05-226(2)-026CAP FOR FUTURE
CONNECTION SOLAR
OR HEAT RECOVERY
GATE VAL
r
HEAT TRAP
N.W. TO FIXTURES
HOT WATER 3/4'
UNION
DRAIN VALVE
EMER3. DRAIN
HEAT TRAP
GATE VALVE
GOLD WATER, 3/4'
UNION
PRESSURE 4 TEMPERATURE
RELIEF VALVE (ASME APPRVD.)
AIR GAP
3/4' Cu RELIEF DISCHARGE
LINE, TO OUTSIDE GREEN
AREA, TERMINATE 6'
ABOVE FIN. GRADE
WALL BRACKET ------ L"_I LEI
1' DP.
WATER HEATER PIPING DIAGRAM
NO SCALE
PLUMBING GENERAL NOTES AND SPECIFICATIONS:
I. A. SCOPE OF WORK:
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE
DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE
SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO:
I. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS
2. SANITARY DRAIN AND VENT SYSTEMS
3. PLUMBING FIXTURES AND TRIM
PLUMBING FIXTURE SCHEDULE
MARK
TRAP
FIXTURE
HOT
COLD
ELECT.
SIZE
UNITS
WATER
WATER
WC
3'
3
-
1/2 •
LAv
II/2'
1
'/2'
'/2'
SH
2'
2
li2 '
I/2 .
SK
11/2 '
2
1/2 '
1/2 '
WM
2'
2
1/2,
1/2 .
DW
1' SW
N/A
1/2'
-
HB
-
_
-
1/2' W/vALVE d
n.2
32,700/4(o,500
- - --
23x44x32
VAC. BREAKER
TUB
2'
11/2'
2
I/2 •
1/2
30
Ups.
Aj3.
- - --
- - --
14x22x35
BD
2
11/2
2
1 2 / ■
1 2
/
U.C.
A.G.
10.9
16,300122,200
- - --
AIR CONDITIONING SCHEDULE
UNIT
MANUFACTURER
NOM.
NOM.
ESP IN.
ELECT.
TOTAL
COOLING CAP. S/T
O/A
DIMENSIONS
WEIGHT
ELECT. SERVICE
RPM
x
AND MODEL NO.
TONS
CFM
LUG.
HEAT KW
LA /HP
BTUH 6 957 t 6'i? W
CR-1
WxLxH (IN.)
LBS.
VOLTS/PH /Hz
SEER
AHU
RHEEM- RBHC2IJIISFG
- - --
1600
.40
10
4.6/1/3
- - --
- - --
21x22x35
155
208- 230/1/60
121
CU
»1
RHEEM- RAMC048JAZ
4
-'-'
-'--
- ---
n.2
32,700/4(o,500
- - --
23x44x32
245
208- 23011160
AHU
"2
RHEEM- R5HC14J065FN
- - --
800
30
5
`. 1/1/6
- - --
- - --
14x22x35
98
208- 230/1/60
-
120
02U
RHEEM- RAMCO24JAZ
2
- - --
- - --
10.9
16,300122,200
- - --
19x36x24
145
208 - 23011160
rO
U
RHEEM- R5HK25J115FC
- - --
2000
AO
10
4.6/3/4
- - --
- - --
25x22x35
176
208- 23011160
12.6
GU
RHEEM- RAMC060JAZ
5
- - --
- - --
- - --
288 !
38,500/55,500
32x44x33
315
208- 23011160
w
A
Cn
W
®
�e
'
NOTE: OR EQUAL
1) FIXTURES TO COMPLY W/FBC 2001 Plumbing Sections
-f 09.1,603.1 4 6043
2) ANTI -SCALD VALVE:
ALL SHOWERS 8 BATH /SHOWER COMBINATIONS SHALL
BE PROTECTED WITH A CONTROL VALVE OF THE
PRESSURE BALANCE, THERMOST6TIC MIXING OR COM-
BINATION TYPE SET. HANDLE POSITION STOPS PER
MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION
TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120° F.
HVAC DESIGN REQUIRES:
YES
NO
DUCT SMOKE DETECTOR
1V2'x 1/6'
x
FIRE DAMPER (S)
DIMENSIONS
x
SMOKE DAMPER(S)
1�1 'x 1 18'
x
FIRE RATED ENCLOSURE
RPM
x
FIRE RATED ROOF/FLOOR
CEILING ASSEMBLY
VOLTS/PH/Hz
x
FIRE STOPPING
REMARKS
x
SMOKE CONTROIL
CARNES- VCDD008C
x
48
10 m 1/8'
120/1/60
4. AIR CONDITIONING CONDENSATE DRAINS
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER
6. PIPING INSULATION
T SUPPORTS AND HANGERS
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
EDITION OF THE 'FLORIDA BUILDING CODE' AND LOCAL ORDINANCES
AND IN COMPLIANCE WITH THE 'FLORIDA ENERGY EFFICIENCY CODE FOR
BUILDING CONSTRUCTION', AND 'HR5' REGULATIONS. IN THE EVENT OF
CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT
REQUIREMENTS WILL GOVERN.
