09-735-002DRAWINGS INDEX A -1 INDEX - GENERAL SPECS. A -2 SITE PLAN - CODE REQUIREMENTS A -3 FLOOR PLAN- FINISH SCHEDULE A -4 REFLECTED CEILING PLAN A -5 EXISTING BUILDING FRONT AND SIDE ELEVATIONS A -6 WINDOW - DOOR DETAIL /NOTES A -7 BATH AND MISCELLANEOUS DETAILS A -8 FIRE PENETRATION DETAILS A -9 RESTAURANT - KITCHEN LAYOUT - EQUIPMENT SCHEDULE A -10 EXISTING 2nd AND 3rd FLOOR PLANS E -1 POWER FLOOR PLAN E -2 LIGHTING FLOOR PLAN E -3 ELECTRICAL PANELS - RISER - NOTES M -1 MECHANICAL FLOOR PLAN M -2 MECHANICAL DETAILS P -1 SANITARY AND WASTE FLOOR PLAN P -2 GAS PLAN AND DETAILS P -3 WATER - WASTE - GAS RISERS P -4 GENERAL NOTES AND DETAILS S -1 FACADE ALTERATION PLAN SECURITY AND FORCED ENTRY PREVENTION NOTES 1. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB6, APPLIED iN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH. 2, ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROtM EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SiNGLE DEAD BOLT WITH HARDENED BOLT INSERT W/ A MiNIMUM THROW OF P OR WITH PANIC HARDWARE 3. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS. SHALL HAVE SAME LOCKS A6 REQUIRED FOR SINGLE EXTERIOR DOORS. THE INACTIVE LEAF OF THESE PAIRS OF OOO)R5 SHALL HAVE MULTIPLE POINT LOCKS WITH 5/6" MiNIMUM THROW BOLT WITH INSERTS. 4. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON - REMOVABLE PINS. 5. JAMBE OF ALL EXTERIOR OFFSET TYPE IN -SWING DOORS BE RABBETTED, OR OF 8iMILAkR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE iNTEGRIT "Y OF LOCKS AND LATCHES. 6. SUITE ENTRY DOORS THAT OPEN TO A PUBLIC CORRIDOR SHALL ALSO BE SECURED AS SPECIFIED IN ITEMS 2 t 3 ABOVE. 1. 6LA6$ AND EXTERIOR DOOR$ SHALL COMPLY WITH THE AMERICAN NATIONAL $TAND.AIRDS INSTITUTE'S STANDARD 291.1. 6. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATION DEVICE OF LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE'S STANDARD 291.1. 9. EXTERIOR OPERABLE WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS T'O COMPLY WITH THE ARCHITECTURAL ALUMINUM MFG$. A560C. 6TANDARD8 FOR FORCED ENTRY RESISTANCE, AAMA 13033 10. FRONT AND MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANEL. 11. REAR WiNDOWS NOT VISIBLE FROM THE 8TREET AND LOCATED WITHIN V OF THE WALK NG SURFACE SHALL BE GLAZED WITH BURGLAR RESISTANT MATERIAL OR PROTECTED WITH BURGLAR GUARD$ AS FOLLOWS: OPTION I: 1/2" DIAM. A36 STEEL BARS OR Pxl /4" FLAT SECTIONS OF A36 STEEL PLACED NOT MORE THAN 6" APART OPTION 2: GRiLL WORK OF 1/8" DIAM. A36 STEEL BARS WITH A MAX HORIZ t VERT. SPACING OF 2" ALL BURGLAR GUARDS SHALL BE SECURELY FASTENED AND SHALL NOT BE REMOVABLE FROM THE OUTSIDE WITH COMMON TOOLS. IF REAR WINDOWS ARE OPERABLE THEY SHALL BE PROVIDED WITH A LOCK FROM Tl­,E INSIDE CAPABLE OF WITHSTANDING A FORCE OF 150 LB5 APPLIED IN ANY OPERABLE DIRECTION. 12 ROOF SKYLIGHT$ SHALL BE GLAZED WITH BURGLAR RESISTANT MATERIAL OR PROTECTTED WITH BURGLAR GUARDS AS SPECIFIED IN ITEM 11 ABOVE. 13. ACCESS SCUTTLES ON ROOF SHALL BE CAPABLE OF WITHSTANDING FORCES EQUAL TO GLAZING MATERIALS COMPLYING WITH UL-V2, ASTM C1036 AND UL 12 THEY 814ALL BE SECURED FROM THE INSIDE WITH SLIDE BARS OR SLIDE BOLTS. 