05-1465-016FTG. FTG. CMU BLOCKS - SEE PLAN CMU BLOCKS - SEE PLAN 1/2" JOINT FILLER & SEALANT REINF. IN FILLED 1/2- JOINT FILLER & SEALANT 1 CELL AS REQ'D. / W.W.F. SEE PLAN SEE PLAN ni, W.W.F. SEE PLAN SLAB THICK. SEE PLAN SLABP THICK. FIN. GR. EL. II FIN. FL. EL. .. SEE PLAN I, 0' -0" ii' .I x FIN. FL. EL. r - - - -- - - - - -- b X X .ii X II m REINF. IN FILLED I II I \ o J I 1I VAPOR BARRIER I CELL AS REQ'D. \ / T I SEE PLAN EL. -1' -6" IIII `I II ' I I I VA POR BARRIER EL. -1' -6" = %__ • . " 1 . . (W N w • FILL N I 6" COMPACTED GRANULAR 3" CL.I I '. A LL FOR REINF. SEE SCHED. SEE FTG. FOR REINF. SEE FTG. SCHED. SEE SCHED. SCHED. TYPICAL CONTINUOUS WALL FTG. NTS ( EXTERIOR ) ® J Z g _j O 1/4" SAW -CUT JOINT CL z N U N W VAPOR BARRIER W.W.F. SEE PLAN C.J. -1 (TYP. SAW -CUT SLAB JOINT) 4 OPTIONAL SLAB CONST. JOINT DETAIL S1 S4 (CONST. JOINT WHERE REQUIRED - MARKED C.J. ON PLAN CONC. COL TYPICAL CONTINOUS WALL FTG. ( INTERIOR ) (n U) LLJ g Q_ Q_ w w 0 W wZ 1, J CLW UZ U T ww =g m w gw (f) V) I♦ - \ 6" COMPACTED VAPOR BARRIER FILL 5 TYPICAL SLAB DEPRESSION S1 S4 4 -5/8' NELSON STUDS CONC. SLAB SEE PLAN. ..... '. . . ..... . ..... . ... _ . . ... .. . . L .. . . ... .'''' ''' ' ', ' i . ....._ ...... - - < o MARK W.W.F. SEE PLAN P 12"X1 2"X Y2 ". -� dFC 4 "X4 "X YZ ". REINFORCING 3 $ CONC. m TOP REINF. (EW) F -1 5'- 0 "x5' -0" 16" E 70 SLAB f'c= 4000 PSI F -2 4'- 0 "x4' -0" 14 6 #5 f'c= 4000 PSI . co 3'- 0 "x3' -0" 14„ 4 #5 -118.6 f'c= 4000 PSI -66.6 -82.2 20 +33.2 +33.2 f'c= 4000 PSI WF -18 18" 14" SEE S -5 FOR DETAILS. .... .... ......... ................ WF -24 CONC. SLAB 16" 3 #5 L.W, #4 024 "S.W. DOWEL TO MATCH f'c= 4000 PSI WF -48 ON GRADE 18" 5 #5 L.W, #4 @12-S.W. COL. REINF. ... ... 6" COMPACTED -71.1 60 +27.3 +27.3 • • • GRANULAR SOIL +54.2 -52.1 -90.3 -90.3 -59.4 -67.9 80 +26.0 +26.0 ................... +53.1 +53.1 . -51.5 -85.7 I +58.3 a. 100 CONC. OVER POUR +25.0 +25.0 +52.2 +52.2 AROUND BASE PLATE -82.2 -82.2 1 -51.4 1 -63.8 & COL. CONC. FTG. SEE , , , ENCAREMENT. SCHEDULE. .4. ' ' '• •. . CONC. FOOTING III IIII'' SEE FOOTING SHEKEL TYPICAL COLUMN FOOTING DETAILS NTS z Z CL a W Z z w w g O Ld a v J w u w w � J OIL � w z �}Z l� �1U 1/2" JOINT - FILLER & SEALER Y Z U U Z Cr =g � m Uj w w w I- cn In c w J:� O U IL: 2 � z _ io �Z 2 T 6" COMPACTED FILL VAPOR BARRIER AS REO'D. /"3 TYPICAL THICKENED EDGE S1 S4 (TYP. AT DISCONTINUOUS EDGE OF SLAB) FOOTING SCHEDULE MARK SIZE DEPTH REINFORCING REMARKS BOT. REINF. (EW) TOP REINF. (EW) F -1 5'- 0 "x5' -0" 16" 7 #5 +35.4 f'c= 4000 PSI F -2 4'- 0 "x4' -0" 14 6 #5 f'c= 4000 PSI F -3 3'- 0 "x3' -0" 14„ 4 #5 -118.6 f'c= 4000 PSI -66.6 -82.2 20 +33.2 +33.2 f'c= 4000 PSI WF -18 18" 14" 2 #5 L.W, #4 @24-S.W. -107.6 f'c= 4000 PSI WF -24 24" 16" 3 #5 L.W, #4 024 "S.W. +29.1 f'c= 4000 PSI WF -48 48" 18" 5 #5 L.W, #4 @12-S.W. j 5 #5 L.W, #4 @24 "S.W. f'c= 4000 PSI ASCE7 -98 WIND LOADS ON COMPONENTS & CLADDING WIND VELOCITY 146 MPH, EXP. "C ", 1 =1.0, GCPi =+ 0.18 Fy2 ZONE 1 2 3 4 5 AREA M +35.4 +35.4 +35.4 +61.4 +61.4 10 -56.2 -118.6 -118.6 -66.6 -82.2 20 +33.2 +33.2 +33.2 +58.6 +58.6 -54.6 -107.6 -107.6 -63.8 -76.6 +29.1 +29.1 +29.1 +55.8 +55.8 40 -53.0 -96.7 -96.7 -61.0 -71.1 60 +27.3 +27.3 +27.3 +54.2 +54.2 -52.1 -90.3 -90.3 -59.4 -67.9 80 +26.0 +26.0 +26.0 +53.1 +53.1 -51.5 -85.7 1 -85.7 +58.3 -65.6 100 +25.0 +25.0 +25.0 +52.2 +52.2 -51.0 -82.2 -82.2 1 -51.4 1 -63.8 co O ZONE O 101 I STEEL COLUMN TO CONCRETE FOOTING CONNECTION DETAIL WIND LOADS DIAGRAM ZONE ZONE ZONE O O O STRUCTURAL NOTES 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, LATEST EDITION & REVISIONS. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE ALL OPENINGS, CHASES, SLEEVES, ITEMS TO BE EMBEDDED IN CONCRETE WITH ARCHITECTURAL MECHANICAL AND ELECTRICAL DRAWINGS. REPORT ANY DISCREPANCIES OR CONFLICTS WITH THE ENGINEER. 3. SPLICES IN REBARS SHALL BE A MINIMUM OF 48 BAR DIAMETER EXCEPT WHERE DIMENSIONED OTHERWISE. 4. EXCEPT WHERE OTHERWISE DIMENSIONED, ALL HOOKS ON REBARS SHALL BE STANDARD ACI 318 -89 HOOKS. 5. REBARS: NEW ASTM A -615 GRADE 60. FABRICATE AND DETAIL IN ACCORDANCE WITH ACI -315. HORIZONTAL JOINT REINF: "DUR -O- WALL" LADUR TYPE 9 -5, LOX -ALL #9 STD. OR APPROVED EQUAL WITH "T" & "L" FOR INTER- SECTIONS AND CORNERS. 6. CONCRETE COVER OVER THE REBARS SHALL BE AS DETAILED IN THE DRAWINGS. WHERE COVER IS NOT DIMENSIONED, USE THE SAME COVER AS DIMENSIONED FOR SIMILAR ITEMS. WHERE THERE ARE NO SIMILAR ITEMS, USE THE FOLLOWING: 3" FOR BOTTOM AND ENDS OF FOOTING; 1 1/2" FOR TIES OR STIRRUPS ON COLUMNS AND BEAMS (2" OVER MAIN REINFORCING); 2" FOR FORMED CONCRETE IN CONTACT WITH THE GROUND; SLABS = 3/4" FOR INTERIOR EXPOSURE AND 1 1/2" FOR EXPOSURE TO EARTH OR WEATHER. 