2, CONTRACTOR TO VERIFY AT SITE THE LOCATION, ELEVATION AND SIZE OF ALL
EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING.
3, UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS
COMPOUND BEFORE COVERING
4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS
OR SHOCK ABSORBERS (ARRESTORS) . WASHING MACHINE SHALL HAVE WATER
HAMMER ARRESTOR FOR BOTH CW 4 HW.
5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2' LINE FROM THE NEAREST
PLUMBING FIXTURE.
6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS,
SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS
AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED.
FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC.
1. UNDERGROUND WASTE LINES 3' AND ABOVE TO BE PVC $CH. 40 AND SLOPE m I/8'/ FT.
WASTE LINES 2' AND UNDER, AND ABOVE GROUND PIPES SLOPE m 1 /4'/FT.
8. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT
EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS
AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE.
9. VENT LINES TO EXTEND V MIN. ABOVE ROOF AND FLASH WITH LEAD.
10. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE 'K' ABOVE GROUND TO BE
COPPER TYPE 'L'. OR APPROVED CPVC . NO JOINTS ALLOWED UNDERGROUND.
11. PIPING
A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER
INTERVALS ACCORDING WITH CODE.
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR
MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES.
C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE
ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE
DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES. PROVIDE
CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS.
12. INSPECTIONS AND TESTS
A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE
AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL
SYSTEMS SHALL BE TESTED BY CODE AND/OR LOCAL REGULATIONS.
B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF
SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE
HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE BY AN
OWNER REPRESENTATIVE.
13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED
LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE).
RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER
BEFORE PLACING IN SERVICE,
14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST
AFTER COMPLETION OF THE INSTALLATION.
AIR FLOW
SEAL JOINT WITH
EPDXY 4 DUCT TAPE
LOW VELOCITY -
SUPPLY AIR DUCT
(SEE PLAN VIEW)
INSUL R -6
METAL ROUND FITTING
QUADRANT OPERATOR
TO BE OUTSIDE INSULATION
PROVIDE INSULATION GUARD
WHERE NECESSARY
FLEX. DUCT. '
POLYETHELENE
) STEEL
:)RCIN63(R -6)
FAN SCHEDULE
=C>oll
MANUFACTURER
PTHRU 2 SOFT
1V2'x 1/6'
W.O.
ELECT. SERVICE
DIMENSIONS
WEIGHT
4THRU I08QFT
1�1 'x 1 18'
FAN •
AND MODEL NO.
RPM
WATTS
CFM o S.P.
VOLTS/PH/Hz
WxLxW OW
LBS.
REMARKS
SONES
EF-0I
CARNES- VCDD008C
1500
48
10 m 1/8'
120/1/60
8x81 /25xl /4
40
W /GRILLE, 4'm DUCT SAI
21
i
7
DAMPER 4 ROOF CAP
EF02
CARNES- VCDD020C
1500
131
200 is I /8'
120/1/60
121/4xI2l/4xII34
20
W /GRILLE, 6'm DUCT S/M
Ib
DAMPER 4 ROOF CAP
K EF
VIKING CUSTOM HOOD
1500
1/20
tOO�liB'
115/1/60
CUSTOM
rO
W /ST STEEL HOOD FILTERS
LIGHT 4 64, S/P1
- --
HOOD
26 GA DUCT THRU ROOF W /GAP
PIPE INSUL.
-11 f /CONDENSING
CONCRETE
M4 ---- t PAD SHALL BE
NOT LESS THAN
4' THICK
REFRIGERANT LINES ANCHOR W/POWER DRIVEN
STUDS OR 3 /S'X1.5'LG.
TO AIR HANDLER TAP -CONS, OR LAG BOLTS
THRU CEILING SPACE SHIELDS -' BASE PLATE TO WITHSTAND
WINDS GONDENS ING UNIT AN ANCHOR BOLT OF 500
AIR FLOW
INSTAL I AT I ON DETAIL POUNDS MIN. FULL OUT CAPACITY.
