07-685-022GENERAL NOTES IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY WITH THE ARCHITECT IN WRITING ANY OMISSIONS OR DISCREPANCIES OR DIMEN51ONAL ERRORS CONTAINED IN THESE DRAWINGS. ALL WORK SHALL BE CONSTRUCTED UNDER APPLICABLE LOCAL, COUNTY, STATE OR FEDERAL ORDINANCES, REGULATIONS, STANDARDS OR CODES. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION AND AVAILABILITY OF ALL UTILITIES AND COORDINATING HI5 WORK WITH THE UTILITY COMPANIES. BID SHALL INCLUDE ALL FEES REQUIERED FOR PERMITS AND UTILITY CONNECTIONS. CONTRACTOR 15 TO INCLUDE ALL DRIVE5 AND WALKS AS SHOWN ON PLANS. CONTRACTOR SHALL CARRY ALL NECESSARY INSURANCE AS MAY BE REQUIERED BY THE OWNER AND LOCAL GOVERNING AUTHORITIES. BEFORE THE START OF CONSTRUCTION, THE CONTRACTOR 15 TO INFORM THE OWNER IN WRITING THE INSURANCE THEY WILL BE RESPONSIBLE FOR. CONTRACTOR 15 TO PROVIDE TOILET FACILITIES FOR WORKERS AND TO KEEP SITE IN AN ORDERLY AND CLEAN MANNER. CONTRACTOR SHALL COORDINATE WORK WITH ALL TRADES AND NO ADDITIONAL PAYMENTS WILL BE MADE BY THE OWNWER DUE TO THE CONTRACTORS FAILURE TO CORRECT FIELD WORK AFTER THE WORK HAS BEEN DONE. THE ARCHITECT OR THE ENGINEER WILL NOT BE RESPONSIBLE FOR, NOR HAVING CONTROL OR CHARGE OF THE CONSTRUCTION MEANS, METHODS, PROCEDURES, OR SAFETY PRECAUTIONS AT THE JOB SITE. DO NOT SCALE DRAWINGS, USE DIMENTION5 AS INDICATED. THE CONTRACTOR 15 RESPONSIBLE TO VERIFY ALL DIMENTION5 AND DETAILS THAT THEY COINCIDE WITH EACH OTHER. NOTIFY ARCHITECT IN WRITING FOR ANY CLARIFICATIONS. ALL WORK SHALL BE PROTECTED FROM OTHER TRADES AND NO WORK OR ITEMS WILL BE ACCEPTED IF FINISH 15 MARRED. ALL WORK 15 TO BE IN GOOD WORKMANSHIP AND MEET CONSTRUCTION STANDARDS AS APPLICABLE. NO ITEMS WILL BE SUBSTITUTED UNLESS VERIFIED BY THE OWNER AND APPROVED. CONTRACTOR 15 TO FURNISH TO OWNERS ALL WARRANTIES AND OPERATING INTRUCTION5 AT FINAL COMPLETION. IF THERE 15 ANY QUESTIONS REGARDING THE BEARING CAPACITY OF THE EXISTING 501L CONDITION, THE CONTRACTOR 15 TO NOTIFY THE ARCHITECT IN WRITING BEFORE PROCEEDING WITH THE WORK. CONTRACTOR 15 TO SUBMIT SHOP DRAWINGS IF PLANS 50 STATE AND RECEIVE APPROVAL BEFORE FABRICATION OR INSTALLATION OF ITEM. CONTRACTOR 15 TO COORDINATE WITH THE OWNER THE SELECTION OF LIGHT, PLUMBING FIXTURES, TRIM, ALL CABINETRY, APPLIANCES, TILE, AND ANY FINISHES TO COMPLETE CONSTRUCTION. FOR CONCRETE SPECIFICATIONS SEE STRUCTURAL NOTES. STUCCO ON EXTERIOR WILL BE GRAY STUCCO AND FINISHED AS ON ELEVATIONS. A MINIMUM OF A TWO COAT APPLICATION ON MAN50NRY AND CONCRETE AND THREE COATS ON METAL LATHE. PROVIDE A SAMPLE AREA FOR REVIEW AND APPROVAL BY OWNER AND ARCHITECT. CAULKING TO BE THROUGHOUT PROJECT IS POLY5EAM5EAL, APPLIED IN AN EVEN WORKMANSHIP MANNER. DRYWALL- INTERIOR WALLS AND CEILING TO BE 5/8" DRYWALL � JOINT COMPOUND INTERIOR BEARING WALL5 TO HAVE 5/8" "X" TYPE FIRE RATED BOARD, ONE LAYER EACH SIDE. BATHROOM WALLS TO RECEIVE TILE USE WONDERBOAKD. GARAGE CEILING AND PARTY WALL TO HAVE 5/8" TYPE "X" PAINTING- INTERIOR TO HAVE WALLS WITH ONE COAT PRIMER AND TWO COATS PAINT AS SELECTED BY OWNWRR. WOODWORK TO HAVE ONE COAT UNDERBELLY AND TWO COATS SEMI GLO55 ENAMEL. EXTERIOR STUCCO WALL5 TO HAVE ONE COAT PRIMER, TWO COATS FINAL COLOR. WOOD FASCIA AND SOFFIT TO HAVE ONE COAT PRIMER AND TWO COATS FINISH. ROOFING- SEE TYPICAL SECTION- SUBMIT SAMPLE AND COLOR OF ALL FINISHED ROOFING TO OWNER FOR APPROVAL PRIOR TO ORDERING PRODUCTS. WINDOWS AND DOORS- SEE SCHEDULES. REQUIREMENTS FOR MEANS OF ESCAPE PRIMARY MEANS OF ESCAPE: IN ANY DWELLING OR LIVING UNIT OF 2 ROOMS OR MORE, EVERY BEDROOM AND LIVING AREA SHALL HAVE AT LEAST 2 MEANS OF ESCAPE OR ALTERNATE PROTECTION, AT LEAST I OF WHICH SHALL BE A DOORS OR STAIRWAY PROVIDINGA MEANS OF UNOBSTRUCTED TRAVEL TO THE OUTSIDE OF THE DWELLING AT STREET OR GROUND LEVEL. NO BEDROOM OR LIVING AREA SHALL BE ACCESSIBLE BY ONLY A LADDER OR FOLDING STAIRS OR THROUGH A TRAP DOOR. U51NG R.00M5 A5 PASSAGE , REMOVE ALL SECURITY LOCKS, ONLY PASSAGE LOCKS. SECONDARY MEANS OF ESCAPE: THE SECONDARY MEANS OF ESCAPE OR ALTERNATE SHALL BE ONE OF THE FOLLOWING: A DOOR, STAIRWAY, PASSAGE OR HALL PROVIDING A WAY, INDEPENDENT OF AND REMOTE FROM THE PRIMARY MEANS OF ESCAPE, OF UNOBSTRUCTED TRAVEL TO THE OUTSIDE OF THE DWELLING AT STREET OR GROUND LEVEL. A PASSAGE THROUGH ADJACENT NON - LOCKABLE SPACES INDEPENDENT OF AND REMOTE FROM THE PRIMARY MEANS OF ESCAPE TO ANY APPROVED MEANS OF ESCAPE. AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE IN51DE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" IN WIDTH, 24" IN HEIGHT AND 5.7 SQUARE FEET IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" OFF THE FIN. FLOOR, SUCH MEANS OF ESCAPE SHALL BE ACCEPTABLE IF: THE WINDOW 15 WITHIN 20' -0" OF GRADE, OR THE WINDOW 15 DIRECTLY ACCE51BLE TO FIRE DEPARTMENT RESCUE APPARATUS AS APPROVED BY THE BUILDING AND /OR FIRE OFFICIAL, OR THE WINDOW OR DOOR OPENS ONTO AN EXTERIOR BALCONY. THE MODE OF OPERATION DOES NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT TO MAKE AVAILABLE THE REQUIRED CLEAR OPENING, AND NO PART OF THE OPERATION MECHANISM SHALL BE PLACED HIGHER THAN 54" ABOVE THE FINISH FLOOR. THE BEDROOM OR LIVING AREA SHALL BE SEPARATED FROM ALL OTHER PARTS OF THE LIVING UNIT BY CONSTRUCTION HAVING A FIRE RESISTANCE OF AT LEAST 20 MINUTES AND SHALL BE EQUIPPED WITH A DOOR THAT WILL RE515T THE PASSAGE OF FIRE FOR AT LEAST 20 MINUTES, AND 15 DESIGNED AND INSTALLED TO MINIMIZE SMOKE LEAKAGE. A MEANS OF PROVIDING SMOKE VENTING AND FRESH AIR TO THE OCCUPANTS, SUCH AS AN OPERABLE WINDOW, SHALL BE