06-847-0001 SITECN ENVIRONMENTAL CORPORATION O6 -Sq �- 2518 Island Drive Miramar, Florida 33023 Phone 954 962 -7804 Fax 954 962 -8875 REPORT OF ASBESTOS ABATEMENT & WORK -IN- PROGRESS /CLEARANCE AIR TESTING RETAIL SPACE 5810 SUNSET DRIVE MIAMI, FLORIDA SITECH PROJECT: 1226001 PREPARED FOR: CANTON & SUSHI MAKI RESTAURANTS 4573 PONCE DE LEON BOULEVARD CORAL GABLES, FLORIDA 33146 PREPARED BY: SITECH ENVIRONMENTAL CORPORATION 2518 ISLAND DRIVE MIRAMAR, FLORIDA 33023 APRIL 10, 2006 Winston kadhay Mi Senior Project Manager F.0 0 F, F I�l1.�i7GJlV.7 �VVIiOWIlm1�91 ='_'- April 10, 2006 Mr. Abe Ng Canton & Sushi Maki Restaurants 4573 Ponce De Leon Boulevard Coral Gables, Florida 33146 RE: Report of Asbestos Abatement & Work -in- Progress /Clearance Air Testing for the Retail Space Located at 5810 Sunset Drive, Miami, Florida ( "the Site ") Dear Mr. Ng: Enclosed please find the analytical results and certification for the asbestos abatement and clearance air testing performed at the site. The abatement project consisted of the removal of approximately 320 square feet of asbestos containing vinyl floor tile and mastic within the south area of the retail space. The abatement was conducted by affiliate Anders Environmental Group, Inc., on April 5, 2006, under the supervision of Sitech Environmental Corporation ( "Sitech ") representative Mr. Winston Radhay. The work areas were regulated and enclosed with polythene sheeting to create a containment. A HEPA machine was used to create negative pressure within the work area. The materials were abated underwet conditions and caution was taken to not cause a fiber release into the air. No visible emission of dust to the outside areas were observed during the abatement activities. Prior to encapsulation of the work areas, a visual inspection of the work areas was performed. All accessible previously identified asbestos - containing vinyl floor the and mastic material within the south area of the space was removed and the work area was clean and free of visible debris. A total of five (5) area samples including two (2) Quality Control Blanks were collected during the work -in- progress /clearance air testing performed within the site during the removal of the asbestos - containing materials. The results of the analysis of the samples utilizing the NIOSH 7400 Method did not reveal fiber concentrations above the Environmental Protection Agency (EPA) clearance criteria of s 0.01 fiber per centimeter (f /cc) signifying that the air in the work areas is acceptable and ready for re- occupancy. The results of the analysis can be found in Attachment A "Clearance Air Test Analysis Report". The certifications for air testing can be found in Attachment B "Certifications ". A copy of the DERM notification can be found in Attachment C "Notification to DERM" SEC is pleased to have been of assistance to you on this project, and looks forward to continue working with your firm. If you should have any questions, please do not hesitate to call me at (954) 962 -7804. Sincerely, Sitech Environmental Corporation P-Winst Radhay Senior Project Manager Attachment A CLEARANCE AIR TEST ANALYSES REPORT CLEARANCE AIR TEST ANALYSES REPORT Client: Canton & Sushi Maki Restaurants Date: 4/5/06 Address: 4573 Ponce De Leon Boulevard Coral Gables, Florida 33146 Project: Work -in- Progress /Clearance Air Test Retail Space 5810 Sunset Drive Miami, Florida 33143 Job Number: 1226001 Analyst's initials: WR SAMPLE TYPE OF SAMPLE AND FIB /FLD TIME RATE VOL F /CC NO. LOCATION (min) Umin (liters) 01 Field Blank 0/100 N/A N/A N/A N/A 02 Field Blank 0/100 N/A N/A N/A N/A 03 Clearance Air Test - Inside Work 14/100 240 8.0 1,920 0.0036 Area (North) 04 Clearance Air Test - Inside Work 16/100 240 8.0 1,920 0.0041 Area (South) 05 Clearance Air Test - Outside 9/100 240 8.0 1,920 0.0023 Work Area (North Area of Space) N/A = Not Applicable S,;7Van yz ed using the Phase Contrast Microscopy (PCM) NIOSH 7400 method. Winstonl Radhay Analyst AC# 2 2 4 1 98 6 ,STATE -OF FLORIDA DEPARTMENT OL?_BUSINESS =AND PROFESSIONAL - REGULATION ASBESTOS= LICENSING UNIT SEQ#L0509300565' • s LICENSE NBR 09 30 2'005 0'50283`]73 ZA00002'67_�:�y. The,-ASBESTOS, BLTSTNESS ORGAkIZ�i'�• Name'd' below _ 1$, - .LICENSED` Under the provisions of Chapt�$FS . y" Expiration date: NOV 30, 2007 =��r SITECH. ENVIRONMENTAL'.:.CORPORATIQN'x MICHAEL A.-LAWN 2518 ISLAND DRIVE MIRAMAR FL :33023 JEB BUSH - SIMONE MARSTILLER GOVERNOR DISPLAY AS REQUIRED BY LAW SECRETARY Attachment B CERTIFICATIONS j� i V PV ii 582 EQ UIVALENT COURSE This is to certify that Winston Radhay 88# 087 -72 -0815 has successfully completed the course SAMPLING and EVALUATING AIRBORNE ASBESTOS DUST by examination. Course work included the study of the NIOSH 7400 Method, NIOSH P &CAM 239 Method and the OSHA Reference Method as specified in 29 CFR 1910.1001 and 29 CFR 1926.58 Appendices A & B. Course Location: Hillmann Florida Lab Exam Score: 89 �� ^ Date: September 7 -11, 1993 Dale Payne Course Director Asbestos Consulting Tlaining Systems M, 900 N.W. 5TH Avenue, Fort • Lauderdale, • Florida 37198.•438CERT/ 33311 954) 524-7208 Processed By: This is to Certify that f V%�> > �i s t ��� i� IZi c�� lei �� ar _ _ A e� L� I 3 -_ -f, US To Authenti Certi ica =- im seaguiltraining.co www 0 8 7 7 2 0 8 1 5 1-800-9616-993i 2518 Island Drive. Miramar.FL has successfully completed an Englis Asbestos ContmclodsminTVISOT Reffts '4-Nov-05 4-Nov-05 TO AND CRIM FOR MAKING OR OFF Individual above has completed the requsite training for accreditation under TSCA T'itle 11 R ATIONS (11 10 01"1 U 15)61 T TM TRAI Virginia Accepted and meets state requirements of 326 IAC (IDEM). OF F.1 FMXP-41. Trainer(s): Mark Knick Training Address: 900 NW 5di Ave, Fort Lauderdale, FL 33311 Successful course completion based on exam score. ames F. Stump, Course Sponsor This Certificate Expires: CertWicate Number ....... 