Loading...
05-1465-000ry i i L SINGLE FAMILY RESIDENCE G. C. HOMES HVAC Load Calculations for G C HOMES 8200 SW 60TH COURT SOUTH MIAMI, FLA "VASRBSIDEM`IYAL HVAC L CADS Prepared By: ,����:;..;..,•: /�� JMM CONSULTING ENGINEERS LLC n ;q .0 Ido. 56018 hednesday, September 14, 2005 0 r � RHVAC - Residential HVAC Load Calculations Elite Software Development, Inc. Jose Martinez P.E. SINGLE FAMILY RESIDENCE G.C. HOMES Miami, FL 33155 Page 2 Project Report General Project Information Check Figures Project Filename C: \Elite \Rhvacw \Projects \TALKINTON RESIDENCE.rhv Project Title* SINGLE FAMILY RESIDENCE G.0 HOMES Designed By* JOSE M MARTINEZ, PE Project Date* 07/20/05 Client Name: G C. HOMES Client Address 8200 SW 60TH COURT Client City. SOUTH MIAMI, FLA. Client Phone. 70,292 Client Fax: 7 Company Name: JMM CONSULTING ENGINEERS LLC Company Representative - Altitude Factor Company Address - Company City. 7.810 Tons (Based On 75% Sensible Capacity) Company Phone. 1.000 Company Fax. Desi n Data Check Figures Reference City. Total Building Supply CFM 3,162 Miami, Florida CFM Per Square Foot: 0 721 Square Feet of Room Area: 4,386 Daily Temperature Range: Square Feet Per Ton. 687.937 Low Latitude 25 Degrees Total Sensible Gain 70,292 Elevation- 7 Feet Btuh 8 % Total Cooling Required With Outside Air- Altitude Factor 1.000 7.810 Tons (Based On 75% Sensible Capacity) Elevation Sensible Adj. Factor. 1.000 Elevation Total Adj Factor- 1.000 Elevation Heating Adj Factor: 1.000 Elevation Heating Adj. Factor- 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter. 40 0 0 70 0 Summer. 92 78 50 75 58 i Check Figures Total Building Supply CFM 3,162 CFM Per Square Foot: 0 721 Square Feet of Room Area: 4,386 Square Feet Per Ton. 687.937 Building Loads Total Heating Required With Outside Air: 58,568 Btuh 58.568 MBH Total Sensible Gain 70,292 Btuh 92 % Total Latent Gain: 6,215 Btuh 8 % Total Cooling Required With Outside Air- 76,507 Btuh 6 376 Tons (Based On Sensible + Latent) 7.810 Tons (Based On 75% Sensible Capacity) I Notes - Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary Be sure to select a unit that meets both sensible and latent loads. C. \Elite \Rhvacw \Projects \TALKINTON RESIDENCE rhv Wednesday, September 14, 2005, 11.06 AM 1 tHVAC - Residential HVAC Load Calculations Elite Software Development, Inc lose Martinez P E. SINGLE FAMILY RESIDENCE G C HOME! Aiami, FL 33155 _ Page System 1 Room Load Summary Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys 1, No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM - -Zone 1 - -- 1 Kitchen 605 6,952 90 0 -0 0 5,892 598 268 100 268 268 2 Family 365 7,788 101 0 -0 0 6,965 526 317 125 396 317 3 Dining 213 1,430 19 0 -0 0 3,547 233 161 100 161 161 4 Library 216 3,559 46 0 -0 0 4,543 253 207 100 207 207 5 Living 412 7,598 99 0 -0 0 8,656 515 394 125 492 394 6 Foyer /gallery 475 5,850 76 0 -0 0 9,475 300 431 1.25 538 431 System 1 total 2,286 33,837 431 39,452 3,210 1,777 2,062 1,777 Cooling System Summary I Cooling Sensible /Latent Sensible Latent Total - Tons Split Btuh Btuh Btuh Net Required 3.555 92%/8% 39,452 3,210 42,662 Recommended: 4.384 75%/25% 39,452 13,151 52,602 Gnllimm�n4 17h4� Type: Model Brand: Efficiency- Sound Capacity Sensible Capacity. Latent Capacity- n/a n/a C* \Elite \Rhvacw \Projects \TALKINTON