04-1517-052
129121V PANEL "A" 150 A. M.L.O. 1 PH.3w SURFACE M.T.D. BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A SPACE 2#4 -1 "C _ 5500 2P 1 2 2P tOTAL 216, 1 J8 -1 "C RANGE SPACE 0 5500 60 3 4 50 TELEPHONE OUTLET (5 ) INSTANT WATER HTR. 216, 1 J8 -1 "C. 6000 2P 5 6 2P 900 2 #10 -1/2 "C SPARE (12KW) $3 6000 60 7 8 30 900 JUNCTION 80X SPARE REFRIGERATOR ;#12 -1/2 "C 1200 1P -20 9 10 2P 2500 3 110 -1/2 "C DRYER DISHWASHER #12 -1/2 "C 1500 1P -20 11 12 30 2500 PUMP GARBAGE DISPOSAL 112-1/2-C 720 1 P -20 13 14 1 P -20 * #12-1/2-C BATH RECEPT. GFI WASHER #12 -1/2 "C 1500 1P -20 15 16 1P -20 900 #12 -1/2 "C BATH RECEPT. GFI MICROWAVE #12-1/2-C 1500 1P-20 17 1$ 1 P -15 #14-1/2-C MASTER BEDROOM SMALL APPLIANCE ,#12 -1/2 "C 1500 1P -20 1 19 20 19 20 1 900 MASTER BATH /BEDR. SMALL APPLIANCE #12 -1/2 "C 1500 1P -20 21 22 22 M. BED. /SITTING AREA SMALL APPLIANCE #12 -1/2 "C 1500 1P -20 23 24 BEDROOM KITCHEN HOOD SYST. 720 1 P -20 25 26 27 28 BEDROOM GARAGE DOOR MOTOR 720 29 27 28 HALL /BATH /FOYER FLOOD LIGHTS 32 1050 29 30 33 34 COV.TERR. /LMNG ROOM GARAGE RECEPT. /LTG. 720 35 31 32 LIVING ROOM EXT. RECEPT. GFI. 38 720 33 34 39 40 FAMILY ROOM SPACE 41 35 36 KITCHEN /FAMILY LT. 37 38 25,700 TOTAL = 37,500 11,800 SUBTOTAL TERRACE /DINING 39 40 MASTER BEDROOM 41 42 1 1 SPACE 126,0001 7200 * 2400 AQ. FT. SUBTOTAL 26,850 TOTAL = 52,850 SUBTOTAL DEMAND LOA Q = 52.9 KW FIRST 10 KW 0 100 7. = 10.0 KW 42.9KW040X = 17.16 KW 27.16KW(1 13A) 120/240 150 A.M.L.O. 1 PH-3W PANEL "B" SURFACE M.T.D. BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A A.H.U. - 1 2#4 -1 "C _ 5500 2P 1 2 2P 2750 2#10 -1/2 "C A.H.U. - 2 (1OKW) 0 5500 60 3 4 30 2750 TELEPHONE OUTLET (5 ) C.U.- 1 2 #4 -1 "C (2900) 2P 5 6 2P (2200) 2 #10 -1/2 "C C.U. - 2 (3 TONS.) $3 (2900) 40 7 8 30 (2200) JUNCTION 80X (2.5 TONS.) INSTANT WATER HTR. 2#6, 1 #8 -1 "C. 6000 2P 9 10 2P 1500 #12 -1/2 "C POOL (12KW) 6000 60 11 12 20 1500 PUMP SPARE 900 13 14 1 P -20 600 # 12 -1 /2 "C POOL LIGHTS SPARE 900 15 16 900 LANDSCAPE SPARE 900 17 18 900 SPACE 19 20 1 900 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 SUBTOTAL 25,700 TOTAL = 37,500 11,800 SUBTOTAL A/C 0 100%= 10200 HEAT 0 657*= 10725 (a) (a) (a) 0) DEMAND LOAD = 21.0 KW FIRST 10 KW 0 100 q = 10.0 KW 11.0KW0409 = 4.40 KW = 10.725 KW 25.125KW(105A) LOAD TABULATICN FNL "A' • 113 O FNL.. "8' = 105 216 A 3 e350 MCM THIN (CU) YC -_ - -- _ - - F- L IECTRICAL- NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO. AND AN61/EIA/TIA -570 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM- PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTE$ MODEL ENERGY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. 6. ALL ELECTRICAL WORK SHALL BE PERFOWED BY A LICENSED ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMIT$, CERTICATES OF INSPECTION, A$ REQUIRED. 1. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- NEER AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER 6. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS. CCMBWATICN METER (320A) MAINZ (2) 2P -WA ■ ■ 2 -518" COF"IDER GROUND ROD 10 FT. LONG (MIN. W APART) 3 OVID,1% GRD. THWN (CU) -2'C e2 (CU) - 3/4 "C ■A.PNL I I FNL. Kee MLO MLO 3 01/0, ft GRD. T1" (CU) -2'C CWP(METAL) BLDG. $MEL FOUNDATION NOT AVAILABLE ELECTRICAL R15ER DIAGRAM NTS RISER DIAGRAM, SCHEDULES &NOTES SCALE: N.T.S. 9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERUISE INDICATED. LIKE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MANUFACTURER 10, ALL CONDUCTORS SHALL 15E COPPER AND RUN IN CONDUIT. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 250 -122. II. LOCATION OR OULETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZE$ ARE BASED ON A/C EQUIFMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, A$ WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE NON - AUTOMATIC SWITCH FOR A/C COND. 0I60Cf -MCT. (COMPLY W/NEC 110 -26) 14. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME CKT (KITCHEN OR BATH LTG.) 15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL 4 GROUNDING WIRE PER NEC ARTICLE 250 -140. 16. ALL BEDROOM OUTLETS SHALL BE PROTECTED BY AN "ARC -FAULT CIRCUIT INTERRUPTORVAFCP COMPLY UJITH NEC 210.120) 131010E "MOTOR -% LINE 810E 12OV OF OU11TC44 I OUATCI4 ewitc 4 LEG F PHAtg C HCUCTOR 6MOKE DETECTOR CONNECTION DETAIL NTS. NOTES: I -WOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) TO A NON- 6WItCHABLE LrA4TNO CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER ALL S IOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED(AFCI PROTECTED) 2 -61"OKE DETECTOR SHALL NOT BE PLACED WUITH{N 3FT. OF ANY A/C GRILL. 3 -6MOKE DETECTORS LOCATED OUTSIDE OF 6LEEPING AREAS SHALL NOT BE PLACED CLOSER THAN 3FT. TO BATHROOM DOOR 4 -THE MOUNTING AND LOCATION OF WHIT SMCKE DETECTOR6 $HALL COMPLY WITH NFPA 12 $EC2- 52.16. CEILING MOUNTS NOT LE66 THAN 4' FROM A WALL -WALL MOUNTS NOT LE66 THAN 4' FROM CEILING NOR MORE THA 121 TO TOP OF DETECTOR JOB Ij: 04 -185 GUERRERO /GONZALEZ ENGINEERS, INC. Wkt"el C. Guerroro. P.E. Meth -" Uc. 015235 Rcr.0 L 0!1. oz. P.E. a�ctricd Eng� Ue. 111057 4300 S.W. 73rd Avenue, Swte /107A Miomi, Fiorillo 33155 TeL (305) 282 -3944, Fax (305) 282 -8211 E-mail: PROJECTSOWERRFRO OONZ&EZENGWEERS.COM JOHN R. MEDINA & ASSOC. ARCHITIr(-_ TS 4901 S.W.75th Avenue Miami, Florida 33155 T 305,740.0554 F 305.740.5355 jrmainc @bellsouth.net REVISIONS DATE BY B. D. COMMENTS 11 -29 -04 E W nU1 $ Q U V) U 0 Q 06 CieW V U O !� i i to SEAL and Spmdcafloraas of LEGEND ® SPECIAL RECEPTACLE OUTLET tvMhft`t and 'ha'r°'fr'"P' OdY DUPLEX RECEPTACLE OUTLET 15A. 125V d' SIMPLEX RECEPTACLE OUTLET 15A, 125V O DUPLEX FLOOR RECEPTACLE. 15A, 125V They are not to be used in my an-m on EXHAUST FAN offer projoch or eAen*m to Nib project COMBINATION FAN/ LIGHT + CEILING LIGHTING FIXTURE opproprtate cornpermalion to the A ;I`Aw. FLUORESCENT LIGHTING FIXTURE - SURFACE MTD. 177777 Vo WALL MOUNTED LIGHTING FIXTURE -0--A UNDER CABINET FLUORESCENT LIGHTING FIXTURE IV FL000 LIGHT 0 CEILING MOUNTED LIGHTING FIXTURE DATE: 05117/04 LIGHTING PANEL [�+ FUSE OR DISCONNECT SWITCH TELEPHONE OUTLET N� TELEVISION OUTLET ® SMOKE DETECTOR �0 HI -HAT a,B PUSHBUTTON © CHIME t WALL SWITCH 15A. 1.25V $3 THREE WAY TOGGLE SWITCH FOUR WAY TOGGLE SWITCH r$-41, l� SAFETY DISCONNECT SWITCH Oj JUNCTION 80X OF FAN JOF FAN AND LIGHT(3 -WIRE CKT) /L GFI GROUND -FAULT INTERRUPTER WP WEATHERPROOF LOAD TABULATICN FNL "A' • 113 O FNL.. "8' = 105 216 A 3 e350 MCM THIN (CU) YC -_ - -- _ - - F- L IECTRICAL- NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO. AND AN61/EIA/TIA -570 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM- PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTE$ MODEL ENERGY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. 