7. WELDED WIRE FABRIC TO CONFORM TO ASTM A -185 SUPPORTED AT A MINIMUM OF 36" 0/C EACH WAY: LAP FABRIC A MINIMUM OF 6" AT THE SIDES. 8. FILL AND BACK -FILL SHALL BE PLACED IN LAYERS NOT GREATER THAN 12" LOOSE THICKNESS MEASURE & COMPACTED TO NOT LESS THAN 95% OF AASHTO T -180. 9. FOR SLAB ON FILL, MOISTEN AND RECOMPACT SUBGRADE AFTER UNDERGROUND UTILITIES HAVE BEEN BACKFILLED AND JUST BEFORE PLACING POLYETHYLENE SHEETING. PROVIDE 0.006" THICK SHEETING UNDER ALL INTERIOR SLABS ON FILL. TAPE ALL JOINTS. 10. SEPARATE SLAB ON FILL FROM WALL, COLUMNS AND OTHER ITEMS PENETRATING SLAB, WITH 1j2" PRE - MOULDED JOINT FILLER MATERIAL FOR FULL THICKNESS OF SLAB CONCRETE, ASTM D -1752 TYPE 1, EXCEPT AS OTHERWISE NOTED ON THE DRAWINGS. 11. BLOCKS IN WALLS AND FOUNDATIONS SHALL BE ACCORDING TO ASTM C90, TYPE 1, GRADE N -1 WITH MINIMUM FACE SHELL THICKNESS OF 1 -1/4 ". MINIMUM COMPRESSIVE STRENGTH SHALL BE 2,500 P.S.I., EXCEPT NON -LOAD BEARING MAY BE 1,500 P.S.I. 12. ALL MASONRY WALLS SHOWN ON STRUCTURAL DRAWINGS SHALL BE IN PLACE PRIOR TO FORMING OR PLACING CONCRETE IN COLUMNS AND BEAMS OVER THE WALLS, EXCEPT AS OTHERWISE SPECIFIED. PROVIDE VERTICAL REINFORCING IN BLOCK CELLS AND FILL CELLS WITH CONCRETE AS INDICATED ON THE DRAWINGS. PROVIDE 9GA. LADDER TYPE HORIZONTAL JOINT REINFORCING IN EVERY OTHER COURSE. HORIZONTAL JOINT REINFORCING SHALL EXTEND A MINIMUM OF 6" INTO ALL ABUTTING COLUMNS. GROUTING SHALL BE A CONTINUOUS OPERATION IN LIFTS NOT EXCEEDING 4' -0" AND A MAXIMUM POUR OF 12' -0. SPECIAL INSPECTION IS REQUIRED FOR ALL REINF MASONRY AND GROUTING. 13. ALL MASONRY WALLS SHOWN ON STRUCTURAL DRAWINGS SHALL BE IN PLACE PRIOR TO ERECTING WOOD TRUSSES 14. SUPERIMPOSED LOADS: 1. DEAD LOADS: ROOF .................. = 25 P.S.F. 2. LIVE LOAD: ROOF .................. = 30 P.S.F. SECOND FLR..... = 40 P.S.F. STAIR .................. = 60 P.S.F. 15. COMPRESSIVE STRENGTH OF CONCRETE ® 28 DAYS = 4000 P.S.I. U.O.N ON PLAN. 16. CONCRETE SLUMP: 3" t 1 " FOR FOOTINGS AND SLABS ON FILL. 4" t 1 " FOR 'ALL BEAMS, AND 9 f 1 FOR GROUTS IN MASONRY WALLS. MAKE SLUMP TESTS WHEN CYLINCERS ARE MADE AND AT OTHER TIMES AS NECESSARY TO VERIFY SLUMP. 