RESIDENCE rhv 0 Btuh 0 Btuh Wednesday, September 14, 2005, 11.06 AM RHVAC - Residential HVAC Load Calculations Elite Software Development, Inc. Jose Martinez P.E. SINGLE FAMILY RESIDENCE G.0 HOMES Miami, FL 33155 Page 4 , � system z rtoom �oaa summary Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM -- -Zone 1 - -- 349 7 Master Bedrm 424 5,762 75 0 -0 0 6,651 636 302 1.16 349 302 8 Master Bath 396 4,222 55 0 -0 0 4,551 123 207 1 00 207 207 9 Bedrm 2 250 1,609 21 0 -0 0 3,499 457 159 1.00 159 159 10 Bedroom 4 400 4,993 65 0 -0 0 5,701 311 259 1.00 259 259 11 Bedrm 2 317 3,582 47 0 -0 0 5,605 338 255 1.00 255 255 12 Vest 313 3,903 51 0 -0 0 4,459 355 203 1.25 253 203 System 2 total 2,100 24,731 313 30,840 3,005 1,385 1,483 1,385 Cooling System Summary Cooling Sensible /Latent Sensible Latent Total Tons Split Btuh Btuh Btuh ' Net Required: 2.820 91%/9% 30,840 3,005 33,845 Recommended: 3.427 75 %/25% 30,840 10,280 41,120 Equipment Data Heating System Cooling System Type Model Brand: Efficiency Sound- Capacity Sensible Capacity n/a 0 Btuh Latent Capacity. n/a 0 Btuh t: C: \Elite \Rhvacw \Projects \TALKINTON RESIDENCE rhv Wednesday, September 14, 2005, 11 06 AM 0- FORM 60OA -2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name. SINGLE FAMILY RESIDENCE G.C. HOMES TALK Builder- Address 8200 SW 60TH COURT Permitting Office. SOUTH MIAMI City, State SOUTH MIAMI, FL Permit Number- Owner: G.C. HOMES Jurisdiction Number: 233300 Climate Zone. South I. New construction or existing I 2. Single family or multi - family 3. Number of units, if multi - family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Glass area & type Single Pane a Clear glass, default U- factor 628.0'f3 b. Default tint 0 ft, c Labeled U or SHGC 0.0 ft= 8 Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9 Wall types a. Concrete, Int lnsul, Exterior b. Concrete, lnt Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a Under Attic b. N/A c N/A 11. Ducts a. Sup: Unc. Ret Unc AH: Interior b. N/A New — Single family — I — �. 4 — L No _ Do6ne — OOftz — 0.0 ft2 — 0.0 ft2 R =0.0, 531 0(p) ft — RJ4.2, 4682.0 ft' — F{= 4.2, 2250 ft= — j =30.0, 2286.0 W — I — Sup. R =6.0, 300.0 ft — 12. Cooling systems a. Central Unit b Central Unit c. N/A 13. Heating systems a. Electric Strip b. Electric Strip c. N/A 14. Hot water systems a. Electric Resistance b. Electric Resistance c. Conservation credits (HR -Heat recovery, Solar DHP- Dedicated heat pump) 15. HVAC credits (CF- Ceiling fan, CV -Cross ventilation, HF -Whole house fan, PT- Programmable Thermostat, MZ- C- Multizone cooling, MZ- H- Multizone heating) Glass /Floor Area: 0.14 Total as -built points: 47732 PASS Total base points: 61589 Cap: 58.8 )kBtu/hr SEECap. 47 5 SEE Cap: 34.0 kBtu/hr — COP. 1.00 — Cap- 34 0 kBtu/hr — COP: 1.00 — Cap: 80.0 gallons — EF: 0 82 _ Cap: 80.0 gallons — EF. 0.82 — I hereby certify that the plats and specifications covered Review of the plans and sr by this calculation are ir), Wrtpdwjtwith the Florida specifications covered by this yob Energy Code ••• ' calculation indicates compliance PREPAREDsBY:?� with the Florida Energy Code. 44� •A- �L Before construction is completed a v DATE:' :��/6/`'7�i,. this budding will be inspected for I hereby certify that this boil in a es.: d, is in compliance with Section 553.908 fl c ��'l'• Florida Statutes °vWF j compliance with the Florio Energy ode OWNER/AGENT,:E`,'•. �� �?