06-847-018CONDENSING UNIT UNIT N❑, FLAT STRAPS SECURE TO FRAMEWORK TO SENSIBLE WITHSTAND 150 MPH WINDS 2 -16 GA, X 1 1/2' FLAT IN FITTING IN ACCORD TO HEAT STRAPS DRAWN TIGHT, IS❑M ❑DE PADS UNDER USE SEALER AND WELDED TO C SECTIONS. 4 CORNERS OF UNIT FLEXIBLE DUCT AIR FLOW DUCT CONNECTION DETAILS COIL KW V. WELD. TYP. EACH SIDE, 3'X 3'X1/4' SQ, co FLA 2" X 4" - ALUMINIUM ALUMINIUM PLATE Ph MOUNTING) 'C' CHANNEL WELD TO PIPE 'C' CFM &P. IN 1 1/2" X 1 1/2" POST & CHANNEL, A O ALUMINIUM ANGLE BR. 3" DIA. ALUMINIUM 5,8 i, 208/230 CARRIER W /R -22 REF, • �--� 3 1/2' X 3 1/2' X 1/4' POST `x (Cj U ALUMINIUM PLATE PITCH POCKET 48HJE009 -5 101,200 68,900 WELDED TO PIPE POST, & FILL W /PITCH (2)15.0 CO 1/4 NONE BOLTED W/3/8' 0 BOLT TO ROOF 1st Ciro 7 -14 I,b -oz, 880 Lbs 4' X 4' PLATE CONCRETE SLAB 2nd Circl 8 -5 lb -oz, NOTE: PROVIDE 2' -0" MIN. CLEARENCE AROUND 3 SIDES OF UNIT. ALL ROOFTOP MOUNTED EQUIPMENT EER -13,00 SUPPORTS SHALL COMPLY WITH FBC, MECH, 301,13, 304.8 AND 305,5, C.U. I" IOUNTINGs DETAIL NTS PLASTIC OR METAL BUSHINGS CLINCH EDGES 1/4 "0 GALV. BAR— TO BRANCH DUCT ` GALV. STEEL RODS [a TRUNK DUCT 18 GAGE GALV_ SHEET FSTEEL DAMPER BLADE: FULL HEIGHT OF MAIN DUCT. DOUBLE BEND LEADING EDGE POSSIBLE OF DAMPER BLADE AIR FLOW SET SCREW SPACER REQ'D. ON INSULATED DUCTS TYP. DETAIL OF 90' DUCT TAP WITH DAMPER BLADE ELBOW TURNING VANES W /SIN. SCREW FA8TERNER6 IN DUCTS 8" O.C. OR LARGER FLEXMASTER SPIN -IN DAMPER AND EXTRACTOR SCOOP FITTING MODEL NO. DBDE FOR FI15EROU5 GLASS DUCT BOARD. H V A,C, NUTES 1, ALL WORK SHALL BE AS PER S,F,B,C, AND NFPA 2, ALL AIR CONDITIONING DUCT WORK SHALL BE FIBERGLASS, AS MANUFACTURED BY OWENS- CORNING, TYPE 800 (15' THICK), R =6, 3. DUCT WORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & ACCORDING TO ASHRAE & SMACNA STANDARDS AND IN COMPLIANCE WITH UL 181. 4. DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS WIDTH x HEIGHT. DUCT SYSTEM SHALL COMPLY WITH NFPA STD, NO, 90A AND /OR 90B, DUCTWORK AND MATERIALS SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U,L, 181 TESTS, 5, COORDINATE LOCATIONS, SIZES & OPENINGS W /OTHER TRADES ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT SYSTEM W /TURNING VANES AT ALL ELBOWS. SPILITTERS AND DAMPERS AS REQUIRED, A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TRADE IN THE FABRICATION AND INSTALLATION OF THE SYSTEM. 