05-1121-006COOG
2 WAY)/
EXISTING 4" SANITARY
OLD DRAIN. VERIFY
EXACT LOCATION BEFORE
JOB COMMENCEMENT.
PROVIDE 2" AIR ADMITTANCE VALVE.
(TYPICAL)
I.M.
�--- 1" IW
SINK -1 - PROVIDE P -TRAP WITH
I HUB.
DW `�/ U
CO I
2" 2n
2' SAN. (4 FU)
NOTE:
• ALL HORIZONTAL DRAIN PIPE 2'0 OR
SMALLER SHALL BE SLOPED AT 1 /4 " /FT
• ALL HORIZONTAL DRAIN PIPE 3 "0 OR LARGER
SHALL BE SLOPED AT 1 /8' /FT. MIN.
VERY IMPORTANT NOTE:
ICE MAKER P -TRAP HEIGHT SHALL BE COORDINATED
BEFORE JOB COMMENCEMENT.
EXISTING 3" SANITARY
LINE. VERIFY
EXACT LOCATION BEFORE
TIE -IN TO EXISTING JOB COMMENCEMENT.
3" SANITARY BLDG
DRAIN.VERIFY EXACT
LOCATION AND INVERT
BEFORE JOB COMMENCEMENT. \\
I.M.
1" IW - Q l
PROVIDE P -TRAP WITH
HUiu.
APPROVED BACK FLOW
PREVETOR (EQUAL WATT SD -2)
(T')
i
I I" \
SINK -1
DW
-y�
MINI -SHOCK ABSORBER
TYPE "AA" (TYP.)
I
II
2"
SANITARY PIPING ISOMETRIC - NTS
TIE -IN TO EXISTING
3" SANITARY DRAIN.
VERIFY EXACT.
LOCATION AND INVERT
BEFORE JOB COMMENCEMENT.
2' SAN. (2 FU)
PLUMBING FIXTURE CONNECTION SCHEDULE
NO,
DESCRIPTION
DRAIN
WATER
REMARKS
COLD
HOT
SINK
KITCHEN SINK
1 1/2'
1/2'
1/2'
PROVIDE 2.5 GPM FAUCET
DW
'DISHWASHER
---
- --
1/2"
1" INDIRECT WASTE
IM
ICE MAKER
---
1/2"
- --
1" INDIRECT WASTE
RESIDE CE
RENOVATION
8280 SW 59TH AVE
MIAMI, FL 33143
APPROVED BY OWNER:
NOTES: 1., ALL FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE WATER CONSERVATION STANDARDS.
\�
1/2"
IM I
TIE -IN TO EXISTING
3/4" CW AND 1/2' HW
PIPING . VERIFY
r., LOCATION AND INVERT
1/2 BEFORE JOB COMMENCEMENT.
TIE -IN TO EXISTING
1/2" CW PIPING IN PARTITION
WALL . VERIFY LOCATION
AND INVERT BEFORE JOB
COMMENCEMENT.
WATER PIPING ISOMETRIC - NTS
WALL
FACE OF WALL
STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG.
TYPICAL CLEANOUT DETAIL
GENERAL PLUMBING NOTES:
1. A. ALL WORK SHALL BE DONE in accordance with the Florida
Building Code and with all applicable regulations.
B. DRAWINGS: Refer to all drawings for coordination of the
plumbing work.
C. ARRANGE AND PAY for all permits, licenses, inspections
and tests. Obtain the required certificates and present
to owner.
D. GUARANTEE: The completed installation shall be fully
guaranteed against defective materials and /or improper
workmonship for a minimum of one year for material and
labor.
E. ALL HORIZONTAL SANITARY PIPING 3" and larger shall slope
at 1/8 inch per foot minimum, unless noted otherwise.
per foot minimum, unless noted otherwise. All piping 2" and
smaller shall slope at 1 /4'inch per foot minimum.
2. SHOP DRAWINGS: Contractor shall submit for approval, within
30 days of signing contract, a minimum of five copies of fully
descriptive literature, including but not limited to: water
heaters, and plumbing fixtures. No work shall proceed without
the approval of these submittals.
