Loading...
07-421-009LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT LIGHTING F5 NUMBER DESIGNATES FIXTURE TYPE - SEE LIGHTING FIXTURE SCHEDULE SYSTEM F5 ALL FIXTURES IN THIS SPACE SHALL BE THE SAME TYPE INDICATED EXTENT OF CONDUITe O ®SURFACE 3' -10' AFF TO CL OR RECESSED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) FIRE ALARM MANUAL PULL STATION - KEY OPERATED 3' -10' AFF TO CL ®SURFACE FIRE ALARM 10' BELL OR RECESSED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT FIXTURE (TYPE DETERMINES MOUNTING) FD FIRE ALARM CHIME WITH LIGHT ®SURFACE ® OR RECESSED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. FIXTURE (TYPE DETERMINES MOUNTING) VENDOR O4 0 0 SURFACE OR RECESSED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) FIRE ALARM SPEAKER THROUGHOUT ® ® CIRCUIIT FIXTURE (TYPE FLUORESCENT E DETERMINES OUNTING)TED TO EMERGENCY "E ® ® SURFACE OR RECESSED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. FIXTURE (TYPE DETERMINES MOUNTING) OH ® SURFACE OR SUSPENDED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) is ® SORFACE OR SUSPENDED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT. FIXTURE (TYPE DETERMINES MOUNTING) EDR ® SURFACE OR SUSPENDED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. FIXTURE (TYPE DETERMINES MOUNTING) RI [ Q WALL BRACKET FIXTURE FS-A-11 SMOKE DETECTOR ALARM REMOTE INDICATOR /TEST SWITCH CIRCUIT RACKET FIXTURE CONNECTED TO EMERGENCY SPRINKLER SYSTEM VALVE STATUS SWITCH WALL BRACKET FIXTURE CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. Fs ®� EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED ON PLANS FACP I 'D POLE MOUNTED LIGHT FIXTURE FAAN SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 3' -10' AFF TO CL SINGLE POLE SWITCH - RED TOGGLE 3' -10' AFF TO CL S2 DOUBLE POLE SWITCH - CENTER OFF 3' -10' AFF TO CL S3 THREE WAY SWITCH - IVORY TOGGLE 3' -10' AFF TO CL $T MOTOR RATED SWITCH WITH THERMAL OVERLOAD SD DIMMER SWITCH 3' -10' AFF TO CL $IT INTERVAL TIMER SWITCH 3' -10' AFF TO CL POWER - RECECPTACLES AS NOTED SEE SPECS. 120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) 1' -6' AFF TO CL V -6' AFF TO CL 120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) AS NOTED OR SEE SPECS AS NOTED SEE SPECS. 120V. OUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) V -6' AFF TO CL 120V. OUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) AS NOTED OR SEE SPECS e-- SPECIAL RECEPTACLE (TYPE AS NOTED) AS NOTED OR SEE SPECS �-- 120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT) AS NOTED OR SEE SPECS O— 120V. GFI RECEPTACLE V -6' AFF TO CL Q JUNCTION BOX GB GROUNDING COLLECTION BUS - - -- EXPOSED CONDUIT ON WALL OR CEILING SOUND SYSTEM Ps CEILING PAGING SPEAKER CEILING MTD. NON- FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) CEKh COMBINATION MOTOR STARTER ® FACTORY WIRED CONTROLLER OR EQUIPMENT MOTOR CONNECTION (NUMER INSIDE SYMBOL INDICATES HP) 0 UNIT HEATER CONNECTION DUCT HEATER CONNECTION = PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED GAP I GENERATOR