06-1457-008GRILLE SCHEDULE
MANUFACTURER
AIR -GUIDE
CD
CEILING DIFFUSER
FIRE DAMPERS
MODEL CB -1
SMOKE DAMPERS-
OUTSIDE AIR LOUVER
OAL
WITH INSECT SCREEN
FIRE -RATED FLOOR /
MODEL OL4FK
NOTES : 1- EXTRUDED ALUMINUM CONSTRUCTION.
2- FINISH : BAKED -OFF WHITE ENAMEL
HVAC CHECKLIST
HVAC DESIGN REQUIRES
ITCHEN AREA ONLY
DUCT SMOKE DETECTORS
YES
FIRE DAMPERS
NO
SMOKE DAMPERS-
NO
FIRE RATED ENCLOSURE
NO
FIRE -RATED FLOOR /
NO
CEILING ASSEMBLY
NO
FIRE STOPPING-
NO
SMOKE CONTROL
NO
AC GENERAL NOTES
1. SCOPE OF WORK:
A. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS AND
LABOR FOR A COMPLETE HVAC INSTALLATION IN ACCORDANCE
TO THESE DIAGRAMATICAL DRAWINGS.
B. MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE TO THE
LATEST EDITION OF THE FLORIDA BULIDING CODE .
C. CONTRACTOR SHALL BASE HIS BID AFTER FAMILIARIZING
HIMSELF WITH ALL EXISTING ASBUILT CONDITIONS.
2. CONTRACTOR SHALL VERIFY ALL EQUIPMENT, DUCTWORK,
DIFFUSERS AND GRILLES TO WORK AND FIT PROPERLY WITH ALL
OTHER TRADES AND ASSURE THAT THESE ITEMS DO NOT CONFLICT
WITH ELECTRICAL FIXTURE LOCATIONS.
3. VERIFY EXACT ROUTING OF DUCTWORK AND CONDENSATE DRAINS
WITH STRUCTURAL ELEMENTS. LOCATION AND SIZE OF ALL
SLEEVES THROUGH STRUCTURAL ELEMENTS SHALL BE SUBMITTED TO
ARCHITECT FOR APPROVAL PRIOR TO EXECUTION.
4. CONTRACTOR SHALL RETAIN AN INDEPENDENT TEST AND BALANCE
CONTRACTOR TO TEST AND BALANCE ALL THE HVAC SYSTEMS,
AND ADJUST ALL CONTROLS AND EQUIPMENT FOR PROPER
OPERATION. TEST AND BALANCE CONTRACTOR SHALL SUBMIT
3 SETS OF TEST AND BALANCE REPORT FOR ENGINEER'S
APPROVAL.
5. COORDINATE EXACT LOCA11ON OF ALL SUPPLY AND RETURN AIR
DEVICES WITH LIGHT FIXTURE LOCATIONS.
6. EQUIPMENT SHALL HAVE CAPACITIES REQUIRED TO OBTAIN A
SUITABLE OPERATING BALANCE BETWEEN ASSOCIATED ITEMS OF
EQUIPMENT. ALL DAMPER & CONTROLS SHALL BE ADJUSTED TO
OBTATIN THE REQUIRED CAPACITIES UNDER ACTUAL OPERATING
CONDITIONS OF EACH SYSTEMS AS INSTALLED. OPERATING POWER
REQUIREMENTS FOR EACH ITEM OF EQUIPMENT SHALL NOT EXCEED
THE RATED MOTOR HORSEPOWER.
7. CONSTRUCT A/C DUCTWORK FROM LOW PRESS. GALV SHEETMETAL
PER SMACNA'S LOW PRESSURE DUCT MANUAL , WITH R -6
INTERNAL LINING. VENTILATION DUCTWORK WITHOUT INSULATION.
SEAL AND INSTALL PER LATEST SMACNA MANUAL.
RECOMMENDATIONS. SIZES NOTED ARE CLEAR INSIDE
DIMENSIONS. PROVIDE AIR VOLUME EXTRACTORS, SPUTTER
DAMPERS OR ADJUSTABLE TURNING VANES AT ALL BRANCH TAKE-
OFFS AS REQUIRED FOR PROPER AIR BALANCING.