17. STRUCTURAL :TEEL: L At 0 U Cn w ]:E O z U w Z F � U x � �Q A. CON=ORMING TO ASTM A -36. PIPE COL. TO ASTM A501. B. ALL ANCHOR BOLTS SHALL BE ASTM A -307, HOT -DIP GALVANIZED. C. PROVIDE ONE SHOP COAT OF RUST INHIBITING PAINT (MINIMUM 3 MIL. DRY FILM THICKNESS.) D. FABRICATION AND ERECTION ACCORDING TO AISC SPECS. 18. WELDING: A. ALL WELDING IS TO BE PERFORMED BY CURRENT CERTIFIED WELDERS. B. ELECTRODES TO BE E -70 SERIES, LOW HYDROGEN (STORED ACCORDING TO A.W.S. REQUIREMENTS). 19. FRAMING LUMBER: A. NOMINAL SIZE INDICATED. DRESSED S4S B. SPECIES: DOUGLAS FIR [z] C. MOISTURE CONTENT. 19% MAXIMUM D. MINMUM EXTREME FIBER BENDING STRESS (FB) = 1,450 P.S.I. 20. FRAMING BLOCKING AND NAILERS EXPOSED TO MOISTURE OR DIRECTLY ATACHED TO MASONRY OR CONCRETE SHALL BE UTILITY GRADE OR BETTER YELLOW PINE, PRESSURE TREATED. 21. PLYWOOD ROOF DECKS: A. 5/8" C -D INT -APA STRUCTURAL 1 WITH EXTERIOR GLUE C-- M B. EDGE SUPPORT: PLY CLIPS - C. NAILING 8d COMMON SPIRAL OF EDGES 6" O.C. AND AND 10d NAILS 0 4" 0/C FOR GABLE ENDS. 22. ROUGH SAWN FRAMING TIMBER: A. FULL SIZE INDICATED B. SPECIES: 1. DOUGLAS FIR OR SOUTHERN PINE. FB =1300 PSI MINIMUM OR FB =1900 PSI MIN. ( AS INDICATED ON PLAN). C. MOISTURE CONTENT 19% MAX. D. FREE OF DRY ROT AND OTHER VOIDS E. SMALL TRIM MEMBERS WILL BE FREE OF KNOTS 23. ALL FASTENEFS AND HARDWARE EXPOSED TO WEATHER TO BE HOT DIPPED M,� ,,__. -__.._ -- - - -• - -; GALVANIZED. _....__.... .. _�.....__.....- ..___.. -_ . 24. ALL WOOD TRJSSES SHALL BE DESIGNED & FABRICATED ACCORDING ; TO THE SOUTI FLORIDA BLDG. CODE. SUBMIT ALL CALCULATIONS AND DRAWINGS SIGNED & SEALED BY A FLORIDA REGISTERED STRUCTURAL 1 t ENGINEER F01 REVIEW & COUNTY APPROVAL. f '�1'•- x� t g 25. ALL INTERIOR STAIR, HANDRAILS, ETC SHALL BE DESIGNED & FABRICATED � ; •-` - ` "'- '- " -�- - -•�. �� . y ACCORDING TO THE FLORIDA BLDG. CODE. SUBMIT ALL CALCULATIONS Imo+ AND DRAWING. SIGNED & SEALED BY A FLORIDA REGISTERED STRUCTURAO, ENGINEER FOF REVIEW & COUNTY APPROVAL. DM 7fAM •, \. 1111 It,,,,,,/ Na ° ,' 1 2 o 13101 l • . M. Hajjar & Associates Inc. MOHAMMAD HAJJAR,P.E. EB 8373 - PE 40187 2750 Douglas Road Suite 200, Miami, Florida 33133 Tel. (305)445 -2399 Fax. (305)445 -2219 nRAwx sY RM AM SY SEEM Na BL ERUA% M S -4