05-875-018ELECTRICAL NOTES
1. THE ENTIRE INSTALLATION SHALL BE IN
ACCORDANCE WITH THE LATEST EDITION OF
THE NATIONAL ELECTRICAL CODE (NEC), AND
THE LATEST EDITION OF THE FLORIDA
BUILDING CODE AND ANY OTHER APPLICABLE
FEDERAL, STATE AND LOCAL CODES.
2. A LICENSED ELECTRICAL CONTRACTOR
SHALL PERFORM ALL WORK IN A
WORKMANLIKE MANNER. SAID CONTRACTOR
SHALL MEET ALL REQUIREMENTS SET FORTH
BY ANY LOCAL ORDINANCE AND GOVERNING
AUTHORITIES.
3. THE CONTRACTOR SHALL PROVIDE ALL
REQUIRED INSURANCE FOR PROTECTION
AGAINST PUBLIC LIABILITY AND PROPERTY
DAMAGE FOR THE DURATION OF THE WORK.
4. THE CONTRACTOR SHALL GUARANTEE
ALL MATERIALS AND WORKMANSHIP FREE
FROM DEFECTS FOR A PERIOD OF NOT LESS
THAN (1) ONE YEAR FROM THE DATE OF
FINAL ACCEPTANCE.
5. IT SHALL NOT BE THE INTENT OF THESE
PLANS AND /OR SPECIFICATIONS TO SHOW
EVERY MINOR DETAIL OF CONSTRUCTION.
CONTRACTOR SHALL FURNISH AND INSTALL
ANY ADDITIONAL CONDUITS, BOXES AND
WIRING NECESSARY FOR A COMPLETE
ELECTRICAL SYSTEM AND PROVIDE ALL
REQUIREMENTS NECESSARY FOR EQUIPMENT
TO BE PLACED IN PROPER WORKING
CONDITION.
6. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR REPAIRING TO ORIGINAL
CONDITIONS, ANY AND ALL DAMAGES TO THE
BUILDING SURFACES, EQUIPMENT, ETC.
CAUSED DURING THE PERFORMANCE OF WORK.
7. CORRECTION OF ANY DEFECTS SHALL BE
COMPLETED WITHOUT ADDITIONAL CHARGE OR
DELAYS AND SHALL INCLUDE REPLACEMENT
OR REPAIR OF ANY OTHER PHASE OF THE
INSTALLATION, WHICH MAY HAVE BEEN
DAMAGED.
8. THE CONTRACTOR SHALL VISIT THE JOB
SITE AND VERIFY ALL EXISTING CONDITIONS,
AND SHALL THOROUGHLY REVIEW ALL
DRAWINGS, SPECIFICATIONS AND POSSIBLE
ADDENDA PRIOR TO BIDDING ON HIS WORK.
NO EXTRAS TO HIS CONTRACT WILL BE
ALLOWED FOR FAILURE TO COMPLY WITH THIS
REQUIREMENT.
9. THE CONTRACTOR SHALL NOT SCALE
THE ELECTRICAL DRAWINGS. REFER TO
ARCHITECTURAL PLANS AND ELEVATIONS FOR
EXACT LOCATIONS OF ALL EQUIPMENT UNLESS
NOTED OTHERWISE.
10. CONTRACTOR SHALL COORDINATE HIS
WORK WITH OTHER TRADES SO THAT
INTERFERENCE WITH EXISTING CONDITIONS,
CONDUITS, PIPING, EQUIPMENT,
ARCHITECTURAL AND STRUCTURAL MEMBERS
BE AVOIDED, BEFORE THE COMMENCEMENT OF
THE WORK.
11. CONTRACTOR SHALL TAKE PERMITS,
PROCURE CERTIFICATES AND PAY ALL FEES
CONNECTED THEREWITH.
12. IT SHALL BE THE RESPONSIBILITY OF
THE ELECTRICAL CONTRACTOR FOR THE
ADVANCED ORDERING OF LONG LEAD ITEMS,
AS TO NOT INTERFERE WITH THE PRODUCTION
OF OTHER TRADES RESULTING IN ANY DOWN
OR LAG TIME. THE CONTRACTOR SHALL NOT
ORDER ANY ITEMS UNTIL APPROVED SHOP
DRAWINGS ARE RETURNED TO HIM.13.
CONTRACTOR SHALL COORDINATE SERVICES
WITH THE RESPECTIVE UTILITY COMPANIES.
14. CONTRACTOR SHALL BE RESPONSIBLE
FOR VERIFICATION OF CEILING CONSTRUCTION
BEFORE ORDERING OR INSTALLING LIGHT
FIXTURES.
15. CONTRACTOR SHALL BE RESPONSIBLE
FOR PROPERLY BALANCING ALL BRANCH
CIRCUITS BETWEEN THE PHASES OF THE
SYSTEM REGARDLESS OF CIRCUITING
INDICATED.
16. ALL CONDUCTORS SHALL BE COPPER,
TYPE THHN /THWNNN EXCEPT WHERE
OTHERWISE REQUIRED BY U.L. OR CODES.
17. APPLY TWO COATS OF BITUMASTIC
(KOOPERS 60) TO ALL METALLIC CONDUITS IN
SLABS OR UNDERGROUND. EMT IS NOT
PERMITTED IN SLABS. ALUMINUM CONDUITS
ARE NOT PERMITTED ANYWHERE.