8. GREASE EXHAUST DUCTWORK SHALL BE 16. GA. SEAMLESS
CARBON. STEEL DUCTWORK WITH LIQUID -TIGHT EXTERNAL WELD.
KITCHEN HOOD SHALL BE 18 GA. GALV. STEEL WITH LIQUID -TIGHT
EXTERNAL WELD AS PER NFPA 96 SPECIFICATIONS.
9. AIR DISTRIBUTION DEVICES SHALL BE CONSTRUCTED OF
ALUMINUM, AS MANUFACTURED BY PRICE OR EQUAL APPROVED
AS SHCWN ON GRILLE SCHEDULE.
10. AC UNITS TO BE AS SCHEDULED,OR APPROVED EQUAL,
COMPLETE FACTORY ASSEMBLED,
11. COORDINATE ALL WORK WITH OTHER TRADES INVOLVED. THIS
INCLUDES WALL AND ROOF PENETRATIONS AND REQUIRED
ELECTIRCAL SERVICE AND CONTROL WIRING. PLUMBER IS TO
PROVIDE. CONDENSATE TRAP SEAL, PIPE DRAIN TO A LOCATION
AS SHCWN.
12. THERMOSTAT SHALL HAVE A MAXIMUM HEATING MODE TEMPERATURE
SETTING OF 78 F AND A MINIMUM COOLING MODE TEMPERATURE
SETTING OF 70 F. IT SHALL BE ADJUSTABLE TO PROVIDE A
TEMPERATURE RANGE OF UP TO 1OF BETWEEN FULL HEATING AND
FULL CDOLING. HEATING AND COOLING TO BE NON- CONCURRENT.
THERMOSTAT TO HAVE REQUIRED STAGES OF COOLING AND HEATING
FOR COMPATIBILITY WITH AIR CONDITIONING EQUIPMENT.
PROVIDE KEY - OPERATED TAMPER PROOF BOX.
AIR BALANCE
SCHEDULE
ITCHEN AREA ONLY
48: Wide or grater
4 ft
NEGATIVE PRESSURE
6ft
and less than 48"
EF -1 HOOD FAN ; 6000
CFM (- )
24
POSITIVE PRESSURE :
6ft
& 48" and greater
SF -1 MAKE -UP FAN :
5400 CFM (
+ )
AC -UNIT OUTDOOR AIR :
400 CFM (
+ )
TOTAL :
5800 CFM (
+ )
BALANCE :(+) 5800 ( -)
6000 = 200
CFM ( -) KITCHEN NEG. PRESSURE
S a b a
HOOD
:a,&.
13. PROVIDE NEW FILTERS FOR ALL AIR CONDITIONING AND
VENTILATING EQUIPMENT BEFORE STARTING THENM.THESE FILTERS
MUST ALSO BE REPLACED PRIOR TO FINAL ACCLEPTANCE BY OWNER.
14. CONTRACTOR SHALL FURNISH THE OWNER WITH I ALL OPERATING
MANUALS AND MAINTENANCE INSTRUCTIONS FORK EQUIPMENT
INSTALLED . MANUALS SHALL BE BOUNDED IN TTHREE RING LOOSE
LEAVE BINDERS AND INDEX BY PRODUCT TYPE. ALSO A SECTION
WITHIN THE MANUAL SHALL BE INDEX WITH NAWE, TELEPHONE
NUMBER AND ADDRESS OF ALL LOCAL SUPPLIEFRS OF ALL MATERIAL
AND EQUIPMENT INSTALLED TOGETHER WITH NAME, TELEPHONE AND
ADDRESS OF ALL CONTRACTORS OF THE PROJECT. PROVIDE 3 SET
TO BE APPROVED BY ENGINEER.
15. CONTRACTOR SHALL GUARANTEE ALL WORK INSTTALLED UNDER THE
CONTRACT TO BE FREE FROM THE DEFECTOVE WORKMANSHIP
AND MATERIALS, USUAL WEAR EXPECTED, AND SHOULD ANY SUCH
DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER
ACCEPTANCE OF THE BUILDING BY THE OWNER , THIS
CONTRACTOR SHALL REPAIR AND /OR REPLACE ANY DEFECTIVE
ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE
ITEMS, AT NO EXPENSE WHATSOEVER TO THE OWNER.