DAMPER LE VOLUME NO S C A L E
SEAL JOINT WITH
EPDXY 4 DUCT TAPE
PERORATED DIFFUSER
TYPICAL DIFFUSEiR CONNECTION DETAIL
NO SCALE
SUPPLY DUG
R /A DUCT
REFRIGERANT LINES WHEN APPLY
TO OUTSIDE CONDENSING
UNIT THRU ATTIC SPACE
3/4' CONDENSATE
DRAIN w/ 3' TRAP
UNION AND C.O TO
GREEN AREA
GALV. STEEL
A.H.U. SUPPORT
(SELF-STANDING) -�
NO COMBUSTIBLE
MATERIALS WITHIN
A.H.U. ROOM
R/A THRU
LOUVER DOOR -,�-►
WHEN APPLY
pm 1 vm4h,: �
ROOF CAP
MECHANICAL ATTACH
PLENUMS AND RETURN
W/FLEXIBLE CONN.
CEILING
PARTITION
PERFORATED CAP FOR
--VENT, 12' HIGH
-SECONDARY
DRAIN
PROVIDE 4' CLEARANCE
ALL AROUND AHU
/ FLOAT SWITCH J
/DRAIN PAN
FLOOR
2'A /C C.D.
UNDERSLAB
AIR HANDLER KNIT
INSTALLATION DETAIL
NO SCALE
WF"7
CLG.
ROOF CAP. ---�
MAH/AUS 1 VUC- I
EXHAUST PAN DUCT- DETAIL
6' Z
-----
ATTIC SPACE
6'0 26 GA.
GALV. METAL DUCTS.
-INTERIOR WALL.
x-6'41 GALV. METAL DUCT
THRU DROP CEILLING
SPACE UNTIL INTERIOR
WALL.
2nd FL.
KITCHEN
COOK HOOD EXHAUST RISER
N.T.S.
WOOD
SCREU
HANGER -
STRAP 1112',
FOR DUCT
WIDE, FAS'
BOT OF D
AIR CONDITIONING SYSTEM - GENERAL NOTES:
M
Y .cr `!!►s:.
I. DUCTWORK SHALL BE 1 1/2' THICK, 3 POUNDS PER CUBIC FOOT DENSITT
FIBERSLASS WITH VAPOR BARRIER UNLESS OTHERWISE SPECIFIED
DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORD CE
WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO 'ASHRAE'
AND '_r-MAC-NA' STANDARDS.
DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE
DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY WITH
'NFPA' STANDARD NO. SOA AND /OR 908. DUCTWORK AND COMPONENTS
SHALL BE CLASS I MATERIALS IN ACCORDANCE WITH U,L. 181 i
TESTS.
I
2. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES
ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUET
SYSTEM A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TR,4 DEp
THE FABRICATION AND INSTALLATION OF THE SYSTEM.
�F
3. DIFFUSERS SHALL BE SELECTED, LOCATED, AND BALANCED IN ORDER':
THAT THEY DELIVER THE REQUIRED CFI TO THE ENTIRE ROOM EVENLY '
AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: * '
INSIDE OUTSIDE RELATIVE HUMIDI �4
COOLING - 76' DB SI DB - 79 WB 509, TO 609. 40.,AW
HEATING - 10' DEB 41' - DB
4. ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, tX
AS REQUIRED TO OPERATE QUIETLY SO THAT N005JECTIONABLE SOUND
WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY,
MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT.
. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED A5 ;
REQUIRED FOR EASY ACCESSIBILITY. «
5 '
6. A/C SYSTEM SHALL BE CONTROLLED BY A PROGRAMMABLE THERMOSTAT,
MOUNT PROGRAMMABLE THERMOSTAT V -0' ABOVE FINISHED FLOOR U.ON.
'I. ALL GRILLS AND DIFFUSERS TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF-
FUSERS TO HAVE OPOSED BLADE DAMPERS. PROVIDE GASKETS i
ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREGUIDE OR APPROVED EQUAL
WHITH ENAMEL FINISH ' •.
8. UNDERCUT DOORS I' APR, FOR R/A FOR ROOMS WITH LESS THAN 110 CR'I �.
FOR ROOMS WITH OVER 110 CFM PROVIDE R.A.G. AND TRANSFER DUCT.
S. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - i
ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS :SHALL BE i
WROUGHT COPPER ALL JOINTS SHALL BE MADE WITH HIGH
TEMPERATURE BRAZING ALLOY OF NOT LESS THAN 5% SILVER
PIPING INSTALLATION NOT LESS THAN 3/4' THICK 'ARMAFLEX'.
LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO
EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT `
LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING
ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY EQUIPMENT ±t,
MANUFACTURER ALL PIPING SHALL BE EVACUATED PER GOOD +
PIPING PRACTICE BEFORE START -UP.
I'i2' MIN. :y `Panr
STROP 26 G 3 ...
DUCT SIZE
=C>oll
D 6'4, 5/M 26 G. EF%2
PTHRU 2 SOFT
1V2'x 1/6'
W.O.