3. PLUMBING FIXTURES: Fixtures shall be as selected by architect
and shall be furnished and installed by this contractor.
Fixtures shall be complete with drains, traps, supplies and
any other accessory required.
4, MATERIALS:
A. PIPING:
a. Soil, waste and vent, and storm: Sanitary pipe, PVC, DWV,
Schedule 40.
b. Domestic water: Copper pipe, Type L with sweat wrought
copper fittings. Type "M" in concealed spaces is
acceptable. Isolate piping from concrete with
insulating material.
c. Domestic water supply assembly. Chrome finish tubing
with angle shut off valves.
B. Insulation:
a. Hot water & hot water return: Provide 1/2" thick fiberglass
pipe nsulation with jacket and self sealing flaps,
5. PIPING TEST AND DISINFECTIONS:
A. Test: All sanitary and domestic water supply piping shall
be tested for leaks before piping is concealed or connected
to equipment and plumbing fixtures.
B. Disinfection: All domestic water piping shall be
disinfected by introducing a solution of calcium
hypochlorite of 50 parts per million of chloride and as
per AWWA Standards.
6. CONTRACTOR SHALL COORDINATE exact location of sanitary, storm
and domestic water piping before starting any work. Notify
Architect /Engineer of any deviations from design drawings.
7. CLEANOUTS:
A. Wall: Josam 58890 -15
8. CONTRACTOR to fire protect and seal all openings and pipe
penetrations thru fire rated walls and ceiling. Materials and
methods of fire rating shall be approved by the local
product control oproval department and shall be U.L. listed.
9. PROVIDE CEILING /WALL ACCESS DOORS where indicated on drawings
and when required to access mechanical equipment and valves.
Doors shall be recessed type, fire rated if in fire rated wall or ceilings.
As manufactured by Karp model RDW and KATR.
10. PLUMBING CONTRACTOR SHALL review structural and demolition drawings
prior to bidding to fully familiarize himself with project.
�v
I1r
.a
0
1
E'
x
�s
CA: 9289
PROTEK
E NG rNEERING
➢I R PUISSIUA Jl1D o AND f f EST If ffl Em
AND DEi. ,DESIGN M Ns RVING3IS Stl AND MKS
D APPIICADLE ES AND 11WIDNS.
9702 SW 131 ST. MIAMI FL 33176
TEL:(305) 238 -4977 FX: (306) 252 -0028
Gustavo S, Frances PE. A. License #48996
Edward Chen PE, A. Lic nce # 61068
RESIDE CE
RENOVATION
8280 SW 59TH AVE
MIAMI, FL 33143
APPROVED BY OWNER:
w` ATEN
t41
COPYRIGHT (g2004
I
AL IDE4S, DESIGNS AND DETAILS INDICATED
OR F2EE�0 ESENTED BY THIS DRAWING ARE
THPI�OPERTY OF PROTEK ENGINEERING
AN WEVE CREATED AND DEVELOPED
FOR UkSE.ON AND IN CONNECTION WITH THE
SPECIFI ;Q PROJECT, AND SHALL NOT BE ALTERED,
r CHANGED, MODIFIED OR COPIED WITHOUT
WRITTEN PERMISSION FROM A PRINCIPAL
OF THE FIR1a OR BE LIABLE FOR THE FULLEST.
7
GENERAL NOTt:
1. CONTRACTOR I, SHALL VERIFY ALL
EXLQTINn. `,IONS AND DETAILS IN
CONSTRUCTION WORK
)R HIS REPRESENTATNES
SHIT
€CT ON.RECOR0 LI'01SCREPANC19S ON,&
r NOTIFIED WITH ANY "TO ANY NEW
THE DRAWINGS
PRIOR'
CONSTRUCTION WOR.
i
t .=
t Issue Date: 07-14-05
i Project No.: 050613
's
Drawn bi A.D
Approveq by: E.C.
Revision/Date
SEAL I SIGNATURE
e 199a
Ii=
LCence # 48996
$;a( 2005
�o�aul
SANITARY AN!)'NATER
, SERS,,8CHEDULE 1',Na. NOT S.
a .4SCAL` At) NOTED
i P�IIIIIIIIIIIIIIIIi 3
Date: 07/07/05
t