08-603-026AlR COND1710NN'S SCHEDULE UNIT MANUFACTURER AND MODEL NO. NOM. TONS NOM. CFM ESP IN. WCz. ELECT. HEAT KW TOTAL FLA /HP COOLING CAP. S/T BTUH w 95' 4 Col' W O/A CFM DIMENSIONS WxLxH (IN.) WEIGHT 1-156- ELECT. SERVICE VOLT5/PH /Hz SEER AHU *243 RHEEM- RHLA- HM&024JA -- -- 2000 40 �.5 4,6/3/4 - - -- 400 25x22x56 198 208- 230/1/60 13.5 CU *1,2 t3 RHEEM- RAND60J5Z 5 - - -- - - -- - --- 26.5 40100/59,000 - - -- 43x32x33 240 208- 23011160 1 1 � 12 %x12 ;xll % 5m 4 V • AS REQUIRED TO OPERATE QUIETLY 50 THAT NO05JECTIONA51-E SOUND 0 • PARTITION ' rl d RETURN AIR DUCT RECTANGULAR CROSS SECTION SC EEN 4 ROOF CAP PERFORATED CAP FOR TURNING VANE 48 A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS By VENT, 12" HIGH W /GRILLE, 4 "4, DUCT EF*2 CARNE8- VGDDOO8C 1500 • i0 • I /S" 120/1/60 NOTI =: OR EQUIVALENT EQUIPMENT MECHANICAL ATTACH PLENUMS AND RI =TUF�N W/FLEXIBLE CONN,- \ REFRIGERANT LINES TO OUTSIDE C:ONDEN51NCz UNIT THRU ATTIC SPACE 3/4" CONDENSATE DRAIN w/ 3" TRAP UNION AND G.O TO GREEN AREA GALV. STEEL A.H.U. SUPPORT (SELF- STANDINCz) NO COMBUSTIBLE MATERIALS WITHIN A.H.U. ROOM R/A THRU LOUVER DOOR �—► R/A THRL POWER 24 VDC OR 120 VAC U.L.L ISTED YES FAN SC�4EDULE SUPPLY DUCT THRU ROOF W /GAP. •••Yi FIRE DAMPER (S) MANUFACTURER x WATT • ELECT. SERVICE DIMENSIONS WEIGHT x FAN AND MODEL NO. RPM HP CFM a S.P. VOLTS /PH /Hz WXLXH (IN.) LBS. REMARKS N RETURN AIR GRILLE • 102 4 V.D COOLING - i6' DB 91 DB - -s WB 50% TO 60% BAGKDiR4FT DAMPER EFL CARNES- VGDD015G 1500 DD TROUBLE LIGHT 110 1/8 120 /I /G�0 1 1 � 12 %x12 ;xll % 5m 4 V • AS REQUIRED TO OPERATE QUIETLY 50 THAT NO05JECTIONA51-E SOUND 0 • PARTITION ' rl d RETURN AIR DUCT RECTANGULAR CROSS SECTION SC EEN 4 ROOF CAP PERFORATED CAP FOR TURNING VANE 48 A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS By VENT, 12" HIGH W /GRILLE, 4 "4, DUCT EF*2 CARNE8- VGDDOO8C 1500 • i0 • I /S" 120/1/60 gx81�25x1/4 40 BACKDRAFT DAMPER 4 SECONDARY W V THERMOSTAT 5' -0" ABOVE FINISHED FLOOR, U.C.N. V FLEXIBLE ROUND DUCT 7. DRAIN V i i V SCREEN 4 ROOF GAP NOTE: OR EQUIVALENT EQUIPMENT FUSERS TO HAVE OPOSED BLADE DAMPERS. PROVIDE GASKETS V W V PROVIDE 4" CLEARANCE MECHANICAL ATTACH PLENUMS AND RI =TUF�N W/FLEXIBLE CONN,- \ REFRIGERANT LINES TO OUTSIDE C:ONDEN51NCz UNIT THRU ATTIC SPACE 3/4" CONDENSATE DRAIN w/ 3" TRAP UNION AND G.O TO GREEN AREA GALV. STEEL A.H.U. SUPPORT (SELF- STANDINCz) NO COMBUSTIBLE MATERIALS WITHIN A.H.U. ROOM R/A THRU LOUVER DOOR �—► R/A THRL POWER 24 VDC OR 120 VAC U.L.L ISTED 24x24 RACE 2 "A /C CD. UNDI =RSLAB AIR HANDLER UNIT INSTALLATION DETAIL NO SOLE FROM OTHER DETECTOR (IF APPLICABLE) IONIZATION SMOKE DETECTOR (SEE HVAC PLANS) DETECTOR TEST PANEL OR FIRE ALARM PANEL IF APPLICABLE LIGHT I - — (,F r 11-1 INDICATOR \�i ��/� Ir 4/ EVAPORATOR FAN MOTOR AUXILIARY CONTACT TO SHUT DOWN UNIT IN CASE OF SMOKE SENSING AIR CONDITIONING DUCT SMOKE DETECTOR FOR UNITS EVER 2000 GPM ROOF GAP. INSECT SCREEN BASE AIR FLOW ��S/M 26 G. SIZE DEPEND OF TYPE OF FAN SEE FAN SCHEDULE. EXHAUST DUCT EXHAUST FAN 4 DUCT- DETAIL N.T.S. LOW VELOCITY ^� SUPPLY AIR DUCT (SEE PLAN