05-1121-005TAG APPLIANCES QTY G1 ELECTRIC GENERATOR SUMMARY LPG: PROPANE LOAD: 672.5.0 KBTU -Hr SERVICE SIZE LOW PRESSURE: SERVICE SIZE HIGH PRESSURE: 1 1/2' EQUPMENT CONSUMPTION 672,500 BTH -Hr 1/2" "0 WITH LONGEST RUN:70 LF 3/4"0 LONGEST RUN:70 LF 28' -0' PRESSURE REDUCER 2ND STEP OF LOW PRESSURE AND SHUT -OFF VALVE BY GAS CO. 3/4' RUN PIPING AT WALL 3/4' 125 GALLONS MAX. CAP. ABOVEGROUND TANK NOTE: 1. -ABOVE GROUND GAS PIPING SHALL BE BLACK STEEL SCH. 40 WITH MALEABLE IRON FITTING 2. -UNDER GROUND iGAS PIPING SHALL BE CUPPPER PIPE TYPE L WITH NO JOINTS UNDER GROUND ENCASE IN PVC CONDUIT VENTED TO THE EXTERIOR. GAS TANK CALCULATION ELECTRIC GENERATOR OF 60 KW -HR LPG CONSUMPTION LP -2500 BTU /CF 100 % POWER RATING ELECTRIC GENERATOR = 269 CF -Hr LPG CONSUMPTION = 269 X 2500 BTU = 672,500 BTH -Hr LPG CONSUMPTION 50 % POWER DEMAND ELECTRIC GENERATOR = 135 CF -Hr LPG CONSUMPTION = 135 X 2500 BTU = 337,500 BTH -Hr CAPACITY TANK= (337, 500 BTH -Hr /95,0)00 BTU -Hr/ GL -Hr) X 16 Hr x 3 DAYS.= (1) 170 GL PROVIDE NEW TANK OF 120 GAL CONNECTED WITH EXISTING 140 GL PROPANE GAS TANK. PROPANE GABS RISER DIAGRAM N.T.S. EQUIPMENT SHALL BE SELECTED BY OWNER /ARCH. IN COMPLIANCE AS PER SECTION 917 FBC. RESIDENTIAL EQUIPMENT SHALL BE PROVIDED TANK LOCATION SHALL BE AS PER FUEL GAS FBC -2001 AND NFPA -58 LAST EDITION. NEW PRESSURE REDUCER FIRST STEP OF HEIGHT PRESSURE BY GAS CO. NEW 120 GAL PROPANE GAS TANK. PROVIDE SHUTOFF VALVE BY PASS NORMALLY OPENED. NEW HEIGHT PRESSURE LINE CONNECTED TO EXISTING 3/4' HEIGHT PRESSURE LINE IN EXISTING PROPANE TANK. 20'-0' 3/4' TIE -IN TO EXISTING HEIGHT PRESSURE LINE. VERIFY LOCATION AT SITE. EXISTING 3/4' LINE NEW PRESSURE REDUCER FIRST STEP OF HEIGHT PRESSURE AND SHUT -OFF VALVE. BY GAS CO. EXISTING GAS TANK TO REMAIN. I I I � I � � 1 � I x JAS RISER SCALE: AS NOTED P�2 Date: 07/07105 CA: 9289 PROTEK ENGINEERING ➢I Ml PR�SSI[1~IAl JUD(lElfi AND iff �Si ff MI AND DE ff, ISIGN N IRIS ➢RAVINGS IS Wl AND CI➢PI.IES VIiH APPLICABLE ms AND REGII.AiD & 9702 SW 131 ST. MIAMI FL 33176 TEL(305) 238 -4977 FX: (305) 262.0028 Gustavo S. Frances PE. Fl. License 948996 Edward Chen PE, A. Licence # 61068 RESIDENCE RENOVATION 8280 SW 59TH AVE MIAMI, FL 33143 APPROVED BY OWNER- DATE: COPYRIGHT Q2004 ALL IDEAS, DESIGNS AND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE THE PROPERTY OF PROTEK ENGINEERING AND WERE CREATED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT, AND SHALL NOT BE ALTERED, CHANGED, MODIFIED OR COPIED WITHOUT WRITTEN PERMISSION FROM A PRINCIPAL OF THE FIRM OR BE LIABLE FOR THE FULLEST. GENERAL NOTE: 1. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND DETAILS IN FIELD PRIOR TO NEW CONSTRUCTION WORK 2. ARCHITECT ON RECORD OR HIS REPRESENTATIVES BE NOTIFIED WITH ANY DISCREPANCIES ON THE DRAWINGS PRIOR TO ANY NEW CONSTRUCTION WORK. Issue Date: 07-14-05 Project No.: 050613 Drawn by: A.D Approved by: E.C. Revision/Date SEAL / SIGNATURE F. *` Cr t � Sig F� ; G. S: FRANCES,PE Fl. Licence # 48996 18, JULY 2005 JAS RISER SCALE: AS NOTED P�2 Date: 07/07105