05-1121-006COOG 2 WAY)/ EXISTING 4" SANITARY OLD DRAIN. VERIFY EXACT LOCATION BEFORE JOB COMMENCEMENT. PROVIDE 2" AIR ADMITTANCE VALVE. (TYPICAL) I.M. �--- 1" IW SINK -1 - PROVIDE P -TRAP WITH I HUB. DW `�/ U CO I 2" 2n 2' SAN. (4 FU) NOTE: • ALL HORIZONTAL DRAIN PIPE 2'0 OR SMALLER SHALL BE SLOPED AT 1 /4 " /FT • ALL HORIZONTAL DRAIN PIPE 3 "0 OR LARGER SHALL BE SLOPED AT 1 /8' /FT. MIN. VERY IMPORTANT NOTE: ICE MAKER P -TRAP HEIGHT SHALL BE COORDINATED BEFORE JOB COMMENCEMENT. EXISTING 3" SANITARY LINE. VERIFY EXACT LOCATION BEFORE TIE -IN TO EXISTING JOB COMMENCEMENT. 3" SANITARY BLDG DRAIN.VERIFY EXACT LOCATION AND INVERT BEFORE JOB COMMENCEMENT. \\ I.M. 1" IW - Q l PROVIDE P -TRAP WITH HUiu. APPROVED BACK FLOW PREVETOR (EQUAL WATT SD -2) (T') i I I" \ SINK -1 DW -y� MINI -SHOCK ABSORBER TYPE "AA" (TYP.) I II 2" SANITARY PIPING ISOMETRIC - NTS TIE -IN TO EXISTING 3" SANITARY DRAIN. VERIFY EXACT. LOCATION AND INVERT BEFORE JOB COMMENCEMENT. 2' SAN. (2 FU) PLUMBING FIXTURE CONNECTION SCHEDULE NO, DESCRIPTION DRAIN WATER REMARKS COLD HOT SINK KITCHEN SINK 1 1/2' 1/2' 1/2' PROVIDE 2.5 GPM FAUCET DW 'DISHWASHER --- - -- 1/2" 1" INDIRECT WASTE IM ICE MAKER --- 1/2" - -- 1" INDIRECT WASTE RESIDE CE RENOVATION 8280 SW 59TH AVE MIAMI, FL 33143 APPROVED BY OWNER: NOTES: 1., ALL FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE WATER CONSERVATION STANDARDS. \� 1/2" IM I TIE -IN TO EXISTING 3/4" CW AND 1/2' HW PIPING . VERIFY r., LOCATION AND INVERT 1/2 BEFORE JOB COMMENCEMENT. TIE -IN TO EXISTING 1/2" CW PIPING IN PARTITION WALL . VERIFY LOCATION AND INVERT BEFORE JOB COMMENCEMENT. WATER PIPING ISOMETRIC - NTS WALL FACE OF WALL STAINLESS STEEL COVER SCREWED TO THREADED C.O. PLUG. TYPICAL CLEANOUT DETAIL GENERAL PLUMBING NOTES: 1. A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the plumbing work. C. ARRANGE AND PAY for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmonship for a minimum of one year for material and labor. E. ALL HORIZONTAL SANITARY PIPING 3" and larger shall slope at 1/8 inch per foot minimum, unless noted otherwise. per foot minimum, unless noted otherwise. All piping 2" and smaller shall slope at 1 /4'inch per foot minimum. 2. SHOP DRAWINGS: Contractor shall submit for approval, within 30 days of signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: water heaters, and plumbing fixtures. No work shall proceed without the approval of these submittals. 3. PLUMBING FIXTURES: Fixtures shall be as selected by architect and shall be furnished and installed by this contractor. Fixtures shall be complete with drains, traps, supplies and any other accessory required. 4, MATERIALS: A. PIPING: a. Soil, waste and vent, and storm: Sanitary pipe, PVC, DWV, Schedule 40. b. Domestic water: Copper pipe, Type L with sweat wrought copper fittings. Type "M" in concealed spaces is acceptable. Isolate piping from concrete with insulating material. c. Domestic water supply assembly. Chrome finish tubing with angle shut off valves. B. Insulation: a. Hot water & hot water return: Provide 1/2" thick fiberglass pipe nsulation with jacket and self sealing flaps, 5. PIPING TEST AND DISINFECTIONS: A. Test: All sanitary and domestic water supply piping shall be tested for leaks before piping is concealed or connected to equipment and plumbing fixtures. B. Disinfection: All domestic water piping shall be disinfected by introducing a solution of calcium hypochlorite of 50 parts per million of chloride and as per AWWA Standards. 6. CONTRACTOR SHALL COORDINATE exact location of sanitary, storm and domestic water piping before starting any work. Notify Architect /Engineer of any deviations from design drawings. 7. CLEANOUTS: A. Wall: Josam 58890 -15 8. CONTRACTOR to fire protect and seal all openings and pipe penetrations thru fire rated walls and ceiling. Materials and methods of fire rating shall be approved by the local product control oproval department and shall be U.L. listed. 9. PROVIDE CEILING /WALL ACCESS DOORS where indicated on drawings and when required to access mechanical equipment and valves. Doors shall be recessed type, fire rated if in fire rated wall or ceilings. As manufactured by Karp model RDW and KATR. 10. PLUMBING CONTRACTOR SHALL review structural and demolition drawings prior to bidding to fully familiarize himself with project. �v I1r .a 0 1 E' x �s CA: 9289 PROTEK E NG rNEERING ➢I R PUISSIUA Jl1D o AND f f EST If ffl Em AND DEi. ,DESIGN M Ns RVING3IS Stl AND MKS D APPIICADLE ES AND 11WIDNS. 9702 SW 131 ST. MIAMI FL 33176 TEL:(305) 238 -4977 FX: (306) 252 -0028 Gustavo S, Frances PE. A. License #48996 Edward Chen PE, A. Lic nce # 61068 RESIDE CE RENOVATION 8280 SW 59TH AVE MIAMI, FL 33143 APPROVED BY OWNER: w` ATEN t41 COPYRIGHT (g2004 I AL IDE4S, DESIGNS AND DETAILS INDICATED OR F2EE�0 ESENTED BY THIS DRAWING ARE THPI�OPERTY OF PROTEK ENGINEERING AN WEVE CREATED AND DEVELOPED FOR UkSE.ON AND IN CONNECTION WITH THE SPECIFI ;Q PROJECT, AND SHALL NOT BE ALTERED, r CHANGED, MODIFIED OR COPIED WITHOUT WRITTEN PERMISSION FROM A PRINCIPAL OF THE FIR1a OR BE LIABLE FOR THE FULLEST. 7 GENERAL NOTt: 1. CONTRACTOR I, SHALL VERIFY ALL EXLQTINn. `,IONS AND DETAILS IN CONSTRUCTION WORK )R HIS REPRESENTATNES SHIT €CT ON.RECOR0 LI'01SCREPANC19S ON,& r NOTIFIED WITH ANY "TO ANY NEW THE DRAWINGS PRIOR' CONSTRUCTION WOR. i t .= t Issue Date: 07-14-05 i Project No.: 050613 's Drawn bi A.D Approveq by: E.C. Revision/Date SEAL I SIGNATURE e 199a Ii= LCence # 48996 $;a( 2005 �o�aul SANITARY AN!)'NATER , SERS,,8CHEDULE 1',Na. NOT S. a .4SCAL` At) NOTED i P�IIIIIIIIIIIIIIIIi 3 Date: 07/07/05 t