PROVIDED. GENERAL STRUCTURAL NOTES I . FOUNDATION SHALL BE SPRED AS FOOTINGS ON A 501L MIN. BEARING CAPACITY OF 2000P5f.. 2. FILL WITH GOOD MATERIAL, IN LIFTS NOT TO EXCEED G ", MECHANICALLY COMPACT CLEAN FILL TO DESIRED LEVEL BELOW FLOOR SLAB. 3. ALL CONCRETE SHALL ATTAIN A MINIMUM COMPRE551VE STRENGTH OF 3000 PSI AT THE END OF 28 DAYS 4. ALL REINFORCEMENT SHALL BE DEFORMED BARS GO K51 MINIMUM GRADE YIELD NEW BILLET STEEL IN ACCORDANCE WITH A5TM GRADE GO. ALL BAR LAPS SHALL BE A MINIMUM OF 48 BAR DIAMETERS. PLACING OF REINFORCEMENT SHALL COMFOKM TO THE 2004 FLORIDA BILDING CODE. 5. MINIMUM CONCRETE COVER OVER REINFORCEMENT SHALL BE BOTTOM TOP SIDES FOOTINGS 3" 2" 3" BEAMS AND COLUMNS 1 1/2" 1 1/211 1 112" G. ALL CONCRETE SHALL BE PLACED WITHIN 90 MINUTES FROM BATCH TIME. 7. STRUCTURAL NOTES: A. PRIMARY WOOD FRAMING MEMBERS SHALL BE NO. 2 SOUTHERN PINE OR BETTER, SURFACED DRY, USED AT 19% MAXIMUM M.C. WITH THE FOLLOWING STRESS RATING, UNLESS NOTED OTHERWISE: Fb SINGLE MEMBER 1,200 psi Fb REPETITIVE MEMBERS 1,400 psi Fc PERPENDICULAR TO GRAIN 5G5 E 1 , 600000 B. ALL WOOD IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED. C. METAL STRAPS, CLIPS AND HARDWARE SHALL BE GALVANIZED. BLOCK WALL5 ARE 8 "X I G" CMU AND SHALL HAVE A MINIMUM FACE SHELL THICKNESS OF 1 -1/4 ", A MINIMUM WEB THICKNESS OF I ", CONFORMING TO THE STANDARD SPECIFICATIONS FOR HOLLOW LOAD - BEARING CMU'S, MINIMUM COMPRESSIVE STRENGTH, PSI, ON GROSS AREA, AVERAGE OF THREE UNITS 700 -1 ,000, INDIVIDUAL UNITS 000 -800. A5TM C90. MORTAR USED TO BOND UNIT MASONRY SHALL BE OF TYPE M OR 5. ALL MORTARS AND MATERIALS THEREIN SHALL COMFORM TO A5TM C270. MORTAR SHALL BE A PLASTIC MIX HAVING A MAXIMUM SLUMP OF 9" +/- I ". PLACE ONE #5 BAR MIN. AT EACH 51DE OF ALL MASONRY OPENING. SEE PLANS FOR STEEL REINFORCEMENT REQUIEREMENTS. PROVIDE HORIZONTAL REINFORCEMENT NO. 9 GAUGE LADDER TYPE EVERY OTHER COURSE THROUGHOUT ALL MASONRY WALLS. HOOK TOP OF COLUMN BAR5 AND TIE RODS INTO TIE BEAM COURCE CELL GROUT AS FOLLOWS: 3000 psi @ 28 DAYS 1/4" MAXIMUM AGGREGATE 9" +/- I " SLUMP BURGLAR INTRUSION WINDOWS AND HARDWARE LOCKS ON INTRUSION DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300LB5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN CHAPTER 3G OF THE SOUTH FLORIDA BUILDING CODE, DADE COUNTY, FLORIDA (REVISED 94) ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 0000 P05515LE KEY CHANGES OR LOCKING COMBINATIONS. IF KEY -IN -THE KNOB 15 USED, THERE SHALL BE AN AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT OR INSERTS, (APPLIES AL50 TO DOOR TO GARAGE) THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE THE SAME LOCKS AS REQUIERED FOR SINGLE EXTERIOR SWING DOORS. THE INACTIVE LEAF OF THESE PAIR OF DOORS SHALL HAVE MULTIPLE POINT LOCKS WITH 5/8" MINIMUM THROW BOLT5 WITH INSERTS. HINGES OF EXTERIOR OUT SWINGING DOORS SHALL HAVE THE NON - EXPOSED SCREWS. EXPOSED PINS SHALL NOT BE REMOVABLE. SINGLE SWINGING EXTERIOR DOORS, SHALL COMPLY WITH THE AMERICAN NATIONAL 5TANDAK5 INSTITUTE 297. 