08-603-030r ELEEC77FRIf CAL N077,1:� I. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL 4PPLICA5LE LOCAL CODES_ 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMfi ANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER FBC 4502.2(,4)(11) AND ANSI /EI4/TIA -510 STANDARD. 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN C01'1- PLIANCE AS SET FORTH Bl' STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS, 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION, AS REQUIRED, 7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NEGE55ARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- NEER. AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER. 8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS, GROUND INTO ELECTRODE CONDUCTOR BOLTED -TYPE p CONNECTION DEVICE o OR EXOTHERMIC WELD. 0 NONMETALLIC GROUNDINCs PROTECTIVE ELECTRODE SLEEVE CONCRETE FOUNDATION • • No_ 4 AWG OR LARCsER FARE • Of -F'ER CONDUCTOR OR STEEL REINFORCING PAR OR ROD NOT LESS THAN 112 - INCH DIAMETER. 2 fn. MIN. g. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED_ LIKE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MANUFACTURER. 10. ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS_ PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 250 -122. I1_ LOCATION OR OULETS IN ELECTRICAL DRAWINGS 15 DI4GR4MP'114TIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL 1`4NEL50ARD5. COMPLY W/FBC 4504.4. 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON - TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C. EQUIF''MENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES, USE NON - AUTOMATIC SWITCH FOR A/C COND. DISCONNECT, (COf'1PLY W/ NEC 110 -2ro) CONNECT TO A CONCRETE- ENCASED ELECTRODE CONSISTING OF AT LEAST 20 FT OF ONE OR MORE BARE OR ZINC GALVANIZED STEEL REINFORGINCz BARS OF NOT LESS THAN 112 INCH OR CONSISTING OF AT LEAST 20 FT. OF BARE COPPER CONDUCTOR NOT SMALLER THAN No. 4 AND LOCATED WITHIN AND NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTING THAT 16 IN DIRECT CONTACT WITH EARTH, LEG4 END FLUORESCENT LIGHITING FIXTURE - SURFACE MTD. o WALL MOUNTED LIGHTING FIXTURE __., � SPECIAL RECEPTACLE OUTLET 1V DUPLEX RECEPTACLE OUTLET 154,125V G- SIMPLEX RECEPTACLE OUTLET 154,125v L:;;� DUPLEX FLOOR RECEPTACLE, 154, 125V O EXHAUST FAN 2004 CEILING LIGx 4TING FIXTURE FLUORESCENT LIGHITING FIXTURE - SURFACE MTD. o WALL MOUNTED LIGHTING FIXTURE __., � UNDER CABINET FLUORESCENT LIGHTING FIXTURE 1V FLOOD LIGHT O CEILING MOUNTED LIGHTING FIXTURE L:;;� LIGHTING PANEL O JUNCTION BOX 2004 FUSE OR DISCONNECT SWITCH o TELEPHONE OUTLET a COMPUTER OUTLET TV TELEVISION OUTLET