1 1 7 8 7 7 0SMT1MINING: 4-Nov-06 I 1 0 4 0 6 4-Nov-06 Course Number SE0544 Se .......... K • 7 1 I r Attachment C DERM NOTIFICATION FLOR1bA Florida Department of Environmental Protection Division of Air Resource Management FYI'F 01 NOI ICI (CHECK ONE ONLY) ❑ ORIGINAL ❑ REVISFD ❑ CANCELLATION Grp COURIESY I1'I'E UI PROECI (CHECK ONE ONLY) 1:1 DEMOLITION ;. RENOVA1ION ❑ ROOFING ���/ ` "` IF DEMOLI I ION, WAS 11 AN ORDERED DEMOLI HONE ❑ YES ❑ NO If RENOVATION IS 11 AN ENICRGENCY RENOVATION OPERAnONf is IT A PIANNED RENOVAI ION OPERATION' IV Fa(_dily Ndmc• AddiesS 5_810 City - - ----IV, , ,)1tr -- -- - - -- Ijurlchng -- Prior Use 1'resent Use. line ilny Owner _4A Address -A_S-73 ('try -- —�° Contra( -tai's Name-- Addiv%s File k U YFS No jIYES ❑ NO Process # e —- __ - -_- _(Square Feet) School /College /University Residence School / College /University Residence EMIL MIAMI -DADE Miamo-Uade DERM Air Seclion I I SM Ind Avenue, Suite 4.111 Miami, Honda 311111 -1540 L. Zrp 3_Cou ty � _�! -72, G - -- Consultant Inspecting Site d iLoi T-4-L- 4 of Floors - Age In Years_ hnal�` ess Other_ 7 Small Business f�- -Phone - -(O6 L- _Phone ( -=LJ-! -) 3 y T^ TZ. _L � _ City - -- -- Vk T� °i/J -- - ____State Zip - - -- I Iorida License No —is the contract exempt from hcensure under Section 469.004(7), FS 1 Sl hedUled Dates• ❑ YES Atihestos Removal (mm /dd /yy) Start �'i �? Finish _�ij.!�( Demo /Renovation (mm /dd /yy) Start -Finish Procedures to he used (Check All That Apply)- {VN0 Strip and Removal Glove gag__ � Bulldozer � doLer —_ _Wrecking Ball Wet Method Dr Method Explode Burn Down `MUST 013FAIN PRIOR DERM APPROVAL BEFORE USING A DRY METHOD VI Procedures for Unexpected RACM. VII Ashesfos Waster Iranapoi ter. Name q�� L_ M - -Phone ( ��y - -) -314 - -- Address - -. (O L_� -S'.j ���,,_�� City -- - Q9M jitJO�— State tip III Waste Disposal Site Name—_ - - -- -- Address _ _3 CEO w �T -- -- City - - _49- --- ___ 1A C_1� _- -State —_Zip 33 IX. Amount of RACM of ACM X Fee Invoice Will Be Sent to Address in Block Below (Print or Type) square feet SUrfd(_lllg material --- _-_ -Imear feet pipe -__ cubic feet of RACM off facility components _Square feet cementitious mat�Jreal _ 3�- Q___square feet resilient Iloormg f :%-" l 4- ---- — -_ - square feet asphall roofing r I certify that the above information is correct and that an individual trained to the provisions of this regulation (40CFR Part 61, Subpart M) will be on -time during the demolition or renovation arid evidence that the required training has been accomplished by this p4rsc4n will be availabjefor inspection during normal business hours/ Name RI (Signature of O tier / Operator) DERM USE ONLY 161 W Ib13 810.3 Postmark /DatJ Received. '*; ID # gSLf 3k4 ! (Contact Phone #) LIMITED SURVEY FOR ASBESTOS CONTAINING BUILDING MATERIALS CANTON AND SUSHI MAKI RESTAURANT 5810 SUNSET DRIVE SOUTH MIAMI, FLORIDA PREPARED FOR: CANTON AND SUSHI MAKI RESTAURANTS (ASIA FOCUS CORP.) 8005 N.W. 90 STREET MEDLEY, FLORIDA, 33166 PREPARED BY: CRB GEOLOGICAL & ENVIRONMENTAL SERVICES, INC. 4573 PONCE DE LEON BOULEVARD CORAL GABLES, FLORIDA 33146 (305) 447 -9777 MARCH 10, 2006 CERTIFICATION PAGE SURVEY FOR ASBESTOS CONTAINING BUILDING MATERIALS CANTON AND SUSHI MAKI RESTAURANT 5810 SUNSET DRIVE SOUTH M "H, FLORIDA mg 3/10/06 Mohammed Florida Licensed Asbestos Inspector r Victor Rossinsky, Jr., Ph.D., P. . Florida Licensed Asbestos Consultant AX 00000026 TABLE OF CONTENTS Page 1.0 INTRODUCTION ..................................................................................... ..............................1 2.0 SITE DESCRIPTION ............................................................................... ..............................2 3.0 SURVEY METHODS AND LABORATORY ANALYSES .................. ..............................3 4.0 SUSPECTED ASBESTOS CONTAINING MATERIALS ................... ..............................4 5.0 DESCRIPTION OF ASBESTOS CONTAINING MATERIAL ........... ..............................5 6.0 CONCLUSIONS AND RECOMMENDATIONS .................................. ..............................6 Tables Table 1— Summary of Laboratory Results Table 2 — Summary of Asbestos Containing Materials Appendices Appendix I — Qualifications Appendix H — Asbestos Laboratory Report & Chain of Custody Record 1.0 INTRODUCTION At the direction of Mr. Abe Ng of Canton Restaurants, a survey of potential asbestos containing materials (ACM) was conducted within the interior of the Canton and Sushi Maki Restaurant Office Space, located at 5810 Sunset Drive, South Miami, Florida. The asbestos survey was performed by Mr. Ashmeed Mohammed, a Florida Licensed Asbestos Inspector (see Appendix I). The purpose of the survey was to locate and identify ACM within the accessible interior building materials. The scope of this survey included the vacant space of the restaurant. The roof and the exterior of the restaurant were not addressed in this scope. Any suspect material encountered within wall cavities and beneath the floor covering should be treated as ACM and should not be disturbed until identified through sampling and analysis. More specifically, the scope of services for this project consisted of the following steps: ➢ Bulk sampling of suspect ACM ➢ Polarized Light Microscopy (PLM) analysis of bulk samples ➢ Final report preparation CNR 539 -05 Asbestos Survey 1 CRB Geological & Environmental Services, Inc. 2.0 SITE DESCRIPTION The commercial property located at 5810 Sunset Drive, South Miami, Florida is a one (1) story building which encompassed an area of 975 square feet. The ceilings consisted of wood. The interior walls were constructed of interior wall plaster and wall board and joint compound. The flooring consisted of vinyl floor tile and ceramic floor tile. CNR 539 -05 Asbestos Survey 2 CRB Geological & Environmental Services, Inc. 3.0 SURVEY METHODS AND LABORATORY ANALYSES Sampling protocol used in this asbestos survey is listed in Title 40, Code of Federal Regulations (CFR), Part 763.86 for friable surfacing materials and friable miscellaneous materials (e.g. ceiling tiles). The U.S. Environmental Protection Agency (EPA) regulations require that sample locations be randomly selected. Suspect ACM were identified and samples of each different type of material were obtained. The bulk sampling procedure utilized for the collection of samples suspected of being ACM within the site required the establishment of homogeneous sampling areas. A homogeneous sampling area is defined as an area of friable or non - friable material of the same type that appeared to be applied or constructed during the same general period of time. This is the most acceptable and cost effective method for sampling of suspect ACM. Samples collected from these pre - determined homogeneous areas were labeled and transported to EMSL Analytical, Incorporated for analysis using PLM of bulk samples. PLM is a method of analysis that utilizes the unique optical crystallographic properties of the various crystalline forms in the samples. These properties such as refractive indices, birefringence, sign of elongation and extinction angle, are unique to crystalline asbestos forms and therefore can be used to identify the type of asbestos mineral as chrysotile, amosite, crocidolite, anthophyllite, tremolite or actinolite. Each type of asbestos displays unique characteristics when subjected to these tests. Percentages of the identified types of asbestos are determined by visual estimation. Attempts are made to mix the sample thoroughly to provide a more accurate percentage. Any material containing over one percent (1 0/6) of any type of asbestos is considered by the USEPA and Occupational Safety and Health Administration (OSHA) to be an ACM and, if disturbed, must be handled according to specific State and Federal regulations. CNR 539 -05 Asbestos Survey 3 CRB Geological & Environmental Services, Inc. 4.0 SUSPECTED ASBESTOS CONTAINING MATERIALS Table 1 lists homogeneous areas identified during the site inspection and laboratory analytical results from bulk sample analysis of the respective building materials. Of the materials tested, two (2) homogeneous areas were identified as ACM by the laboratory. Copies of the analytical results and chain of custody record are included in Appendix II. CNR 539 -05 Asbestos Survey 4 CRB Geological & Environmental Services, Inc. 5.0 DESCRIPTION OF ASBESTOS CONTAINING MATERIAL Two (2) of the homogeneous areas were found to contain more than 1% asbestos. A description of the materials is summarized below, as well as in Table 2, Asbestos Containing Materials. ➢ A brown layer floor tile below the light beige 12" x 12" vinyl floor tile was found in the kitchen area covering an area of approximately 220 square feet. The brown layer vinyl floor tile contained 3% chrysotile asbestos. The material is non - friable and in good condition. ➢ The black mastic below the light brown 12" x 12" vinyl floor tile was found in the storage area covering an area of approximately 130 square feet. The black mastic contained 3% chrysotile asbestos. The material is non - friable and in good condition. CNR 539 -05 Asbestos Survey 5 CRB Geological & Environmental Services, Inc. 6.0 CONCLUSIONS AND RECOMMENDATIONS An asbestos survey was performed within the commercial property located at 5810 Sunset Drive, South Miami, Florida. Results of the survey and laboratory analysis revealed that two (2) of the homogeneous areas tested was ACM as defined in the National Emission Standards for Hazardous Air Pollutants (NESHAP), Title 40 Code of Federal Regulations (CFR) Section 61, Subpart M. Under the National Emission Standards for Hazardous Air Pollutants (NESHAP), all regulated asbestos containing materials (RACK must be abated prior to renovation or demolition with notification to the Florida Department of Environmental Protection (FDEP). RACM includes all friable asbestos containing materials, non - friable asbestos containing materials that have or may become friable and non - friable asbestos containing materials that have been, or will be, subjected to abrasion, exceeding 160 square feet or 260 linear feet. Work involving asbestos containing materials must satisfy all federal, state and local regulations in addition to NESHAP. Identified non - friable asbestos may be managed in place under an Operations and Maintenance (O &M) Plan. In the event the structure is remodeled, refurbished, or demolished, all identified friable asbestos must be abated. Any suspect asbestos containing material discovered in inaccessible areas should be treated as ACM until laboratory analyzed. CNR 539 -05 Asbestos Survey 6 CRB Geological & Environmental Services, Inc. TABLES Table 1 - Summary of Asbestos Results Canton Sushi Maki Restaurant 5810 Sunset Drive South Miami, Florida P W� 1 1A Northwest Wall Area Wall Plaster No asbestos detected 1 1B West Wall Central Area Wall Plaster No asbestos detected 1 1C East Central wall Area Wall Plaster No asbestos detected 2 2A Northwest Area 2'x 4' ACT with Holes And Gashes No asbestos detected 2 2B West Central Area 2' x 4' ACT with Holes And Gashes No asbestos detected 2 2C Central Area In The Kitchen 2' x 4' ACT with Holes