06-2055-014LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT LIGHTING F5 NUMBER DESIGNATES FIXTURE TYPE - SEE LIGHTING FIXTURE SCHEDULE SYSTEM F5 ALL FIXTURES IN THIS SPACE SHALL BE THE SAME TYPE INDICATED EXTENT OF CONDUITi Q ®SURFACE 3' -10' AFF TO CL OR RECESSED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) FIRE ALARM MANUAL PULL STATION - KEY OPERATED 3' -10' AFF TO CL ®SURFACE OR RECESSED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT FIXTURE (TYPE DETERMINES MOUNTING) 7' -0' AFF TO CL F� ®SURFACE VENDOR OR RECESSED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. FIXTURE (TYPE DETERMINES MOUNTING) FIRE ALARM CHIME VENDOR 04 0 SURFACE OR RECESSED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) ® ®® CIRCUIT FIXTURE (TYPE DETERMINES MOUNTING) ED TO EMERGENCY Q ® ® SURFACE OR RECESSED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. FIXTURE (TYPE DETERMINES MOUNTING) WP ® SURFACE OR SUSPENDED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) OH ® CIRCUIT. OR SUSPENDED FLUORESCENT CONNEC D TO EMERGENCY FIXTURE (TYPE DETERMINES MOUNTING) DS ❑ ® SURFACE OR SUSPENDED FLUORESCENT CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. FIXTURE (TYPE DETERMINES MOUNTING) OR Q WALL BRACKET FIXTURE ® SMOKE DETECTOR REMOTE INDICATOR CIRCUIT RACKET FIXTURE CONNECTED TO EMERGENCY rS_A11 SMOKE DETECTOR ALARM REMOTE INDICATOR /TEST SWITCH WALL BRACKET FIXTURE CONNECTED TO EMERGENCY CIRCUIT W/ BATT. BACKUP. ®+ EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED ON PLANS ® SPRINKLER SYSTEM FLOW SWITCH POLE MOUNTED LIGHT FIXTURE FRCP SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 3' -10' AFF TO CL SINGLE POLE SWITCH - RED TOGGLE 3' -10' AFF TO CL S2 DOUBLE POLE SWITCH - CENTER OFF 3' -10' AFF TO CL S3 THREE WAY SWITCH - IVORY TOGGLE 3' -10' AFF TO CL $T MOTOR RATED SWITCH WITH THERMAL OVERLOAD W SD DIMMER SWITCH 3' -10' AFF TO CL $IT INTERVAL TIMER SWITCH 3' -10' AFF TO CL POWER - RECECPTACLES 1' -6' AFF TO CL 120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) V -6' AFF TO CL 8' 120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) AS NOTED OR SEE SPECS 11-61 AFF TO CL 120V. OUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) 1' -6' AFF TO CL AS NOTED SEE SPECS. 120V. OUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) AS NOTED OR SEE SPECS 8— SPECIAL RECEPTACLE (TYPE AS NOTED) AS NOTED OR SEE SPECS �- 120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT) AS NOTED OR SEE SPECS Q- 120V. GFI RECEPTACLE V -6' AFF TO CL JUNCTION BOX GB GROUNDING COLLECTION BUS HOMERUN CONDUIT (QUANTITY OF ARROWS DETERMINES NUMBER OF CIRCUITS) SOUND SYSTEM Ps CEILING PAGING SPEAKER CEILING MTD. CAPPED CONDUIT NON- FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) E=h FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) ®+ COMBINATION MOTOR STARTER ® FACTORY WIRED CONTROLLER OR EQUIPMENT ,1 MOTOR CONNECTION (NUMER INSIDE SYMBOL INDICATES HP) UNIT HEATER CONNECTION DUCT HEATER CONNECTION = PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED FG—A GENERATOR ANNUNCIATOR PANEL Q PULL BOX ® EMERGENCY LIGHTING TRANSFER RELAY LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT FIRE ALARM ,F FIREFIGHTER'S TELEPHONE JACK SYSTEM AFF FIRE ALARM VISUAL STATION - LIGHT ONLY EXTENT OF CONDUITi Q FIRE ALARM MANUAL PULL STATION 3' -10' AFF TO CL ❑ K FIRE ALARM MANUAL PULL STATION - KEY OPERATED 3' -10' AFF TO CL 00 FIRE ALARM 10' BELL 7' -0' AFF TO CL F� FIRE ALARM CHIME WITH LIGHT VENDOR ® FIRE ALARM CHIME VENDOR 04 FIRE ALARM HORN FIRE ALARM ® FIRE ALARM SPEAKER THROUGHOUT Q MAGNETIC DOOR HOLDER 1' -0' BELOW CLG WP FIRE ALARM SMOKE DETECTOR ('E' INDICATES ELEVATOR RECALL) CEILING OH HEAT DETECTOR DS ❑ DUCT SMOKE DETECTOR - SUPPLY DUCT OR DUCT SMOKE DETECTOR - RETURN DUCT ® SMOKE DETECTOR REMOTE INDICATOR rS_A11 SMOKE DETECTOR ALARM REMOTE INDICATOR /TEST SWITCH SPRINKLER SYSTEM VALVE STATUS SWITCH ® SPRINKLER SYSTEM FLOW SWITCH FRCP FIRE ALARM CONTROL PANEL FAAN FIRE ALARM ANNUNCIATOR PANEL ® FIRE ALARM RELAY �z FIRE ALARM ZONE ADDRESSABLE MODULE NOTESi O EC= ELECTRICAL CONTRACTOR O2 NOT USED Q3 STUB -UP TO ABOVE ACCESSIBLE CEILING SPACE IN CORRIDOR, TERMINATE WITH PLASTIC BUSHING. Q VENDOR CONTRACTED DIRECTLY BY OWNER. TELEPHONE/DATA TELEPHONE OUTLET WITH PLATE V -6' AFF TO CL W WALL TELEPHONE OUTLET WITH PLATE 41-61 AFF TO CL �- TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. COMBINATION DATA /TELEPHONE OUTLET WITH PLATE 1' -6' AFF TO CL a. COMBINATION DATA /TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. Q DATA OUTLET WITH PLATE 11-61 AFF TO CL Q- DATA OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. ® TELEPHONE SWITCHBOARD CONSOLE CABLE /MAN SYSTEM a MATV OUTLET FOR WALL MOUNTED TV (ANTENNA,& REMOTE CONTROL SEE MANUFACTURERS DETAIL) 88'AFF MISCELLANEOUS CONDUIT CONCEALER CONDUIT BELOW GRADE - ON SITE HOMERUN CONDUIT (QUANTITY OF ARROWS DETERMINES NUMBER OF CIRCUITS) - - -- EXPOSED CONDUIT ON WALL OR CEILING CAPPED CONDUIT NON- FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) E=h FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) ®+ COMBINATION MOTOR STARTER ® FACTORY WIRED CONTROLLER OR EQUIPMENT ,1 MOTOR CONNECTION (NUMER INSIDE SYMBOL INDICATES HP) UNIT HEATER CONNECTION DUCT HEATER CONNECTION = PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED FG—A GENERATOR ANNUNCIATOR PANEL Q PULL BOX ® EMERGENCY LIGHTING TRANSFER RELAY LEGEND SYMBOL DESCRIPTION' - _ _ _ F*OUN ,, ING HEIGHT ABBREVIATIONS ABC ABOVE COUNTER SYSTEM AFF ABOVE FINISHED FLOOR EXTENT OF CONDUITi AFG ABOVE FINISHED GRADE NOTESe C RED - EMERGENCY POWER VENDOR CLG CEILING ' VENDOR FBO FURNISHED BY OTHERS VENDOR IG ISOLATED GROUND VENDOR S SAFETY TYPE FIRE ALARM SMH SPECIAL MOUNTING HEIGHT - AS NOTED OR SEE SPECS THROUGHOUT TV TELEVISION WP WEATHERPROOF BID NOTE IT SHALL BE THE RESPONSIBILITY OF THE CONSTRUCTION MANAGER (CM), GENERAL CONTRACTOR (GC), AND THE SUB - CONTRACTORS (SC) TO STUDY ALL THE DRAWINGS AND DETAILS SO THAT THE INSTALLATION OF ALL NEW WORK CAN BE FULLY COORDINATED. THE CM, GC, AND SC SHALL VISIT THE SITE, INCLUDING DOING AN ABOVE CEILING INSPECTION, DURING BIDDING TO SATISFY HIMSELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND /OR SITE CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IN WRITING PRIOR TO BID DUE DATE. FAILURE TO DO SO WILL NOT BE ALLOWED ON A BASIS FOR ADDITIONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWINGS. SYSTEMS RESPONSIBILTY SCHEDULE SYSTEM INTERIOR CABLE FURNISHED BYo INTERIOR CABLE INSTALLED BYt EXTENT OF CONDUITi EOUIPMENT FURNISHED BYi EQUIPMENT INSTALLED BYe NOTESe TELEPHONE /DATA VENDOR VENDOR Q VENDOR VENDOR - POWER & SYSTEMS COMPUTER VENDOR VENDOR 3 VENDOR VENDOR 4 FIRE ALARM EC EC THROUGHOUT EC EC NOTESi O EC= ELECTRICAL CONTRACTOR O2 NOT USED Q3 STUB -UP TO ABOVE ACCESSIBLE CEILING SPACE IN CORRIDOR, TERMINATE WITH PLASTIC BUSHING. Q VENDOR CONTRACTED DIRECTLY BY OWNER. BID NOTE IT SHALL BE THE RESPONSIBILITY OF THE CONSTRUCTION MANAGER (CM), GENERAL CONTRACTOR (GC), AND THE SUB - CONTRACTORS (SC) TO STUDY ALL THE DRAWINGS AND DETAILS SO THAT THE INSTALLATION OF ALL NEW WORK CAN BE FULLY COORDINATED. THE CM, GC, AND SC SHALL VISIT THE SITE, INCLUDING DOING AN ABOVE CEILING INSPECTION, DURING BIDDING TO SATISFY HIMSELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND /OR SITE CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IN WRITING PRIOR TO BID DUE DATE. FAILURE TO DO SO WILL NOT BE ALLOWED ON A BASIS FOR ADDITIONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWINGS. • AJAMIL & PARTNERS, INC. Arc hitecture Engineering Planning Interic ir Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (3051859-2050 Fax (305) 860 -3700 EER: INFORMATION Sm r Sec an Reid, Inc. West Hillsboro, Suite 300 :er6eld Beach, FL 33441 (954) 421 -1260 FAX- (954) 421 -1466 www.ssr - inc.com rtn Certification - EB -000W7 Alff ed Ewpgvel PE - 46889 Bruce W. Peet PE - 56901 Donald NoUnho PE - 48464 Nelson B. Img PE - 52284 John E. Moulder PE - 35200 SSR JOB # 0642086.0 No. ,4556 TAI ; PRO.IECT NAME: SMH - ADVANCE TOWER OFFICES - 2ND FLOOR PR ECT ADDRESS: 7400 S 62nd Ave. South '. Florida 33143 PLAN . NO. 40030.100 DATE: NOVEMBER 9. 2006 DRAWN: CHE KED: CAD FILE: DRA NG TITLE: LE END, SCHEDULES & DRAWING INDEX NO. E -0.1 ELECTRICAL DRAWING INDEX SHEET NO. DESCRIPTION E -0.1 LEGEND, SCHEDULES, AND DRAWING INDEX - ELECTRICAL E -1.1 2ND FLOOR PLAN - DEMOLITION - PHASE B - ELECTRICAL E -2.1 2ND FLOOR PLAN - NEW WORK - PHASE B - LIGHTING E -3.1 2ND FLOOR PLAN - NEW WORK - PHASE B - POWER & SYSTEMS E -4.1 PARTIAL POWER RISER DIAGRAM & PANEL SCHEDULES E -5.1 ELECTRICAL SPECIFICATIONS • AJAMIL & PARTNERS, INC. Arc hitecture Engineering Planning Interic ir Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (3051859-2050 Fax (305) 860 -3700 EER: INFORMATION Sm r Sec an Reid, Inc. West Hillsboro, Suite 300 :er6eld Beach, FL 33441 (954) 421 -1260 FAX- (954) 421 -1466 www.ssr - inc.com rtn Certification - EB -000W7 Alff ed Ewpgvel PE - 46889 Bruce W. Peet PE - 56901 Donald NoUnho PE - 48464 Nelson B. Img PE - 52284 John E. Moulder PE - 35200 SSR JOB # 0642086.0 No. ,4556 TAI ; PRO.IECT NAME: SMH - ADVANCE TOWER OFFICES - 2ND FLOOR PR ECT ADDRESS: 7400 S 62nd Ave. South '. Florida 33143 PLAN . NO. 40030.100 DATE: NOVEMBER 9. 2006 DRAWN: CHE KED: CAD FILE: DRA NG TITLE: LE END, SCHEDULES & DRAWING INDEX NO. E -0.1