04-1517-026TYPICAL 4" CONCRETE SLAB WITH CONTINIOUS 6X6 - 10/10 WWF ON 4' COMPACTED SOIL. CONCRETE POOL N.IC. (REFER TO POLL CONTRACTOR'S DRAWINGS) Iw �--- O Q @ n, i Q w0 J Q cD r V) POOL N.I.C. - POOL CONTRACTORS TO PROVIDE SIGNED AND SEALED SHOP DRWAINGS FOR POOL FOR APPROVAL PRIOR TO COMENCING WORK. 0�1hk 1ru. 110--.1 re %Ar A rrnr,,rjr1/%r POOL SECTION SCALE: 3/4" =1 ' -011 a :a �.. <. 0.' o d - 4 a d s ^IIIIII IIIIII IIIIII�IIIIII . do 'I IIIIII IIIIII 11111 IIIIII IIIIII IIIIII - IIIIII - d — IIIIII IIIIII I IIIIII °°d VIII) , 4' POOL WALL & SLAB CONNECTION SCALE: I " =1' -0" TYPICAL 4' CONCRETE SLAB WITH CONTINOUS 6X6- 10 /10 WWF ON 4" COMPACTED SOIL. TYPICAL NATURAL STONE COPING WITH ROUNDED EDGE CONDITION OR AS PER INTERIOR DESIGNER SPECIFICATIONS. 3/4" EXPANSION JOINT WITH WATERPROOF CAULKING. - ��_-- WATER LINE POOL WALL POOL BY OTHERS. POOL CONTRACTOR TO VERIFY CONFORMANCE OF POOL COPING AND POOL PERIMETER TILE TO MARBLE PLASTER FINISH (MARCITE) PRIOR TO INSTALLATION. CONNECTION TO BE WATERPROOF. POOL &JACUZZI EDGE DETAIL SCALE: 1 " =1' -011 SOD. YPICAL TRAVERTINE COPING KITH ROUNDED EDGE ,ONDITION (1.5" BULLNOSE). YPICAL 4' POOL WALL ZEFER TO STRUCTURAL DRAWINGS JOINT WITH WATERPROOF CAULKING. 3 ,V SMOOTH FINISH STUCCO. MARSITE CONCRETE POOL WALL POOL CONTRACTOR TO VERIFY CONFORMANCE OF POOL COPING AND POOL PERIMETER TILE TO MARBLE PLASTER FINISH (MARCITE) PRIOR TO INSTALLATION. CONNECTION TO BE WATERPROOF. POOL AND JACUZZI BY OTHERS. 7ENERAL POOL NOTES 1. INSTALL NEW POOL PUMP, FILTER, & HEATING EQUIPMENT IN EXISTING CABANA.PROJECT MANAGER TO INSTRUCT G.C. OF EXACT LOCATION OF EQUIPMENT. G.C. TO PROVIDE NEW CIRCULATING PUMP, FILTER, HEATER, PLUMBING, ELECTRICAL, & ALL ANSCILLARY FITTINGS REQUIRED FOR POOL & JACUZZI. 2 PUMP EQUIPMENT INCLUDING FILTER &/OR HEATER SHALL BE LOCATED ABOVE THE REQUIRED BASE FLOOD ELEVATION OR FLOOD PROOFED. 3. ALL POOL CONSTRUCTION SHALL CONFORM TO CHAPTER 50 OF SOUTH FLORIDA BUILDING CODE. 4. POOL & PATIO SHALL BEAR ON ROCK OR CLEAN SAND WHICH SHALL BE COMPACTED TO PROVIDE A STRUCTURALLY SAFE BEARING CAPACITY. ALL UNSUITABLE MATERIAL ENCOUNTERED IN EXCAVATION SHALL BE REMOVED IN ITS ENTIRETY AND THE AREA SHALL BE BACK FILLED WITH ACCEPTABLE MATERIAL AND PROPERLY COMPACTED. 5. CONCRETE MAYBE PNEUMATICALLY APPLIED OR POURED IN PLACE IN POOL FLOOR, WALL AND STEPS. CONCRETE SHALL DEVELOP A STRENGTH OF 3000 PSI IN 28 DAYS, IN OPTIONAL POOL DECK 2,500 PSI. 6. ALL REINFORCING STEEL SHALL CONFORM TO ASTM 815 GRADE 60. REINFORCING SHALL BE NO 3 BARS AT 10" O.C. EACH WAY. BELOW 7', SPACING SHALL BE 6" O.C. EACH WAY. 7. ALL METALLIC POOL FITTINGS WITHIN 5' OF THE INSIDE WALL & THE DECK REINFORCING STEEL SHALL BE BONDED TO THE POOL REINFORCING STEEL WITH A NUMBER 8 AWG COPPER WIRE. THE POOL REINFORCING STEEL SHALL BE BONDED TO THE POOL LIGHT NICHE WITH A # 8 AWG COPPER WIRE. 248 AWG COPPER WIRES SHALL BE RUN WITH THE NEC APPROVED CONDUIT, ONE INTERNALLY, FROM THE LIGHT NICHE TO THE JUNCTION BOX. COMPLETION OF THE POOL GROUNDING SYSTEM TO THE PANEL BOARD BY ELECTRICIAN. 