOCAL CODE REQUIREMENTS. 25. RISERS ARE DIAGRAMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 26. THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 27. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED. ON CONTRACT DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 28. CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUITS WIRING AND RACEWAYS AS SHWON ON THE AIR CONDITIONING DRAWINGS OR SPECIFICATIONS. IF AIR CONDITIONING DRAWINGS REFER TO MANUFACTURER'S WIRING DIAGRAMS, THE CONTRACTOR SHALL VERIFY WITH SAID MANUFACTURER ALL REQUIREMENTS AND INCLUDE ALL RELATED WORK IN HIS CONTRACT. 29. ALL DEVICES, PANELS, OUTLETS, SWITCHES, ETC. TO BE MOUNTED ABOVE FLOOD CRITERIA. �I sa I Nggd. e14 C,., { f � € i SODDED/LANDSC I < R � t ; �__/ ELECTRICAL SITE PLAN SCALE: 1/8" - T— O' t.� r Ills l� t f` 1 y { 2y `lvt,'y1 f'•iti•If: ?14 %1.�•, jJi�l�� !��C1 'r rl _i:iV0Rq11r- _ 00iGAIUt3 Ji+f14 i i 0LiR i 2 Ll k� co O� � U � W C�7 � JMM Consulting Engineers LLC Certificate OF Authorization #9692 Jose M. Martinez, P.E. #56018 7985 S.A. 136th STREET TEL. (305) 255 -1621 Miami, Florida 33156 FAX (305) 255 -1732 TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF 'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF JMM CONSULTING ENGINNERS, I.I.C. F11AM PBW su REVIN" Z t s ''www VJ tf 1�1 x JMM Consulting Engineers LLC Certificate OF Authorization #9692 Jose M. Martinez, P.E. #56018 7985 S.A. 136th STREET TEL. (305) 255 -1621 Miami, Florida 33156 FAX (305) 255 -1732 TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF 'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF JMM CONSULTING ENGINNERS, I.I.C. F11AM PBW su REVIN"