1. VISION PANELS IN EXTERIOR DOORS, OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATING DEVICE OF LOCKS AND SWINGING GLA55 DOORS SHALL COMPLY WITH AMERICAN NATIONAL STANDAR5 INSTITUTE 297.1 OR FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A SCOPE OR VISION PANEL. NOT LF-55 THAN 1 3/4" THICK. "X I I "X 1/4" STEEL PLATES LDED BASE PLATES. 3/4" GALV. THRU -BOLT P OF TIE BEAM 5/8 "X9" GALV. J -BOLT5 4 "X I I "X 1/4" STEEL BASE PLATE WELDED VERTICAL PLATES TRANSER TRUSS CON. DTL SCALE 3/411= I' -0" 4 112" X9 "X 114" STEEL PLATE WELDED TO VERTICAL STEEL PLATES. ADJUSTED PLATE LENGTH TO FIT NUMBER OF TRU55 PLY5 (3 3/8" 2 -PLY : 3 -PLY) 2 -4 112"X 12 314 "X 114" 5TEE PLATES WELDED TOP PLATE CUT TOP EDGE TO MATCH SLOPE OF ROOF. •" BOLT GALV. THRU BOLT -3 "X 21 3/8" X 1/4" STEEL LATH5 WELDED TOP PLATE OF OF TIE BEAM 5/8 "XG" HILTI KWIK BOLT (00045372) W/ A MIN. - 4 1/2" EMBEDDMENT GIRDER TRU55 CON. DTL. SCALE 3/411= 1 ' -0" COLUMN BAR, BENT 90 DEG., 1'-0" INTO BEAM STEEL RENF. BARS TIE DOWN IN CONC. FILLED CELLS (TYPICAL) SEE SCHEDULE BAR TI E DOWN DTL. NTS ui io0l/ -AKl= n000/-MiGrA COLUMN BAR, BENT 90 DEG. I' -0" INTO BEAM STEEL i . • ' • ' is ' � ~ % '.! •. ' . d° • • REI NFRCED BARS IN CONC. COL. SEE SCHEDULE BAR TIE DOWN DTL. NTS 4 1/2" X9 "X 1 /4" STEEL PLATE WELDED TO VERTICAL STEEL PLATES. ADJUSTED PLATE LENGTH TO FIT NUMBER OF TRU55 PLY5 (3 3/8" 2 -PLY * 5" 3 -PLY) 2 -4 112"X 12 314 "X 114" STEEL PLATES WELDED TOP PLATE. CUT TOP EDGE TO MATCH SLOPE OF ROOF. 6 ' d 3/4" BOLT GALV. THRU BOLT 2 -3 "X 21 3/8" X 1/4" STEEL PLATES WELDED TOP PLATE TOP OF TIE BEAM 2- 5 /8 "XG" HILTI KWIK BOLT 1 1 (00045372) W/ A MIN. OF 4 1/2" EMBEDDMENT 3N 1 /4" TWO PLY TRUSS DTL. NTS SEE DOOR DEPRESSIO 5CHEDULE OVERHEAD DOOR 2"XG" W/ 3/4" ANCHOR BOLT @ 12" O.C. EMBEDED G" C NC. EDGE OR CONC. SLAB BEGINING OF SLOPE TO w� zt m DRIVEWAY N • j•' DRIVE GARAGE DOOR DTL. NT5 Q 1 WALL CABIN ETS �s _I BASE CABINETS 2 "X4 "X2' C NOTE: BLOCK WALLS USE I XG P.T. INSTEAD OF 2X4 FOR PARTITION WALL5 LIGHT SHOWER = RAILING I z — J I � U 0 z Q WOOD BLOCKING DTL SCALE 3/411= 1 ' -0" '`t - I I =QW1041 Ra) - - - ROBERT KOGER AIA ArcPi Wct: AR- 0005174 r S � Date Ic� z O U J ^W CZ a SHEET A -5 GOf 13 r ` % N Q o Ln O O Q mLn �O u- `n m 0 LL.I I— Q W - w (,D C) OLL-' 0- 0 NQLn — CS N <zDLn �L -- o 7,-, , O Q W a CO N zw OR/ Lu ��in w �< �Oz co�O z O U J ^W CZ a SHEET A -5 GOf 13 r ` % N Q o O O Q u- 0 (,D C) ^�/ _ (D <zDLn Q W O O zw w o 0 Lu �, / LL LL. IL/ W Q N U z O U J ^W CZ a SHEET A -5 GOf 13 r ` %