6. ALL SUPPLY AIR AND RETURN AIR GRILLES /DIFFUSERS SHALL BE NEW, AND SHALL BE LOCATED AND BALANCED IN ORDER THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY & DRAFT FREE TO MAINTAIN THE FOLL ❑WING DESIGN CONDITIONS, INSIDE OUTSIDE RELATIVE HUMIDITY COOLING - 76 DB 90 DB - 79 WB 50Z TO 60X 7. ALL TEMPERATURE CONTROLS SHALL BE VIA A CENTRAL PROGRAMMABLE THERMOSTAT. MOUNT ALL T'STATS AT 48'A,F,F, 8. ALL NEW GRILLES AND DIFFISURES TO BE ALUMINUM CONSTRUCTION. DIFFUSERS SHALL HAVE HIDDEN OPPOSED BLADE DAMPERS, PROVIDE GASKETS ON ALL GRILLES & DIFFUSERS, 9. PROJECT ARCH, SHALL REVIEW AND APPROVE ALL DIFFUSER TYPES & FINISHES PRIOR TO PURCHASE AND INSTALLATION, 10. ALL CONDITIONS AND SYSTEMS NOTED AS EXISTING SHALL BE FIELD VERIFIED. ALL NECESSARY SERVICE & REPAIRS SHALL BE PROVIDED TO THE EXISTING SYSTEM IN ORDER TO ENSURE PROPER OPERATION, 11. CONTRACTOR SHALL FIELD VERIFY /COORDINATE ALL CONDITIONS AND PARAMETERS W /OTHER TRADES INVOLEVED W /THE PROJECT, LOW VELOCITY 5UPPLY AIR DUCT ISEE PLAN VI METAL ROUND FITTING QUADRANT OPERTOR TO BE OUTSIDE INSULATION. PROVIDE INSULATION GUARD WHERE NECESSARY PROVIDE P FI5ERGLA55 INSULATION SEALED TO NECK t PERIMETER OF DIFFUSER— D IFFU8ER SHEET LEAD FLASHING MOP IN WITH ROOFING MATERIAL AIR FLOW INSULATED FLEX. DUCT (S' -O" MAXIMUM) THERMOFIN OR EQUAL ONLY IN A NONE SPRINKLERED BLDG. SEAL JOINT WITH DUCT a= AI Y=tD A TA== FLEX. DUCT / D II=I =U5Efi`R CONN. DETAIL Outside Air Intake Calculations per ASHRAE NEW SPACES OCCUPANCY OF SPACE SERVED BY RTU #11 40 PEOPLE 15 CFM / PERSON OF ❑/A INTAKE REQUIRED 15 CFM / PERSON X 40 PEOPLE = 600 CFM SET BUILTIN VOLUME DAMPER IN RTU #1 AT 600 CFM, 4'0 DRYER EXH, UP 18 GAGE GALV, METAL ROOF CONSTRUCTI ❑N SLEEVE ROOF C❑NSTRUCTI ❑N BACKDRAFT DAMPER - -m AS REQUIRED DRYER �c EXH. DUCT THRU ROOF DETAIL. N.T.S. NOTE+ 1. ALL DRYER & BATH ROOM EXH, DUCTS SHALL BE 24 GA. GALV, METAL, EQUIPPED WITH BACKDRAFT DAMPER AND WIRE MESH SCREEN, SEE FLOOR PLANS AND ROOF PLAN FOR ALL TERMINATION POINTS. 2, KITCHEN HOOD EXH. DUCT SHALL BE 18 GA. GALV, METAL, EQUIPPED WITH BACKDRAFT DAMPER AND WIRE MESH SCREEN, SEE FLOOR PLAN FOR TERMINATION POINT. 3. ALL DUCT REINFORCEMENTS SHALL BE PER SMACNA REQUIREMENTS, SEE DUCT HANGER DETAIL ON THIS SHEET. Roof Top Package System Air Conditioning Unit Schedule UNIT N❑, MANUF, MOD, UNIT N❑, - SENSIBLE JOIN FLEX DUCT TO SPIN - COM. OUT IN FITTING IN ACCORD TO HEAT MFGR. INSTALL. INSTRUCT. EER USE SEALER AND WT. (LB). BANDING DEVICE. FLEXIBLE DUCT AIR FLOW DUCT CONNECTION DETAILS H V A,C, NUTES 1, ALL WORK SHALL BE AS PER S,F,B,C, AND NFPA 2, ALL AIR CONDITIONING DUCT WORK SHALL BE FIBERGLASS, AS MANUFACTURED BY OWENS- CORNING, TYPE 800 (15' THICK), R =6, 3. DUCT WORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & ACCORDING TO ASHRAE & SMACNA STANDARDS AND IN COMPLIANCE WITH UL 181. 4. DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS WIDTH x HEIGHT. DUCT SYSTEM SHALL COMPLY WITH NFPA STD, NO, 90A AND /OR 90B, DUCTWORK AND MATERIALS SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U,L, 181 TESTS, 5, COORDINATE LOCATIONS, SIZES & OPENINGS W /OTHER TRADES ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT SYSTEM W /TURNING VANES AT ALL ELBOWS. SPILITTERS AND DAMPERS AS REQUIRED, A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TRADE IN THE FABRICATION AND INSTALLATION OF THE SYSTEM. 6. ALL SUPPLY AIR AND RETURN AIR GRILLES /DIFFUSERS SHALL BE NEW, AND SHALL BE LOCATED AND BALANCED IN ORDER THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY & DRAFT FREE TO MAINTAIN THE FOLL ❑WING DESIGN CONDITIONS, INSIDE OUTSIDE RELATIVE HUMIDITY COOLING - 76 DB 90 DB - 79 WB 50Z TO 60X 7. ALL TEMPERATURE CONTROLS SHALL BE VIA A CENTRAL PROGRAMMABLE THERMOSTAT. MOUNT ALL T'STATS AT 48'A,F,F, 8. ALL NEW GRILLES AND DIFFISURES TO BE ALUMINUM CONSTRUCTION. DIFFUSERS SHALL HAVE HIDDEN OPPOSED BLADE DAMPERS, PROVIDE GASKETS ON ALL GRILLES & DIFFUSERS, 9. PROJECT ARCH, SHALL REVIEW AND APPROVE ALL DIFFUSER TYPES & FINISHES PRIOR TO PURCHASE AND INSTALLATION, 10. ALL CONDITIONS AND SYSTEMS NOTED AS EXISTING SHALL BE FIELD VERIFIED. ALL NECESSARY SERVICE & REPAIRS SHALL BE PROVIDED TO THE EXISTING SYSTEM IN ORDER TO ENSURE PROPER OPERATION, 11. CONTRACTOR SHALL FIELD VERIFY /COORDINATE ALL CONDITIONS AND PARAMETERS W /OTHER TRADES INVOLEVED W /THE PROJECT, LOW VELOCITY 5UPPLY AIR DUCT ISEE PLAN VI METAL ROUND FITTING QUADRANT OPERTOR TO BE OUTSIDE INSULATION. PROVIDE INSULATION GUARD WHERE NECESSARY PROVIDE P FI5ERGLA55 INSULATION SEALED TO NECK t PERIMETER OF DIFFUSER— D IFFU8ER SHEET LEAD FLASHING MOP IN WITH ROOFING MATERIAL AIR FLOW INSULATED FLEX. DUCT (S' -O" MAXIMUM) THERMOFIN OR EQUAL ONLY IN A NONE SPRINKLERED BLDG. SEAL JOINT WITH DUCT a= AI Y=tD A TA== FLEX. DUCT / D II=I =U5Efi`R CONN. DETAIL Outside Air Intake Calculations per ASHRAE NEW SPACES OCCUPANCY OF SPACE SERVED BY RTU #11 40 PEOPLE 15 CFM / PERSON OF ❑/A INTAKE REQUIRED 15 CFM / PERSON X 40 PEOPLE = 600 CFM SET BUILTIN VOLUME DAMPER IN RTU #1 AT 600 CFM, 4'0 DRYER EXH, UP 18 GAGE GALV, METAL ROOF CONSTRUCTI ❑N SLEEVE ROOF C❑NSTRUCTI ❑N BACKDRAFT DAMPER - -m AS REQUIRED DRYER �c EXH. DUCT THRU ROOF DETAIL. N.T.S. NOTE+ 1. ALL DRYER & BATH ROOM EXH, DUCTS SHALL BE 24 GA. GALV, METAL, EQUIPPED WITH BACKDRAFT DAMPER AND WIRE MESH SCREEN, SEE FLOOR PLANS AND ROOF PLAN FOR ALL TERMINATION POINTS. 2, KITCHEN HOOD EXH. DUCT SHALL BE 18 GA. GALV, METAL, EQUIPPED WITH BACKDRAFT DAMPER AND WIRE MESH SCREEN, SEE FLOOR PLAN FOR TERMINATION POINT. 