05-437-018CONC. BLOCK WALL 1 5 CONT 8� 2' -6' ° ao ° N Lu TmDBL. W.Wr_. 5 0 48' VERT. IN GROUTED CELL SECTION AT EDGE OF SLAB SCALE: 3/4 " =1' -0" VERT. REINF. (SEE NOTE.) CONCRETE COLUMN SCHEDULE MARK SIZE VERT. REINF. TIES REMARKS TC 8'x12' 4% 0308' F -3 TC -1 8'x16' 416 0308' TC -2 8'x24' 65 0308' 4 #5 TC -3 8,x16'xib' 65 0308' 12" TC -4 8'x30' 65 0308' GRADE a , 03 0 8' WATERPROOF MEMBRANE A 8'x28' 405 0308' Z B 8'X30' 45 0308' DOWELS 41 (SAME SIZE & SPACING C 24' X 24' 6 0T 03 0 at conc, block col D 24' X 16' 4% 03 0 16 cons, block col E 8'x28' 45 0308' ■ F 8'X III XS' 6 5 0308' 24" X 12" G 10' X 12' 4% 03 0 8' n V) 40" X 12" 4 #5 CONT. 1 #4 0 16" TRANSV. TYPICAL WALL FOOTING DETAIL 8" TYPICAL THICKENED EDGE N. T. S. 2' -6' 4 -03 TIES EA TIE SK AS INTERSECTION --1L 8' —1— 4" CONC. SLAB 2 -5 CORER BARS, 30' 7 OWN BOTT� TOP, ONE M N TYPICAL OX12 CONC. TIE BEAM N TIE 5M. REINF. AT INTERSECTION SCALE: 3/4' = 1' -0' A0509\sftd%%4AMV, 4/8!M 9:16:16 AM F 18' 8' TC -3 CLEANOUT OPENING 2 #9 WIRE REINF. MARK (GROUT AFTER INSPECTION (DUR -O -WALL) OR m TYP. 0 ALL LEVELS & APPROVED EQUIV. F -3 BASE OF ALL CELL LADDER TYPE. Li GROUTING HIGHER THAN 4' -0 ") In 1/2- EXP. JT. PROVIDE 1 1/2" DEEP KEY AT ao 4 #5 POINTS WHERE GROUTING IS F -5 TOP OF FIN. FLOOR STOPPED 12" 5# 5 CONC. SLAB (SEE PLAN) GRADE a , F -4X6 WATERPROOF MEMBRANE 16" 7 # 5 LW 14 #5 SW COMPACTED FILL ao Z 2 #4 (TYP.) NOT SHOWN ELSEWHERE C FOOTING (SEE FND. PLAN) DOWELS 41 (SAME SIZE & SPACING ° a COMPACTED SOIL AS WALL REINF.) #7 0 6" TOP & BOTT. #4 0 24" TRANSV. 3" CL. V) i� TRANSV. REINF. WF -16 x (SEE SCHED.) TYPICAL WALL FOOTING DETAIL 8" TYPICAL THICKENED EDGE N. T. S. 2' -6' 4 -03 TIES EA TIE SK AS INTERSECTION --1L 8' —1— 4" CONC. SLAB 2 -5 CORER BARS, 30' 7 OWN BOTT� TOP, ONE M N TYPICAL OX12 CONC. TIE BEAM N TIE 5M. REINF. AT INTERSECTION SCALE: 3/4' = 1' -0' A0509\sftd%%4AMV, 4/8!M 9:16:16 AM F 18' 8' TC -3 WOOD TRUSSES 0 24' O:C. TRUSS ANCHOR SEE CONNECTOR SCHEDULE A' COX. PLYWOOD SHEATHING W 180 COMMON NAILS 06' OZ. F. EDGES 4 PERIMETER OVERHANG 2' -0' TB. 8' CONC. BLOCK ROOF TYP. SECTION SCALE: I'- 1' -0' STRUCTURAL NOTES: COORDINATION: - COORDINATE ALL DIMENSIONS, ELEVATIONS 4 OPENINGS WITH ARCHITECTURAL DRAWINGS. REPORT ANY DISCREPANCIES TO OUR OFFICE. CONCRETE: - COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON FILL: 2500 PSI ALL OTHER POURED -N -PLACE CONCRETE: 3000 PSI GROUT: 3000 PSI -TEST: A MIN. OF 5 CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 50 CU. YD. OR PORTION THEREOF SPECIMENS SMALL BE TESTED ACCORDING TO A.S.TM. C -3% ONE AT 3, ONE AT 1, AND 3 AT 28 DAYS. - COVER: CONCRETE DEPOSITED AGAINST THE GROUND: 3' FOF41ED CONCRETE IN CONTACT WITH THE GROUND:_2' BEAMS AND COLUMNS: 1 -1/1' INTERIOR SLABS: 3/4' EXTERIOR SLABS' 1 -1/2' POST- TENSIONED SLABS: 1' SLAB ON FILL: (PLACED ACCORDING TO ACI 302) - JOINTS: ISOLATION JOINTS MUST BE USED AT JUNCTIONS WITH WALLS AND COLUMNS, USE 1/2' THICK PREMOLDED JOINTS FULL DEPTH OF SLAB. CONTROL JOINTS PLACED AT CENTERLINE OF COLUMN