16. CONTRACTOR SHALL PROVIDE 6 SETS OF SHOP DRAWINGS SUBMITTALS
FOR ALL MATERIALS, EQUIPMENT AND LAYOUTS TO BE USED
IN THIS PROJECT FOR APPROVAL BY ARCH ITECIT /EN GIN EER.
SHOP DRAWINGS SHALL INCLUDE ALL MATERIALS AND DUCTWORK AND
PIPING LAYOUTS , COORDINATED WITH ALL RESF;PECTIVE TRADES.
SHOP DRAWINGS SHALL BE SUBMITTED AND APPPROVAL OBTAINED
PRIOR TO EXECUTION OF ANY WORK IN FIELD.
17. CONTRACTOR SHALL MAINTAIN A SET OF REPRODDUCIBLE SEPIA
DRAWINGS SHOWING AS BUILT CONDITIONS AS TTHEY OCCUR. A
COMPLETE SET OF AS -BUILT REPRODUCIBLE DRRAWINGS SHALL BE
SUBMITTED BY THE CONTRACTOR TO THE ARCH IITECT /ENGINEER
PRIOR TO FINAL ACCEPTANCE OF INSTALLATIONI. THESE
DRAWINGS SHALL HAVE ALL INSTALLATIONS REFFERENCED BY
DIMMENSIONS TO A SET REFERENCED POINT OR? POINTS,
18. IDENTIFY EACH EQUIPMENT AS PER DRAWINGS WITH UNIT NUMBER
PAINTED ON EQUIPMENT WITH 4" TALL LETTERSi AND NUMBERS.
19. ALL CHILLED WATER LINES SHALL BE COPPER TYPE K OR
BLACK STEEL PIPE SCHED.40 PIPE WITH WELDED JOINTS.
INSULATED WITH RIGID FOAMGLASS BOARD ASTFMC 612 WITH VAPOR
RETARDANT JACKET . INSULATION SHALL BE 11-1/2" THICK.
20. PROVIDE A TEST & BALANCE REPORT ON ALL EQUIPMENT , CHILLED WATER
& AIR DISTRIBUTION UNITS DETAILING SYSTEM PERFORMANCE INCLUDING
AMPS,BHP, GPM, CFM, S.P., E.S.P. , ETC.
TO BE PERFORMED BY A TEST & BALANCE CONTRACTOR.
21. VISIT THE SITE AND COORDINATE ALL NEW WORRK WITH EXISTING
FIELD CONDITIONS INCLUDING EXISTING SMOKE I REMOVAL SYSTEM DUCTWORK.
PROVIDE ALL REQUIRED DUCT OFFSETS AS PARRT OF THIS BID.
22. THE WORD "PROVIDE" MEANS SUPPLY AND INSiTALL.
23. ELECTRONIC FILES - SUBMITTAL PROCEDURES:
A. GENERAL: IF REQUESTED BY OWNER OR CONTRACTOR, ELECTRONIC
COPIES OF CAD FILES OF THE CONTRACTT DRAWINGS WILL BE
PROVIDED BY ENGINEER FOR CONTRACTO)R'S USE IN PREPARING SUBMITTALS.
A STIPULATED SUM WILL BE CHARGED T(0 THE REQUESTING PARTY FOR
THIS SERVICE.
B. THE FOLLOWING CHARGES WILL APPLY FCOR PROVIDING
ELECTRONIC FILES:
1. $50.00 PER ELECTRONIC DRAWING FILLE PREPARED
2. $350.00 PER ORDER FOR ADMINISTRATIVE PROCESS.
i•!• a•a • - -.
