Loading...
06-847-021TYPE PANEL BOARD » » MAIN BUS 200 A. SERVICE 30, 4W PANEL C MAINS M.C.B. VOLTAGE 120/240 A.I.C. 10,000 CONNEC. KVA POLE TRIP DUIT WIRE REMARKS CKT. NO. CKT. NO. REMARKS WIRE CON DUIT TRIP POLE CONNEC. KVA 0.48 1 20 1/2" #12 WALK -IN- COOLER 1 'k 'I` * c * c * * �k * * 2 4 ICE MACHINE #12 1/2" 20 2 4.80 2.49 1 20 1/2" #12 DISHWASHER MACHINE 3 6.00 2 40 3/4' #6 HIGH LEG 5 6 HIGH LEG 20 1/2" #12 EXIST. LOAD 9 11 1.20 1 20 1/2" #12 REFRIGETATOR 7 8 POS PRINTER #12 1/2" 20 1 1.00 1.50 1 20 1/2" #12 CAPUCHINO 9 10 POS PRINTER #12 1/2" 20 1 1.00 12 EXIST. LOAD #12 1/2" 20 HIGH LEG 11 12 HIGH LEG 20 1/2" #12 EXIST. LOAD 13 1.00 1 20 1/2" #12 IPOS PRINTER 13 14 16 18 FUTURE EQUIP. 20 1/2" #12 EXIST. CU LOAD 6.24 1.20 1 20 1 2" 12 HOT TOWEL HEATER 15 18 EXIST. LOAD #12 1/2" 1 20 HIGH LEG 17 1.20 1 20 1/2" #12 COFFE MAKER 19 20 HIGH LEG #12 1/2" 20 1 0.72 1.20 1 20 1/2- #12 SODA DISPENSER 21 22 24 FUTURE EQUIPMENT #12 1/2" 20 1 11.78 1.00 1 20 1/2" #12 HIGH LEG 23 6.65 3 40 3/4" #8 NEW RTH 25 27 29 26 HIGH LEG 20 1/2" #12 EXIST. LOAD 25 28 GEN. OUTLETS #12 1/2" 20 1 1.08 30 GEN. OUTLETS #12 1/2" 20 1 0.72 28 EXIST. LOAD #12 1/2" 20 HIGH LEG 31 32 HIGH LEG 20 1/2" #12 JEXIST. LOAD 29 1.44 1 20 1/2" #12 WALK -IN- FREEZER 33 34 GEN. OUTLETS #12 1/2" 20 1 0.72 1.00 1 20 1/2- #12 POS PRINTER 35 36 COND. COOLER #12 1/2" 20 1 0.96 34 EXIST. LOAD #12 1/2" 20 HIGH LEG 37 38 SPACE 40 3/4' #6 EXIST. LOAD 35 37 0.62 1 20 1/2" #12 COND. FREEZER 39 40 EXIST. CU LOAD #12 1/2" 20 2 2.00 39 40 SPACE 41 42 _±L] 42 TOTAL LOAD : 37,560 VA LOAD CALCULATIONS: KITCHEN EQUIP.(35.39 KVA)240 10: 85 VA KITCHEN EQUIP.(12.89 KVA)240 30: 31 VA TOTAL DEMAND LOAD : 116 A FEEDER:4 # 4/0 CU,THW IN 2.5" CONDUIT. * - KITCHEN LOADS I I EXISTING 3 # 4/0 CU, .6W IN 2.5" COND. r- ------- a---- - - - - -� - - - - - - - - - - I EXISTING LINE GUTTER I I EXISTING L----- --T - -J 250A MCB I I rEXISTING rEXISTINO EXISTING I 3 # I I I PANEL "A' I I PANEL "B' 1 400 CU,1TiW / IN 3' COND. -, I I I I 1200 A. ML01 1150 A. ML01 _L 1 1 120/240 1 1 110,3w 1 110.3w 1 METER I T I 1 1 PH.,3W I I 1120/24-OV I 1120/240V I I M 1 I - - - -� A.I.c00.000 I I L -_ -J L_ _J 1 " -/ I I I I T L EXISTTNGJ L _NE 3R J I - MA - I I EXISTING F' - - I 3 # 4/0 CU. THW I EXISTING I I I IN 2.5" COND. I 4 # 210 CU THW IN 2' COND. -J IF- ------------------------ - - - - I I I L _ _ J GROUND FLOOR /EXTERIOR ( GROUND FLOOR /INTERIOR I EXISTING 150 A -2P EXISTING ELECTRICAL RISER DIAGRAM EXISTING 10 3W SERVICE SERVICE FROM UTILITY COMPANY NEW 4 #4/0 THW, CU. WIRES IN 2.5 "C. OVERHEAD SERVICE FROM FP &L FP&L DROP TO BE AT EXISTING DROP LOCATION. METER TO BE SET IN PHASE 2 ON A SUNDAY 4 # 4/0 CUJH IN 2.5' COND. 4 # 4/0 CU, IN 2.5' CONO. 150A MCB r� 120/240 PANEL "C' METER 3 PH.,4W 200 A, MLO 30,4W 120/24-OV O A. I.C.: 10,000 NEMA 3R GROUND FLOOR /EXTERIOR GROUND FLOOR /INTERIOR #4 CU. GROUND M.C.W.P. r1 WATER PIPE e (MIN.) GROUND WIRE �- 3/4 "0x10' -0 "L COOPER CLAD TIED TO STRUCTURAL GROUND RODS DRIVEN INTO GROUND STEEL IN FOUNDATION. NEW ELECTRICAL RISER DIAGRAM NEW 30 4W SERVICE I (EXISTING PANEL) TYPE PANEL BOARD » » MAIN BUS 200 A. SERVICE 10, 3W PANEL A MAINS M.C.B. VOLTAGE 120/240 (EXISTING PANEL) A.I.C. 