�. • c� BUILDING OFFICIAL: j DATE: N'tea DATE: :.:.v.•.:r *- .tea EnergyGauge® (Version, FLRCSB v3.30) FORM 60OA -2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS 8200 SW 60TH COURT, SOUTH MIAMI, FL, PERMIT #: EnergyGauge® DCA Form 60OA -2001 EnergyGauge® /FlaRES'2001 FLRCSB v3 30 BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type /SC Ornt Len Hgt Area X SPM X SOF = Points .18 4386.0 32.50 25658.1 Single, Clear N 00 00 1550 3646 1 00 5651 7 Single, Clear S 00 00 1400 6693 100 93697 Single, Clear W 00 00 201 0 7053 100 141758 Single, Clear E 00 00 1320 7871 1 00 103899 As -Built Total: 628.0 39587.1 WALL TYPES Area X BSPM = Points Type R -Value Area X SPM = Points Adjacent 2250 100 2250 Concrete, Int Insul, Exterior 42 46820 228 106750 Exterior 46820 270 126414 Concrete, Int Insul, Adjacent 42 2250 1 18 2655 Base Total: 4907.0 12866.4 As -Built Total: 4907.0 10940.5 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 260 546 Adjacent Wood 21 0 380 798 Exterior 00 000 00 Base Total: 21.0 54.6 As -Built Total: 21.0 79.8 CEILING TYPES Area X BSPM = Points Type R -Value Area X SPM X SCM = Points Under Attic 22860 280 64008 Under Attic 300 2286 0 2 77 X 1 00 63322 Base Total: 2286.0 6400.8 As -Built Total: 2286.0 6332.2 FLOOR TYPES Area X BSPM = Points Type R -Value Area X SPM = Points Slab 531 0(p) -200 -106200 Slab -On -Grade Edge Insulation 0 0 531 0(p -2000 -106200 Raised 00 000 00 Base Total: - 10620.0 As -Built Total: 531.0 - 10620.0 INFILTRATION Area X BSPM = Points Area X SPM = Points 43860 1879 824129 43860 1879 824129 EnergyGauge® DCA Form 60OA -2001 EnergyGauge® /FlaRES'2001 FLRCSB v3 30 FORM 60OA -2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS 8200 SW 60TH COURT, SOUTH MIAMI, FL, PERMIT # BASE AS -BUILT Summer Base Points: 116772.8 Summer As -Built Points: 128737 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 1287325 0 553 (1 073 x 1 165 x 0 90) 0 207 1 000 165566 1287325 0 447(1 00 x 1 165 x 1 00 0201 1 000 12981 4 116772.8 0.4266 49815.3 1 128732.5 1.00 1.125 0.204 1.000 29531.5 EnergyGaugeTm DCA Form 60OA -2001 EnergyGauge® /FIaRES'2001 FLRCSB v3 30 FORM 60OA -2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS. 8200 SW 60TH COURT, SOUTH MIAMI, FL, PERMIT # EnergyGauge® DCA Form 60OA -2001 EnergyGauge® /FlaRES'2001 FLRCSB Q 30 BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type /SC Ornt Len Hgt Area X WPM X WOF = Point .18 4386.0 2.36 1863.2 Single, Clear N 00 00 1550 603 1 00 9350 Single, Clear S 00 00 1400 449 1 00 6292 Single, Clear W 00 00 201 0 549 1 00 11039 Single, Clear E 00 00 1320 477 1 00 6298 As -Built Total: 628.0 3298.0 WALL TYPES Area X BWPM = Points Type R -Value Area X WPM = Points Adjacent 2250 050 1125 Concrete, Int Insul, Exterior 42 46820 1 02 47756 Exterior 46820 060 28092 Concrete, Int Insul, Adjacent 42 2250 044 990 Base Total: 4907.0 2921.7 As -Built Total: 4907.0 4874.6 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21 0 1 30 273 Adjacent Wood 21 0 1 90 399 Exterior 00 000 00 Base Total: 21.0 27.3 As -Built Total: 21.0 39.9 CEILING TYPES Area X BWPM = Points Type R -Value Area X WPM X WCM = Points Under Attic 22860 010 2286 Under Attic 300 22860 0.10 X 1 00 2286 