LINES PROVIDE INTERMEDIATE JOINTS IF COLUMN SPACING IS GREATER THEN 30' IN SIDEWALKS PROVIDE TOOLED JOINTS SPACED AT INTERVALS EQUAL TO THE WIDTH OF THE SLAB. 4' 4 5' SLABS: I' DEEP TOOLED JOINTS MUST BE SAWED BEFORE 24 HOURS AFTER CONCRETING. CONSTRUCTION JOINTS MUST BE PLACED N THE SLAB WHERE BUILDING EXPANSION JOINTS ARE SHOWN AND WHERE CONTROL JOINTS ARE SHOWN. WHEN CONCRETING AND OPERATING ARE CONCLUDED FOR THE DAY, CONSTRUCTION JOINTS SHALL BE FORMED WITH BURKE KEYED KOLD METAL JOINT FORM OR APPROVED EQUAL. -VAPOR BARRIERS: WATERPROOF MEMBRANES (OVERLAPPED 6' AT JOINTS) WITH A PERMEANCE OF LESS THAN 03% PERMS IN ACCORDANCE WITH A.S.TM. E -98 SHALL BE PROVIDED UNDER INTERIOR SLAB. WHERE NO VAPOR BARRIER IS USED THE SUBGRADE MUST BE DAMPENED WITH WATER IN ADVANCE OF CONCRETING NO FREE WATER STANDING ON THE SUBGRADE NOR ANY MUDDY OR SOFT SPOT IS PERMITTED. -ANY STRUCTURAL MEMBER PENETRATING SLAB ON FILL IS TO BE IR' PRE- MOLDED JOINT FILLER COMPLYING WITH AS.TM. D -1152, TYPE I. - FINISHING: NO PREMATURE FINISHING SHALL BE ALLOWED. IMMEDIATE FOLLOWING FLOATING TROWELING WITH STEEL 'TROWELS SHOULD BE COMMENCED IF REQUIRED BROOMING SHALL BE AFTER THE STEEL TROWELING OPERATION. -SLAB FINISHES: (UNLESS OTHERWISE NOTED BY THE ARCHITECT) BUILDING: STEEL TROWELED OUTSIDE SLAB: -BROOMED REINFORCING STEEL: - REINFORCING BARS CONFORMING TO AS.TM. A -815 GRADE 60, INCLUDING COLUMN AND BEAM TIES. - WELDED FIRE FABRIC CONFORMING TO AS.TM. A -185 AND SUPPORTED ON SLAB BOLSTERS SPACED AT 3' -0' O /C. - FABRICATION AND DETAILING ACCORDING TO A.C.I.-315. -ALL ACCESSORIES TO HAVE UPTURNED LEGS AND BE PLASTIC DIPPED AFTER FABRICATION. WELDING: -ALL WELDING SHOULD BE PEWDRMED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH BY AIDS. BY CERTIFIED WELDERS. - CONTRACTORS TO USE E -10 SERIES LOW HYDROGEN ELECTRODES. DESIGN CRITERIA: SUPERIMPOSED LOADS LIVE LOAD: DEAD LOAD: - ROOF: 30 PSF 25 PSF -FLOOR 40 PSF 50 PSF WIND LOAD: V -146 MPH EXP. C, IF. -1, KD-I NER ARCHITECT. AND CONTRACTOR NOTE: -CHECK FOR SHOP DRAWINGS AND INSPECTIONS OF REINFORCEMENT IN THE FIELD ARE REQUIRED IF THIS OFFICE IS TO BE HELD RESPONSIBLE FOR THE STRUCTURAL. ADEQUACY OF THE CONSTRUCTED BUILDING. -ALL SHORING, RE- SHORING AND TEMPORARY BRACING REQUIRED IN THIS PROJECT IS TO BE DESIGNED BY FLORIDA RESTRICTED ENGINEER WHO SPECIALIZES N FORM WORIQTEMPORARY BRACING DESIGN. AND WHO HAS BEEN HIRED BY THE GENERAL CONTRACTOR THE GENERAL CONTRACTOR IS THE ULTIMATE RESPONSIBLE PARTY FOR SHORING, RE- SHORING, AND TEMPORARY BRACINCs REQUIRED ON THIS PROJECT AND MUST SATISFY HIMSELF WITH THE ADEQUACY OF THE INSTALLATION OF THESE ITEMS AT ALL TIMES. IN THE SPECIFIC CASE OF POURED SLABS IT IS HIGHLY RECOMMENDED THAT FROM THE SHORING DESIGNER OR HIS AGENT PRIOR TO THE PLACEMENT OF CONCRETE THE GENERAL CONTRACTOR SECURE A CERTIFICATION OF THE INSTALLED SHORING. FETY OSHA AND LABOR LAWS. -THE STRUCTURAL ENGINEER OF RECORD DOES NOT POSSES, NOR PRESUMES TO POSSES ANY KNOWLEDGE OR EXPERTISE IN MATTERS TO JOB SITE EMPLOYEE