6. ALL ELECTRICAL WORK SHALL BE PERFOWED BY A LICENSED ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMIT$, CERTICATES OF INSPECTION, A$ REQUIRED. 1. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- NEER AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER 6. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS. CCMBWATICN METER (320A) MAINZ (2) 2P -WA ■ ■ 2 -518" COF"IDER GROUND ROD 10 FT. LONG (MIN. W APART) 3 OVID,1% GRD. THWN (CU) -2'C e2 (CU) - 3/4 "C ■A.PNL I I FNL. Kee MLO MLO 3 01/0, ft GRD. T1" (CU) -2'C CWP(METAL) BLDG. $MEL FOUNDATION NOT AVAILABLE ELECTRICAL R15ER DIAGRAM NTS RISER DIAGRAM, SCHEDULES &NOTES SCALE: N.T.S. 9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERUISE INDICATED. LIKE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MANUFACTURER 10, ALL CONDUCTORS SHALL 15E COPPER AND RUN IN CONDUIT. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 250 -122. II. LOCATION OR OULETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZE$ ARE BASED ON A/C EQUIFMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, A$ WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE NON - AUTOMATIC SWITCH FOR A/C COND. 0I60Cf -MCT. (COMPLY W/NEC 110 -26) 14. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME CKT (KITCHEN OR BATH LTG.) 15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL 4 GROUNDING WIRE PER NEC ARTICLE 250 -140. 16. ALL BEDROOM OUTLETS SHALL BE PROTECTED BY AN "ARC -FAULT CIRCUIT INTERRUPTORVAFCP COMPLY UJITH NEC 210.120) 131010E "MOTOR -% LINE 810E 12OV OF OU11TC44 I OUATCI4 ewitc 4 LEG F PHAtg C HCUCTOR 6MOKE DETECTOR CONNECTION DETAIL NTS. NOTES: I -WOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) TO A NON- 6WItCHABLE LrA4TNO CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER ALL S IOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED(AFCI PROTECTED) 2 -61"OKE DETECTOR SHALL NOT BE PLACED WUITH{N 3FT. OF ANY A/C GRILL. 3 -6MOKE DETECTORS LOCATED OUTSIDE OF 6LEEPING AREAS SHALL NOT BE PLACED CLOSER THAN 3FT. TO BATHROOM DOOR 4 -THE MOUNTING AND LOCATION OF WHIT SMCKE DETECTOR6 $HALL COMPLY WITH NFPA 12 $EC2- 52.16. CEILING MOUNTS NOT LE66 THAN 4' FROM A WALL -WALL MOUNTS NOT LE66 THAN 4' FROM CEILING NOR MORE THA 121 TO TOP OF DETECTOR JOB Ij: 04 -185 GUERRERO /GONZALEZ ENGINEERS, INC. Wkt"el C. Guerroro. P.E. Meth -" Uc. 015235 Rcr.0 L 0!1. oz. P.E. a�ctricd Eng� Ue. 111057 4300 S.W. 73rd Avenue, Swte /107A Miomi, Fiorillo 33155 TeL (305) 282 -3944, Fax (305) 282 -8211 E-mail: PROJECTSOWERRFRO OONZ&EZENGWEERS.COM JOHN R. MEDINA & ASSOC. ARCHITIr(-_ TS 4901 S.W.75th Avenue Miami, Florida 33155 T 305,740.0554 F 305.740.5355 jrmainc @bellsouth.net REVISIONS DATE BY B. D. COMMENTS 11 -29 -04 E W nU1 $ Q U V) U 0 Q 06 CieW V U O !� i i to SEAL and Spmdcafloraas of MR &MRS LANG service ore and t" romafn the property d tvMhft`t and 'ha'r°'fr'"P' OdY RESIDENCE of the Arot#ect whether the project Tar wfifch they ware mode 6 executed or not. They are not to be used in my an-m on offer projoch or eAen*m to Nib project emcW by agreerrw to wAV and %M fhe DEBBIE 8, JOHN LANG opproprtate cornpermalion to the A ;I`Aw. 5941 SW 86 ST Reproduction of dmrMnpr and SOUTH MIAMI, FL 33143 vocrcokm w1txx,t the w Man corm t of CONTAC: DEBBIE LANG the Acct III proWed. PHONE: 305.665.2894 RISER, PANEL & NOTES SCALE: N.T.S. DATE: 05117/04 DRAWN: En r-, v 0 0 N 0 v ru o� rti 0 z 0 o) Jc a co i 0 U3 0 v 0 U3 L CU cu c C c w C-0 Z a i a z H n UJ 'E