06-2055-021PLUMBING - GENERAL NOTES:
1. ALL EXISTING WORK NOT SHOWN ON THESE DRAWINGS
( UNLESS NOTED OTHERWISE) SHALL REMAIN AS IS.
2- THE CONTRACTOR SHALL KEEP A SET OF MARKED UP DRAWINGS
AS THE JOB PROGRESSES. NO MAJOR CHANGE SHALL BE MADE
TO PLUMBING DESIGN /ENGINEERING UNLESS IT HAS BEEN
COORDINATED DRAWN, AND SUBMITTED FOR APPROVAL TO
THE ARCHITECT.
3. CONTRACTOR SHALL COORDINATE WITH ALL
DISCIPLINES INVOLVED SO AS TO AVOID ANY PIPE
ROUTING PROBLEMS.
4. WARRANTY /GUARANTEE
A.THE CONTRACTOR SHALL WARRANTY /GUARANTEE AND MAINTAIN THE STABILITY OF
WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE
PERIOD OF ONE YEAR.
B. DEFECTS OF ANY KIND DUE TO THE FAULTY WORK OR MATERIALS APPEARING
DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY
THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE
OWNER AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE
DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE
ORIGINAL DEFECT OR REPAIR THERETO.
PLUMBING - DEMOLITION NOTES:
1. EXISTING FIXTURES, EQUIPMENT, SERVICES, AND CONNECTIONS TO
REMAIN AS IS, WHICH ARE DAMAGED DURING CONSTRUCTION, SHALL BE
REWORKED OR REPLACED AS REOUI RED TO PROVIDE ORIGINAL
OPERATION.
2. PENETRATIONS OR OPENINGS FROM REMOVED PIPES THROUGH EXISTING
WALLS AND FLOORS SHALL BE SLEEVED AND /OR PATCHED TO MATCH THE
EXISTING STRUCTURE. SEE ARCHITECTURAL DRAWINGS FOR FINAL
FINISHES.
3. CONTRACTOR SHALL COORDINATE INTERRUPTION OF EXISTING SERVICES;
WITH OWNER, BEFORE CONSTRUCTION.
4. REPAIR /REPLACE EXISTING VALVES WHICH DO NOT HOLD WHEREVER NEW
PIPING IS CONNECTED TO EXISTING PIPING, AND THE EXISTING
VALVES ARE TO BE REUSED.
5. CONTRACTOR IS ADVISED THAT LOCATIONS SHOWN FOR EXISTING SERVICES
ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY LOCATIONS, MATERIALS
AND SIZES OF PLUMBING SERVICES PRIOR TO CONSTRUCTION. CONTRACTOR
SHALL BRING DISCREPANCIES BETWEEN THE NEW CONSTRUCTION DRAWINGS
AND THE EXISTING CONDITIONS TO THE ARCHITECT'S ATTENTION FOR
COORDINATION PRIOR TO CONSTRUCTION.
6. CONTRACTOR SHALL SUBMIT A COMPLETE LIST OF EQUIPMENT THAT
ARE TO BE REMOVED TO THE LOCAL OWNER'S REPRESENTATIVE.
ALL ITEMS THAT THE LOCAL OWNER'S REPRESENTATIVE WISHES TO
RETAIN SHALL BE PLACED IN STORAGE AND THE REMAINDER SHALL
BE REMOVED FROM THE SITE AND LEGALLY DISPOSED.
PLUMBING DRAIN SCHEDULE
SYMBOL DESCRIPTION
SYMBOL
—
WASTE
REMARKS
MANUFACTURER
MODEL
TYPE
FD -1
JAY R. SMITH
FLOOR DRAIN
*2005 -B
POLISHED E T NICKEL
3.
TRAP PRIMER
HILTI KWIK -BOLT, ZINC PLATED,
METAL EXPANSION ANCHOR.
ALL THREAD
HANGER ROD
'IPE HANGER. RING N;, ��J� \ \�•I 1 � •.
.T.T. GRINNELL FIG.69 .
PIPE HANGER "RING PIPE
I.T.T. GRINNELL FIG8260
PIPES 3 & SMALLER PIPES 41 & LARGER
'4VED.