SAFETY, OSHA OR LABOR LAE REQUIREMENTS FOR A CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS ARE THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THOSE CONSULTANTS HE HIRES TO ADDRESS THESE MATTERS. THE STRUCTURAL ENGINEER OF RECORD SPECIALIZES IN STRUCTURAL DESIGN ONLY, AND THE BOARD OF PROFESSIONAL REGULATION FORBIDS HIM FROM ASSUMING RESPONSIBILITY OUTSIDE HIS AREA OF EXPERTISE 'PLICABLE CODES: - ALTHOUGH T14E ENGINEER OF RECORD HAS STRIVED TO MEET ALL APPLICABLE CODES AND LOCAL ORDINANCE REQUIREMENTS, THE CONTRACTOR IS STILL RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND ORDINANCES OF THE EVENT OF CONFLICT OR OVERSIGHT N THE DRAWINGS THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER OF ANY CONFLICT OF DISCREPANCY ENCOUNTERED SO THAT APPROPRIATE REMEDIES MAY BE UNDERTAKEN. -THE APPLICABLE CODES ARE: FLORIDA BUILDING CODE A.C.I. 318 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. A.IS.C. MANUAL OF STEEL CONSTRUCTION, 9th EDITION. ASCI 98 SHOP DRAWING SUBMITTALS: - SUBMIT ONE SEPIA AND ONE PRINT OF ALL SHOP DRAWINGS LISTED BELOW. IF SIGNED AND SEALED SHOP DRAWINGS ARE REQUIRED, THEN SUBMIT TWO ADDITIONAL SIGNED AND SEALED PRINTS FOR APPROVAL. -SHOP DRAWINGS: REINFORCED STEEL. STRUCTURAL STEEL. CONCRETE MIX DESIGN. TIMBER B- ALL ROOF MEMBERS TO BE SECURED TO TIE BEAM OR OTHER STRUCTURAL ELEMENT WITH HURRICANE ANCHORS. C- TRUSS MANUFACTURER TO SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY HIS REGISTERED ENGINEER BEFORE SUBMITTING FOR APPROVAL. MASONRY NOTES: (TYPICAL FOR ALL LEVELS) _ I. ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASOORY BLOCK MANUFACTURED IN CONFORMANCE WITH ASTM C -90 AND PROJECT SPECS. THESE MASONRY UNITS SHALL PROVIDE A MINIMUM PRISM STRENGTH F'm= 1500 PSI IN 28 DAYS AS - - - - DELIVERED TO THE JOB SITE. MANUFACTURER SHALL SUBMIT PRISM TEST RESULTS FOR ALL MASONRY USED ON TINE PROJECT PRIOR TO CONSTRUCTION. THREE PRISMS SHALL BE MADE FOR EACH TEST OF 5000 SQ. FT. OF WALL. PRISMS SHALL BE TWO BLOCK NIGH, USING TYPE M MORTAR ON FACE SHELL ONLY AND MADE TESTED N CONFORMANCE WITH A.S.T.M. C 140 -90, TOGETHER WITH A.S.T.M. E 441. METHOD B AS MODIFIED N ACI 530.1 92. MASONRY UNIT STRENGTH - 1900 PSI 2. ALL GROUTING SHALL COMPLY WITH ASTM C -416 WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS. MIX SHALL HAVE 3/8' MAX. SIZE AGGREGATE WITH A MINIMUM SLUMP OF 8'. GROUT SHALL BE SAMPLED AND TESTED AS PER ASTM C -39, WITH A MR OF 3 TESTS PER 30 YD. OR LESS BEING PLACED EACH DAY. 3. TYPE M MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT AND PROPORTIONED AS OUTLINED UNDER ASTM C -210. HOLLOW UNITS SHALL BE LAID WITH RILL MORTAR COVERAGE ON HORIZONTAL AND VERTICAL FACE SHELLS EXCEPT THAT WEBS SHALL ALSO BE BEDDED IN ALL COURSES OF COLUMNS, IN THE STARTNG COURSE ON FOOTINGS AND SOLID FOUNDATION WALLS, AND AT GROUTED CELLS. HORIZONTAL AND VERTICAL FACE JOINTS SHALL BE 3/8' THICKt U.ON. VERTICAL JOINTS SHALL BE SHOVED TIGHT. MORTAR PROTRUSIONS EXTENDING INTO CELLS OR CAVITIES (THAT ARE TO BE