05-548-001I®
0
c�
0
� I
z
w
I—
c I
w°
a- U
CL YI
U
crmI
N �
� U
0
oZ
I I
FD. 1/2" IRON PIPE 75.0'
L.B. #87
T —�
T
T
T
T�
Tj
T
T
T =
WOOD FENCE _
TT 24 "OAK TREE TO REMAIN
AND BE PROTECTED
T 9 "QUEEN PALM TO REMAIN
TI AND BE PROTECTED
T�
T 4" QUEEN PALM TO
T BE REMOVED
T
I NEW SCREENED PATIO
ADDITION
NEW DINING ROOM
ADDITION L 83
^ P
I P. -:.7-r -`- I
0
co
co
T_
N
I
N
8' -f
EXISTING
1 -STORY RES.
RES. NO. 6481
NEW PORCH
TRELLIS
NEW
GARAGE
I „ O
24 "OAK TREE TO REMAIN
`- AND BE PROTECTED
N 9" QUEEN PALM TO
BE REMOVED
L.B. FD. 3 8 IRON PIPE 17' GUMBO LIMBO TO
L.B #87 BE REMOVED
OF ROAD
S.W. 73RD STREET
�ITNI* PLAN
V low T— ®w
SOUTH MIAMI LAND DEVELOPMENT CODE
SECTION 20-3.5 (E)
DIMENSIONAL REQUIREMENTS
SINGLE - FAMILY DISTRICT
SIZE
REQUIRED
PROVIDED
ZONING
RS -3
-
MIN. LOT SIZE
NET AREA (SQUARE FOOTAGE)
10,000
10,200
FRONTAGE (FT.)
75
75
MIN. YARD SETBACK (FT.)
FRONT
25
25' -4"
REAR
25
47' -9"
SIDE (INTERIOR)
FOR STRUCTURE 12' OR LESS
IN HEIGHT, AS MEASURED
FROM THE FIRST FLOOR
FINISHED FLOOR ELEVATION
7.5
8'-5"
FOR STRUCTURE 12' OR LESS
IN HEIGHT, AS MEASURED
FROM THE FIRST FLOOR
FINISHED FLOOR ELEVATION
15
N/A
SIDE (STREET)
15
N/A
MAX. BUILDING HEIGHT
STORIES
2
1
FEET
25
111-0"
MAX. BUILDING
COVERAGE ( %)
FIRST FLOOR
30
22
SECOND FLOOR:
% OF THE FIRST FLOOR
60
N/A
MAX. IMPERVIOUS COVERAGE ( %)
40
26
8.45
N
D. 1/2" IRON PIPE
F.D. 1/2" IRON PIPE
WOOD FENCE
F.D. V2' IRON PIPE
L.B. #87
u\I
LEGAL DESCRIPTION:
LOT 7, NORTH MANOR. ACCORDING TO
THE PLAT THEREOF AS RECORDED IN
PLAT BOOK 67, PAGE 132, OF THE
PUBLIC RECORDS OF DADE COUNTY,
FLORIDA.
va• =T -o•
GENERAL
SOILS IS
MRK
SIZE
REINF
TYPE
REMARKS
1
16" X 12"
2 #5'S CONT.
SPREAD
- 2500
2
8 0X8"
1 #5
THICKENED EDGE
SHALL BE GRADE 60.
3
8 "X10"
1 #5
THICKENED EDGE
OF ALL FOOTERS TO BE MINIMUM 12'
4
4" SLAB
6X6 10/10 WWM
SLAB
ON COMP FILL WNAP BARRIER
5
24"X18"
3#5S CONT. T &B
MONOLITHIC
SEE DETAIL 9/A5-0
6
24724 'X12'
3#5S E.W.
ISOLATED
GENERAL
SOILS IS
NOTES
OF UNDISTURBED EARTH. CONTRACTOR
SHALL
SECURE THE SERVICES OF A TESTING LAB TO CERTIFY
THE SOIL
BEARING CAPACITY OF 2000 P.S.F.
CONCRETE
FOR FOUNDATION SHALL BE MIN. F'C
- 2500
PSI. ALL OTHER
CONCRETE
SHALL BE MIN. F'C - 3000 PSI. ALL
REBAR
SHALL BE GRADE 60.
SLAB ON
GRADE WIRE MESH SHALL BE SUPPORTED AT
A MAXIMUM OF 3' -0" O.C. PER FBC 1909.3 (2)
BOTTOMS
OF ALL FOOTERS TO BE MINIMUM 12'
BELOW
FINISHED GRADE PER FBC 1804.1.3
COMM N0:
05 -008
DATE:
FEB. 16, 2005
DRAWN BY:
CADD
XVIS 'MSMI ONS�AY 5, 2 FLAG IBmSI 005
a
a $
a v a_
°a`"n is
r. v
T
IN 1
111
o�LL
(9
W U�J
O
0
w Z
e O
�
LJO
Q O u.
z JUL
o
w 5
Q � N
v
J CJ
'MAY -0.5 • '•
i
SHEET N0:
G=J III 0