14. WHERE THERE 18 A LADDER FOR ACCESS TO ROOF WITHIN 8' OF WALKING SURFACE AND IT 15 NOT LOCKED TO PREVENT UNAUTHORIZED USE ROOF OPENINGS -SHALL BE PROTECTED WITH BURGLAR GUARDS AS SPECIFIED IN ITEM II ABOVE. THIS APPLIES TO ALL OPENING$ LARSER THAN 6" IN LEAST DIMENSION. 15. OPEN PARKING AREAS AND ACCE56 THERETO 6HALL BE PROVIDED WITH MAINTAINED ILLUMINATION OF 1/3 FOOTCANDLE OF LIGHT ON THE PARKING SURFACE FROM DUSK UNTIL 30 MINUTES AFTER TERMINATION OF %VNES$ EACH DAY OF OPERATION. THE RATIO OF MAXIMUM TO MINIMUM ILLUMINATION iN FOOTCANDLES SHALL NOT EXCEED 12:1. 16. THE AREA IMMEDIATELY OUTSIDE OF ALL EXTERIOR DOORS SHALL HAVE SECURITY ILLUMINATION AND SHALL BE ACTIVATED DURING THE DARK PERIOD OF EVERY DAY. DEMOLITION NOTES: 1. GENERAL CONTRACTOR SHALL EXERCISE CARE DURING DEMOLITION AND REMOVAL TO ASSURE THAT ITEMS SCHEDULED FOR DEMOLITION ARE PROPERLY REMOVED AND ITEMS TO REMAIN ARE PROTECTED FROM DAMAGE. PATCH AND REPAIR NEW AND DEMOLISHED AREAS TO MATCH EXISTING. 2. PEDESTRIAN PROTECTTiON MUST BE PROVIDED IN ACCORDANCE WITH 2004 FEBC 1303.2 PRIOR TO COMMENCING DEMOLITION. 3. A PARTY WALL BALCONY OR HORIZONTAL EXIT SHALL NOT BE DESTROYED UNLESS AND UNTIL A SUBSTITUTE MEANS OF EGRESS HAS BEEN PROVIDED AND APPROVED. FEBC 13033 4. SERVICE UTILITY CONNECTIONS MUST BE DISCONTINUED AND CAPPED IN ACCORDANCE WITH THE APPROVED RULES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. FEBC 1303.6 5. GENERAL CONTRACTOR SHALL PROVIDE ALL SHORING AND TEMPORARY 6UPPORT5 REQUIRED FOR THE DEMOLITION. 6. GENERAL CONTRACTOR SHALL PROVIDE ALL ACCESS BARRIERS, SAFEGUARDS, DUST BARRIERS, AND WARNING SiGNS AS REQUIRED. 1. GENERAL CONTRACTOR SHALL NOTIFY OWNER / ARCHITECT IN WRITING THREE (3) DAY$ PRIOR TO MAJOR ELECTRICAL OR MECHANICAL SHUTDOWN AND REQUIRED DOWNTIME SO APPROPRIATE ACTION CAN BE TAKEN. 6. ALL FINISHES AND 6UWACE5 WHICH ARE DAMAGED DURING DEMOLITION AND NEW CONSTRUCTION SHALL BE REPAIRED AND REPLACED TO THE -SATISFACTION OF THE PROJECT MANAGER AT NO ADDITIONAL COST TO THE OWNER 9. REFER TO ELECTRICAL AND MECHANICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK NOT NOTED ON THE ARCHITECTURAL SHEETS. 10. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSION$ AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES PRiOR TO PROCEEDING WITH THE WORK 11. ACTUAL EXISTING DIMENSIONS SHALL GOVERN. 12. VERIFY OPENINGS FOR FIFES AND DUCTS WITH MECHANICAL AND PLUMBING DRAWINGS. 13. CONTRACTOR A88UME6 FULL RESPONSIBILITY FOR PROTECTION t SAFEKEEPING OF GOODS BEING INSTALLED UNDER THIS CONTRACT, A$ WELL AS FOR COMPLIANCE WITH ALL APPLICABLE OSHA REGULATIONS. ABREVIATIONS A.F.F. Above Finished EXIST. Floor ACOUSTIC. Acoustica I ALUM. Aluminum ANOO. Anodized A.T. Aluminum threshold BD. Board B.O.B. Bottom of Beam CAB, Cabinet CLG. Ceilin CLOG. CIOSey CLR Clear CMU. Concrete Masonry Unit CNTR Counter COL. Column C.O. Clean Out CONC. Concrete CONN. Connection CONT. Continuous CT. Ceramic Tile D. Or DBL. Double ON. Down DR Door DTL. Detail DWG. Drawing Du Dishwasher DWR Drawer EA. Each EL. Elevation ELEC. Electrical ELEV. Elevation EQ. Equa I MAX. Maximum MECH. Mechanica I MIN. Minimum MISC. Miscellaneous MLO. Molding M.O. Masonry Openingq M.T. Marble Threshord MTO. Mounted MTL. Meta