And Gashes No asbestos detected 3 3A East Central area In The Kitchen 12" x 12" Light Beige VFT No asbestos detected 3 3A -1 East Central area In The Kitchen Yellow Mastic No asbestos detected 3 3A -2 East Central area In The Kitchen White VFT No asbestos detected 3 3A -3 East Central area In The Kitchen Yellow Mastic No asbestos detected 3 3A-4 East Central area In The Kitchen Brown VFT 3% Chrysotile 3 3B South Of Kitchen Counter 12" x 12" Light Beige VFT No asbestos detected 3 3B -1 South Of Kitchen Counter Yellow Mastic No asbestos detected 3 3B -2 South Of Kitchen Counter White VFT No asbestos detected 3 3B -3 South Of Kitchen Counter Yellow Mastic No asbestos detected 3 3B4 South Of Kitchen Counter Brown VFT 3% Chrysotile 3 3C West Area In The Kitchen 12" x 12" Light Beige VFT No asbestos detected 3 3C -1 West Area In The Kitchen Yellow Mastic No asbestos detected 3 3C -2 West Area In The Kitchen White VFT No asbestos detected CNR 539 -05 Asbestos Survey CRB Geological & Environmental Services, Inc. Table 1 - Summary of Asbestos Results Canton Sushi Maki Restaurant 5810 Sunset Drive South Miami, Florida �. j _ w �� � ��' i - �#c'�� i��� �-- � i t �' ,cl West Area In The 1 1 � -"�� a ..ri � `n J •!;try '� 1' ru"'Erd • • '•+ • k + .�) "'��' �. 1 No asbestos detected West Area In The Kitchen : •' 1 Chrysotile Storage Room 12" x 12" Light Brown VFT No asbestos detected Storage Room Black Mastic 3% Chrysotile OmMW F. �R—ma * 0 0 No asbestos detected 3% Chrysotile Storage Room 12" x 12" Light Brown VFT No asbestos detected Storage Room Black . No asbestos detected West central Area No asbestos detected Southeast Area From The Restroom M-Ir"M No asbestos detected Northeast Area From The Restroom No asbestos detected Notes: HA - Homogenous Area ACT - Acoustic Ceiling Tile VFT - Vinyl Floor Tile CNR 539 -05 Asbestos Survey CRB Geological & Environmental Services, Inc. Table 2 - Asbestos Containing Materials Canton Sushi Maki Restaurant 5810 Sunset Drive Miami, Florida Notes: VFT - Vinyl Floor Tile CNR 539 -05 Asbestos Survey CRB Geological & Environmental Services, Inc. APPENDIX I QUALIFICATIONS 1511 4KOT= 19 #3A',tf UlPt Indivl�nid abovw has opnMjg -ffi8 raq*o trj f ftpr agxaV *n,ynder T� G1x;Tffl Ylrg!nla Aot",and compk&.wfth .W. 206 TSCA 16 .USC 2846. ' Tpker(sr Mack KniCk Trai. ing fees: 900 N.W. 5. th Ave, Pact IAu4cr"o, PL 33311 _. ' �--- ==.- R• essful cgtxse Completioned on exam score. Stump„b S�ibnsar e -ftos$9, .r APPENDIX H LABORATORY REPORTS AND CHAIN OF CUSTODY FORMS EMSL Analytical, Inc. 19501 NE 10th Ave. Bay A. N. Miami Beach, FL 33179 Phone: (305) 650 -0877 Fax: (305) 660 -0878 Emali: Lcom Attn: Jason Mohammed CRB Geological & Environmental Services 4673 Ponce de Leon Boulevard Coral Gables, FL 33146 Fax (305) 567 -2853 Phone: (305) 447 -9777 Project CNR539 -05 Customer ID: CRBG50 Customer PO: Received: 03106/0610:25 AM EMSL Order. 170601748 EMSL Proj: Analysis Date: 3R/2006 Report Date: 3/15/2006 Asbestos Analysis of Bulk Materials via EPA 600 /R- 93/116 Method using Polarized Light Microscopy Sample Location Appearance % Non - Asbestos Fibrous % Non - Fibrous Asbestos % Type 1A Plaster Beige <1% Hair 100% Non - fibrous (other) None Detected 170601748-0001 Min. Wool 30% Non -fibrous (other) None Detected Non- Fibrous Fibrous 25% Cellulose 100% Non - fibrous (other) None Detected Heterogeneous Non- Fibrous Homogeneous Homogeneous 1 B Plaster Beige <1% Hair 100% Non -fibrous (other) None Detected 1706017484002 Non- Fibrous Homogeneous 1 C Plaster Beige <1 % Hair 100°A Non -fibrous (other) None Detected 170601748-0008 Non- Fibrous Homogeneous 2A Cuing Tile White 45% Min. Wool 30% Non -fibrous (other) None Detected 17OW174"004 Fibrous 25% Cellulose Heterogeneous Tan 100% Non -fibrous (other) None Detected 2B Calling Tile White 45% Min. Wool 30% Non -fibrous (other) None Detected 17060174844 Fibrous 25% Cellulose 100% Non - fibrous (other) None Detected Heterogeneous Non- Fibrous 2C Calling Tile White 45% Min. Wool 30°x6 Non - fibrous (other) None Detected 1706D1748-0006 Fibrous 25% Cellulose Heterogeneous 3A Floor Tile Tan 100% Non -fibrous (other) None Detected 170601748 -OW7 Non-Fibrous Homogeneous 3A -1 Mastic Yellow 100% Non - fibrous (other) None Detected 170601748m16 Non- Fibrous Homogeneous Analyst(s) Edger Rodriguez (30) �+ 0 E. Kimberty Wallace or other approved signatory Due to magnification limitations Inherent In PLM, asbestos fibers In dimensions below the resolution capabllity of PLM may not be delectat Samples reported as <1% or none detected may require additional testing by TEM to cmflrtn asbestos quantities The above test report relates only to the Items tested and may not be reproduced In arty form without Ute errpreas writisn approval of EMSL AnelocEd, Inc EMSUa Ilabllity Is limited to the cost of analysis EMSL bears no responsibility for sample collection aetMtles or analytical method limitations. interpretation and use of teat results are the responalbllity of the dlent Analysis performed by EMSL Miami (NVLAP Code 2002040) EMSL Analytical, Inc. 19501 NE loth Ave. Bay A, N. Miami Beach, FL 33179 Phone: (305) M -0577 Fax (30S) 6150-0 S78 Email: miamilab/8iema1.eom Attn: Jason Mohammed Customer ID: CRBG50 CRB Geological & Environmental Services Customer PO: 4573 Ponce de Leon Boulevard Received: 03/06/0610:25 AM Coral Gables, FL 33146 EMSL Order: 170601748 Fax (305) 567 -2853 Phone: (305) 447 -9777 EMSL Proj: Project: CNR539 -05 Analysis Date: 3/7/2006 Report Date: 3115/2006 Asbestos Analysis of Bulk Materials via EPA 600/R- 93/116 Method using Polarized Light Microscopy Non - Asbestos Asbestos Sample Location Appearance % Fibrous % Non - Fibrous % Type 3A -2 Floor Tile