Sp SMOKE DPTFCTOR HI -HAT �PB PUSHBUTTON V CH IME , WALL SWITCH 15A, 1-25V THREE WAY TOGGLE SWITCH � FOUR WAY TOGGLE SWITCH []1 5AFETY p15CONNECT SWITCH LNC ,45LD fROUND II V LECT�O E D TA L its E/L FAN AND LIGHT G1-I GROUND -FAULT INTERRUPTER 4'W x S'H x 3/4" - PAINTED TELEPHONE BOARD 5-12 rc AWG 18 " -24" C MIN, TO ACH SPACE F CONTRACTORR TO 57U5 UP TELEPHONE CONDUIT ON BOTTOM 2 - 2'' CONDUIT TO P COORDINATE LEFT CORNER OF TELEPHONE PLYWOOD LOCATION WITH SBT. 7ELEEFHONE i;lSE-z�� NT5 ITEMS TO BE FOR TELL HONE &EFVICFz I. 110 VAC DUPLEX RECEPTACLE 2, EXTENSION OF AN APPROVED COLD WATER PIPE OF *6 AWG TO COLD WATER PIPE. 3, 4'W x 8'H x 3/4'' PAINTED TELEPHONE PLYWOOD. 4. ALL CONDUITS TO BE EQUIPPED WITH PULL STRINGS. GENERAL NOBS_ THE COMPLETE SET OF CONSTRUCTION DOCUMENTS CON515T5 OF DRAWINGS, DFTAILS 4 SPECIFICATIONS_ IN THE EVENT OF A DISCREPANCY, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEERS FOR CLARIFICATION. ANY DEVIATION FROM THESE DRAWINGS, WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT AND/OR ENGINEERS IS PROHIBITED. GENERAL CONTRACTOR OR SUBCONTRACTORS ASSUMES FULL RESPONSIBILITY FOR ANY UNAUTHORIZED DEVIATION FROM THE INFORMATION DEPICTED IN THE CONSTRUCTION DOCUMENTS, ENGINEERS ARE NOT RESPONSIBLE OR LIABLE FOR ANY D15CREFANCY BETWEEN THESE DRAWINGS AND THE EXISTING CONDITIONS. ANY WORK PERFORM ON THE PROPERTY PRIOR THESE CONSTRUCTION DOCUMENTS AND WILL NOT MATCH WITH THE INFORMATION IN THE EXISTING CONSTRUCTION DOCUMENTS ON CITY RECORDS OR IT WAS NOT V1515LE AT 71ME OF INSPECTION OR THE WORK WAS DONE ILLEOALLY WITHOUT PERMIT BY OTHERS AND WILL CAUSE A DISCREPANCY WITH THE NEW DRAWINGS IS THIZ RESPONSIBILITY OF THE CURRENT OWNER OF THE PROPERTY AT HIS OWN EXPENSE TO PERFORM ALL THE NECESSARY CORRECTIONS IN ORDER THAT ALL WORK IS IN ACCORDANCE WITH THE CURRENT FLORIDA BUILDING CODE AND THE LOCAL ORDNANCE AND WILL MATCH W17H THE NEW CONSTRUCTION DOCUMENTS FOR WHICH WORK WILL BE PERFORM. NOTE: BEFORE START TO WORK ON THIS JOB ALL EXI5TING MECHANICAL WORK SHALL BE VERIFY BY MECHANICAL CONTRACTOR AND GENERAL CONTRACTOR, IN CASE ANY DISCREPANCY BETWEEN PLANS AND EXISTING CONDITIONS CONTRACTORS SHALL CONTACT IMMEDIATELY THE PROFESSIONAL DESIGNFR AND THE PROFESSIONAL DESIGNER SHALL MAKE ALL NECESSARY GHIANG ES. AT ANY MOMENT CONTRACTORS ARE ALLOW TO ASSUME ANY CHANCsES WITHOUT THE WRITTEN CONSENT ON PROFESSIONAL DESIGNER AND ALL REQUEST SHALL eF DONE BY WRITING. ANY DEVIATION WITHOUT THE WR171NCs CONSENT OF PROFESSIONAL DESIGNER IS PROHIBITED. IF CONTRACTORS PERFORM ANY CHANGE OR CORRECTION WITHOUT COMMUNICATING THE PROFESSIONAL DESIGNER CONTRACTORS SHALL ASSUME ALL