CONCRETE INSERT
PIPING HANGER DETAIL
SCALE:
NONE
PLUMBING SPECIFICATIONS
REGULATORY REQUIREMENTS
A. NFPA 101: Life Safety Code (2003).
B. NFPA 991 Standard for Health Care Facilities (2002).
C. ANSI Handicapped Code-A117.1.
D. Florida Fire Marshall's Rules 69A -3.012 F.A.C. - (2004).
E. Florida Building Code - 2004
PLUMBING MATERIALS
PLUMBING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH FLORIDA
BUILDING CODE - PLUMBING 2004 AND ADA REQUIREMENTS.
WASTE AND VENT: NO HUB SERVICE WEIGHT CAST IRON ABOVE FLOOR WITH 'HUSKY'
CLAMPS FOR PIPING 2' AND LARGER AND COPPER TYPE 'M' HARD DRAWN COPPER
WITH WROUGHT FITTINGS, WITH 95/5 LEAD FREE SOLDER FOR PIPING UP TO 1 -1/2'
WATER: DOMESTIC COLD, HOT & HOT WATER RETURN PIPING SHALL BE TYPE 'L' HARD
DRAWN COPPER WITH WROUGHT FITTINGS, WITH 95/5 LEAD FREE SOLDERED
JOINTS PER FBC 2004. INSULATE HOT WATER PIPING USING In THICK FIBERGLASS
INSULATION HAVING A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE
DEVELOPMENT OF 50 OR LESS IN ACCORDANCE WITH ASTM E- 84,NPFA 225
AND UL 723. FOAMGLASS INSULATION SHALL BE USED WHERE PIPING
PENETRATES RATED WALLS. LABEL PIPING BY ADHESIVE LABELS (TO DENOTE
CONTENTS AND DIRECTION OF FLOW) ON PIPING AT NO MORE THAN 25 FOOT INTERVALS,
AT EACH VALVE AND AT EACH CHANGE IN DIRECTION. PROVIDE ARROWS AT EACH
LOCATION WHERE LABELED INDICATING DIRECTION OF FLOW. LABELING TO BE MINIMUM OF
2' HIGH LETTERS.
CONDENSATE PIPING: COPPER TYPE 'M' WITH WROUGHT COPPER FITTINGS LEAD FREE
,pLDERED JOINTS. CONDENSATE INSULATION: FLEXIBLE TUBULAR ELASTUMERIC
ARMAFLEX OR THERMACELL, 25/50 FIRE /SMOKE RATING, SEAL JOINTS WITH
INN UALTION MFGR. ADHESIVE LABEL AS INDICATED ABOVE.
PLUMBING LEGEND
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
—
COLD WATER
i
BALL VALVE
--
HOT WATER
CHECK VALVE
—SS—
SANITARY SEWER (UNDERGROUND)
MOUNTED
EXTERIOR CLEANOUT
—W—
WASTE LINE
P-4ETC
FIXTURE INDENTIFICATION
- -V --
VENT PIPE (ABOVE OR BELOW GROUND)
SIZE
CONNECTION TO EXISTING
—RWL—
RAIN WATER LEADER
TRAP
CAP ON LINE
— SW—
STORM WATER (UNDERGROUND)
GAS COCK
CLEANOUT (ABOVE CEILING)
0
PIPE TURNED UP
o
PIPE TURNED DOWN
.5GPM
—,�►—
BALANCING VALVE CIRCUIT SETTER W /CHECK
VALVE SET AT 0.5GPM
L
I
WATER
21,l DEFLECTOR
MIN• CENTERLINE
11 / OF TRAP P.D.J. FIXTURE UNIT
PRIMER SYMBOL RATING
A 1 -II
tqVACUUM BREAKER B 12_32 , .I
ASSEMBLY
CRITICAL LINE C 33-60
C. D 61 -113
.B. .L. LBOW 5/ FEMALE E 114 -154 TYPICAL WATER
DISTANCE TO TUBE F 155 -330 HAMMER ARRESTERS
BE DETERMINEIJ FITTING
BY INSTALLER
r TUB TUBING �FLAI
ffCENTER LINE
TE
FIN . FLOOR
FLOOR DRAIN
FLUSH VALVE TRAP PRIMER
P -3
ALE:N.T.S.
ry- — 2"
3rd
P -3 CO.
3� 3 �' 2nd
CO. W
2'
2"
11 /d 11/4
11/ P -2 14
ivy 120'1 2'
P -2
`r 2' P -1 J CO.
co.
FD -1 V 4
d
IITARY & DOMESTIC ISOMETRIC RISERS
:N.T.S.