I MUL. Mullion NiC. Not in Contract NT8. Not to Scale O.C. On Center OD. Outside Diameter OPNG. opening OPT. Options I PBO. Particle Board PL. Plate PLAM. Plastic Laminate PLYWD. Plywood PAL Panel P.0.6. Point of sale PR Pair PREP. Preparation PTO. Painted QT. Quarry Tile RA. Return Air RAO, Radius RE. Reference EQUiP. Equipment EXIST. Existing EXT. Exterior FBO. Fiber Board FBO. Furnished by Others FD. Floor Drain FE. Fire Extinguisher FFtE. Furniture, Fixtures 4 Equipment FIN. Finish FLR. Floor FRP. Fiber lass Reinforced Plast�c FSE. Food Service Equip. F.V. Field verify GA. Gage GALV. Galvanized GC. General Contractor G.D. Garbage Disposal GL. Glass GYPBD. Gypsum Board INT. Inferior H.B. Hose Bib HC. Handicap Accessible HM. Hollow Metal HT. Heigght JET. Joist, LAM. Laminated LAV. Lavatory MANUR Manufactured M.T. Marble Threshold RECEPT- Receptacle REINF. Reinforced REQ'D. Required W. Room R.O. Rough Opening R.O.J. Received on Job G.C. Solid Core SHW. Shower 8/6 Stainless steel SCHEO. schedule aim. Similar $TD. Standard 6TL. Steel STRUCT. 6tructura I SUSP. Suspended TEMP. Tempered TYP. Typical VCT. Vinyl Composition Tile VERT. vertical VWC. Vinyl Wall Covering -per W. ahT W/O Without W.C. Water Closet WD. Wood W.H. Water Heater WIN. Window WSCT. Wainscot WT. Weight WWF. Welded Wire Fabric GENERAL NOTES ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL CODES, RULES, REGULATIONS AND RESTRICTIONS HAVING JURISDICTION ON THIS PROJECT. AS PER FLORIDA BUILDING CODE 21001. WORK SHALL INCLUDE ALL ITEMS (BUILDING AND SITE) INDICATED ON THESE DRAWINGS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED OF ANY DEVIATION FROM THE PLANS PRIOR TO CONSTRUCTION. DRAWINGS SHALL NOT BE 6CALEDt WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR GENERAL REVIEW AND DESIGN COMPLIANCE. CONTRACTOR SHALL MAINTAIN TEMPORARY ELECTRICAL, WATER AND SANITARY FACILITIES FOR THE DURATION OF CONSTRUCTION. CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROM THE JOB 81TE AND LEAVE THE BUILDING BROOM CLEAN. THE CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE SITE PRIOR TO CONSTRUCTION AND SHALL VERIFY ALL FiELD CONDITIONS PRIOR TO ACTUAL CONSTRUCTION. ANY DEVIATION FROM THE CONSTRUCTION DOCUMENTS DISCOVERED AT THiS TiME SHALL BE REPORTED BY THE CONTRACTOR IMMEDIATELY TO THE ARCHITECT. ALL WORKMANSHIP SHALL BE NEAT, CLEAN, TRUE AND CORRECT. SNALLGLASS fEMP��D SAFEtYUGLA55A5$ DOORS, OPERABLE GLASS) OMISSION$ FROM THE DRAWING6 OR SPECS. OR THE MISOESCRIPTiON OF DETAILS OF WORK WHiCH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS t SPECS., OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH PE A L C L 0 ENRRFOWEO S IF FLY ANND CORREY ? FORTH AD DESCRIBED iN THE DRAWINGS AND SPECIFICATIONS. DOORS 4 WINDOWS WHERE INDICATED IN PLANS, (EGRESS) MUST BE MANUFACTURED TO CONFORM TO THE BLDG. CODE W/ RESPECT TO MIN. EMERGENCY EGRESS REQUIREMENTS. NON- BEARING INTERIOR PARTITIONS ALL INTERIOR NON BEARING PARTITIONS SHALL BE 3 5/6" METAL STUDS 26 GA AT 24" O.C. MAX. SPACING W/ 1/2" MiN. GYPSUM DRYWALL EACH SIDE. GLASS BLOCK (IF APPLICABLE) MORTAR TO HAVE COMPRESSIVE STRENGTH: TYPE 6 - 1800 psi AT 20 DAYS EXPANSION STRIPS TO BE PLACED PER