White 100% Non- fibrous (other) None Detected 170601748-0017 Non - Fibrous Homogeneous 3A -3 Mastic Yellow <1% Cellulose 100% Non -fibrous (other) None Detected 170601748-0018 Non- Fibrous Homogeneous 3A-4 FloorTBe Brown 97% Non - fibrous (other) 3% Chrysotlle 170601748-0019 Non- Fibrous Homogeneous 3B FloorTlle Tan 100% Non - fibrous (other) None Detected 170601748 -0008 Non - Fibrous Homogeneous 3B-1 Mastic Yellow 1000,1; Non- fibrous (other) None Detected 170601748-0020 Non- Fibrous Homogeneous 3B -2 Floor Tae White 100°/6 Non -fibrous (other) None Detected 170601748-0021 Non- Fibrous Homogeneous 3B-3 Mastic Yellow <1% Cellulose 100% Non - fibrous (other) None Detected 170601748-0022 Non- Fibrous Homogeneous 3B-4 FloorTtle Brown 97% Non -fibrous (other) 3% Chrysotile 170601748-0023 Non- Fibrous Homogeneous Analyst(s) Edgar Rodriguez (30) Kimberty Wallace or other approved signatory Due to magnification limitations Inherent in PLM, asbestos fibers In dimensions below the resolution capability of PLM may not be detected Samples reported as 0% or none detected may require additional testing by TEM to cmflrn asbestos quantities The above test report relates only to the Items tested and may not be reproduced In any form without the eowrapproval d responsibility Illabi s limited o the cost of analysis EMSL beers no responsibility for sample collection activltles or analyticel method limitations. interpretation and use or Analytical, reults ere the of the Analysis performed by EMSL Miami (NVLAP Code 200204-0) PLM -1 2 EMSL Analytical, Inc. 19501 NE 10th Ave. Bey A, M Miami Beach, FL 33179 Phone: (305) 650 -0577 Fax (305) 650 -0578 Email: miamilithammsl.eom Aft: Jason Mohammed CRB Geological & Environmental Services 4673 Ponce de Leon Boulevard Coral Gables, FL 33146 Fax (305) 567 -2853 Phone: (305) 447 -9777 Project CNR639 -05 Customer ID: CRBG50 Customer PO: Received: 03/08/0610:25 AM EMSL Order. 170601748 EMSL Pro]: Analysis Date: 3!712008 Report Date: 3115 /2006 Asbestos Analysis of Bulk Materials via EPA 600 /R- 931116 Method using Polarized Light Microscopy Non - Asbestos ebb stos Sample Location Appearance % Fibrous % Non - Fibrous % Type 3C FloorTOe Tan 100% Non -fibrous (other) None Detected 170601748•-0008 Non- Fibrous 170601746.0027 Homogeneous 3C -1 Mastic Yellow 100% Non - fibrous (other) None Detected 170601748-0024 Non - Fibrous 4A Homogeneous Tan 3C -2 Floor Tae White 100% Non -fibrous (other) None Detected 170601748-0025 Non- Fibrous Homogeneous 3C -3 Mastic Yellow 1705017480026 Non- Fibrous Homogeneous 100% Non - fibrous (other) None Detected 3CA FloorTlle Brown 97% Non -fibrous (other) 3°A Chrysotlle 170601746.0027 Non - Fibrous Homogeneous 4A FloorTOe Tan 100% Non - fibrous (other) None Detected 170601748-0010 Non - Fibrous Homogeneous 4A -1 Mastic Black 97% Non - fibrous (other) 3% Chrysotile 1706017480028 Non - Fibrous Homogeneous 4B FloorTlle Tan 100% Non -fibrous (other) None Detected 1706017480011 Non- Fibrous Homogeneous Analyst(s) Edgar Rodriguez (30) l Kimberly Wallace or other approved signatory Due to magnification limitations Inherent in PLM, asbestos fibers In dimensions below the resolution capability of PLM may not be detected Samples reported as <1% or none I detected may require additional testing by TEM to confirm asbestos quantities. The above test report relates only to the Items tested and may not be reproduced In arty form without the Iexpretions. tien � end use of tamest results scathes liability sponslbIs limited of the d ant of analysis EMSL bears no responsibility for sample collection activities or analytical method PLM -1 3 EMSL Analytical, Inc. 19501 NE 10th Ave. Bay A. N. Miami Beach, FL 33179 Phone: (306) 650 -0577 Far. (305) 6504879 Email mtiabfdtemel.eom Attn: Jason Mohammed Customer ID: CRBG50 CRB Geological & Environmental Services Customer PO: 4673 Ponce de Leon Boulevard Received: 03106/0610:25 AM Coral Gables, FL 33146 EMSL Order. 170601748 Fax (305) 567 -2853 Phone: (305) 447 -9777 EMSL Pro]: Project: CNR539 -05 Analysis Date: 3/7/2006 Report Date: 3115/2006 Asbestos Analysis of Bulk Materials via EPA 6001R- 931116 Method using Polarized Light Microscopy Non - Asbestos Asbestos Sample Location Appearance % Fibrous % Non - Fibrous % Type 4B-1 Mastic Black <1% Cellulose 97% Non - fibrous (other) 3% Chrysotile 1706017484029 Non- Flbrous Homogeneous 4C Floor Tfle Tan 100% Non - fibrous (other) None Detected 170801748-0012 Non-Fibrous Homogeneous 4C-1 Mastic Yellow <1% Cellulose 100% Non - fibrous (other) None Detected 17OW1748 -MO Non-Fibrous Homogeneous 5A Wallboard/Joint White 75% Cellulose 25% Non - fibrous (other) None Detected 170601748-0013 Compound Fibrous Heterogeneous 5B Wallboard Beige 20% Cellulose 80% Non -fibrous (other) None Detected 170601748-0014 Fibrous Heterogeneous 5C Wallboard/Joint White 35% Cellulose 65% Non -fibrous (other) None Detected 170801748-0015 Compound Fibrous Heterogeneous Analyst(s) Edgar Rodriguez (30) ' n Kimberly Wallace or other approved signatory Due to magnification limitations Inherent In PLM, asbestos fibers In dimensions below the resolution capability of PLM may not be detected Samples reported as <1 %or none detected may regtdre additional testing by TEM to eon8nn asbestos quantities. The above test report relates only to the Items tested and may not be reproduced In arty form without the a)resa written appmval of EMSL Analytical, Inc EMSL's liability Is limited to the coat of analysis. EMSL bears no responsibility for sample collection actMdes or analytical method limitations tnter"W on and use or test resulss ate the responsibility of the client. Analysis performed by EMSL Miami NVLAP Code 200204-0 PLM -1 THIS IS THE LAST PAGE OF THE REPORT. 