RESPONSIBILITIES IN CASE ANY PROBLEM IS ENCOUNTER. FINAL CONSTRUCTION PRICE SHALL NO BE AGREE UNTIL CONTRACTORS VISIT JOB SITE AND COMPARE APPROVED PLANS WITH THE EXISTING CONDITIONS, IN CASE PRICE 15 ACsREE AND CONTRACTORS CHOOSE NO TO VISIT THE SITE IS HIS /HER TOTAL RE51`DONSI5I1-17I' ANY D15CREPANCY FOUND DURING CONSTRUCTION, A CONSTRUCTION PRICE SHALL ONLY BE GIVEN BY APPROVED PLANS FOR LOCAL AUTHORITIES. IN CASE A PRICE IS AGREE AND THE PLANS USED AS REFERENCE ARE NOT THE ONES APPROVED BY LOCAL AUTHORITIES WITH THE STAMPS FROM CITY OR COUNTY IS THE TOTAL RESPOSABILITY OF CONTRACTRORS TO ASSUME ALL NECESARY COST ON CHANGES NEED IT TO BE PERFORM. TWO SETS OF 3 *350 MCM THWN IN EACI HGOND. F ELEGTfRf CAL e NFFAL NCTF5 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECE55ARY FOR THE INSTALLATION OF A COMPLETE ELECTRICAL SYSTEM IN ACCORDANCE W/ THESE DRAWINGS, THE SOUTH FLORIDA BUILDING CODE, THE NATIONAL ELECTRICAL CODE, OSHA, AND ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL CODES AND / OR ORDINANCES, 2. THE CONTRACTOR SHALL PAY ALL C05T OF PERMIT, INSPECTIONS AND ALL OTHER COST INCIDENTAL TO THE COMPLETION AND TESTING 017 THIS WORK. 3. THE MATERIAL, INSTALLATIONS AND WORKMANSHIP FURNISHED UNDER THIS CONTRACT SHALL CONFORM AT LEAST TO THE REQUIREMENTS OF LOCAL CODES AND N.E.C. ALL MATERIALS USED SHALL BE NEW AND SHALL BE LISTED AND / OR BEAR U.L. APPROVAL. 4, ALL CONDUCTORS SHALL CON5157 OF 98% CONDUCTIVITY COPPER. ALL CABLES SHALL BE SINGLE CONDUCTOR, 600 VOLT, THERMOPLASTIC INSULATION, SUITABLE FOR CONTINUOS OPERATION AT 75 DEGREES C. CONDUCTOR TEMPERATUFZE IN BOTH WET AND DRY LOCATIONS. THIE5E CABLES SHALL BE N.E.C. INSULATION CLAe51FIG4TION TYPE THWN OR TWN, EXCEPT FOR 4WG SIZES 1110 AND SMALLER TYPE TW MAY BE USED. ALL CONDUCTOR INSULATION SHALL BE COLOR CODED, COLORED INSULATION SHALL BE U5ED FOR AWG SIZES *6 AND 5f" FALLER ANp APPROVED COLOR TAPE5 SHALL BE USED FOR AWS 61ZES 114 AND LARGER. 5, ALL FLEXIBLE CONDUIT SHALL HAVE A GREEN BOND GONE) UGTOR INSTALLED TOGETHER W/ CIRCUIT CONDUCTORS. P.V.G. CONDUIT MAY BE USED IN UNDERGROUND LOCATION5, BUT ALL STUB -UPS MUST BE DONE W/ RIGID GALVANIZED STEEL CONDUITS, PROVIDE A GREEN BOND CONDUCTOR SIZED PER ARTICLE 250 OF THE N.E.C_ IN ALL P.V.C. CONDUITS, 6_ ALL ELECTRICAL PANELS, GIRCU17 5REAKER5, SAFETY SWITCHES, ETC. SHALL BE SQUARE D OR APPROVED EQUIVALENT, PANEL DIRECTORIES SHALL BE TYPED. CIRCUIT BREAKERS MAY BE INSTALLED IN ANY ORDER WITHIN PANEL50ARD5, 7. ALL FEEDERS AND BREAKERS SHALL BE CoaRDINATED W/ EQUIPMENT NAMEPLATE AT SITE. PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CHECK NAMEPLATE DATA OF EQUIPMENT TO OBTAIN CORRECT CONDUCTOR SIZES AND OVER CURRENT PROTECTION. 