2 THRU 45QFT.
1V 'x 1/8'
8' -0'
MAH/AUS 1 VUC- I
EXHAUST PAN DUCT- DETAIL
6' Z
-----
ATTIC SPACE
6'0 26 GA.
GALV. METAL DUCTS.
-INTERIOR WALL.
x-6'41 GALV. METAL DUCT
THRU DROP CEILLING
SPACE UNTIL INTERIOR
WALL.
2nd FL.
KITCHEN
COOK HOOD EXHAUST RISER
N.T.S.
WOOD
SCREU
HANGER -
STRAP 1112',
FOR DUCT
WIDE, FAS'
BOT OF D
AIR CONDITIONING SYSTEM - GENERAL NOTES:
M
Y .cr `!!►s:.
I. DUCTWORK SHALL BE 1 1/2' THICK, 3 POUNDS PER CUBIC FOOT DENSITT
FIBERSLASS WITH VAPOR BARRIER UNLESS OTHERWISE SPECIFIED
DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORD CE
WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO 'ASHRAE'
AND '_r-MAC-NA' STANDARDS.
DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE
DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY WITH
'NFPA' STANDARD NO. SOA AND /OR 908. DUCTWORK AND COMPONENTS
SHALL BE CLASS I MATERIALS IN ACCORDANCE WITH U,L. 181 i
TESTS.
I
2. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES
ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUET
SYSTEM A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TR,4 DEp
THE FABRICATION AND INSTALLATION OF THE SYSTEM.
�F
3. DIFFUSERS SHALL BE SELECTED, LOCATED, AND BALANCED IN ORDER':
THAT THEY DELIVER THE REQUIRED CFI TO THE ENTIRE ROOM EVENLY '
AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: * '
INSIDE OUTSIDE RELATIVE HUMIDI �4
COOLING - 76' DB SI DB - 79 WB 509, TO 609. 40.,AW
HEATING - 10' DEB 41' - DB
4. ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, tX
AS REQUIRED TO OPERATE QUIETLY SO THAT N005JECTIONABLE SOUND
WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY,
MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT.
. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED A5 ;
REQUIRED FOR EASY ACCESSIBILITY. «
5 '
6. A/C SYSTEM SHALL BE CONTROLLED BY A PROGRAMMABLE THERMOSTAT,
MOUNT PROGRAMMABLE THERMOSTAT V -0' ABOVE FINISHED FLOOR U.ON.
'I. ALL GRILLS AND DIFFUSERS TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF-
FUSERS TO HAVE OPOSED BLADE DAMPERS. PROVIDE GASKETS i
ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREGUIDE OR APPROVED EQUAL
WHITH ENAMEL FINISH ' •.
8. UNDERCUT DOORS I' APR, FOR R/A FOR ROOMS WITH LESS THAN 110 CR'I �.
FOR ROOMS WITH OVER 110 CFM PROVIDE R.A.G. AND TRANSFER DUCT.
S. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - i
ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS :SHALL BE i
WROUGHT COPPER ALL JOINTS SHALL BE MADE WITH HIGH
TEMPERATURE BRAZING ALLOY OF NOT LESS THAN 5% SILVER
PIPING INSTALLATION NOT LESS THAN 3/4' THICK 'ARMAFLEX'.
LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO
EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT `
LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING
ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY EQUIPMENT ±t,
MANUFACTURER ALL PIPING SHALL BE EVACUATED PER GOOD +
PIPING PRACTICE BEFORE START -UP.
I'i2' MIN. :y `Panr
STROP 26 G 3 ...
DUCT SIZE
HANGER SIZE
MAX. SPACING
PTHRU 2 SOFT
1V2'x 1/6'
W.O.
2 THRU 45QFT.
1V 'x 1/8'
8' -0'
4THRU I08QFT
1�1 'x 1 18'
OVER 10SQFT
It''x 1 /S'
I W -0'
DUCT HANGING DETAIL
--1t-2' MIN.
I�
RLEX D
FLEX
v
.y
t.
GEORGE E. PEON
ARC #11%CT,, A.I.A.
, 4AR# 0007999
•� ; J
A.,gCHITECTURE
PLANNIN4
INTERIORS
4143 SW 74 t SUITE D
MIAMI, FL. 33155
PH. (305) 269 -933,
FAX..{ ) 269 -94$7
JOREV1SIOS +r.,.;�
BY
i,;
OF:
SHEETS
r
i
7
t�
4t +
3.,
t
O
r
G4
W
CJ
w
A
Cn
W
®
�e
'
z
pr�
A
M LY•
O
c
O
a
a
L
_
.1
'1
c•
1
Now
�1
'DRAWN: E.H.L.
CHUCKED: G.E.P.
DATE:
SCALE: AS SHOWN.
JOB NUMBER:
SHEET:
mp
OF:
SHEETS