3. ALL DUCT REINFORCEMENTS SHALL BE PER SMACNA REQUIREMENTS, SEE DUCT HANGER DETAIL ON THIS SHEET. Roof Top Package System Air Conditioning Unit Schedule UNIT N❑, MANUF, MOD, UNIT N❑, TOTAL CAP, SENSIBLE EVAPORATOR COM. OUT BLOW HEAT HVAC UNIT EER CHARGE WT. (LB). BTU /HR CAP BTU /HR AIR FLOW RLA DOOR FAN COIL KW V. (POSITI ❑N OF CURB (LB), co FLA FLA HP V -Ph A Ph MOUNTING) CFM &P. IN A O 5,8 i, 208/230 CARRIER W /R -22 REF, • �--� En `x (Cj 4 3 3 RTU# 1 48HJE009 -5 101,200 68,900 31000 0.6 (2)15.0 1,4 1/4 NONE NEW ZONE 1st Ciro 7 -14 I,b -oz, 880 Lbs 2nd Circl 8 -5 lb -oz, EER -13,00 143 Lbs ROOFTOP, DOWN FLOW, OUTDOOR C ❑NDITIONSi 91'F DB, 79'FWB V - VOLTS INDOOR CONDITIONSi 74'F DB, RELATIVE HUMIDITY = 50X ph - NUMBER OF PHASES x WITH BUILT -IN OUTSIDE AIR INTAKE DAMPER a - FUSE AMPS ROOF TOP UNIT 24x24 SUPPLY GRILLE SECURE TO FRAMEWORK TO WITHSTAND 150 MPH WINDS 2 -16 GA. X 1 1/2' FLAT - STRAPS DRAWN TIGHT, BOLTED TO ROOF STRUCT, ROOF CURB (DADI COUNTY PRODUCT APROVAL), ROOF STRUCTURE TERMINATE EXH. DUCT W /RAIN CAP PROVIDE WIRE MESH SCREEN IN DUCT, BOLTED W/3/8' 4 BOLT T 4' X 4' PLATE TE n r— ROOFING 7,.,,0 /A ROOF TOP AC UNIT <100% ❑ /A) FOR COMM ❑MN AREAS 2 HR FIRE RATE DUCT CHASE, 22 GAGE, GALVANIZED METAL S/A DUCT, DUCT SMOKE DETECTOR IN SUPPLY AIR DUCT J CL 0- D 0 ANGLE SUPPORT ROOFTOP AC UNIT TIE DOWN & DUCTS DETAIL AIR CONDITIONING HOUSING --- CANT, STRI 0 2 #3 CONT d; CANT. STRIP BUILT UP R❑❑FI ROOF INS —. a N T,S, PROVIDE 1/2' THRU BOLTS (AT 8 LOCATIONS MIN) THRU BOTTOM OF UNIT HOUSING INTO TOP OF CURB BOLT TOP OF CURB TO AIR CONDITIONING HOUSING TO WITHSTAND HURRICANE WINDS AS PER LOCAL CODE CURB GASKET TAIL CURB SUPPORT CONCRETE ROOF. #3@ 12' O,C. W /STD HOOK, N❑TESI 1. CURBS SHALL BE FACTORY FABRICATED WITH INSULATION, 2. INSTALL ELECTRICAL CONDUIT SIMILAR TO CONDENSATE DRAIN. 3. ROOF EQUIPMENT CURBS MUST BE PROVIDED WITH PROPERLY DESIGNED FABRICATED LEVELING DEVICES, S❑ THE EQUIPMENT IS LEVEL AND CURB INSTALLATION MATCHES THE ROOF SLOPE, 4. CURB SHALL NOT REST ON ROOF INSULATI ❑N, 5. RESLOPE ROOFING TO PROVIDE ADEQUATE DRAINAGE, ROOFTOP UNIT CURB MOUNTING DETAIL FOR CONCRETE ROOF (TYP) nts ARCHITECTURE PLANNING INTERIORS s 5 s ;{ :v H E R S H VITA LI N CORAZZINI Luigi Vitalini AR -13513 Pablo Corazzini AR -91716 Sushi Maki 5812 S.W. 72nd St. South Miami U Project No. 04033 Distribution Date PERMIT SET 0 BLDG DEPT COMMENTS 04-17 -06 06/08106 H • 1- I co ca O i, • �--� En `x (Cj 4 o � z ILI o Cf) 00 Sushi Maki 5812 S.W. 72nd St. South Miami Florida Project No. 04033 Distribution Date PERMIT SET 0 BLDG DEPT COMMENTS 04-17 -06 06/08106 ESI ENERGY SCIENCES IN�- CONSULTING ENGINEER$ ESHER ANDIROGLUl :0' 'Y • MECH /ELEC. - #.4?245 s' 2821 DOVGLA3r� MIAMI, FL 331 TEL 306- 448 -8 it FAX 305 -448 -7 e —mail energys0bella i.A Sheet Mo 202 tit R t iq C) . U I •� A Y; R\P, 1cd Dr inp104033 - Sushi Maki -South Miami \MEP,04033- M- 201.dw&, 6; 82006 6:18:45 PM, ARCH upend D (24.00 x 3fi OO indms)