REINFORCED AND GROUTED) SHALL BE REMOVED. ALLOW MIN. 24 HOURS FOR MORTAR TO CURE PRIOR TO GROUTING 4. STANDARD HIGH -LIFT GROUTING PROCEDURES SHALL BE FOLLOWED. LAY UP BLOCK AS REQUIRED. DROP VERTICAL STEEL INTO CELLS CONTAINING DOWELS AND SECURE IN PLACE. PROVIDE CUTOUT ON FACE FOR CLEAN OUT, STEEL TYING AND INSPECTING, AND GROUT FLOW VERIFICATION. GROUTING SHALL BE DONE IN MAX. OF 4' -0' LIFTS, CONTINUING AROUND BUILDING AND RETURNING TO THE STARTING POINT WITH APPROXIMATELY ONE HOUR DELAY PRIOR TO COMMENCING WITH NEXT 4' -0' GROUT LIFT. GROUTING SHALL BE CONTINUOUS UNTIL COMPLETION. THE LEVEL OF GROUT SHALL BE STOPPED 1 -1/1' FROM TOP OF THE LAST MASONRY UNIT. WHERE BREAK AWAY OR BREAK OUT IS CALLED FOR OR REQUIRED, A SAW CUT SHALL BE USED. FOLLOW ABOVE PROCEDURE TO ROOF LEVEL. 5. ALL WALLS SHALL BE REINFORCED AND GROUTED VERTICAL AND HORIZONTAL CONTINUOUS AS SHOWN ON DRAWINGS. ALL WALL OPENINGS SHALL HAVE A MIN. OF 2 0 5 VERTICAL EA SIDE AND 2 0 5 TOP AND BOTTOM(U.OA ON PLANS AND SCHEDULES). ALL SPLICING IN REINFORCING BARS SHALL BE A MIN. LAP OF 6 X BAR NUMBER MASONRY CONTRACTOR SHALL PROVIDE 'LADUR' TYPE 'DUR -O -WALL' HORIZONTAL REINFORCING AT ALTERNATE COURSE I6' C/C UDA DUR -O -WALL SHALL BE CONTINUOUS WITH A MIN. SPLICE OF 6'. PROVIDE PREFAB TEES AND CORNER SECTION AS REQUIRED. ALL LINTEL REINFORCING BARS SHALL EXTEND NOT LESS THAN 24' BEYOND EA SIDE OF ALL OPENINGS. 6. MASONRY CONTRACTOR SHALL LAY BLOCK UNITS SO AS TO ASSURE TIGHT HEAD JOINTS AND SNUG BED JOINTS FOR SHRINKAGE CONTROL AND WATER TIGHTNESS. MORTAR JOINTS SHALL BE TOOLED WHEN THUMB PRINT HARD TO INCREASE WATER TIGHTNESS. ALL ADJUSTMENTS TO BLOCKS NOTED ON PLANS SHALL BE SAW CUT. WHERE BREAK AWAY OR BREAK OUT IS CALLED FOR, A SAW CUT SHALL BE USED. 1. CONTRACTOR SHALL RETAIN THE SERVICES OF AN INDEPENDENT TESTING LAB TO PROVIDE TESTING IN CONFORMANCE TO PLANS AND SPECIFICATIONS. ALL TESTING SHALL BE PAID BY THE OWNER S. ALL MASONRY DESIGN AND CONSTRUCTION SHALL COMPLY WITH ACI 530 -92 AND ACI 530.1 -92 - PROVIDE 0 9 TRUSS TYPE (LADDER TYPE FOR REINFORCED MASONRY) HORIZONTAL MASONRY REINF. 0 16' O/C N ALL MASONRY WALLS - IN ALL VERTICAL REINFORCEMENT PROVIDE FOUNDATION DOWELS AND STANDARD HOOKS AT TOP TIE BEAM. - SPLICE VERTICAL MASONRY WALL REINFORCEMENT 48 BAR DIAMETERS AS FOLLOWS: FOR 0 5 BARS: 30' FOR 0 6 BARS: 36' FOR 01 BARS: 42' STRUCTURAL STEEL: -ALL STRUCTURAL STEEL PLATES SHALL CONFORM TO A.S.T.M. A -36 NOT DIPPED GALVANIZED. - PLATES SHALL BE TOUCHED AFTER WELDING HAS TAKEN PLACE. -ALL STRUCTURAL STEEL WELDING SHALL BE PERFORM WITH A.W.S. D.I.I. -ALL ANCHOR BOLTS SHALL CONFORM TO AS.T.I A -301. -ALL BOLTS SHALL CONFORM TO A.S.T.M. A -325. - ALL STRUCTURAL TUBING SHALL BE CONCRETE FILLED AND CONFORM TO A S. T. M. A -500, PROVIDE 1/4' DIA. PRESSURE RELIEF HOLES IN EACH COLUMN, AT TOP, BOTTOM AND MID -POINT. (FY- 46 K S. D - PROVIDE ONE SHOP COAT OF RUST INHIBITING PANT MIN. 3 ML. DRY FILM THICKNESS). - FABRICATIONS AND ERECTIONS SHALL BE DONE IN ACCORDANCE WITH THE LATEST A SPECIFICATIONS. FOUNDATION