ANNUNCIATOR PANEL a PULL BOX ® EMERGENCY LIGHTING TRANSFER RELAY LEGEND - -- SYMBOL DESCRIPTION MOUNTING HbGffT - FIRE ALARM ,F FIREFIGHTER'S TELEPHONE JACK SYSTEM E> FIRE ALARM VISUAL STATION - LIGHT ONLY EXTENT OF CONDUITe O FIRE ALARM MANUAL PULL STATION 3' -10' AFF TO CL OK FIRE ALARM MANUAL PULL STATION - KEY OPERATED 3' -10' AFF TO CL F • FIRE ALARM 10' BELL 7' -0' AFF TO CL FD FIRE ALARM CHIME WITH LIGHT VENDOR ® FIRE ALARM CHIME VENDOR O4 FIRE ALARM HORN FIRE ALARM ® FIRE ALARM SPEAKER THROUGHOUT Q MAGNETIC DOOR HOLDER 11-09 BELOW CLG "E FIRE ALARM SMOKE DETECTOR ('E' INDICATES ELEVATOR RECALL) CEILING OH HEAT DETECTOR is DUCT SMOKE DETECTOR - SUPPLY DUCT EDR DUCT SMOKE DETECTOR - RETURN DUCT RI SMOKE DETECTOR REMOTE INDICATOR FS-A-11 SMOKE DETECTOR ALARM REMOTE INDICATOR /TEST SWITCH SPRINKLER SYSTEM VALVE STATUS SWITCH Fs SPRINKLER SYSTEM FLOW SWITCH FACP I FIRE ALARM CONTROL PANEL FAAN FIRE ALARM ANNUNCIATOR PANEL ® FIRE ALARM RELAY ❑z FIRE ALARM ZONE ADDRESSABLE MODULE NOTES: EC= ELECTRICAL CONTRACTOR O2 NOT USED STUB -UP TO ABOVE ACCESSIBLE CEILING SPACE IN CORRIDOR, TERMINATE WITH PLASTIC BUSHING. Q VENDOR CONTRACTED DIRECTLY BY OWNER. TELEPHONE /DATA TELEPHONE OUTLET WITH PLATE 1 AFF TO CL W WALL TELEPHONE OUTLET WITH PLATE 4'-6' AFF TO CL TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. 44 COMBINATION DATA /TELEPHONE OUTLET WITH PLAT V -6' AFF TO CL COMBINATION DATA /TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. Q DATA OUTLET WITH PLATE V -6' AFF TO CL Q- DATA OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. PBX TELEPHONE SWITCHBOARD CONSOLE CABLE /MAN SYSTEM a MATV OUTLET FOR WALL MOUNTED TV (ANTENNA,& REMOTE CONTROL SEE MANUFACTURERS DETAIL) 88'AFF MISCELLANEOUS CONDUIT CONCEALER CONDUIT BELOW GRADE - ON SITE HOMERUN CONDUIT (QUANTITY OF ARROWS DETERMINES NUMBER OF CIRCUITS) - - -- EXPOSED CONDUIT ON WALL OR CEILING CAPPED CONDUIT =b NON- FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) CEKh COMBINATION MOTOR STARTER ® FACTORY WIRED CONTROLLER OR EQUIPMENT MOTOR CONNECTION (NUMER INSIDE SYMBOL INDICATES HP) 0 UNIT HEATER CONNECTION DUCT HEATER CONNECTION = PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED GAP I GENERATOR ANNUNCIATOR PANEL a PULL BOX ® EMERGENCY LIGHTING TRANSFER RELAY LEGEND SYMBOL DESCRIPTION MOUNTING - ---- - HEIGHT ABBREVIATIONS ABC ABOVE COUNTER SYSTEM AFF ABOVE FINISHED FLOOR EXTENT OF CONDUITe AFG ABOVE FINISHED GRADE NOTES: C RED - EMERGENCY POWER VENDOR CLG CEILING VENDOR FBO FURNISHED BY OTHERS VENDOR IG ISOLATED GROUND VENDOR S SAFETY TYPE FIRE ALARM SMH SPECIAL MOUNTING HEIGHT - AS NOTED OR SEE SPECS THROUGHOUT TV TELEVISION WP WEATHERPROOF BID NOTE IT SHALL BE THE RESPONSIBILITY OF THE CONSTRUCTION MANAGER (CM), GENERAL CONTRACTOR (GC), AND THE SUB - CONTRACTORS (SO TO STUDY ALL THE DRAWINGS AND DETAILS SO THAT THE INSTALLATION OF ALL NEW WORK CAN BE FULLY COORDINATED. THE CM, GC, AND SC SHALL VISIT THE SITE, INCLUDING DOING AN ABOVE CEILING INSPECTION, DURING BIDDING TO SATISFY HIMSELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND /OR SITE CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IN WRITING PRIOR TO BID DUE DATE. FAILURE TO DO SO WILL NOT BE ALLOWED ON A BASIS FOR ADDITIONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWINGS. SYSTEMS RESPONSIBILTY SCHEDULE SYSTEM INTERIOR CABLE FURNISHED BY: INTERIOR CABLE INSTALLED BYi EXTENT OF CONDUITe EQUIPMENT FURNISHED BY: EQUIPMENT INSTALLED BY: NOTES: TELEPHONE /DATA VENDOR VENDOR Q VENDOR VENDOR 0 COMPUTER VENDOR VENDOR 3 VENDOR VENDOR 4 FIRE ALARM EC EC THROUGHOUT EC EC NOTES: EC= ELECTRICAL CONTRACTOR O2 NOT USED STUB -UP TO ABOVE ACCESSIBLE CEILING SPACE IN CORRIDOR, TERMINATE WITH PLASTIC BUSHING. Q VENDOR CONTRACTED DIRECTLY BY OWNER. BID NOTE IT SHALL BE THE RESPONSIBILITY OF THE CONSTRUCTION MANAGER (CM), GENERAL CONTRACTOR (GC), AND THE SUB - CONTRACTORS (SO TO STUDY ALL THE DRAWINGS AND DETAILS SO THAT THE INSTALLATION OF ALL NEW WORK CAN BE FULLY COORDINATED. THE CM, GC, AND SC SHALL VISIT THE SITE, INCLUDING DOING AN ABOVE CEILING INSPECTION, DURING BIDDING TO SATISFY HIMSELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND /OR SITE CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IN WRITING PRIOR TO BID DUE DATE. FAILURE TO DO SO WILL NOT BE ALLOWED ON A BASIS FOR ADDITIONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWINGS. BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 ENGINEER: ENGINEER INFORMATION Smith SS11 Secan Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX- (954) 421 -1466 www.ssr - inc.com Firm Certification - EB- 0000857 Alfred Eequivel PE - 46863 Bruoe W. Peek PE - 36901 Donald Netinho PE-48464 Nelson R. Long PE - 62294 John E. Moulder PE - 33200 SSR JOB # 0632086.0 !. REVISIONS: PROJECT NAME: SMH - ADVANCE TOWER OFFICES - 2ND FLOOR PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 KEY PLAN COMM. NO. 40030.100 SCALE: DATE: OCTOBER 16,20W DRAWN: CHECKED: CADD FILE: DRAWING TITLE: LEGEND, SCHEDULES, & DRAWING INDEX SHEET NO. ELECTRICAL DRAWING INDEX SHEET NO. DESCRIPTION E -0.1 LEGEND, SCHEDULES, AND DRAWING INDEX - ELECTRICAL E -1.1 2ND FLOOR PLAN - DEMOLITION - PHASE A - ELECTRICAL E -2.1 2ND FLOOR PLAN - NEW WORK - PHASE A - LIGHTING E -3.1 2ND FLOOR PLAN - NEW WORK - PHASE A - POWER E -4.1 2ND FLOOR PLAN - NEW WORK - PHASE A - SYSTEMS E -5.1 PARTIAL POWER RISER DIAGRAM & PANEL SCHEDULES E -6.1 ELECTRICAL SPECIFICATIONS BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 ENGINEER: ENGINEER INFORMATION Smith SS11 Secan Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX- (954) 421 -1466 www.ssr - inc.com Firm Certification - EB- 0000857 Alfred Eequivel PE - 46863 Bruoe W. Peek PE - 36901 Donald Netinho PE-48464 Nelson R. Long PE - 62294 John E. Moulder PE - 33200 SSR JOB # 0632086.0 !. REVISIONS: PROJECT NAME: SMH - ADVANCE TOWER OFFICES - 2ND FLOOR PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 KEY PLAN COMM. NO. 40030.100 SCALE: DATE: OCTOBER 16,20W DRAWN: CHECKED: CADD FILE: DRAWING TITLE: LEGEND, SCHEDULES, & DRAWING INDEX SHEET NO.