06-1457R-0021. ALL MATERIAL AND WORKMANSHIP SHALL BE DONE IN STRICT
ACCORDANCE TO THE LATEST EDITION OF THE FLORIDA
BUILDING CODE AND THE LANDLORD'S MECHANICAL DESIGN
CRITERIA.
2. ALL SANITARY SHALL BE CAST IRON AND SLOPED A MINIMUM
OF 1/8 INCH PER FOOT FOR 3" AND LARGER & 1 /4 " /FT
FOR 2" & SMALLER.
3. ALL WATER LINES SHALL BE COPPER, GAS LINE SHALL BE GALV.
STEEL.
4. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE
HIMSELF WITH THE LOCATION OF ALL EXISTING UTILITIES,
STUB OUTS, PIPING EQUIPMENT, ETC., AND /OR ANY CONDITION
THAT MAY AFFECT HIS WORK. ALL THE NECESSARY REROUTING,
AND /OR REMOVAL OF EXISTING PIPING EQUIPMENT, ETC. SHALL
BE INCLUDED IN THE SCOPE OF WORK INCLUDING REMOVAL OF
LINES IN THE WAY OF OTHER TRADES' NEW INSTALLATION.
5. PROVIDE SHUT -OFF VALVES AT EACH FIXTURE UNIT AND EACH
FIXTURE GROUP.
6. ALL SYSTEMS SHOWN ON THE DRAWINGS ARE DIAGRAMATICAL,
CONTRACTOR SHALL PROVIDE ALL VALVES, FITTINGS AND
MATERIAL FOR A COMPLETE INSTALLATION OF ALL SYSTEMS.
7. CONTRACTOR TO SECURE EXACT LOCATION OF UTILITIES
CONNECTIONS FROM BUILDING MANAGEMENT AND MAKE ANY
NECESSARY DEVIATION FROM THESE PLANS TO OBTAIN A FINAL
CONNECTION WITHOUT EXTRA COST TO OWNER.
8. CONTRACTOR SHALL OBTAIN APPROVAL OF SHOP DRAWINGS
SUBMITTALS OF MATERIAL AND EQUIPMENT TO SUBSTITUTE BASIS
OF DESIGN EQUIPMENT AND MATERIALS NOTED ON THESE
DRAWINGS TEN DAYS PRIOR TO BID DATE. AFTER THIS DATE
NO SUBSTITUTIONS SHALL BE ADMITTED.
9. CONTRACTOR SHALL VERIFY ALL EQUIPMENT, AND PIPING TO
WORK AND FIT PROPERLY WITH ALL OTHER TRADES AND ASSURE
THAT THESE ITEMS DO NOT CONFLICT WITH ELECTRICAL FIXTURE
AND AC DUCTWORK LOCATIONS.
10. LOCATION AND SIZE OF ALL SLEEVES THROUGH STRUCTURAL
ELEMENTS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL
PRIOR TO EXECUTION.
11. CONTRACTOR SHALL FURNISH THE OWNER WITH ALL OPERATING
MANUALS AND MAINTENANCE INSTRUCTIONS FOR EQUIPMENT
INSTALLED . MANUALS SHALL BE BOUNDED IN THREE RING LOOSE
LEAVE BINDERS AND INDEX BY PRODUCT TYPE. ALSO A SECTION
WITHIN THE MANUAL SHALL BE INDEX WITH NAME, TELEPHONE
NUMBER AND ADDRESS OF ALL LOCAL SUPPLIERS OF ALL
MATERIAL AND EQUIPMENT INSTALLED TOGETHER WITH NAME,
TELEPHONE AND ADDRESS OF ALL CONTRACTORS OF THE PROJECT.
PROVIDE 3 SET TO BE APPROVED BY ENGINEER.
12. CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE
CONTRACT TO BE FREE FROM THE DEFECTIVE WORKMANSHIP
AND MATERIALS, USUAL WEAR EXPECTED, AND SHOULD ANY SUCH
DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER
ACCEPTANCE OF THE BUILDING BY THE OWNER , THIS
CONTRACTOR SHALL REPAIR AND /OR REPLACE ANY DEFECTIVE
ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE
ITEMS, AT NO EXPENSE WHATSOEVER TO THE OWNER.
13. CONTRACTOR SHALL PROVIDE 6 SETS OF SHOP DRAWINGS
SUBMITTALS FOR ALL MATERIAL AND EQUIPMENT TO BE USED IN
THESE PROJECT FOR APPROVAL BY ARCHITECT /ENGINEER.
