05-1465-002CONSULTANTS. GENERAL NOTES. AMC INDEX OF DRAWINGS. Fm AAA COVER SHEET I. SUMMARY OF WORK, INTENT OF 10. WOOD, ALL WOOD IN CONTACT WITH { DRAWINGS IS THAT THE CONTRACTOR'S MASONRY OR CONCRETE SHALL BE STRUCTURAL WORK WILL CONSIST OF FURNISHING PRESSURE TREATED, LUMBER SHALL BE - ALL LABOR, MATERIAL, AND EQUIPMENT SOUTHERN PINE OR DOUGLAS FIR, NECESSARY AND REQUIRED TO GRADE u2 U.O.N. ARCHITECTURAL COMPLETE NEW WORK AS INDICATED ON M. HAJJAR & ASSOCIATES PLANS AND SPECIFICATIONS. II. ALL COLOR PATTERNS OF FINISHES CONTRACTOR WILL BE RESPONSIBLE FOR AND OTHER MATERIAL OF DESIGN SHALL 2750 DOUGLAS ROAD, SUITE 200 EXCAVATION OF FOOTINGS, ALL BE APPROVED OR SELECTED BY THE A -1.0 INDEX OF DRAWINGS AND FORMING WORK, PLACEMENT OF OWNER AND ARCHITECT. MIAMI, FLORIDA 33133 REINFORCING STEEL, POURING AND GENERAL NOTES TEL: (305) 445- 2399 FINISHING OF ALL CONCRETE, LAYING BLOCKS AND CAP CONSTRUCTION. 12. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SUBCONTRACTORS L -1 LANDSCAPE PLAN AND LEGEND CONTRACTOR WILL BE REQUIRED TO OBSERVE AND COMPLY WITH ALL WORKING AT JOB SITE AND FOR ALL COORDINATION OF WORK AMONG A-2.0 SITE PLAN & PROJECT DATA - M FEDERAL, STATE, AND LOCAL ORDINANCES THAT AFFECT THOSE THEM. THE MECHANICAL AND ELECTRICAL CONTRACTOR SHALL FULLY A-3-0 GROUND FLOOR PLAN & NOTES ■E ■P■ ENGAGED OR EMPLOYED ON THE PROJECT, THE MATERIALS OR EQUIPMENT COORDINATE ALL EQUIPMENT WITH THE OTHER TRADES, THESE CONTRACTORS A- 3.1 SECOND FLOOR PLAN & NOTES JMM CONSULTING ENGINEERS, LLC USED, AND THE CONDUCT OF THE WORK. SHALL BE RESPONSIBLE FOR THE FINAL A-3.2 ROOF PLAN & NOTES 12651 S. DIXIE HIGHWAY, SUITE 326 2. DRAWINGS, DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND HOOKUP OF ALL EQUIPMENT NOT FURNISHED BY THEM BUT REQUIRING A -4.0 FRONT & REAR ELEVATIONS & NOTES CONNECTIONS AND SHALL NOT BE THE SAME FOR FINAL COMPLETION. PINECREST, FLORIDA 33133 SCALED FOR EXACT LOCATIONS. THE A-4.1 EAST & WEST SIDE ELEVATIONS & NOTES TEL: (305) 255-1621 ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN. SHOULD ANY 13. ALL OF THE CONTRACTOR'S EQUIPMENT SCAFFOLDING HOISTS, ETC., A-5.0 BUILDING SECTIONS & NOTES DIFFICULTY OCCUR IN THE RUNNING OF PIPING LT DUCTS, SETTING U DEVICES SHALL BE AVAILABLE TO THE OWNER /ARCHITECT AND HIS STAFF FOR A-6.0 WALL SECTIONS & DETAILS OR CONNECTIONS AT ANY POINT SHOWN, INSPECTION OF ANY AND ALL WORK DURING NORMAL WORKING HOURS. A- 7.0 DOOR, WINDOW & ROOM FINISH SCHEDULE CONTACT ARCHITECT /ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 14. THE CONTRACTOR IS RESPONSIBLE 3. SURVEY, BEFORE BIDING, FOR ALL DELIVERY POINTS, HOISTS CONTRACTOR SHALL MAKE A THOROUGH LOCATIONS, ACCESS TO AND FROM THE SURVEY OF THE SITE AND TAKE INTO CONSTRUCTION SITE AND UTILITY STRUCTURAL CONSIDERATION ALL CONDITIONS THAT SERVICES WITH CONTRACTING OFFICER MAY AFFECT THEIR PERFORMANCE. OR HIS AUTHORIZED REPRESENTATIVE. 4. CONTRACTOR WILL CONSTRUCT WALLS 15. THE CONTRACTOR SHALL HAVE THE 8-1 FOUNDATION PLAN ACCORDING TO CONTRACT DRAWINGS CONSTRUCTION SITE SECURED AT ALL 8-2 SECOND FLOOR FRAMING PLAN AND SPECIFICATIONS AND WILL MIX AND TIMES UNTIL FINAL ACCEPTANCE OF USE MATERIALS FOR CONSTRUCTION IN WORK BY OWNER. 