4 ---_p j, 2- RZFFIT Ill'—", t7 ` Vol .., J1 pl\ ,.No 5 21 , ­E A ft-4 , ON N-O- t%;.r- ---_p j, 2- RZFFIT Ill'—", t7 ` Vol 311 1 4 •t5 Fi MIA MM ME, 6h .['rr 311 1 4 •t5 Fi MIA teorbcuas M I AM I-DADE b �pgjbq Florida Department of 4 4(�� S- �-S Minn: Dade oewN Air section Environmental Protection ' 13 S.W. 2nd Av&", Suite 9•Le3 Division of Air Resource Management M1arnm, fim & 33130-1530 IYPt OF NO ICL ( CHECK ONE ONLY) ❑ ORIGINAL ❑ REVISED ❑ CANCELLATION COURTESY 1 YPE OF PROIECT (CHECK ONE ONLY) ❑ DEMOLITION P&RENOVATION ❑ ROOFING IF DEMOLITION, WAS IT AN ORDERED DEMOLITION? - ❑ YES ❑ NO IF RENOVATION: File n IS IT AN EMERGENCY RENOVATION OPERATION? ❑ YES %NO IS IT A PPL+ANNEb RENOVATION OPERATION? NIYES O-NO Process #. ' 1 fac ihty N-n-me __ °1" �h� ►EQ- C -�1'1r Igo,? 1 �.D1�4 _ Address _ el O V 1r •City _— - - - -- /1�t� nn r Stateff z ,33w y�_Cou ry Site _ — = Consultant Inspecting Site Vlito _ Building Size _(Square Feet) # of floors Ags in Years — Prior Use. School /College/University - Residence final ess Other Present Use.. School/College /University Residence Small Business 11 Facility Owner �ON 'A S H 1 K Q J6 PJf Phone ( 30,'C_) $$1 — 6$ 51 _ Address ev ;27 o City � �19�/fi__ (rT A(3 t.�55 State Zip -3-31-46 111 Contractor's Name 4'PJS2 j��1!rsw_(LA!`�M��i'i�1L , i tJ G► Phone (q 1 )3%4:j-!0-Z7--6 Address City State Zip 73332y XNO Florida license No. 6 J G" ->S n ( Is the contract exempt from licensure under Section 469.004(7), F.S.? C3 YES IV Scheduled Dates: Asbestos Removal (mm /dd/yy) Start: 96 Finish: `4 b 06 Demo/Renovation (mm/dd/yy) Start: finish: V Procedures to be used (Check All That Apply): Strip and Removal Glove Bag Bulldozer Wreckin Ball Wet Method *Dry Method Explode Burn Down 'MUST OBTAIN PRIOR DERM APPROVAL BEFORE USING A DRY METHOD VI Piocedures for Unexpected RACM: jWl T ERti'+ I VII Asbestos Waster Transporter: Name Address O city X>MPAvJ° Vill. Waste Disposal Site: Name Address 3 Q OO J; jw City - -- 0°�¢�- A IX. Amount of RACM or ACM square feet surfacing material "ice linear feet pipe _ cubic feet of RACM off facility components _ square feet cementittous mat /rial 3�° _square feet resilient flooring J e-tAyft C­ - __square feet asphalt roofing X Fee Invoice Will Be Sent to Address in Block Below: (Print or Type) I certify that the above information is correct and that an individual trained in the provisions of this regulation (40CFR Part 61, Subpart M) will be on -site during the demolition or renovation and evidence that the required training has been accomplished by this pgrsQp will be availab %for inspection during normal business hoursi Jamtz;v'=U� tgnature of 04ner / Operator) 1ERM USE ONLY PostmarkJDatJ Received na �6 QS`f 34--)— ID # (Contact Phone #) c 1 r �� Alk COUNTY Department of Environmental Resources Management Miami - Dade County EEOS ID : 2006- WDM -PR -00692 DATE :04/25/2006 ADDRESS House Number Street Direction Street Name Street suffix City DESCRIPTION APPLICATION INFO Municipality South Miami DERMID 2006042514581124 Reference Process No.. NA X Number NA Project Name or Description SUSHI MAKI Subtype- NA Category Type NA Current Use of Property NA C/O Review Done ?. NA C/O Review Date NA C/O Tracking Closed'? NA C/O Reason for Closure (if applicable) NA West Dade Plan Review Summary 5810 -12 SW 72 ST SOUTH MIAMI TASK Review By Date Status Comments Plan Intake ILEANA MOLINA 04/252006 Plan Review Initial Core Review RAMONTORRECH 04/LB2006 Reviewed Sushi Bar expansion. NAME : 2006042514581124 FOLIO # : 09- 4036- 022 -0090 ASBES Review CRISTIAN GUERRERO 05101/2006 Approved Asbestos survey positive for VCT Abatement Notification on file with Air Div per FYI Final Core Review RAMON TORRECH 0501/2006 Overall Disapproval End of Process PENDING REVIEW DISAPPROVAL CODES Disapproval Code 01 0008 - Water 8 Sewer Verification Form Required Disapproval Code 02: 0047 - Requires Sewer Connection Approval as per EPA NO INVOICED FEES NO CONDITIONS 05/01/2006 Page 1 of 2 Core Reviewer Signature: Date : 05/01/2006 Page 2 of 2 Page 1 of 2 MIAM I•D/4DE ADA Coordination Agenda Coordination An in Public Places Audit and Management Services Aviation Building Code Compliance Building Business Development Capital Improvements Citizen's Independent Transportation Trust Communications Community Action Agency Community & Economic Development Community Relations Consumer Services Corrections & Rehabilitation Counlywide Healthcare Planning Cultural Affairs Elections Emergency Management Employee Relations Enterprise Technology Services Environmental Resources Management Fair Employment Practices Finance Fire Rescue General Services Administration 1111111111111111111111111111111111111111 2006050412210490 Department of Environmental Resources Management Office of Plan Review Services 11805 SW 26th Street • Suite 124 Miami, Florida 33175 -2474 T 786 - 315 -2800 F 786 - 315 -2919 Issued Date: 4 -MAY -2006 miamidade.gov Expiration Date: 2 -AUG -2006 MR ABE NA SUSHI MAKI MIAMI FL Tel- 975 -3774 Fax - (305) - RE: Sewer System Treatment and Transmission Capacity Certification Dear MR NA: The Miami -Dade County Resources Management application for app: connection to serve is more specifically project summary. Department of Environmental (DERM) has received your roval of a sewer service the following project which described in the attached Project Name: SUSHI MAKI Project Location: 5810 -12 SW 72 ST MIAMI Proposed Use: 2,000SF /11 SEAT RESTAURANT EXPANSION Previous Flow: 100 GPD Calculated Sewage Flow: 450 GPD Sewer Utility: MIAMI DADE WATER & SEWER DEPARTMENT Receiving Pump Station: 30 -0177 Historic Preservation Homeless Trust DERM has evaluated the