14. CONTRACTOR SHALL MAINTAIN A SET OF REPRODUCIBLE
DRAWINGS SHOWING AS BUILT CONDITIONS AS THEY OCCUR. A
COMPLETE SET OF AS -BUILT REPRODUCIBLE DRAWINGS SHALL BE
SUBMITTED BY THE CONTRACTOR TO THE ARCHITECT /ENGINEER
PRIOR TO FINAL ACCEPTANCE OF INSTALLATION. THESE
DRAWINGS SHALL HAVE ALL INSTALLATIONS REFERENCED BY
DIMMENSIONS TO A SET REFERENCED POINT OR POINTS.
15. EXPOSED OR WITHIN ACCESIBLE CEILING PIPING SHALL BE
COLOR CODED BY 2" PAINT STRIP AROUND PIPE AT 10' APART
AND AT EACH SLAB OR BEAM PENETRATION AS FOLLOW:
COLD WATER = KELLY GREEN
HOT WATER = MAGENTA
VENT LINE = LIGHT BLUE
SANITARY LINE = BROWN
GAS LINE = ORANGE
16. ALL VALVES SHALL BE TAGGED WITH 2" BRASS DISKS AND
SUBMIT CHART SHOWING LOCATION, SIZE AND SERVICE IN
MAINTENANCE MANUALS DESCRIBED ABOVE.
17. CONTRACTOR SHALL PAY ALL FEES, INSPECTION
AND CONNECTION CHARGES REQUIRED.
18. CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND
DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND
INSTALLATION OF MATERIALS AND EQUIPMENT.
19. COORDINATE WORK WITH OTHER TRADES.
20. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A
DI- ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH
TYPES OF PIPES.
21. THE WORD "PROVIDE" MEANS FURNISH AND INSTALL.
22. CONTRACTOR TO RETAIN FIRE SPRINKLER CONTRACTOR.
TO RELOCATED EXISTING SPRINKLER HEADS AND INSTALL
ADDITIONAL HEADS TO FIT NEW SPACE LAYOUT IN ACCORDANCE
TO LOCAL CODE.
23. CONTRATOR SHALL REVIEW AND UNDERSTAND THE CONTENT OF
THESE DRAWINGS, VISIT THE SITE AND THROUGHLY REVIEW
EXISTING CONDITIONS PRIOR To BID. NO ALLOWANCE WILL BE
MADE FOR ANY EXISTING CONDITION THE CONTRACTOR DID NOT
BECOME AWARE OF OR UNDERSTOOD.
FIXTURE CONNECTION SCHEDULE
MARK
DESCRIPTION
CW
IN
HW
IN
WASTE
IN
INDIRECT
IN WASTE
GAS
IN
�j
DOUBLE CONVECTION OVEN, GAS
-
-
-
-
3/4"
OZ
(2) STEAMERS - STACKED
3/4"
-
1-1/2"
-
(2)1/2"
O3
GAS CHAR - BROILER - 8 BURNERS
-
-
-
-
3/4"
O
6 BURN.RANGE /OVEN AND GRID.
-
-
-
-
3/4"
0
GAS FRYER
-
-
1 -1/4"
-
3/4"
10
HAND SINK
1/2"
1/2"
1 -1/2"
-
-
13
3 COMP. SINK W /DRAIN BOARD
1/2"
1/2"
1/4"
-
-
21
SINK
1/2"
1/2"
1 -1/2"
-
-
23
ICE CUBE MACHINE
3/8"
-
1/2"
-
-
1
3"GW FROM
1 st FLOOR
A3
LJ
3"
nn
M
2WAY
:X PUMP
FCO
ROLLER.
o
ae
09
C2
GREASE TRAP
JOSAM 60106 -50
DRAW -OFF ON FLOOR
I
co
0
STAND.
,SCHARGE
FLOOR MOUNTED
fARY LINE
(DUAL) SEWAGE
LING BELOW 1st
SUMP PUMP
R SLAB.
LITTLE GIANT
�
MODEL 9E -CIM
_
BASIN ASSEMBLY
03
BS3036CD2V2D
m
4N. LINE
ELOW 1st
B.
E
E ---- -- E --1?
D) PARTIAL PLUMBING BASEMENT PLAN I/4"
� 44 /
GAS SIZING SCHEDULE
TABLE 402(1) FUEL GAS CODE
TYPE GAS: NATURAL
O2 62,000 BTUH MAX. LENGTH LINE: 30 F.T.-
raj 120,000 BTUHI TOTAL BTUH INPUT: 02I&DQ
u
062,000 BTUH
u O3 116,000 BTUH
3/41"
c
1" u
O4 156,000 BTUH
1 -1/4" O 105,000 BTUH
C �
1 -1/4"
GAS RISER.
