Loading...
07-685R-009AT EACH MEMBEI 10d NAILS I 2 MEMBER GIRDE DESIGN FOR HORIZONTA LOAD OF 4 Kips FROI ROOF SHEATHIN, BOTTOM CHORD BRACING SEE PLAN PROVIDE 202 BOTI CONNECTED TO EXI' WITH 5/8" x 8" A.B. a) G GENERAL STRUCTURAL NOTES 1.0 GENERAL: A. STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH CIVIL. ARCHITECTURAL. MECHANICAL. AND ELECTRICAL DRAWINGS TO LOCATE DEPRESSED SLABS. SLOPES. DRAINS. OUTLETS. RECESSES. OPENINGS. BOLT SETTINGS. SLEEVES, DIMENSIONS. ECT. 1. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNERS REPRESENTATIVE IN WRITING FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. B. ALL MATERIALS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH THE OF THE FLORIDA 2004 BUILDING CODE AND THE LATEST ACI. ASTM. AND RISC SPECIFICATIONS AND RECOMMENDED PRACTICE. C GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING, EXISTING FACILITIES. STRUCTURE AND UTILITY LINES FROM ALL DAMAGE. LOCATION VERIFICATION OF ALL UTILITIES SYSTEMS SHALL BE THE CONTRACTORS RESPONSIBILITY. D. CONTRACTORS SHALL VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. E. NO DIMENSION SHALL. BE SCALED FROM THE DRAWINGS. 1. CONTRACTORS SHALL CHECK AND VERIFY ALL PLANS, DIMENSIONS AND SITE CONDITIONS PRIOR TO CONSTRUCTION. B. CONTRACTOR SHALL FINALIZE HIS COST ESTIMATE FROM PLANS THAT ARE FULLY APPROVED BY BUILDING DEPARTMENT. FINAL ESTIMATE SHALL HAVE ALLOWANCE FOR ALL REQUEST MADE BY BUILDING DEPARTMENT OFFICIALS. 1.02 BUILDING DESIGNED FOR THE FOLLOWING LIVE LOADS ROOF ................ 30 PSF. FLOOR LOADS ......... 40 PSF. WIND ................ AS PER ASCE 702. FOR 146 MPH. 2.01 FOUNDATIONS: A. FOUNDATIONS HAVE BEEN PROPORTIONED WITH A BEARING CAPACITY OF 2000 PSF. N EW VALLEY -rml lt`flr -r- A SECTION )SCALE: 3/4" = 1' -0" M% Jwl C SECTION SCALE: 3/4" = V-011 --0" 5.0 PLYWOOD ROOF SHEATHING: a. SHEATHING SHALL BE C —D EXTERIOR SHEATHING. PANNEL INDEX 32/16 MIN.. RATED FOR EXPOSURE 1; MIN THICKNESS 19/32 b. INSTALL SHEATHING CONTINUOUS OVER TWO OR MORE SPANS WITH FACE GRAIN PERPENDICULAR TO SUPPORT. C. NAIL SHEATHING TO SUPPORT WITH 10d NAILS SPACED AT 6" O.0 AT PANNEL EDGES 3.01 CONCRETE: A. CAST IN PLACE CONCRETE SHALL BE A MIX DESIGN IN ACCORDANCE WITH ACI — 318 TO ACHIEVE THE SPECIFIED COMPRESSIVE STRENGTH OF 3000 PSI. EXIST. ROOF CUT OVERHANG AS READ. NEW 1/2- PLYWOOD EACH SIDE OF ROOF ASSEMBLY EXTENDED 1' -6" FROM WALL NAIL TO MEMBERS WITH 16d NAILS O 4" O.C. PER SIDE AT TOP & BOT. CHORD 1. NEW R85 ON ARC PROFILE 2. 2x8 RAFTER CONNECT TO R85 WITH 3/8" x 6" A.B. # 16" 3. 2x8 ROOF RAFTER 4. RAKE BEAM FOLLOWING ROOF PROFILE. MIN 8x8 WITH 2 # 5 5. NEW VALLEY CRICKET AS READ. FOR DRAINAGE. MAKE WITH VALLEY TRUSS AN TOP OF EXIST. 