RECOMENDATION : ALL SOIL SUPPORTING FOUNDATIONS SHALL BE PREPARED AS RECOMMENDED BY 'ALL STATE ENGENIERNG 4 TESTING CONSULTANTS INC.' OF MIAMI, FLORIDA, TO PROVIDE AN ALLOWABLE BEARING CAPACITY OF 3000 "P. CERTIFICATION OF BEARING CAPACITY SHALL BE SUBMITTED BY A GEOTECHNICAL ENGINEER REGISTERED N THE STATE OF FLORIDA PRIOR TO POURING FOUNDATIONS _C f C.A. Nx 26217 16581 SW 64tH TER. MAW FLORIDA 33193 TeL 786.336.1082 Fax 954.441.8444 E-maA: NW S= a= W F I=- 3 pJ oa Sow 000 xwo �02 F- OUj w� Eom wNo �0m <IL O REVMIONS JBY 05 %,/2005 FOOTING SCHEDULE MARK SIZE m REINF. EA. WAY REMARKS F -3 3'- 0 "X3' -0 "X12" Li 3 #5 F -4 4'- 0 "X4' -0 "X14" ao 4 #5 F -5 5' -0" X 5' -0" X 12" 5# 5 W a co Q F -4X6 6' -0" X 4' -0" X 16" 7 # 5 LW 14 #5 SW 04 W Z o_ C I w WF -84 8' -6" X 7' -6" X 24" #7 0 6" TOP & BOTT. #4 0 24" TRANSV. V) ul C) WF -16 x 16" X 12" ■ 3 #5 CONT. Ld WF -24 a 24" X 12" 3 #5 CONT. #4 0 16" TRANSV. WF -40 n V) 40" X 12" 4 #5 CONT. 1 #4 0 16" TRANSV. N ■ 0 WOOD TRUSSES 0 24' O:C. TRUSS ANCHOR SEE CONNECTOR SCHEDULE A' COX. PLYWOOD SHEATHING W 180 COMMON NAILS 06' OZ. F. EDGES 4 PERIMETER OVERHANG 2' -0' TB. 8' CONC. BLOCK ROOF TYP. SECTION SCALE: I'- 1' -0' STRUCTURAL NOTES: COORDINATION: - COORDINATE ALL DIMENSIONS, ELEVATIONS 4 OPENINGS WITH ARCHITECTURAL DRAWINGS. REPORT ANY DISCREPANCIES TO OUR OFFICE. CONCRETE: - COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON FILL: 2500 PSI ALL OTHER POURED -N -PLACE CONCRETE: 3000 PSI GROUT: 3000 PSI -TEST: A MIN. OF 5 CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 50 CU. YD. OR PORTION THEREOF SPECIMENS SMALL BE TESTED ACCORDING TO A.S.TM. C -3% ONE AT 3, ONE AT 1, AND 3 AT 28 DAYS. - COVER: CONCRETE DEPOSITED AGAINST THE GROUND: 3' FOF41ED CONCRETE IN CONTACT WITH THE GROUND:_2' BEAMS AND COLUMNS: 1 -1/1' INTERIOR SLABS: 3/4' EXTERIOR SLABS' 1 -1/2' POST- TENSIONED SLABS: 1' SLAB ON FILL: (PLACED ACCORDING TO ACI 302) - JOINTS: ISOLATION JOINTS MUST BE USED AT JUNCTIONS WITH WALLS AND COLUMNS, USE 1/2' THICK PREMOLDED JOINTS FULL DEPTH OF SLAB. CONTROL JOINTS PLACED AT CENTERLINE OF COLUMN LINES PROVIDE INTERMEDIATE JOINTS IF COLUMN SPACING IS GREATER THEN 30' IN SIDEWALKS PROVIDE TOOLED JOINTS SPACED AT INTERVALS EQUAL TO THE WIDTH OF THE SLAB. 4' 4 5' SLABS: I' DEEP TOOLED JOINTS MUST BE SAWED BEFORE 24 HOURS AFTER CONCRETING. CONSTRUCTION JOINTS MUST BE PLACED N THE SLAB WHERE BUILDING EXPANSION JOINTS ARE SHOWN AND WHERE CONTROL JOINTS ARE SHOWN. WHEN CONCRETING AND OPERATING ARE CONCLUDED FOR THE DAY, CONSTRUCTION JOINTS SHALL BE FORMED WITH BURKE KEYED KOLD METAL JOINT FORM OR APPROVED EQUAL. -VAPOR BARRIERS: WATERPROOF MEMBRANES (OVERLAPPED 6' AT JOINTS) WITH A PERMEANCE OF LESS THAN 03% PERMS IN ACCORDANCE WITH A.S.TM. E -98 SHALL BE PROVIDED UNDER INTERIOR SLAB. WHERE NO VAPOR BARRIER IS USED THE SUBGRADE MUST BE DAMPENED WITH WATER IN ADVANCE OF CONCRETING NO FREE WATER STANDING ON THE SUBGRADE NOR ANY MUDDY OR SOFT SPOT IS PERMITTED. -ANY STRUCTURAL MEMBER PENETRATING SLAB ON FILL