10,000 CONNEC. KVA POLE TRIP DUIT WIRE (REMARKS CKT. NO. CKT. NO. REMARKS WIRE DUIT TRIP POLE CONNEC. KVA 6.00 2 40 3/4' #6 EXIST. A,HU LOAD 1 3 * 'k * 2 EXIST. SPACE #8 3/4" 40 2 8.00 4 EXIST. SPACE 30 3/4" #10 EXIST. LOAD 5 6.00 2 40 3/4' #6 EXIST. A,HU LOAD 5 7 6 EXIST. SPACE 20 1/2" #12 EXIST. LOAD 9 11 8 EXIST. SPACE #12 1/2" 20 1 1.00 1.00 1 20 1/2" #12 EXIST. LOAD 9 10 EXIST. LOAD #12 1/2" 20 1 1.00 1.00 1 20 1/2" #12 EXIST. LOAD 11 12 EXIST. LOAD #12 1/2" 20 1 0.72 1.00 1 20 1/2" #12 EXIST. LOAD 13 14 EXIST. LOAD #12 1/2" 20 1 1.50 2.00 2 20 1/2" #12 EXIST. CU LOAD 15 17 16 EXIST. LOAD #12 1/2" 20 1 1.00 18 EXIST. LOAD #12 1/2" 1 20 1 1.00 1.00 1 20 1/2" #12 EXIST. LOAD 19 20 EXIST. LOAD #12 1/2" 20 1 0.72 1.00 1 20 1/2" #12 EXIST. LOAD 21cc 22 EXIST. LOAD #12 1/2" 20 1 1 1.50 1.00 1 20 1/2" #12 EXIST. LOAD 23 24 EXIST. LOAD #12 1/2" 20 1 1.00 1.00 1 20 1/2" #12 EXIST. LOAD 25 26 EXIST. LOAD #12 1/2" 20 1 1.00 1.00 1 20 1/2" #12 EXIST. LOAD 27c 28 EXIST. LOAD #12 1/2" 20 1 0.72 1.00 1 1 20 1/2" #12 JEXIST. LOAD 29 30 EXIST. LOAD #12 1/2" 20 1 1.50 1.00 1 20 1/2" #12 JEXIST. LOAD 31 32 EXIST. LOAD #12 1/2" 20 1 1.00 1.00 1 1 20 1/2" #12 EXIST. LOAD 33 34 EXIST. LOAD #12 1/2" 20 1 1.50 5.00 2 40 3/4' #6 EXIST. LOAD 35 37 36 EXIST. LOAD #12 1/2" 20 1 1.00 38 40 EXIST. CU LOAD #12 1/2" 20 2 2.00 39 40 39 _±L] 42 41 42 TOTAL LOAD: 47,160 VA - -- 197 AMPS. LOAD CALCULATIONS: BALANCE(25.94 KVA) 0100% : 25.940 VA KITCHEN EQUIP. (21,220 KVA) 065% : 13,793 VA TOTAL DEMAND LOAD :39,733 VA - -- 165 AMPS. FEEDER:4 # 4/0 CU,THW IN 2.5" CONDUIT. ' - KIIL;HtN LUAUS (EXISTING PANEL) TYPE PANEL BOARD » » MAIN BUS 150 A. SERVICE 10, 3W PANEL B MAINS M.o.B- VOLTAGE 120/240 (EXISTING PANELS A.I.C. 10,000 CONNEC. KVA POLE TRIP DUIT WIRE (REMARKS CKT. NO. CKT. NO. REMARKS WIRE CON DUIT TRIP POLE CONNEC. KVA 2.50 2 20 1/2" #12 EXIST. LOAD 3 r 4 EXIST. CU LOAD #8 3/4" 40 2 8.00 4.18 2 30 3/4" #10 EXIST. LOAD 5 6 EXIST. AHU LOAD #12 1/2" 20 2 2.50 1.00 1 20 1/2" #12 EXIST. LOAD 9 11 10 EXIST. LOAD #12 1/2" 20 1 1.00 12 EXIST. LOAD #12 1/2" 20 1 0.72 1.00 1 20 1/2" #12 EXIST. LOAD 13 14 16 EXIST. LOAD #12 1/2" 20 2 2.40 1.60 1 20 1/2" #12 NEW LIGHTING 15 1.60 1 20 1/2" #12 NEW LIGHTING 17 18 20 EXIST. LOAD #8 3/4" 40 2 5.50 o co Sushi Maki EXIST. SPACE 19 5812 S.W. 72nd St. " South Miami Florida 21 22 EXIST. SPACE Date Dig t�ibution 'rro 23 24 •- PERMIT SET 04 -17 -06 a. N1..ti►j! 25 26 f .. 27 28 29 30 a , r ENERGY SCIENCES INC CONSULTING ENGINEERS +!' 31 32 ESBER ANDIROGLU, P.E. MECR /ELEC. - J42454 ' 2821 DOUGLAS ROAD J t4 " b s + MIAMI, FL 33133 I TEL 305- 448 -8828 33 34 FAX 305 -448 -7375 e -mail energys®bellsouth.net y 35 36 Sheet 37 38 39 40 41 42 TOTAL DEMAND LOAD 29,800 VA - -- 124 AMPS. FEEDER:4 # 1/0 CU,THW IN 1 1/2" CONDUIT. r'F h c � ELECTRICAL NOTES 1. General A. All work performed under this contract shall comply with all national, state and local codes having jurisdiction and with, the requirements of the utility companies whose services shall be used. All modifications required by these codes shall be made by this contractor without additional charge. B. Drawings: Refer to all drawings for coordination of the electrical work. C. Arrange and pay for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. Guarantee: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for minimum of one year for material and labor. 