request in accordance with Housing Agency the terms and conditions set forth in Paragraph Housing FinanceAuthodly 16 C of the First Partial Consent Decree (CASE Human Services No. 93 -1109 CIV- MORENO) between the United States Independent Review Panel of America and Dade County. DERM hereby Inlemational Trade Consortium certifies that adequate treatment and Juvenile Assessment Center transmission capacity, as herein defined, is Medical Examiner available for the above described project. Metropolitan Planning Organization Futhermore, be advised that this approval does not ParkgOrganization constitute Departmental approval for the proposed Planning and Zoning project. Additional reviews and approval may be Ponce required from sections having jurisdiction over Procurement Management specific aspects of this project. Also, be Property Appraiser advised that the gallons per day (GPD) flow Public Library System determination indicated herein are for sewer PubllcWorks allocation purposes only (in compliance with Safe Neighborhood Parks Consent Decree requirements) and may not be Seaport representative of GPD flows used in calculating Solid Waste Management connection fees by the utility providing the Slraleglc Business Management service. Team Metro Transit Urban Revitalization Task Force Vizcaya Museum and Gardens y� .LJ C Lr Ejv cc1 c;t cr_ �`l `Pr J .0 a Water and Sewer Paqe 2 of 2 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 2006050412210490 Issued Date: 4 -MAY -2006 Expiration Date: 2 -AUG -2006 Please be aware that this certification is subject to the terms and conditions set forth in the Sewer Service Connection Affidavit filed by the applicant, a copy of which is hereby attached. By copy of this certification we are advising the appropriate building official of our Department's determination. Sincerely, Carlos Espinosa, P.E. Director Department of E onmental Resources Management By: Ca os Hernand z, C ief, ffice o Plan Review Services Att' ents: cc: Building Official (w /Attachments) Utility Official (w /Project Summary Attachment) Date: 05 -04 -2006 Applicant's Name: MR ABE NA Applicant's Address: DERM Number: 2006 - 0504 - 1221 -0490 Project: SUSHI MAKI 5810 -12 SW 72 ST Proposed Use: 2,000SF/11 SEAT RESTAURANT EXPANS Pump Station: 30 -0177 Allocated flows: 450 (GPD) Projected NAPOT: 8.39 (HR) # Folio Lot Block Flow (GPD) - -- ---------- - - - - -- - -- - - - -- -------- - - - - -- --- ---------- - - - - -- - -- - - - -- -------- - - - - -- 1 09- 4036- 022 -0090 450 Page: 1 Date: 05 -05 -2006 Page: 1 Applicant's Name: MR ABE NA Applicant's Address: DERM Number: 2006 - 0504 - 1221 -0490 Project: SUSHI MAKI 5810 -12 SW 72 ST Proposed Use: 2,080SF/11 SEAT RESTAURANT EXPANS Pump Station: 30 -0177 Allocated flows: 498 (GPD) Projected NAPOT: 8.39 (HR) # Folio Lot Block Flow (GPD) - -- ---------- - - - - -- - -- - - - -- -------- - - - - -- --- ---------- - - - - -- - -- - - - -- -------- - - - - -- 1 09- 4036- 022 -0090 498 O 4 f Miami -Dade Water and Sewer Department INVOICE # 85016 New Business Office DATE- May 05, 2006 P.O Box 330316 PeopleSojt Acct lD# 0704557299 Miami, Florida 33133 -0316 3575 South LeJeune Road Room 114 Building Process #: X 2006163211 SERVE *CONSERVE Miscellaneous Charges CUSTID • 102387 —INACCOUNT WITH WRAPIDO CORPORATION 8005 NW 90TH ST MEDLEY, FL 33166— — REFERENCE W&S CC'S FOR ADDITION 1040 SQ FT W/11 SEATS FULL SERV REST, ER WATER. N/A REPLACING 1040 SQ FT RETAIL SPACE @ 5810 -12 SW 72 ST (TOTAL ER SEWER: N /A� 36 SEATS) FOLIO 09- 4036-022 -0090 DERM # 2006050412210490 DATED 05/04/06 EX PS# 1919888200 CK# 5596 AGMT ID: i — DESCRIPTION QNTY /GPD DESCRIPTION DIST CODE UNIT PRICE AMOUNT 498 jConn Chg - WASD Water –_ NWT -CIF1 1 1.39 — $692.22 498 _ 'Conn Chg - WASD Sewer NWW -CIF1 i 5.6 $2,788.80 1 Verlf Form- non -res exist'g (Water) �Verif NWT -VF03 75 $75.00 1 Form- non -res exisrg (Sewer) — NWW -VF03 751 TOTAL: i $75.00 $3,631.02 WATER DEPOSITS: $0 00 - -- SEWER DEPOSITS - ; $0.00 1 INVOICE NO. 85016 TOTAL: 201t£91£f 96SS :(S)1 H33HO 20'1£9'£1 1d101 20'1£9'£1 GH N31 H03HO 112E91tMe V8501# gggAen 51512006 9:47:52 AM By: YMART ££00S0W ribjA690Wd5NWdpmer, Yellow-General Office, Pink -Local Office, Gold -New Business Al ld8iN30 1ED N9N a3AI938 6101 9H2/90/S0 1N3 ISW30 9NI41U18 I fLonq nnun tiweu $3,631.02 0 MIAMI -DADE ME VERIFICATION FORM EXPIRES ONE YEAR FROM DATE ON FORM SERVE-CONSERVE ATLAS PAGE' M -19 INV #. 85016 FORM #. 20069374 DATE' 5/5/2006 NAME OF OWNER' SUSHI MAKI PROPERTY ADDRESS 810-1 SW 72 ST — PROPOSED USAGE / 1040 SQ FT /11 SEAT RESTAURANT EXPANSION NO OF UNITS: -- - -- — REPLACES: PREVIOUS 1040 SQ FT RETAIL SPACE USAGE / NO. OF UNITS. _ J PROPERTY LEGAL' I A LARKINS PB 3 -198 LOTS 11 & 12 LESS N24FT & LOTS 13 & 14 LESS N30FT FOLIO NUMBER' 091036 -022 -0090 GALLONS PER DAY INCREASE: 498 PREVIOUS FLOW: 52 PREVIOUS SQUARE FOOTAGE: 1,040 ❑ NEW CONSTRUCTION PROPOSED FLOW. 550 PROPOSED SQUARE FOOTAGE: 1,040 INTERIOR RENOVATION THIS IS TO CERTIFY THAT THE MIAMI -DADE WATER AND SEWER DEPARTMENT DOES HAVE A(N) _12_ INCH WATER MAIN ABUTTING THE SUBJECT LEGALLY DESCRIBED PROPERTY. WE ARE WILLING TO SERVE THE SUBJECT PROPERTY, (OR, IF "WILL HAVE ", UPON PROPER CONVEYANCE AND PLACEMENT INTO SERVICE OF WATER FACILITIES BY THE DEVELOPER UNDER AGREEMENT WITH DEPARTMENT, (AGREEMENT ID # N /A) SUBJECT TO PROHIBITIONS OR RESTRICT16NS OF GOVER ENTAL AGE CIES HAVING JURISDICTION OVER MATTERS OF WATER SUPPLY OR WITHDRAWAL Yoanet Martinez - BY: — / — SIGNATURE ,61F REPRESENTATIVE REVIE AUTHORIZED BY 5D.A2C - - - - - - -- - - - - CRITERIA: C THIS IS TO CERTIFY THAT THE MIAMI -DADE WATER AND SEWER DEPARTMENT DOES HAVE A(N) _8_ INCH GRAVITY SEWER MAIN ABUTTING THE SUBJECT