18. FOR UNDERGROUND ELECTRICAL
CONDUITS, PROVIDE PULL BOXES SUCH THAT
NO SINGLE CONDUIT RUN HAS BENDS IN
EXCESS OF 360 DEGREES, OR 180 DEGREES
FOR TELEPHONE. PULL BOXES SHALL BE
SUITABLE AND APPROVED FOR THE INTENDED
USE AND WITH IRON COVERS. WARNING
TAPES, WHICH READ, "WARNING- BURIED
ELECTRIC" SHALL BE PLACED IN TRENCHES
ABOVE ALL ELECTRIC CONDUITS. WHERE
CONDUITS PASS UNDER PAVED AREAS, THEY
SHALL BE GRC. WHERE UNDERGROUND
CONDUITS ARE NOT EXPOSED TO MECHANICAL
DAMAGE OR ARE NOT UNDER PAVED AREAS,
THEY SHALL BE SCHEDULE 40 PVC. ELBOWS
AND RISERS SHALL BE GRC.
19. ALL CONDUITS RUNS ARE SHOWN
DIAGRAMMATICALLY. THE EXACT ROUTING
SHALL BE DETERMINED IN THE FIELD, UNLESS
NOTED OTHERWISE.
LIGHTING
CEILING MOUNTED LIGHTING FIXTURE OUTLET
PROVIDE CEILING MTD. J -BOX
WALL MOUNTED LIGHTING FIXTURE OUTLET
PROVIDE WALL MTD. J -BOX
( l EXTERIOR WALL MOUNTED LIGHTING FIXTURE OUTLET
PROVIDE WEATHER WALL MTD. J BOX
NOTE: ALL LIGHTING FIXTURES SHALL BE
SELECTED AND PROVIDED BY OWNER
AND INSTALLED BY THE CONTRACTOR.
RECEPTACLES
20A, 125V, 2P, 3W, GNDING TYPE DUPLEX
RECEPTACLE MTD 18" AFF
20A, 125V, 2P, 3W, GNDING TYPE QUAD
RECEPTACLE MTD 18" AFF
CONDUITS
-' - CONCEALED CONDUIT (SWITCHED)
CONCEALED CONDUIT
BATH LIGHT
ELECTRICAL SYMBOLS LEGEND
MISCELLANEOUS SYMBOLS
GROUND
v PHONE LINE JACK MOUNTED 18" A.F.F.
UNLESS OTHERWISE NOTED.
EXTEND 1/2" CONDUIT W /BUSHED END
UP TO CEILING SPACE.
TV CABLE TV JACK MOUNTED 18" A.F.F.
UNLESS OTHERWISE NOTED.
EXTEND 1/2" CONDUIT W /BUSHED END
UP TO CEILING SPACE.
POWER DISTRIBUTION
0 120/24OV, 10, 3W PANELBOARD
2P— DISCONNECT SWITCH. 2P = # OF POLES,
30 30 = FRAME SIZE, * = FUSE
PER MANUFACTURERS RECOMMENDATIONS.
FIRE ALARM SYSTEM
PROVIDE NEW MASTEREEDROOM AND BEDROOM WITH
AFCI BRANCH CIRCUIT PROTECTION PER NEC 210.12
(THIS PERTAINS TO ALL OUTLETS, INCLUDING RECEPTACLES
LIGHTS AND SMOKE DETECTORS)
SWITCHED LEG
CONTROL WIRING TO OTHER
SMOKE DETECTOR INSIDE THE
SAME UNIT. SEE PLANS
SMOKE
DETECTOR
LIGHT SWITCH
NEUTRAL
SMOKE DETECTOR W/
BATTERY BACK -UP
LINE SIDE
OF SWITCH
120 V. LINE
SMOKE DETECTOR CONNECTION DETAIL
NOT TO SCALE
ABBREVIATIONS
E.F. EXHAUST FAN
M.C.B. MAIN CIRCUIT BREAKER
V VOLT
0
PHASE
W.P.
WEATHER PROOF
A.F.F.
ABOVE FINISHED FLOOR
G.F.I.
RECEPTACLE W /INTEGRAL
Li
GROUND FAULT CIRCUIT
U
INTERRUPTER
A. F. C. 1.
RECEPTACLE W /INTEGRAL
ARC FAULT CIRCUIT
U�
INTERRUPTER
SD SMOKE DETECTOR WITH VISUAL SIGNALING APPLIANCE
120 VOLT WITH INTEGRAL BATTERY BACKUP. CEILING MTD
"GENTEX" MODEL 7109CS SYNCHRONIZED W/ FORM C CONTACTS
HARD WIRE TO THE BATHROOM LIGHTING CIRCUIT.
TOGGLE SWITCHES
SINGLE POLE SWITCH, 20A, 125 VOLT RATED MTD 48" AFF
$3 20A, 120V THREE WAY SWITCH MTD. 48" AFF
_I •
n
FA_ f0
ON
i
r\
r
1 �
• Q o
C
DRAWN BY
OLIO C SILVA
cl-IECKm BY
Ya H
JOB No.
2004-0005
PAGE
IWEI
E.
n
Li
O
U
I
U�
N
o
Q
CEO
—
O
LL
U
U)
LL_
I
N
-
r )
V !
0
Q
Lc)
FA_ f0
ON
i
r\
r
1 �
• Q o
C
DRAWN BY
OLIO C SILVA
cl-IECKm BY
Ya H
JOB No.
2004-0005
PAGE
IWEI
E.