2. Contractor is directed to review the building plans and specifications for limitations of constructions, identifications of materials and products, definition of workmanship. This contractor shall include his bid proposal all costs necessary for a complete and operational installation and shall visit the job site prior to a bid date. 3. Contractor needs to establish a field liason with project supervisor, prior to commencing work. 4. All required insurance shall be provided for protection against public liability and property damage for duration of the work. 5. It shall not be the intent of these plans and /or specifica- tions to show every minor detail of construction. The electrical contractor shall be expected to furnish and install all items for a complete electrical system and provide all requirements necessary for equipment to be placed in proper working order. 6. Electrical contractor shall not scale drawings. Contractor shall refer to architectural plans and elevations for exact locations of all equipment unless otherwise noted. 7. All conduit runs are shown diagram mactically. Exact routing shall be determined in the field, unless otherwise noted. 8. Electrical contractor shall visit the job site and verify all conditions, locations, dimensions and counts as shown and /or noted on the drawings. This shall include any and all fabrications prior to installations. 9. As a minimum, all equipment shall meet applicable standards, for the type of equipment and intended use, of the following: C1. American National Standards Institute (ASTM). b. Illuminating Engineers Society (IES). C. American Society for Testing and Materials (ASTM) d. National Electrical Manufacturers Association (NEMA). Note: These standards are subordinate to codes, and standards set by UL. 10. All electrical equipment, devices, wire, ect. shall be listed, for the intended use, with Underwriter laboratories, Inc. (UL), where standards have been established by UL. 11. As -built drawings shall be furnished to the owner upon completion of work. 12. Wiring devices to be spec. grade. 13. Where more than one devices is indicated at any location, these shall be ganged under one common cover plate. 14. Contractor shall coordinate with electric and telephone utility for service entrance location and any other require- ments. 15. All connections to ground rods shall be made with UL approved welded connections, unless noted otherwise. 16. Provide a fuse holder and fuse in the primary side of each ungrounded conductor for all ballasts. 17. Unless noted as existing, all equipment, wiring, devices, etc. shall be new. Contractor shall guarantee all materials and workmanship free from defects for a period of not less than (1) year from date of acceptance, unless indicated of specified otherwise. 19. Correction of any defects shall be completed without additional charge and shall include replacement or repair of any other phase of the installation which may have been damaged thereby. 