05-1465-002CONSULTANTS.
GENERAL
NOTES.
AMC
INDEX OF DRAWINGS.
Fm
AAA
COVER
SHEET
I. SUMMARY OF WORK, INTENT OF
10. WOOD, ALL WOOD IN CONTACT WITH
{
DRAWINGS IS THAT THE CONTRACTOR'S
MASONRY OR CONCRETE SHALL BE
STRUCTURAL
WORK WILL CONSIST OF FURNISHING
PRESSURE TREATED, LUMBER SHALL BE
-
ALL LABOR, MATERIAL, AND EQUIPMENT
SOUTHERN PINE OR DOUGLAS FIR,
NECESSARY AND REQUIRED TO
GRADE u2 U.O.N.
ARCHITECTURAL
COMPLETE NEW WORK AS INDICATED ON
M. HAJJAR & ASSOCIATES
PLANS AND SPECIFICATIONS.
II. ALL COLOR PATTERNS OF FINISHES
CONTRACTOR WILL BE RESPONSIBLE FOR
AND OTHER MATERIAL OF DESIGN SHALL
2750 DOUGLAS ROAD, SUITE 200
EXCAVATION OF FOOTINGS, ALL
BE APPROVED OR SELECTED BY THE
A -1.0
INDEX OF DRAWINGS AND
FORMING WORK, PLACEMENT OF
OWNER AND ARCHITECT.
MIAMI, FLORIDA 33133
REINFORCING STEEL, POURING AND
GENERAL NOTES
TEL: (305) 445- 2399
FINISHING OF ALL CONCRETE, LAYING
BLOCKS AND CAP CONSTRUCTION.
12. GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL SUBCONTRACTORS
L -1
LANDSCAPE PLAN AND LEGEND
CONTRACTOR WILL BE REQUIRED TO
OBSERVE AND COMPLY WITH ALL
WORKING AT JOB SITE AND FOR ALL
COORDINATION OF WORK AMONG
A-2.0
SITE PLAN & PROJECT DATA
- M
FEDERAL, STATE, AND LOCAL
ORDINANCES THAT AFFECT THOSE
THEM. THE MECHANICAL AND
ELECTRICAL CONTRACTOR SHALL FULLY
A-3-0
GROUND FLOOR PLAN & NOTES
■E ■P■
ENGAGED OR EMPLOYED ON THE
PROJECT, THE MATERIALS OR EQUIPMENT
COORDINATE ALL EQUIPMENT WITH THE
OTHER TRADES, THESE CONTRACTORS
A- 3.1
SECOND FLOOR PLAN & NOTES
JMM CONSULTING ENGINEERS, LLC
USED, AND THE CONDUCT OF THE WORK.
SHALL BE RESPONSIBLE FOR THE FINAL
A-3.2
ROOF PLAN & NOTES
12651 S. DIXIE HIGHWAY, SUITE 326
2. DRAWINGS, DRAWINGS ARE SCHEMATIC
SHOWING RELATIVE LOCATIONS AND
HOOKUP OF ALL EQUIPMENT NOT
FURNISHED BY THEM BUT REQUIRING
A -4.0
FRONT & REAR ELEVATIONS & NOTES
CONNECTIONS AND SHALL NOT BE
THE SAME FOR FINAL COMPLETION.
PINECREST, FLORIDA 33133
SCALED FOR EXACT LOCATIONS. THE
A-4.1
EAST & WEST SIDE ELEVATIONS & NOTES
TEL: (305) 255-1621
ARCHITECTURAL AND SITE CONDITIONS
SHALL GOVERN. SHOULD ANY
13. ALL OF THE CONTRACTOR'S
EQUIPMENT SCAFFOLDING HOISTS, ETC.,
A-5.0
BUILDING SECTIONS & NOTES
DIFFICULTY OCCUR IN THE RUNNING OF
PIPING LT DUCTS, SETTING U DEVICES
SHALL BE AVAILABLE TO THE
OWNER /ARCHITECT AND HIS STAFF FOR
A-6.0
WALL SECTIONS & DETAILS
OR CONNECTIONS AT ANY POINT SHOWN,
INSPECTION OF ANY AND ALL WORK
DURING NORMAL WORKING HOURS.
A- 7.0
DOOR, WINDOW & ROOM FINISH SCHEDULE
CONTACT ARCHITECT /ENGINEER PRIOR
TO PROCEEDING WITH THE WORK.
14. THE CONTRACTOR IS RESPONSIBLE
3. SURVEY, BEFORE BIDING,
FOR ALL DELIVERY POINTS, HOISTS
CONTRACTOR SHALL MAKE A THOROUGH
LOCATIONS, ACCESS TO AND FROM THE
SURVEY OF THE SITE AND TAKE INTO
CONSTRUCTION SITE AND UTILITY
STRUCTURAL
CONSIDERATION ALL CONDITIONS THAT
SERVICES WITH CONTRACTING OFFICER
MAY AFFECT THEIR PERFORMANCE.
OR HIS AUTHORIZED REPRESENTATIVE.
4. CONTRACTOR WILL CONSTRUCT WALLS
15. THE CONTRACTOR SHALL HAVE THE
8-1
FOUNDATION PLAN
ACCORDING TO CONTRACT DRAWINGS
CONSTRUCTION SITE SECURED AT ALL
8-2
SECOND FLOOR FRAMING PLAN
AND SPECIFICATIONS AND WILL MIX AND
TIMES UNTIL FINAL ACCEPTANCE OF
USE MATERIALS FOR CONSTRUCTION IN
WORK BY OWNER.