PLUMBING FIXTURE SCHEDULE
L
DESCRIPTION
FIXTURE
FITTING
FLOOR
NEW CONSTRUCTION
CONNECT TO EXIST. AT THIS POINT
MOUNTED
C.W
H.W.
WASTE
REMARKS
MANUFACTURER
MODEL
TYPE
SIZE
MANUFACTURER
TYPE
SUPPLY
TRAP
FAUCET
SYMBOL
CARRIER
P -1
WATER (PUBLIC)
KINGSTON
K -4330
FLUSH VALVE
WALL HUNG
ELONGATED
BOWL
SLOAN ROYAL
* 111-1.6 YBYC
FLUSH VALVE
NA
INTEGRAL
NA
ZURN
1.
__
4@
K -4670C WHITE,
SEAT,MOUNT
C
1.5 GALLON
VITREOUS CHINA
Z1212
(HC) 18' A.F.F.
KOHLER (HC)
KINGSTON
WALL HUNG
5' BACKSPLASH
McGUIRE
•155WC GRID DRAIN
H -2165
*8872 1 4 P -TRAP
CHICAGO FAUCET
0895- 317FCCP
ZURN
1
1 1 /(
MOUNT
34' A.F.F.
P -2
LAVATORY
K -2005
CONCEALED ARM
21' X 18'
WITH PROWRAP
OFFSET FOR WHEEL
Z -1231
--
VITREOUS CHINA
4' FAUCET CTR
_
WRISTBLADE HANDLE
TO RIM
P -3
JUST - (STAFF)
*SL-ADA-
2019 -A -GR
SINGLE COMP
(S.S.) 18 GAUGE
14' X 16' X 61/¢
McGUIRE
GRID DRAIN
•151
H -2165
'8912
11/1 P -TRAP
CHICAGO FAUCET
NA
1
1 /� I
NA
S.S. SINK
SELF - RIMMING
786- GN2FCCP
GEN NOTE:
CONNECT TO EXISTING 4' SANITARY BELOW FLOOR,
1 COLD WATER AND 2' VENT ABOVE THE CEILING
IN THIS AREA.
O i OCOLD WATER XANDN2' 4' ENTNABOVE THE CEILINGRIN
THIS AREA.
3Q CONNECT TO NEAREST CONDENSATE RISER.
O CONTRACTOR SHALL FURNISH AND INSTALL 120V ELECTRIC OPERA ED
SOLENOID VALVE ON COLD WATER EQUAL TO 'ASC0* 8210G8 (I .to
BRASS BODY. SEE ELECTRICAL DWG 'S FOR MORE INFORMATION.
LEGEND
L
DESCRIPTION
rCONSTRUCTION
EXISTING TO REMAIN
I
NEW CONSTRUCTION
CONNECT TO EXIST. AT THIS POINT
PLUMBING DRAWING INDEX
SHEET
NO.
DESCRIPTION
P -2.1
LEGEND, SCHEDULES, DRAWING INDEX AND
2ND FLOOR NEW WORK PLAN - PHASE B - PLUMBING
I
i
2ND FLOOR PLAN - NEW WORK - PHASE B - PLUMBING -
0' 2' 4' 8' 16' 24'
BERMELM AJAMIL & PARTNERS, INC.
Archit utiEngineering Planning
Interior Design Landscape Architecture
2601 South Bayshore Drive 1 Oth Floor
1 1, Florida 33133
(305) 0 Fax (305) 860 -3700
MEP ENGIN INFORMATION
Sm th
Secan
Reid, Inc.
600 West Hillsboro, Suite 300
Deerfield Beach, FL 33441
(954) 421 -1260
FAX: (954) 421 -1466
www.ssr - inc.com
Firm Certification - F13,M00857
AI&ed Esquivel PE - 458W
Bruee W. Peek PE - 95901
Donald Netinho PE-48454
Nelson B. Long PE - 52294
John E. Moulder PE - 99200
SSR JOB # 0632086.0
4
LI
I;la'Ll•'iL�L`�
_ d'1
A _
PROJECT NAME:
SMH - ADVANCE TOWER OFFICES - 2ND F1,OOR
PROJECT ADDRESS:
7400 S.W. 62nd Ave.
South Miami, Florida 33143
KEY PLAN
"TOW**
COMM. NO. 4030.100
SCALE:
DATE:• NOVEMBER 9, 2
DRA A
CHEC '6
CADD FILE:
DRA G TITLE: •
2t& FLOOD PIMA
N W - t....
P SE R-1-op
PL " I N91
SHEET NO.