8. ELECTRICAL INSTALLATION OF THE WORK SHOWN HERE SHALL BE IN COMPLIANCE W/ THE STATE OF FLORIDA ENERGY CODE. °�. LOCATIONS OF OUTLETS ON ELECTRICAL DRAWINCsS ARE DIAGRAMATIC, CHECK MANUFACTURER'S DRAWINGS FOR EXACT LOCATION OF OUTLET5, 10, ALL LIGHING FIXTURES SHALL BE PROVIDED WITH BU55 FUSE HOLDER TYPE HLR AND GLR DUAL ELEMENT FUSES. PROJECT DESIGN BASED ON FLORIDA BUILDING CODE 3 *6 THWN IN 3/4" CON 2/60 CxEN I G 1 0 1.5 KW 2600A L 600 A EXISTNG MAIN IOFI 120 /240- IPH -3W NEMA 3R (000 A 22000 A/C INTEGRAL RATING TWO SET5 OF 3 *350 MGM THIWN IN 3" COND. GUTTER -WP 12 "X12" TWO SETS OF 3 *3/0 THWN OIN 2" COND EAZH. TWO SETS OF 3 *3/0 THWN IN 2" CONE) EAZH. 40014 3"3/0 THWN 10 CONE) 1 NERM4 N32" CS) ft 0 PNL 114" C7 PNL 115" 2004 Z o fT0 PNL "E" EACH L114 < AL L_3 *6 THWN TRANSFER IN 3/4" COND 310 (CU)- 3/4" COND. L SWITCH — -�- : �.. COLD WATER PIPE (METAL) BLDG. FOUNDATION (STEEL) 5 /8 'XIO' COOPERCLAD GROUND RODS EL E C;7FIC;4L F-,,, 1,5 �D f ACT F,, A nts CITY OF SOUTH i'LIIAN11 BUILDING DEPT. ELECTRICAL SECTION APPROVED BY: !QATC To the best of my knowledge subject drawing comply with FBC. Dade County require c Final Letter of Compliance from Architect. ArWa4i� iq'�coPubl�,-fcta rr @�YlgF�n by Architect /Engineer. Contractor or subcontractor shall notify Architect prior any change to be done on approved drawings. Revision I� LLI 7C LLI 7 N U� W G.. 0 0 Q Z W U- M cb� 3"3/0 THWN W IN 2" COND O CS) 3 *3/0 THWN C7 IN 2'' CONE) 2004 Z I+ � NEMA � Y LU Z- � Z 0 HM =) J = � 3 *3/0 THWN IN 2" COND ZZ 0- _� TO PNL "C" EACH L114 < AL L_3 *6 THWN TRANSFER IN 3/4" COND 310 (CU)- 3/4" COND. L SWITCH — -�- : �.. COLD WATER PIPE (METAL) BLDG. FOUNDATION (STEEL) 5 /8 'XIO' COOPERCLAD GROUND RODS EL E C;7FIC;4L F-,,, 1,5 �D f ACT F,, A nts CITY OF SOUTH i'LIIAN11 BUILDING DEPT. ELECTRICAL SECTION APPROVED BY: !QATC To the best of my knowledge subject drawing comply with FBC. Dade County require c Final Letter of Compliance from Architect. ArWa4i� iq'�coPubl�,-fcta rr @�YlgF�n by Architect /Engineer. Contractor or subcontractor shall notify Architect prior any change to be done on approved drawings. Revision I� LLI 7C LLI 7 N U� W G.. 0 0 Q Z W U- M cb� W W CS) C7 � ill Z W o � � Y LU Z- � Z 0 HM =) J = � II C-4 W ZZ 0- w N �,Q) V ( , H0LO �?Q QJCC3 C>IV V vmxuj � II CD U-5 0 W 4 0 N L) 11-- LL Li `& c47 W W W Z_ C7 Z �? Z W o � � Y LU Z- � Z 0 HM =) J = = LL C/? LL b M C-4 W ZZ 0- w N �,Q) V to ° Z H0LO �?Q QJCC3 C>IV V vmxuj CD U-5 0 W 4 0 N L) 11-- LL Li DRAWN BY= L F -- R O Checked: F. G -P Date: Scale: 'ShoLun !l-7Trd 11 Sheet: fE =:::: 2 OF e