Base Total: 2286.0 228.6 As -Built Total: 2286.0 228.6 FLOOR TYPES Area X BWPM = Points Type R -Value Area X WPM = Points Slab 531 0(p) -21 -11151 Slab -On -Grade Edge Insulation 0 0 531 0(p -210 -11151 Raised 00 000 00 Base Total: - 1115.1 As -Built Total: 531.0 - 1115.1 INFILTRATION Area X BWPM = Points Area X WPM = Points 43860 -006 -2632 43860 -006 -2632 EnergyGauge® DCA Form 60OA -2001 EnergyGauge® /FlaRES'2001 FLRCSB Q 30 FORM 60OA -2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS. 8200 SW 60TH COURT, SOUTH MIAMI, FL, PERMIT # BASE AS -BUILT Winter Base Points: 3662.5 Winter As -Built Points: 7062.8 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 70628 0 500 (1 099 x 1 137 x 0 91) 1 000 1 000 40156 70628 0 500(1 00 x 1 137 x 1 00) 1 000 1 000 40156 3662.5 0.6274 2297.9 1 7062.8 1.00 1.137 1.000 1.000 8031.2 EnergyGauge- DCA Form 60OA -2001 EnergyGauge® /FIaRES'2001 FLRCSB v3 30 FORM 60OA -2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS. 8200 SW 60TH COURT, SOUTH MIAMI, FL, PERMIT # BASE CODE COMPLIANCE STATUS AS -BUILT WATER HEATING AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 236900 94760 800 082 4 050 254234 100 50847 800 082 4 050 254234 1 00 50847 As -Built Total: 10169.4 PASS EnergyGaugeTM' DCA Form 60OA -2001 EnergyGauge® /FlaRES'2001 FLRCSB v3 30 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 49815 2298 9476 61589 1 29532 8031 10169 47732 PASS EnergyGaugeTM' DCA Form 60OA -2001 EnergyGauge® /FlaRES'2001 FLRCSB v3 30 FORM 60OA -2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 8200 SW 60TH COURT, SOUTH MIAMI, FL, PERMIT #: 6A -21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE I CHECK Exterior Windows & Doors 606 1 ABC.1 1 I Maximum 3 cfm/sq ft. window area, 5 cfm /sqA door area Exterior & Adjacent Walls 6061 ABC 1 21 Caulk, gasket, weatherstrip or seal between windows /doors & frames, surrounding wall, Swimming Pools & Spas 6121 foundation & wall sole or sill plate, points between exterior wall panels at corners, utility penetrations, between wall panels & top /bottom plates; between walls and floor EXCEPTION Frame walls where a continuous infiltration barrier is installed that extends Shower heads 16121 from, and is sealed to, the foundation to the top plate Floors 6061 ABC 1 2 2 Penetrations /openings >1/8" sealed unless backed by truss or joint members EXCEPTION Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams Ceilings 606 1 ABC 1 2 3 Between walls & ceilings, penetrations of ceding plane of top floor, around shafts, chases, Insulation 604 1, 602 1 soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate, Common ceding & floors R -11 attic access EXCEPTION Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams Recessed Lighting Fixtures 6061 ABC 1 2 4 Type IC rated with no penetrations, sealed, or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation, or Type IC rated with < 2 0 cfm from conditioned space tested _ Multi -story Houses 606 1 ABC 1 2 5 Air barrier on perimeter of floor cavity between floors Additional Infiltration reqts 6061 ABC 1 3 Exhaust fans vented to outdoors, dampers, combustion space heaters comply with NFPA, have combustion air RA_99 f%T41PD DD =Qd- DIDTIVG MPAQ 11?FC /muct ho mot nr aircaatlad by alt ranirlancac_1 COMPONENTS I SECTION I REQUIREMENTS I