IS TO BE IR' PRE- MOLDED JOINT FILLER COMPLYING WITH AS.TM. D -1152, TYPE I. - FINISHING: NO PREMATURE FINISHING SHALL BE ALLOWED. IMMEDIATE FOLLOWING FLOATING TROWELING WITH STEEL 'TROWELS SHOULD BE COMMENCED IF REQUIRED BROOMING SHALL BE AFTER THE STEEL TROWELING OPERATION. -SLAB FINISHES: (UNLESS OTHERWISE NOTED BY THE ARCHITECT) BUILDING: STEEL TROWELED OUTSIDE SLAB: -BROOMED REINFORCING STEEL: - REINFORCING BARS CONFORMING TO AS.TM. A -815 GRADE 60, INCLUDING COLUMN AND BEAM TIES. - WELDED FIRE FABRIC CONFORMING TO AS.TM. A -185 AND SUPPORTED ON SLAB BOLSTERS SPACED AT 3' -0' O /C. - FABRICATION AND DETAILING ACCORDING TO A.C.I.-315. -ALL ACCESSORIES TO HAVE UPTURNED LEGS AND BE PLASTIC DIPPED AFTER FABRICATION. WELDING: -ALL WELDING SHOULD BE PEWDRMED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH BY AIDS. BY CERTIFIED WELDERS. - CONTRACTORS TO USE E -10 SERIES LOW HYDROGEN ELECTRODES. DESIGN CRITERIA: SUPERIMPOSED LOADS LIVE LOAD: DEAD LOAD: - ROOF: 30 PSF 25 PSF -FLOOR 40 PSF 50 PSF WIND LOAD: V -146 MPH EXP. C, IF. -1, KD-I NER ARCHITECT. AND CONTRACTOR NOTE: -CHECK FOR SHOP DRAWINGS AND INSPECTIONS OF REINFORCEMENT IN THE FIELD ARE REQUIRED IF THIS OFFICE IS TO BE HELD RESPONSIBLE FOR THE STRUCTURAL. ADEQUACY OF THE CONSTRUCTED BUILDING. -ALL SHORING, RE- SHORING AND TEMPORARY BRACING REQUIRED IN THIS PROJECT IS TO BE DESIGNED BY FLORIDA RESTRICTED ENGINEER WHO SPECIALIZES N FORM WORIQTEMPORARY BRACING DESIGN. AND WHO HAS BEEN HIRED BY THE GENERAL CONTRACTOR THE GENERAL CONTRACTOR IS THE ULTIMATE RESPONSIBLE PARTY FOR SHORING, RE- SHORING, AND TEMPORARY BRACINCs REQUIRED ON THIS PROJECT AND MUST SATISFY HIMSELF WITH THE ADEQUACY OF THE INSTALLATION OF THESE ITEMS AT ALL TIMES. IN THE SPECIFIC CASE OF POURED SLABS IT IS HIGHLY RECOMMENDED THAT FROM THE SHORING DESIGNER OR HIS AGENT PRIOR TO THE PLACEMENT OF CONCRETE THE GENERAL CONTRACTOR SECURE A CERTIFICATION OF THE INSTALLED SHORING. FETY OSHA AND LABOR LAWS. -THE STRUCTURAL ENGINEER OF RECORD DOES NOT POSSES, NOR PRESUMES TO POSSES ANY KNOWLEDGE OR EXPERTISE IN MATTERS TO JOB SITE EMPLOYEE SAFETY, OSHA OR LABOR LAE REQUIREMENTS FOR A CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS ARE THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THOSE CONSULTANTS HE HIRES TO ADDRESS THESE MATTERS. THE STRUCTURAL ENGINEER OF RECORD SPECIALIZES IN STRUCTURAL DESIGN ONLY, AND THE BOARD OF PROFESSIONAL REGULATION FORBIDS HIM FROM ASSUMING RESPONSIBILITY OUTSIDE HIS AREA OF EXPERTISE 'PLICABLE CODES: - ALTHOUGH T14E ENGINEER OF RECORD HAS STRIVED TO MEET ALL APPLICABLE CODES AND LOCAL ORDINANCE REQUIREMENTS, THE CONTRACTOR IS STILL RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND ORDINANCES OF THE EVENT OF CONFLICT OR OVERSIGHT N THE DRAWINGS THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER OF ANY CONFLICT OF DISCREPANCY ENCOUNTERED SO THAT APPROPRIATE REMEDIES MAY BE UNDERTAKEN. -THE APPLICABLE CODES ARE: FLORIDA BUILDING CODE A.C.I. 318 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. A.IS.C. MANUAL