LEGALLY DESCRIBED PROPERTY. WE ARE WILLING TO SERVE THE SUBJECT PROPERTY, (OR, IF "WILL HAVE ", UPON PROPER CONVEYANCE AND PLACEMENT INTO SERVICE OF SEWER SEWER FACILITIES BY THE DEVELOPER UNDER AGREEMENT WITH THE DEPARTMENT, (AGREEMENT ID # N/A). SUBJECT TO PROHIBITIONS OR RESTRICTIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER MATTERS OF SEWAGE DISPOSAL. FURTHERMORE; - APPROVAL OF ALL SEWAGE -FLOWS INTO THE -DEPARTMENTS -SYSTEM - MUST BE OBTAINED F OM D.E.R.M. THE ANTICIPATED DAILY WATER AND /OR SEWAGE FLOW FOR THIS PROJECT WILL BE: FOUR HUNDRED NIN?,TY EIGHT [498) GALLONS PE �2 DAY INCREASE. BY S GNATURE OF NEW BU SS COMMEN PLANS REVIEW COMMENTS: Yoanet Martinez - ATfa/E AUTHORIZED BY JECT TO D.E.R M. SEWER ALLOCATION LETTER DATED: 514106 # 2006050412210490 CONTACT NAME ABE Pnnted On* 5/5/2006 NB: Yoanet Martinez 10 19 45 AM PR, CONTACT PHONE. (305) 975 -3774 EXST ACCT #1919888200 WCC 692 22 SCC 2788 80 PAID ACCT #0704557299 >S COM ENTS: f E W COMMENTS: CRITERIA: C THIS IS TO CERTIFY THAT THE MIAMI -DADE WATER AND SEWER DEPARTMENT DOES HAVE A(N) _8_ INCH GRAVITY SEWER MAIN ABUTTING THE SUBJECT LEGALLY DESCRIBED PROPERTY. WE ARE WILLING TO SERVE THE SUBJECT PROPERTY, (OR, IF "WILL HAVE ", UPON PROPER CONVEYANCE AND PLACEMENT INTO SERVICE OF SEWER SEWER FACILITIES BY THE DEVELOPER UNDER AGREEMENT WITH THE DEPARTMENT, (AGREEMENT ID # N/A). SUBJECT TO PROHIBITIONS OR RESTRICTIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER MATTERS OF SEWAGE DISPOSAL. FURTHERMORE; - APPROVAL OF ALL SEWAGE -FLOWS INTO THE -DEPARTMENTS -SYSTEM - MUST BE OBTAINED F OM D.E.R.M. THE ANTICIPATED DAILY WATER AND /OR SEWAGE FLOW FOR THIS PROJECT WILL BE: FOUR HUNDRED NIN?,TY EIGHT [498) GALLONS PE �2 DAY INCREASE. BY S GNATURE OF NEW BU SS COMMEN PLANS REVIEW COMMENTS: Yoanet Martinez - ATfa/E AUTHORIZED BY JECT TO D.E.R M. SEWER ALLOCATION LETTER DATED: 514106 # 2006050412210490 CONTACT NAME ABE Pnnted On* 5/5/2006 NB: Yoanet Martinez 10 19 45 AM PR, CONTACT PHONE. (305) 975 -3774 2008016318095308 MIAMI-DAD PERMIT NO: GDO- 002924- 2006/2008 (IGT)- IGT /AGT SIISHI MAKI RESTAURANT 5812 SW 72 ST SOUTH MIAMI, FL 33134- PERMITTER: Mr. Abe Ng WRAPIDO CORPORATION D /B /A SIISHI MAKI RESTAURANT 2614 PONCE DR LEON BLVD CORAL GABLES, FL 33134- GREASE DISCHARGE ANNUAL OPERATING PERMIT DESCRIPTION OF FACILITY /EQUIPMENT Environmental Resources Management Water & Wastewater Division 33 SW 2nd Avenue • 5th Floor Miami, Florida 33130 -1540 T 305 - 372 -6524 F 305 - 372 -6631 miamidade.gov This document, issued under the provisions of Chapter 24, Miami -Dade County Code (Miami -Dade County Pollution Control Ordinance), shall be valid from 15 -JAN -2006 through 14 -JAN -2008. The above named permittee is hereby authorized to operate the pollution control facility at the above location which consists of the following: Eating establishment facility(ies) with 28 seats, one 950 gallon grease interceptor(s) and appurtenances with effluent discharge to sanitary sewer. This facility is subject to conditions listed below and in the following pages (if any) of this permit. SPECIFIC CONDITIONS 1. Grease interceptors and /or grease recovery units shall be of a type and capacity approved by the Chief Plumbing Official (or State of Florida for Miami -Dade County Public Schools) that are accessible for cleaning, maintenance, inspections and sampling. The installation of grease pretreatment devices shall comply with requirements of DERM Plans Approval Process. No grease intercetor or recovery unit shall be altered in any way that reduces, or eliminates the grease retention capacity it was designed to operate by. During business hours the grease pretreatment system shall be operating as designed except when the unit(s) is(are) temporarily out for repair. 2. Grease interceptors and /or grease recovery units shall be maintained in proper operating condition by periodic removal of accumulated wastes. Total content of each interceptor shall be removed by a certified liquid waste transporter and disposed of at an approved facility, at minimum, 2 times per year. Total content of each grease recovery unit shall be properly disposed of. No liquid waste shall be discharged from the interceptor to the sanitary sewer system in ways other than that approved by designed means. Receipts of disposal shall be kept for one year and made available to DERM upon request. Each grease pretreatment system shall be accessible at normal operating hours, or at reasonable times for compliance and /or sample inspections. Effluent discharge shall not exceed 100 milligrams per liter as a grab sample, or 50 milligrams per liter as a daily average for Oil & Grease, nor be less than 5.5, nor - greater than 9.5 for pH. Effluent discharge to the sanitary sewer system shall not exceed the Miami -Dade County Sewer Discharge Standard. An accessible sample point shall be provided and maintained on the discharge side of the interceptor(s) and /or recovery unit(s) where no further treatment has been determined to occur. The outlet tee of each interceptor shall extend to within eight (8) inches of the tank bottom. No grease pretreatment system shall be the cause of, or maintain a sanitary nuisance condition, or groundwater contamination from leakage, overflows or line deficiencies. No pretreatment system shall maintain a condition that allows groundwater infiltration or stormwater inflow. No inflow of water, or wastewater shall be introduced into a pretreatment system by indirect disposal, clean -outs, pumps and hoses, or by any other means other than the inlet pipe on plans approved by Miami -Dade County 71a tmeat of 2nmen7tal Reso es Management - John W. Renfr P.B., Director Page 1 of 2