VIEW) INSUL R -ro METAL ROUND FITTING QUADRANT OPERATOR TO 18E OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY INSULATED FLEX. DUCT. / 11/2" F /GWTH POLYETHELENE JACKETAND STEEL WIRE REINFORCING(R -ro) AIR FLOW SEAL JOINT WITH EPDXY 4 DUCT TAPE HVAC DESIGN REQUIRES: YES 12 "* O/A DUCT SUPPLY DUCT THRU ROOF W /GAP. •••Yi FIRE DAMPER (S) THE FABRICATION AND INSTALLATION OF THE SYSTEM - x SMOKE DAMPER(S) • x FIRE RATED ENCLOSURE V • x CEILING ® x FIRE 5TOPPING THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY CLC SMOKE CONTROIL y- i:�J o N RETURN AIR GRILLE • S 4 V.D COOLING - i6' DB 91 DB - -s WB 50% TO 60% O THERMOSTAT y HEATING - 10' DB 41' - DB DD TROUBLE LIGHT U 4- ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, ♦ • (IN OCCUPIED AREA) V • AS REQUIRED TO OPERATE QUIETLY 50 THAT NO05JECTIONA51-E SOUND 0 • PARTITION ' rl d RETURN AIR DUCT RECTANGULAR CROSS SECTION • PERFORATED CAP FOR TURNING VANE 5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS By VENT, 12" HIGH REQUIRED FOR EASY AGGE5515ILITY. co VOLUME DAMPER, IN LINE HCD`nin • "•Revision n ro. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT lie SECONDARY W V THERMOSTAT 5' -0" ABOVE FINISHED FLOOR, U.C.N. V FLEXIBLE ROUND DUCT 7. DRAIN V i i V i• W•• FUSERS TO HAVE OPOSED BLADE DAMPERS. PROVIDE GASKETS V W V PROVIDE 4" CLEARANCE ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREGUIDE OR APPROVED EQUAL R/A WHITH ENAMEL FINISH PLENUM p 8. UNDERCUT DOORS 1" A.F.F., FOR R/A FOR ROOMS WITH LESS THAN 110 CFM ALL AROUND AHU III FOR ROOMS WITH OVER 110 CFM PROVIDE F'A.6. AND TRANSFER DUCT. 0 FAN FLOAT SWITCH V.D S. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - • DRAIN PAN �--- --� FIRE DAMPER y WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH U V • I---- FLOOR 24x24 RACE 2 "A /C CD. UNDI =RSLAB AIR HANDLER UNIT INSTALLATION DETAIL NO SOLE FROM OTHER DETECTOR (IF APPLICABLE) IONIZATION SMOKE DETECTOR (SEE HVAC PLANS) DETECTOR TEST PANEL OR FIRE ALARM PANEL IF APPLICABLE LIGHT I - — (,F r 11-1 INDICATOR \�i ��/� Ir 4/ EVAPORATOR FAN MOTOR AUXILIARY CONTACT TO SHUT DOWN UNIT IN CASE OF SMOKE SENSING AIR CONDITIONING DUCT SMOKE DETECTOR FOR UNITS EVER 2000 GPM ROOF GAP. INSECT SCREEN BASE AIR FLOW ��S/M 26 G. SIZE DEPEND OF TYPE OF FAN SEE FAN SCHEDULE. EXHAUST DUCT EXHAUST FAN 4 DUCT- DETAIL N.T.S. LOW VELOCITY ^� SUPPLY AIR DUCT (SEE PLAN VIEW) INSUL R -ro METAL ROUND FITTING QUADRANT OPERATOR TO 18E OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY INSULATED FLEX. DUCT. / 11/2" F /GWTH POLYETHELENE JACKETAND STEEL WIRE REINFORCING(R -ro) AIR FLOW SEAL JOINT WITH EPDXY 4 DUCT TAPE HVAC DESIGN REQUIRES: YES NO DUCT 'SMOKE DETECTOR x •••Yi FIRE DAMPER (S) THE FABRICATION AND INSTALLATION OF THE SYSTEM - x SMOKE DAMPER(S) • x FIRE RATED ENCLOSURE V • x FIRE RATED ROOF/FLOOR CEILING A55FM131-Y ® x FIRE 5TOPPING THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY x SMOKE CONTROIL a� II x AIR CONDITIONING SYSTEM - GENFRAL NOTES: 1. DUCTWORK SHALL BE 1 1/2" THICK, 3 POUNDS PER CUBIC FOOT DENSITY FIBERGLASS WITH VAPOR BARRIER, UNLESS OTHERWISE SPECIFIED. DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURI =R'S 8PECIFICATION5 AND ACCORDING TO "ASHRAE" AND "SMACNA" STANDARDS. DUCT DIMEN5IONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY WITH "NFPA" STANDARD NO. 90A AND /OR 908. DUCTWORK AND COMPONENTS SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 TESTS. 