OF STEEL CONSTRUCTION, 9th EDITION. ASCI 98 SHOP DRAWING SUBMITTALS: - SUBMIT ONE SEPIA AND ONE PRINT OF ALL SHOP DRAWINGS LISTED BELOW. IF SIGNED AND SEALED SHOP DRAWINGS ARE REQUIRED, THEN SUBMIT TWO ADDITIONAL SIGNED AND SEALED PRINTS FOR APPROVAL. -SHOP DRAWINGS: REINFORCED STEEL. STRUCTURAL STEEL. CONCRETE MIX DESIGN. TIMBER B- ALL ROOF MEMBERS TO BE SECURED TO TIE BEAM OR OTHER STRUCTURAL ELEMENT WITH HURRICANE ANCHORS. C- TRUSS MANUFACTURER TO SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY HIS REGISTERED ENGINEER BEFORE SUBMITTING FOR APPROVAL. MASONRY NOTES: (TYPICAL FOR ALL LEVELS) _ I. ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASOORY BLOCK MANUFACTURED IN CONFORMANCE WITH ASTM C -90 AND PROJECT SPECS. THESE MASONRY UNITS SHALL PROVIDE A MINIMUM PRISM STRENGTH F'm= 1500 PSI IN 28 DAYS AS - - - - DELIVERED TO THE JOB SITE. MANUFACTURER SHALL SUBMIT PRISM TEST RESULTS FOR ALL MASONRY USED ON TINE PROJECT PRIOR TO CONSTRUCTION. THREE PRISMS SHALL BE MADE FOR EACH TEST OF 5000 SQ. FT. OF WALL. PRISMS SHALL BE TWO BLOCK NIGH, USING TYPE M MORTAR ON FACE SHELL ONLY AND MADE TESTED N CONFORMANCE WITH A.S.T.M. C 140 -90, TOGETHER WITH A.S.T.M. E 441. METHOD B AS MODIFIED N ACI 530.1 92. MASONRY UNIT STRENGTH - 1900 PSI 2. ALL GROUTING SHALL COMPLY WITH ASTM C -416 WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS. MIX SHALL HAVE 3/8' MAX. SIZE AGGREGATE WITH A MINIMUM SLUMP OF 8'. GROUT SHALL BE SAMPLED AND TESTED AS PER ASTM C -39, WITH A MR OF 3 TESTS PER 30 YD. OR LESS BEING PLACED EACH DAY. 3. TYPE M MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT AND PROPORTIONED AS OUTLINED UNDER ASTM C -210. HOLLOW UNITS SHALL BE LAID WITH RILL MORTAR COVERAGE ON HORIZONTAL AND VERTICAL FACE SHELLS EXCEPT THAT WEBS SHALL ALSO BE BEDDED IN ALL COURSES OF COLUMNS, IN THE STARTNG COURSE ON FOOTINGS AND SOLID FOUNDATION WALLS, AND AT GROUTED CELLS. HORIZONTAL AND VERTICAL FACE JOINTS SHALL BE 3/8' THICKt U.ON. VERTICAL JOINTS SHALL BE SHOVED TIGHT. MORTAR PROTRUSIONS EXTENDING INTO CELLS OR CAVITIES (THAT ARE TO BE REINFORCED AND GROUTED) SHALL BE REMOVED. ALLOW MIN. 24 HOURS FOR MORTAR TO CURE PRIOR TO GROUTING 4. STANDARD HIGH -LIFT GROUTING PROCEDURES SHALL BE FOLLOWED. LAY UP BLOCK AS REQUIRED. DROP VERTICAL STEEL INTO CELLS CONTAINING DOWELS AND SECURE IN PLACE. PROVIDE CUTOUT ON FACE FOR CLEAN OUT, STEEL TYING AND INSPECTING, AND GROUT FLOW VERIFICATION. GROUTING SHALL BE DONE IN MAX. OF 4' -0' LIFTS, CONTINUING AROUND BUILDING AND RETURNING TO THE STARTING POINT WITH APPROXIMATELY ONE HOUR DELAY PRIOR TO COMMENCING WITH NEXT 4' -0' GROUT LIFT. GROUTING SHALL BE CONTINUOUS UNTIL COMPLETION. THE LEVEL OF GROUT SHALL BE STOPPED 1 -1/1' FROM TOP OF THE LAST MASONRY UNIT. WHERE BREAK AWAY OR BREAK OUT IS CALLED FOR OR REQUIRED, A SAW CUT SHALL BE USED. FOLLOW ABOVE PROCEDURE TO ROOF LEVEL. 