06-1375-001PLAN
J J
♦ J
� a J
AND FREEZERS
MED, TEMP, 240____-
BY ARCTIC INDUSTRIES INC.
a_
SECTION TYP.
N.T.S.
A -HEAVY DUTY CAM -LIFT HINGES
B- HYDRAULIC DOOR CLOSER
C- THERMOMETER
D -LIGHT SWICH.W /INT. SAFETY (NITS) [LIGHT
E -KEYED LATCH W /INT. SAFETY RELEASE
F -36" DIAMOND TREAD PLATE INT. & EXT.
I OF" I M Im,
,
w�Qa"r.,B"i
® WALK -IN
COOLERS
AND FREEZERS
MED, TEMP, 240____-
BY ARCTIC INDUSTRIES INC.
loft
9731 N. W.
114 Warr Miami F f or I da 33178
AMPS.,
EVAP _1 15 __ V.
_ 4_2 __
AMPS.
S P E C
I F I C A
T I O N
S
OVERALL SIZE: Width_
6'8" __xlength_5_8
___xHeight_
91211
INS TALLA TION
CHEMICALS FOUND IN CONCRETE BY— PRODUCTS. PETROLEUM BASED PROTECTION
MUST BE APPLIED BETWEEN CONCRETE AND THE METAL SURFACES. (LIQUID TAR,
INSIDE INSTALLATION
CONSTRUCTION
N. S. F, CONSTRUCTION
INSULATION Thickness 4"
Type: Polystyrene Flame Spread 15
FLOOR NO FLOOR
SCREED SUPPLIED
INTERIOR FINISH EXTERIOR FINISH
26 GA GALVALUME /ACRYLUME 26 GA GALVALUME /ACRYLUME
WALK —IN DOORS '
(FLUSH MOUNTED DOOR)
KEYED LATCH CAM LIFT HINGES
INSIDE SAFETY RELEASE HYDRAULIC DOOR CLOSER
VAPOR PROOF LIGHT THERMOMETER
LIGHT SWITCH DOOR KICKPLATES
ACCESSORIES
RE'FRIGE'RATION
COOLER
3/4
H,P,
MED, TEMP, 240____-
V. _ 1__
PH,
COND, -
8.0--
AMPS.,
EVAP _1 15 __ V.
_ 4_2 __
AMPS.
C ll TECUMSEH AKA9470 EXDXE COND,
(l) CLIMATE CONTROL TLC076 EVA,
REFRIGERATION IS REMOTE OUTDOOR
(1) UL STANDARD OVER
AIR COOLED
(ll UL COMPRESSOR STAND
PLEASE NOTE
IMPORTANT
NOTICE TO GENERAL CONTRACTOR AND SUB — CONTRACTOR. FOR QUARRY
TILE OR CONCRETE WEARING FLOORS, THE METAL FACINGS MAY BE SUS-
CEPTIBLE TO STAINING DUE TO EXCESSIVE MOISTURE CREATED BY HYDRA-
TION OF CONCRETE —TYPE MATERIALS. IT IS ESSENTIAL THAT EACH ROOM
BE PROPERLY VENTILETED. SPECIAL PRECAUTIONS MUST BE TAKEN WHEN
USING MURIATIC ACID DUE TO EFFECTS OF ACID FUMES ON ALUMINUM AND
STAINLESS STEEL.
IN ADDITION, METAL SURFACES MUST BE PROTECTED FROM LIME AND OTHER
CHEMICALS FOUND IN CONCRETE BY— PRODUCTS. PETROLEUM BASED PROTECTION
MUST BE APPLIED BETWEEN CONCRETE AND THE METAL SURFACES. (LIQUID TAR,
BRUSHED OR SPRAYED ABOVE THE CONCRETE CONTACT LINE, HEAVY EPDXY PAINT,
8 MIL POLYETHLYLENE H.D. BLACK DOUBLE LAYERED, 30 LB. ASPHALT IMPREGNATED
ROOFING PAPER).
Corners
Ceilings Floors Sills
Doors
Walls transoms Total
scale 1
4= 1'
Drawn By JORGE GARCIA
Date 7Z21/2006
P.0
Approved By JANET
Job No.
4 "N.S.F COOLER NO FLOOR
Q60909
DISCOUNT EQUIP. INT'L /PRIDE
Drawing No.
SUSHI MAKI
Q60909