7A. INSTALLATION OF JUNCTION BOXES, GROUNDS, ETC SHALL BE IN ACCORDANCE WITH 680 OF THE NATIONAL ELECTRIC CODE. POOL LIGHTS MUST BE INSTALLED IN STRICT ACCORDANCE WITH THE SFBC & SUBJECT TO ELECTRICAL INSPECTION. POOL LIGHTS MUST BE 12V. 8. ALL PIPING SHALL BE N.S.F. APPROVED AND SHALL BE SCHEDULE 40 PVC EXCEPT WHERE OTHERWISE NOTED. SHORT 90 DEGREE BENDS ARE NOT PERMITTED IN SUCTION LINES. 9. PUMP & FILTER MAYBE RELOCATED IN FIELD UPON PRIOR PERMISSION BY OWNER. 10. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL UTILITIES IN RELATION TO THE POOL AND ITS EQUIPMENT SHALL INSURE MIN. CLEARANCE REQUIREMENTS IN ACCORDANCE WITH ALL LOCAL REGULATIONS. 11. THE CONTRACTOR SHALL PROTECT ALL EXISTING STRUCTURES FROM DAMAGE AND OR FAILURE BY ACCEPTABLE METHODS, AS MAY BE REQUIRED. 12. WARNING; DRAINING THE POOL FOR ANY REASON, WITHOUT ELIMINATING THE HYDROSTATIC UPLIFT PRESSURE MAY RESULT IN SERIOUS DAMAGE THE OWNER IS ADVISED TO CONSULT AN EXPERIENCED POOL CONTRACTOR TO COMMENCING DRAINING THE POOL. 12A POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH SFBC. 12B MAIN DRAIN SHALL HAVE AN ANTI - VORTEX GRATE (6" SQUARE MINIMUM OPEN AREA AND HYDROSTATIC VALVE) 13. CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION & RELOCATION OF ALL UNDERGROUND UTILITY LINES (I.E., GAS, WATER, ELECTIRCAL ETC.) IN THE PATH OF CONSTRUCTION. 14. THE OWNER SHALL PROVIDE A SCREEN ENCLOSURE, FENCE, OR WALL WITH SELF CLOSING & SELF LATCHING GATE IN ACCORDANCE WITH CODE REQUIREMENTS. 15. CONTRACTOR TO INSTALL A 24 HOUR TIMER FOR PUMP AS PER FLA STATE ENERGY CODE # 505.2. JOHN R. MEDINA & ASSOC. ARC F-I ITECTS 4901 S.W.75th Avenue Miami, Florida 33155 T 305.740.0554 F 305.740.5355 jrmainc @bellsouth.net REVISIONS DATE U" 0 O 0 U Q nV) W V U O V) 1c: V W S.. V U_ 0! 0 t BY one [SEM Drawings and Specifications as inslnument of MR & MRS LANG service are and shall remain the properly of the Architect and shall remain the properly RESIDENCE of the Architect whether the project for which they were made is executed or not. They are not to be used in any manner on other projects or extensions to this project except by agreement in writuig and with the DEBBIE & JOHN LANG appropriate compensation to the Architect. 5941 SW 86 ST Reproduction of drawings and SOUTH MIAMI, FL. 33143 specifications without the written consent of CONTACT: DEBBIE LANG the Architect is prohibited. PHONE: 305.665.289-4 POOL SECTION & DETAILS SCALE: 3/4!'= 1' -0" DATE: 10/04 DRAWN: CAP one