8-3
ROOF FLOOR FRAMING PLAN
COMPLIANCE WITH MANUFACTURER'S
SPECIFICATIONS. ANY DEVIATION FROM
16. ANY SUBCONTRACTOR CUTTING INTO
S- 4
DETAILS AND FOOTING SECTIONS
CONTRACT DRAWINGS OR
WORK ALREADY COMPLETED, CUTTING
S-5
COLUMN & BEAM DETAILS
MANUFACTURER'S SPECIFICATIONS WILL
CHASES AND OR TRENCHES FOR THE
REQUIRE APPROVAL BY THE ARCHITECT.
INTRODUCTION OF HIS WORK AND
8-6
SECTIONS
EQUIPMENT, SHALL DO OR PAY FOR ALL
5. CONTRACTOR SHALL VERIFY AND BE
BACK FILLING, REPARATION OF WALLS,
RESPONSBLE FOR ALL DIMENSIONS AND
FLOORS, ETC., DAMAGED BY SUCH
JOB SITE CONDITIONS RELATED TO THIS
COMPANY. ALL REPAIRS SHALL MATCH
MECHANICAL
WORK. AVY DISCREPANCIES IN
EXISTING SURFACES.
DIMENSICNS OR SPECIAL MODIFICATION
M -1.0
GROUND FLOOR MECHANICAL PLAN
REQUIRED DUE TO FIELD CONDITIONS
SHALL BE REPORTED IN WRITING TO
17. PROVIDE GALVANIC INSULATION
M -1.1
SECOND FLOOR MECHANICAL PLAN
THE ARCHITECT FOR CLARIFICATION OR
BETWEEN ALL DISSIMILAR METALS.
M- 2.0
MECHANICAL NOTES & DETAILS
APPROVAL OF MODIFICATION BEFORE
COMMENCING WORK. THE
18. ALL HARDWARE SHALL MAINTAIN THE
RESPONSIBILITY FOR ANY CHANGES
INTEGRITY OF THE FIRE RATING OF
MADE ON THE FIELD WITHOUT PRIOR
DOORS.
ELECTRICAL
NOTIFICATION TO THE ARCHITECT,
SHALL REST WITH THE CONTRACTOR OR
19. CONTRACTOR SHALL VERIFY SIZE OF
ANY OTI-ER PERSON APPROVING SUCH A
ALL DOOR OPENINGS AND EXACT DOOR
E -1.0
ELECTRICAL SITE PLAN
CHANGE.
SWING AS PER ARCHITECTURAL FLOOR
PLANS, CONTACT THE ARCHITECT IF ANY
E-2.0
GROUND FLOOR ELECTRICAL PLAN
6. ALL DIMENSIONS SHALL BE
DISCREPANCIES ARE FOUND BEFORE
CONSIDEQED 'NOMINAL' UNLESS NOTED
ORDERING DOORS AND /OR FRAMES.
E- 2.1
SECOND FLOOR ELECTRICAL PLAN
OTHERWISE. WRITTEN DIMENSIONS
E-3.0
ELECTRICAL NOTES & SCHEDULES
SHALL GOVERN. DO NOT SCALE FROM
20. CAULKING AND SEALANTS,
DRAWINGS. DIMENSIONS ON LARGE
INSTALLATION SHALL BE GUARANTEED
SCALE D2AWINGS OR DETAILS WILL
WEATHER TIGHT. EXTERIOR METAL
PREVAIL OVER SMALLER SCALED
WORK, INCLUDING WINDOWS,
PLUMBING
DRAWINGS. ALL ANGLES ARE TAKEN AT
STOREFRONTS, DOOR FRAMES AND ALL
90 DEGREE UNLESS OTHERWISE NOTED.
JUNCTIONS BETWEEN MASONRY,
CONCRETE AND METAL SHALL BE
P -1.0
PLUMBING SITE PLAN
7. CONTRACTOR WILL BE RESPONSIBLE
SEALED WITH NEOPRENE OR
FOR OBTAINING ALL NECESSARY PERMITS
POLYURETHANE FILLER AND APPROVED
P-2.0
GROUND FLOOR PLUMBING PLAN
AND INSFECTIONS REQUIRED FOR THE
PROJECT,
SEALANT COMPOUNDS.
P-2.1
SECOND FLOOR PLUMBING PLAN
21. TERMITE TREATMENT, TREAT ALL
P-3.0
PLUMBING ISOMETRICS
8. ALL WORK SHALL BE IN COMPLIANCE
WITH THE SOUTH FLORIDA BUILDING
SOIL UNDER SLAB AND WITHIN A
DISTANCE OF 4'- 0' BEYOND ALL
P- 3.1
PLUMBING NOTES & DETAILS
CODE, LATEST EDITION, ACI 318.33 AND
FOOTINGS AND SLAB EDGES AS PER
ALL APPLICABLE STATE, LOCAL
REQUIREMENTS OF THE FLORIDA STATE
REGULATONS AND ORDINANCES HAVING
BOARD OF HEALTH, MEMORANDUM 173,
JU12ISDIC "ION OVER THE PROJECT.
JULY 31,1978.
22. ALL PIPING AND CONDUIT UNDER
9. ALL MANUFACTURERS, SUPPLIERS, AND
SLAB SHALL BE A MINIMUM OF 2'-0"
FABRICA -ORS SHALL SUBMIT SHOP
CLEAR OR UNDERSIDE FOOTING.
DRAWINGS TO THE ARCHITECT FOR
APPROVAL PRIOR TO FABRICATION.
G�
Uz
tr�
W
m �
O�
2
� U 8
w
F �
U #
F'� H
ONO
V � z
f may'
T-101
g8 "R
z A
DATE
7f1W
JOB NQ
20"
DRAWN BY
Ef
AM BY
SHWr NQ
AMC
A -1.0
Fm
AAA
{