5. ALL WALLS SHALL BE REINFORCED AND GROUTED VERTICAL AND HORIZONTAL CONTINUOUS AS SHOWN ON DRAWINGS. ALL WALL OPENINGS SHALL HAVE A MIN. OF 2 0 5 VERTICAL EA SIDE AND 2 0 5 TOP AND BOTTOM(U.OA ON PLANS AND SCHEDULES). ALL SPLICING IN REINFORCING BARS SHALL BE A MIN. LAP OF 6 X BAR NUMBER MASONRY CONTRACTOR SHALL PROVIDE 'LADUR' TYPE 'DUR -O -WALL' HORIZONTAL REINFORCING AT ALTERNATE COURSE I6' C/C UDA DUR -O -WALL SHALL BE CONTINUOUS WITH A MIN. SPLICE OF 6'. PROVIDE PREFAB TEES AND CORNER SECTION AS REQUIRED. ALL LINTEL REINFORCING BARS SHALL EXTEND NOT LESS THAN 24' BEYOND EA SIDE OF ALL OPENINGS. 6. MASONRY CONTRACTOR SHALL LAY BLOCK UNITS SO AS TO ASSURE TIGHT HEAD JOINTS AND SNUG BED JOINTS FOR SHRINKAGE CONTROL AND WATER TIGHTNESS. MORTAR JOINTS SHALL BE TOOLED WHEN THUMB PRINT HARD TO INCREASE WATER TIGHTNESS. ALL ADJUSTMENTS TO BLOCKS NOTED ON PLANS SHALL BE SAW CUT. WHERE BREAK AWAY OR BREAK OUT IS CALLED FOR, A SAW CUT SHALL BE USED. 1. CONTRACTOR SHALL RETAIN THE SERVICES OF AN INDEPENDENT TESTING LAB TO PROVIDE TESTING IN CONFORMANCE TO PLANS AND SPECIFICATIONS. ALL TESTING SHALL BE PAID BY THE OWNER S. ALL MASONRY DESIGN AND CONSTRUCTION SHALL COMPLY WITH ACI 530 -92 AND ACI 530.1 -92 - PROVIDE 0 9 TRUSS TYPE (LADDER TYPE FOR REINFORCED MASONRY) HORIZONTAL MASONRY REINF. 0 16' O/C N ALL MASONRY WALLS - IN ALL VERTICAL REINFORCEMENT PROVIDE FOUNDATION DOWELS AND STANDARD HOOKS AT TOP TIE BEAM. - SPLICE VERTICAL MASONRY WALL REINFORCEMENT 48 BAR DIAMETERS AS FOLLOWS: FOR 0 5 BARS: 30' FOR 0 6 BARS: 36' FOR 01 BARS: 42' STRUCTURAL STEEL: -ALL STRUCTURAL STEEL PLATES SHALL CONFORM TO A.S.T.M. A -36 NOT DIPPED GALVANIZED. - PLATES SHALL BE TOUCHED AFTER WELDING HAS TAKEN PLACE. -ALL STRUCTURAL STEEL WELDING SHALL BE PERFORM WITH A.W.S. D.I.I. -ALL ANCHOR BOLTS SHALL CONFORM TO AS.T.I A -301. -ALL BOLTS SHALL CONFORM TO A.S.T.M. A -325. - ALL STRUCTURAL TUBING SHALL BE CONCRETE FILLED AND CONFORM TO A S. T. M. A -500, PROVIDE 1/4' DIA. PRESSURE RELIEF HOLES IN EACH COLUMN, AT TOP, BOTTOM AND MID -POINT. (FY- 46 K S. D - PROVIDE ONE SHOP COAT OF RUST INHIBITING PANT MIN. 3 ML. DRY FILM THICKNESS). - FABRICATIONS AND ERECTIONS SHALL BE DONE IN ACCORDANCE WITH THE LATEST A SPECIFICATIONS. FOUNDATION RECOMENDATION : ALL SOIL SUPPORTING FOUNDATIONS SHALL BE PREPARED AS RECOMMENDED BY 'ALL STATE ENGENIERNG 4 TESTING CONSULTANTS INC.' OF MIAMI, FLORIDA, TO PROVIDE AN ALLOWABLE BEARING CAPACITY OF 3000 "P. CERTIFICATION OF BEARING CAPACITY SHALL BE SUBMITTED BY A GEOTECHNICAL ENGINEER REGISTERED N THE STATE OF FLORIDA PRIOR TO POURING FOUNDATIONS _C f C.A. Nx 26217 16581 SW 64tH TER. MAW FLORIDA 33193 TeL 786.336.1082 Fax 954.441.8444 E-maA: NW S= a= W F I=- 3 pJ oa Sow 000 xwo �02 F- OUj w� Eom wNo �0m <IL O REVMIONS JBY 05 %,/2005 'goo, 04 N wC) m � N Z Li N �-LT� w o E, w ao 0� 80 W wQ W a co Q 04 W Z o_ C I w 6e. � V) ul C) x w ■ V J Ld zwz a � o L1zi n V) f— N N ■ 0 z� oz a �(D r� a. rn 0 °o a 'goo, 04 wC) m ca Z (- v ) w W E, w ao 80 c)::, rx A W a co W 04 W Z C O ul C) x C) V J p E- zwz a O n V) DRAWN E.Y.R. CHECKED EAC. DATE DEC. 21 '04 SCALE SHOWN JOB NO. 04 -1221 SHEET S -6 OF 9 SHEETS