NTS
JOSAM 58510
CLEAN -OUT TEE
WITH PLUG
CHASE WAILL
ffli
Hl
EH
PVC TO C.I. COUPLING;
04 A
1-
PVC RISER
PVC TO C.I. COUPLING
JOSAM 58600
~- ACCESS COVER
MAX 18 " FROM
FLOOR
FLOOR SLAB
WALL CLEAN -OUT DETAIL.
NTS
GRADE CLEAN -OUT
JOSAM 56040
COUPLING
D
SEWER LINE
in VALVE
CONNECTED TO KITCHEN
HOOD FIRE SUPPRESSION
SYSTEM
2- W A Y
CLEArimOUT TO GRADE DETAIL
N TS
10
• • •
, ,
,
21 �/ 1/2„ • • •
21 /•••� �' , •
1/2' �� i
1/2' f1 10 1 /2"
�� CHRONOMITE
1/2" MODEL No. 1/2" / 1/2"
S -901 >0000*
` 1/2" / CHRONOMITE
1/2's ` 1�
MODEL No.
S -901
1/2" 0' ("`� 3/4"
1 /2"
MODEL WATER RISER
MODEL Noo. .
S -901
N TS
NOTE: PROVIDE BACKFLOW PREVENTER
AT WATER SERVICES.
its
3 "FFD
3 "(3 FU)
3"FFD
04o, 3 "(10 FU) "
" 2
"(3 FU �� (2 A& V� 3 "FD
i
� i 1
2" ��� 13 "EXIST. 2��i: O
� . 10
22 VENT. � �
CONNECT AT TOP `l�l � � WCO
OF PIPE. 3 "(2 FU)
i
2 " C�`� 3 "(2 FU)
I
" 2� 10 "mot; 2„ 3 "(2 FU) 2" 22
2 DISCHARGE 1 /`l
F SANITARY LINE / 3 " FD
RUNNING BELOW 1st [?0 (�`� ��
FLOOR SLAB. 13 1 3 "(10 FU)
EXIST. 6 0SAN. LINE F 3 "(2 FU)
RUNNING BELOW 1st \ , 3 "(3 FU)
FLOOR SLAB.
�2" �� 3 "(2 FU)
2" "(5 FU) ('!✓ 3 F
21'
3"
3"
I
N TS
r � a
D) PLUMBING FLOOR PLAN
1/411
LEGEND
(DUAL) SEWAGE
SUMP PUMP
LITTLE GIANT
MODEL 9E -CIM
BASIN ASSEMBLY
B93036CD2V20
GREASE TRAP
JOSAM 60106 -50
DRAW -OFF ON FLOOR
STAND.
NEW SANITARY LINE
--- - - - - -- VENT LINE
--E - - E — EXIST. VENT LINE
COLD WATER
HOT WATER LINE
GW GREASE WASTE LINE
G GAS LINE
�— GATE VALVE
INDIRECT LINE
Co CLEANOUT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FFD FUNNEL FLOOR DRAIN
FU FIXTURE UNIT
NTS NOT TO SCALE
WCO WALL CLEANOUT
O EQUIPMENT NUMBER,."",t`t
Fil
WATER HAMMER AkROTOR ;<
+,
At
12 -05 -07 GENERAL REV.
10 -20 -06 BLDG. DEPT. COMM.
z
W
ae
W
s
0
W
ac
tp
M 1�
M
CO N
a- 1�
off Mf
�
o
ae
09
C2
o
<
to
W
I
co
0
�`
s
ce
G Lai
N
H
�
a L
v
W
a
�
L A
_
� o
03
b ac
ac
v < a
<
V
z
ll
W
p L
m
£ o
ae
>i d'
<
F— W U.
z
LO
Q
MR
Q
<
to
W
I
co
0
�`
s
�
��11
'may
G Lai
N
H
p
o
�
7 f--
U
Q
z
L_ W
J=
7 f--
j;z
=Um
ll
?(s)�
m
L
>i d'
I
(`n
7
F
O �-
-�
O Q Q
LL
u
� �_5
>
Ez°
�L
><>
C)
<9
L9
v
tu— Wtu—
zzz
O
J
z
CV Q,/ CV
LU
Z
D
CVO N
uti-u
tL