MFG- SPECS. ALL GLASS BLOCK SHALL BE INSTALLED PER F.B.G. 2001 SECTION 21212.12 ILDING IDENTIFICATION REQUIRED APPROVED NUMBER$ OR ADDRESSES BE PLACED ON ALL NEW AND EXISTING STRUCTURE IN SUCH POSITION A$ TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND EACH STRUCTURE, HAVING AN ADDRESS NUMBER, THE OWNER OR PERSON IN CHARGE OF THE BUILDING, SHALL CAUSE SUCH ADDRESS NUMBER TO BE DISPLAYED AT ALL TIMES IN NUMERALS ON OR ADJACENT TO THE BUILDING, OR PORTION, s0 THAT TIDE NUMERALS ARE READABLE FROM THE STREET OR THOROUGHFARE TO WHiCH THE NUMBER APPLIES. NUMERALS SHALL BE AT LEAST SIX INCHES IN HEIGHT FOR MULTIFAMILY RESIDENTIAL BUILDINGS-" ANCHORAGE METAL AND WiRE LATH: PNEUMATICALLY FASTENED W/ "PNEU -FAST" i6 GA. STAPLE SPEC. "101 -1 TYPE I OR BETTER (HOT DIPPED)-SATIN FIN. GALVANIZED COATING, HAVING A TENSILE STRENGTH OF 130M PSI. FASTENERS SHALL BE MIN. 1 1/2" LONG SPACED AT 6" O.C. MAX. t SIDE LAPS SHALL BE SECURED E 9" O.C. MAX. SECURITY NOTES ALL LOCKS ON EXTERIOR DOORS SHALL RESIST A FORCE OF 300 + APPLIED iN ANY MOVABLE DIRECTION. ALL EXTERIOR LOCKS SHALL BE SINGLE CYLINDER W/ 1" THROW FOR 13/4" SOLID CORE DOOR OPERABLE ROM EiXTERIOR WIIT DOORS INIMUM 6000 POSSIBLE OPERATED ANGEL KEY ON KNOB LOCKS SHALL HAVE AN AUXILIARY DEAD BOLT W/ HARDENED BOLT OR WITH INSERT. EXT. SWING DOORS SHALL BE SOLID CORE NOT LESS THAN 13/4" THICK FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED W/ A VISION SCOPE OR VISION PANEL. HINGES ON OUT $WINGING EXTERIOR DOORS SHALL HAVE NON - EXPOSED SCREWS AND NON- REMOVABLE PiNS. SINGLE SWING EXTERIOR DOORS CONNECTING LiViNG AREAS WITH GARAGE AREAS SHALL BE SOLID CORE 13/4" THICK AND SHALL BE SECURED WITH A LATCH AND SINGLE BOLT W/ ONE INCH MiN. THROW OR A COMBINATION OF DEAD BOLT AND DEAD LATCH SETS AND AN AUTOMATIC DOOR CLOSER ALL GLASS IN EXTERIOR DOOR$ SHALL COMPLY WITH ANSi 219.1 ALL WINDOWS (OPERABLE) SHALL WITHSTAND A FORCE OF 150' iN ANY OPERABLE DIRECTION. SLIDING GLASS DOORS t WINDOWS SHALL BE INSTALLED t CONSTRUCTED 80 THAT NO PANEL CAN BE LIFTED FROM THE TRACKS POSITION 4 SHALL COMPLY W/ THE AA.M.A 1303 -3 STANDARD$ FOR FORCED ENTRY RESISTANCE. SLIDING GLASS DOORS SHALL HAVE DEAD BOLT OR FIN SYSTEM NOT REMOVABLE FROM THE OUTSIDE AT THE JAMB AND SILL. INTERIOR DOORS TO HAVE A CYLINDRICAL TYPE LOCK SETS W/ PRIVACY LOCK BY INSIDE PUSH BUTTON WHICH AUTOMATICALLY OPENS BY TURN OR CL03ING ACCORDING TO FED. SPEC. 160 AND 1511. OVERHEAD DOORS SHALL BE PROVIDED WITH MULTIPLE POINT LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED BOLT$ WITH INSERT$ ENGAGING AT LEAST TWO OPPOSITE POINTS A MiN. OF 5/8 ". ELECTRICAL, MECHANICAL AND PLUMBING NOTES BEE MEP SHEETS. CITY OF SCU'tFI i'/IIAMI 3UILDING Or. p,r. STRUCTURAL NOTE$ ;rs�ucrUrt 7 t;T��3N SEE STRUCTURAL SHEETS. j n 14335 SW 120 street Miami, Florida, 33186 phone # (305- 408 -4025) fax # (305- 408 -4026) email -em fengineering@bellsouth.net APPROVALS /REVISIONS NOTES: • • ell O M w H ® to SEAL f ►!` ft R ENRIQUE L. FERNANDEZ P.E. FL. REG. # 21218 PROJECT: 4 r J C'N m ES OWNER CONTACT: OWNER TELEPHONE: TABU GROUP 305 - 669 -6281 SHEET TiTLE: SPECS - INDEX Job No. 5900 -09 Drawing No. Drawn By. J.B. A-1 Date: 8-3-09 OF Scale: AS NOTED 10