CHECK Water Heaters 6121 Comply with efficiency requirements in Table 6 -12 Switch or clearly marked circuit breaker (electric) or cutoff gas must be provided External or built -in heat trap rice uired Swimming Pools & Spas 6121 Spas & heated pools must have covers (except solar heated) Non - commercial pools must have a pump timer Gas spa & pool heaters must have a minimum thermal efficiency of 78% Shower heads 16121 Water flow must be restricted to no more than 2 5 gallons per minute at 80 PSIG�✓ Air Distribution Systems 6101 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610 Ducts in unconditioned attics R-6 min insulation HVAC Controls 1607.1 I Separate readily accessible manual or automatic thermostat for each system Insulation 604 1, 602 1 Ceilings -Min R -19 Common walls -Frame R -11 or CBS R -3 both sides Common ceding & floors R -11 EnergyGaugeTm DCA Form 60OA -2001 EnergyGauge® /FlaRES'2001 FLRCSB v3 30 i i ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.9 The higher the score, the more efficient the home. G C HOMES, 8200 SW 60TH COURT, SOUTH MIAMI, FL, 1. New construction or existing 2. Single family or multi - family 3. Number of units, if multi- family - 4 Number of Bedrooms 5. Is this a worst case? 6 Conditioned floor area (ft2) 7. Glass area & type SEER: 17.00 _ a. Clear - single pane c. N/A b. Clear - double pane Single Pane Double Pane c. Tint/other SHGC - single pane d. Tint/other SHGC - double pane 8. Floor types 0.0 ft2 0.0 ft2 _ a. Slab -On -Grade Edge Insulation Cap: 34 0 kBtu/hr _ b. N/A c. N/A 9. Wall types Cap: 34 0 kBtu/hr _ a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent R =0.0, 531.0(p) ft _ c. N/A _ d. N/A 14 Hot water systems e. N/A 10. Ceiling types a. Electric Resistance a. Under Attic R=4 2, 4682.0 ft2 _ b. N/A EF: 0 82 _ c. N/A 11. Ducts _ a. Sup. Unc. Ret. Unc. AH: Interior EF: 0 82 _ b N/A New _ 12. Cooling systems Single family _ a Central Unit Cap. 58.8 kBtu/hr 1 _ SEER. 16.50 _ 4 _ b. Central Unit Cap- 47.5 kBtu/hr No _ SEER: 17.00 _ 4386 ft' c. N/A Single Pane Double Pane 628.0 ft2 0 0 ft2 _ 13. Heating systems 0.0 ft2 0.0 ft2 _ a. Electric Strip Cap: 34 0 kBtu/hr _ 0.0 ft2 0.0 ft2 _ COP: 1.00 _ b. Electric Strip Cap: 34 0 kBtu/hr _ _ COP: 100 R =0.0, 531.0(p) ft _ c. N/A _ 14 Hot water systems _ a. Electric Resistance Cap. 80 0 gallons R=4 2, 4682.0 ft2 _ EF: 0 82 _ R =4.2, 225.0 ft2 _ b. Electric Resistance Cap: 80 0 gallons _ _ EF: 0 82 _ _ c Conservation credits _ (HR -Heat recovery, Solar DHP- Dedicated heat pump) R =30 0, 2286 0 ft2 _ 15. HVAC credits (CF- Ceiling fan, CV -Cross ventilation, HF -Whole house fan, PT- Programmable Thermostat, Sup R =6.0, 300.0 ft _ MZ- C- Multizone cooling, MZ -H- Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: THB sr9T�o� � a f�C0 tr WE *NOTE: The home's estimated energy performance score is only available through the FLARES computer program This is not a Building Energy Rating. !f your score is 80 or greater (or 86 for a US EPA /DOE EnergyStar'Mdesignation), your home may qualms for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638 -1492 or see the Energy Gauge web site at www fsec. ucf edu for information and a list of certified Raters For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community AffairgWroft eMprsion: FLRCSB v3.30)