8-3 ROOF FLOOR FRAMING PLAN COMPLIANCE WITH MANUFACTURER'S SPECIFICATIONS. ANY DEVIATION FROM 16. ANY SUBCONTRACTOR CUTTING INTO S- 4 DETAILS AND FOOTING SECTIONS CONTRACT DRAWINGS OR WORK ALREADY COMPLETED, CUTTING S-5 COLUMN & BEAM DETAILS MANUFACTURER'S SPECIFICATIONS WILL CHASES AND OR TRENCHES FOR THE REQUIRE APPROVAL BY THE ARCHITECT. INTRODUCTION OF HIS WORK AND 8-6 SECTIONS EQUIPMENT, SHALL DO OR PAY FOR ALL 5. CONTRACTOR SHALL VERIFY AND BE BACK FILLING, REPARATION OF WALLS, RESPONSBLE FOR ALL DIMENSIONS AND FLOORS, ETC., DAMAGED BY SUCH JOB SITE CONDITIONS RELATED TO THIS COMPANY. ALL REPAIRS SHALL MATCH MECHANICAL WORK. AVY DISCREPANCIES IN EXISTING SURFACES. DIMENSICNS OR SPECIAL MODIFICATION M -1.0 GROUND FLOOR MECHANICAL PLAN REQUIRED DUE TO FIELD CONDITIONS SHALL BE REPORTED IN WRITING TO 17. PROVIDE GALVANIC INSULATION M -1.1 SECOND FLOOR MECHANICAL PLAN THE ARCHITECT FOR CLARIFICATION OR BETWEEN ALL DISSIMILAR METALS. M- 2.0 MECHANICAL NOTES & DETAILS APPROVAL OF MODIFICATION BEFORE COMMENCING WORK. THE 18. ALL HARDWARE SHALL MAINTAIN THE RESPONSIBILITY FOR ANY CHANGES INTEGRITY OF THE FIRE RATING OF MADE ON THE FIELD WITHOUT PRIOR DOORS. ELECTRICAL NOTIFICATION TO THE ARCHITECT, SHALL REST WITH THE CONTRACTOR OR 19. CONTRACTOR SHALL VERIFY SIZE OF ANY OTI-ER PERSON APPROVING SUCH A ALL DOOR OPENINGS AND EXACT DOOR E -1.0 ELECTRICAL SITE PLAN CHANGE. SWING AS PER ARCHITECTURAL FLOOR PLANS, CONTACT THE ARCHITECT IF ANY E-2.0 GROUND FLOOR ELECTRICAL PLAN 6. ALL DIMENSIONS SHALL BE DISCREPANCIES ARE FOUND BEFORE CONSIDEQED 'NOMINAL' UNLESS NOTED ORDERING DOORS AND /OR FRAMES. E- 2.1 SECOND FLOOR ELECTRICAL PLAN OTHERWISE. WRITTEN DIMENSIONS E-3.0 ELECTRICAL NOTES & SCHEDULES SHALL GOVERN. DO NOT SCALE FROM 20. CAULKING AND SEALANTS, DRAWINGS. DIMENSIONS ON LARGE INSTALLATION SHALL BE GUARANTEED SCALE D2AWINGS OR DETAILS WILL WEATHER TIGHT. EXTERIOR METAL PREVAIL OVER SMALLER SCALED WORK, INCLUDING WINDOWS, PLUMBING DRAWINGS. ALL ANGLES ARE TAKEN AT STOREFRONTS, DOOR FRAMES AND ALL 90 DEGREE UNLESS OTHERWISE NOTED. JUNCTIONS BETWEEN MASONRY, CONCRETE AND METAL SHALL BE P -1.0 PLUMBING SITE PLAN 7. CONTRACTOR WILL BE RESPONSIBLE SEALED WITH NEOPRENE OR FOR OBTAINING ALL NECESSARY PERMITS POLYURETHANE FILLER AND APPROVED P-2.0 GROUND FLOOR PLUMBING PLAN AND INSFECTIONS REQUIRED FOR THE PROJECT, SEALANT COMPOUNDS. P-2.1 SECOND FLOOR PLUMBING PLAN 21. TERMITE TREATMENT, TREAT ALL P-3.0 PLUMBING ISOMETRICS 8. ALL WORK SHALL BE IN COMPLIANCE WITH THE SOUTH FLORIDA BUILDING SOIL UNDER SLAB AND WITHIN A DISTANCE OF 4'- 0' BEYOND ALL P- 3.1 PLUMBING NOTES & DETAILS CODE, LATEST EDITION, ACI 318.33 AND FOOTINGS AND SLAB EDGES AS PER ALL APPLICABLE STATE, LOCAL REQUIREMENTS OF THE FLORIDA STATE REGULATONS AND ORDINANCES HAVING BOARD OF HEALTH, MEMORANDUM 173, JU12ISDIC "ION OVER THE PROJECT. JULY 31,1978. 22. ALL PIPING AND CONDUIT UNDER 9. ALL MANUFACTURERS, SUPPLIERS, AND SLAB SHALL BE A MINIMUM OF 2'-0" FABRICA -ORS SHALL SUBMIT SHOP CLEAR OR UNDERSIDE FOOTING. DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. G� Uz tr� W m � O� 2 � U 8 w F � U # F'� H ONO V � z f may' T-101 g8 "R z A DATE 7f1W JOB NQ 20" DRAWN BY Ef AM BY SHWr NQ AMC A -1.0 Fm AAA {