20. Electrical contractor shall provide temporary service for use of all trades as required for construction. 21. Temporary wiring to be removed by contractor. 22. Electrical contractor shall verify requirements, exact location and type or outlet for all electrical fixtures, appliances and equipment. 23. Shop Drawings: Coordinate requirements with architect. 24. All wiring to have 600 volt insulation, type TW, THW, THWN, for branch circuits and type THW, THN for main feeders or as specified. 25. Design is based on copper conductor. Wire size #10 and smaller type "TW ", wire size #8 and larger type "THW" or as specified. 26. Wire ways shall be sized as required, per NEC, unless otherwise noted. 27. All feeder, subfeeder and branch circuits shall be properly phase balanced. 28. All conductors shall be in conduits. All conduits shall be intermediate (IMC) or rigid galvanized steel (RGS) except that: (a) poly vinyl chloride (PVC) conduits may used in concrete slabs at underground provided elbows and riser are RGS; (b) electrical metallic tubing (EMT) may be used in or on walls or ceilings where not subject to mechanical damage, damp conditions or corrosive conditions; (c) liquid tight flexible conduits where required; (d) flexible metallic conduit where required in dry locations. All conduit hazardous areas (per NEC) shall meet the requirements of NEV Chapter. I t 29. Apply bitumostic coating to all metallic conduits in slabs + or underground. > 30. Electrical contractor shall verify circuit protective device rating for equipment prior to construction. 31. Provide fuse recommended by equipment manufacturer. 32. Furnish and install disconnect switches and wiring for air'>f conditioning systems as per manufacturer recommendations. U - Controls are to be supplied by air conditioning contractor. 33. Install power and control wiring and required control components for air condition systems as shown /noted on �. these drawin s and per other applicable drawings/instruc- tions see A�C drawings. 34. Electrical contractor to run control wires for HVAC system as per HVAC drawings. 35. No conduits to be run in ductwork. 36. All electrical wiring must be in conduit (no Romex, BX, etc. is permitted unless specific permission is obtained from s+"',- . owner, engineering or local inspector). 37. All light switches shall be white "Decora" �T 38. All switches shall be ganged N�k 3 ELECTRICAL RISER & DIAGRAM `[ ARCHITECTURE PLANNING INTERIORS U H E , F. S H` VI T' At C ORAZZI NJ! 300 ARAGON AVENUE -)#SUITE CORAL GABLEP, FLORIDA TEL• 305- 567 -6602, FAX: 305 - 446 -3197 *; FLORIDA REGISTRATION,'AA C2194, cfl r Burton H. Hersh, AIA , ,p Au -onAn „ r f. 9a Luigi Vitalini AR -13513 Pablo Corazzini AR -91716 t at E-j3 H:,Curnm1,N.j.1 D, Rykm Plalrg,u3 U cfl r co 4-J O ., o •, � Z ' s O- p� Cd o co Sushi Maki 5812 S.W. 72nd St. " South Miami Florida &' Ject No. 04033 Date Dig t�ibution 'rro 4 •- PERMIT SET 04 -17 -06 a. N1..ti►j! f .. a , r ENERGY SCIENCES INC CONSULTING ENGINEERS +!' " ESBER ANDIROGLU, P.E. MECR /ELEC. - J42454 ' 2821 DOUGLAS ROAD J t4 " b s + MIAMI, FL 33133 I TEL 305- 448 -8828 4 tj k FAX 305 -448 -7375 e -mail energys®bellsouth.net y Sheet E-j3 H:,Curnm1,N.j.1 D, Rykm Plalrg,u3