6. EXIST ROOF RAFTER CUT MASONRY AROUND RAFTER WRAP WITH 30 lb FELT FILL VOID WITH GROUT 7. # 5 O 48 TO RAKE BEAM DOWEL IN 3/4" x 6" EPDXY FILLED HOLE 8. EXIST WALL 9. CUT EXIST. OVERHANG 2x1 CHC TRIM BOT. CHORD TO MATCH ADJACENT TRUSS GEOMETRY END CONNECTION FOR END GIRDER 6.0 TIMBER: A ALL TIMBER DESIGN AND FABRICATION SHALL CONFORM WITH THE APPICABLE PROVISIONS OF THE NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. PUBLISHED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION, AND THE DESIGN SPECIFICATIONS FOR METAL PLATE CONNECTED WOOD TRUSSES. PUBLISHED BY THE TRUSS PLATE INSTITUTE. B. SUBMIT SHOP DRAWINGS FOR ALL WOOD STRUCTURAL MEMBERS AND CONNECTIONS TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. C. ALL TIMBER SIZES. CONNECTORS. FRAMING PLANS NOT SHOWN ON STRUCTURAL DRAWINGS SWILL BE PROVIDED B'Y THE FABRICATOR AND DETAILED ON HIS SHOP DRAWINGS. D. ALL MATERIALS AND AND CONNECTIONS ARE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER. E. ALLOWABLE UNIT STRESSES LUMBER USED FOR JOIST RAFTERS, TRUSSES, COLUMNS do BEAMS SHALL BE OF NO LESS STRENGTH OF 111 2 GRADE SOUTHERN PINE. LUMBER USED FOR EXTERIOR OR INTERIOR BEARING WALLS SHALL BE OF NO LESS STRENGTH OF STUD GRADE OF SOUTHERN PINE. F. BRACING. a ALL TRUSSES AND WOOD FRAMING MUST BE SECURELY BRACED BOTH DURING ERECTION AND AFTER PERMANENT INSTALLATION IN ACCORDANCE WITH "BRACING WOOD TRUSSES: COMMENTARY AND RECOMMENDATIONS (BWT -76) " AS PUBLISHED BY TRUSS PLATE INSTITUTE. b ERECTION BRACING SHALL HOLD TRUSSES STRAIGHT. PLUMB AND IN A SAFE CONDITION UNTIL DECKING AND PERMANENT TRUSS BRACING HAS BEEN FASTENED FORMING A STRUCTURALLY SOUND ROOF FRAMING SYSTEM. ALL ERECTION AND PERMANENT BRACING SHALL BE INSTALLED AND ALL TRUSSES PERMANENTLY FASTENED BEFORE APPLICATION OF ANY LOADS TO THE WOOD FRAMING SYSTEM. c ALL BRACING REQUIREMENTS ALONG WITH PERMANENT STRUCTURAL CROSS BRACING TO ENSURE OVERALL RIGIDITY OF THE ROOF SYSTEM SHALL BE IN ACCORDANCE WITH THE WOOD ROOF TRUSS DESIGNERS PLANS. d. SAFE ERECTION OF TRUSSES IS THE RESPONSIBILITY OF THE BUILDING CONTRACTOR. m 7yTTi J -'ll 0 D SECTION SCALE: 3/4" = 1' -0" 2#6x4'DRILL EXIST. IN 1" DIA. x 8" EPDXY BEAM FILLED HOLE NEW BEAM OR COLUMN CONNECTION: NEW BEAM TO EXISTING BEAM 2 #6x4'DRILL EXIST. IN 1" DIA. x 8" EPDXY BEAM FILLED HOLE • �— NEW COLUMN CONNECTION: NEW COLUMN TO EXISTING BEAM m CHOR� OL T N u- 0 M u_ Q T EXIST.ROOF � g ccb M JOIST W, V Q r Vow w � ; Q O Yo Q Rj�� �= � z m�U o° �� Q �LL� m N 00� Q z d' � co ooc B SECTION SCALE: 3/4" = V-021 --0" EPDXY FILLED HOLE BEAM SOFFIT EPDXY SHALL BE OR FOOTING HILT] "HIT HY 150" OR APPROVED EQUAL REBAR CITY OF SOUTH MIAMI BUILDING DEPT. STRUCTURAL SECTION APPROVED BY: �Q OATE- - , tip,_ _ COMBINED ENGINERI St l CARLOS ENSENAT, FE', 88'x',, CERTIFICATE OF y �kIZA'h0 1' -,Wo. 9.108 1214 SW 12 CT.; -..1;� ��o• 3 =_ �% ; MIAMI, FL. 33135; 305) 856 -634 t+ . 1174' • . `•1 .s i zi 0i `I W rv! a, SHEET 159 i i i i l 1 i I � OL u- 0 u_ Q z � N � Q Q o z c Lu LLJ i zi 0i `I W rv! a, SHEET 159 i i i i l 1 i I �