_ _ m
• a
2X2 FLANGE ON
2X2 ANGLES WITH l
5/8" BOLTS ,NUTS
WASHERS
TOTAL OF 4
2X2 FLANGE FROM -
3/8' THREADED RODS
NUTS, WASHERS
ON ONE INCH RUBBER
GASKETS
TOTAL: 2 FLANGES
4 RODS & GASKETS
�-- MOTOR & DRIVE OUT OF
AIR STREAM
IN -LINE FAN
( 4 )- 1" SPRING ISOLATORS
IN -LINE FAN MOUNTING DETAIL
NITS
STANDARD 3" WIDE HANGERS
Hanget extension to be the sum
of the distances between the hangin
wires and the duct size, ID (Smacna�
Maximum Hanger
Duct size, Inches
Spacing
48: Wide or grater
4 ft
Less tho 48" wide
6ft
and less than 48"
Profile
deep
24
Width between 28"
6ft
& 48" and greater
3" X 2"
than 16" deep
f8
Less thAn 29" wide
8ft
and 16 depth or less
i ! •
1
• a !
208 -3 -60
PENN
S a b a
HOOD
:a,&.
SF -1
:
5400
0.50"
1150
BEL'.T
2
7
208 -3 -60
PENN
SX205BC
• •
HOOD
+
•a••
•
•a!•• a
o
_ _ m
• a
2X2 FLANGE ON
2X2 ANGLES WITH l
5/8" BOLTS ,NUTS
WASHERS
TOTAL OF 4
2X2 FLANGE FROM -
3/8' THREADED RODS
NUTS, WASHERS
ON ONE INCH RUBBER
GASKETS
TOTAL: 2 FLANGES
4 RODS & GASKETS
�-- MOTOR & DRIVE OUT OF
AIR STREAM
IN -LINE FAN
( 4 )- 1" SPRING ISOLATORS
IN -LINE FAN MOUNTING DETAIL
NITS
STANDARD 3" WIDE HANGERS
Hanget extension to be the sum
of the distances between the hangin
wires and the duct size, ID (Smacna�
Maximum Hanger
Duct size, Inches
Spacing
48: Wide or grater
4 ft
Less tho 48" wide
6ft
and less than 48"
Profile
deep
24
Width between 28"
6ft
& 48" and greater
3" X 2"
than 16" deep
f8
Less thAn 29" wide
8ft
and 16 depth or less
BEL ".T
CHANNEL SECTION
If Total
Minimum
Minimum
Extension is
Channel
Channel
not greater than:
Gauge
Profile
6„
24
3" X 1.5"
18"
22
3" X 2"
30"
f8
3„ X 2„
USE OF 2" WIDE
22 gauge 2'x 1.5" hangers may be substituted
for 3" hangers for ducts with widths not over 48"
and depths not over 24" provided that not more
than one joint occurs between hangers and the
maximum hanger spacing 4ft. Exception: When
duct perimeter is 80" or less and does not
require reinforcement two joints are permitted
between hangers
9
3
aaa
a
/
T �
FAN SCHEDULE f
MARK
TYPE
CFM
ESP
IWG
RPM
ORRIVE
HP
AMPS
VOLTAGE
MANUFAC.
MODEL
CONTROL
AREA SERVED
NOTES
EF -1
IN -LINE
6000
1.5
1030
BEL ".T
3
9
208 -3 -60
PENN
SX2258C
FAN SWITCH
HOOD
PROVIDE DISC. SWITCH
SF -1
IN -LINE
5400
0.50"
1150
BEL'.T
2
7
208 -3 -60
PENN
SX205BC
FAN SWITCH
HOOD
PROVIDE DISC. SWITCH
:f r
I I
c3 CO
z
0
OJ N
d M pp
C:" _j c0
o
S
J
M M
p O
W
o:
V
Lj
w
c
0
QLL_
°
a
0
+'
0
a
0
W
~ J
v Q
N
H
c3 CO
OJ N
d M pp
C:" _j c0
o
S
J
M M
p O
;
c�
Z °
0
V
Lj
c
0
QLL_
°
Z
o
+'
0
a
0
v
~ J
v Q
N
H
w
} - O
L
o
�
U Q
0'
z o
w s
C1 pp
v
o
o
-
. I
w
Z
LO
p
Z
o
v
co
a
0
W
N
-
a
O
o