2, COORDINATE LOCATIONS, 517E5 AND OPENINGS WITH OTHER TRADES N THE JO A/C CONTRACTOR •.SHALL PROVIDE THE COMPLETE DUCT ANGLE IRON SCREEN REINFORCING \ WHERE REQUIRED METAL BOLT SCR55N FRAME AIR FLOW ADJUSTABLE VOLUME DAMPER — SEAL JOINT WITH EPDXY 4 DUCT TAPE PERFORATED DIFFUSER TYf=ICAL DIPPUSER CONNECTION DEVIL NO SCALE AUDIBLE ALARM CONDENSING IT IN NORMALLY OCCUPIED AREA OR THROUGH . BUILDING FIRE ALARM 5Y5TEM IF APPLICABLE PIPE INSULATION-7 CONCRETE PAD 4" THICK MIN REFRIGERANT LINES TO AIR HANDLER ANCHOR W /POWER DRIVEN STUDS OR THRU CEILING SPACE 3/8"X1.5 "LG. TAP -CONS, OR LAG BOLTS W/ SHIELDS INSIDE G.U. THRU BASE PLATE TO WITHSTAND WINDS OVER 146 MPH WITH AN ANCHOR BOLT OF 500 POUNDS MINIMUM PULL OUT CAPACITY. CONDENSING UNIT INSTALLATION DETAIL NO SCALE FASTENERS r-AW3LE RIVITI =D OR SPOT WELDED AS REQUIRED 180' MIN. R/ STANDARD DUCT MADE WATER TIGHT STIFFERNERS MAY BE IN51DE. 50/50 SOLDC-_R USED AT ALL JOINTS EXPOSED TO WEATHER PREPARE GALVANIZED FINISH I } FOR A COAT OF 3 MIN, ALUMINUN PAINT I W••V VUV MAX. SPACING O B. SYSTEM A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TRADE IN • •••Yi •Yu THE FABRICATION AND INSTALLATION OF THE SYSTEM - HVAC LEGEND • 4 W ii s V V • 3. DIFFUSERS SHALL BE SELECTED, LOCATED, AND BALANCED IN ORDER ® SUPPLY AIR DIFFUSER V THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY V U y a� II AND DRAFT FREE To MAINTAIN THE FOLLOWING DESIGN CONDITIONS: N RETURN AIR GRILLE • INSIDE OUTSIDE RELATIVE HUMIDITY 4 y W V V W COOLING - i6' DB 91 DB - -s WB 50% TO 60% O THERMOSTAT y HEATING - 10' DB 41' - DB V U 4- ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, ♦ • SUPPLY AIR DUCT RECTANGULAR GROSS SECTION V • AS REQUIRED TO OPERATE QUIETLY 50 THAT NO05JECTIONA51-E SOUND 0 • • WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, d RETURN AIR DUCT RECTANGULAR CROSS SECTION • MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT. TURNING VANE 5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS By o •' REQUIRED FOR EASY AGGE5515ILITY. VOLUME DAMPER, IN LINE HCD`nin • "•Revision ro. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT lie VOLUME DAMPER, AT TAKE OFF W V THERMOSTAT 5' -0" ABOVE FINISHED FLOOR, U.C.N. V FLEXIBLE ROUND DUCT 7. ALL GRILLS AND DIFFU6ER5 TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF- V i i V i• W•• FUSERS TO HAVE OPOSED BLADE DAMPERS. PROVIDE GASKETS V W V ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREGUIDE OR APPROVED EQUAL SPUTTER DAMPER WHITH ENAMEL FINISH p 8. UNDERCUT DOORS 1" A.F.F., FOR R/A FOR ROOMS WITH LESS THAN 110 CFM � FOR ROOMS WITH OVER 110 CFM PROVIDE F'A.6. AND TRANSFER DUCT. 0 FAN S. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - • ACR TYPE, DEHYDRATED AND `'SEALED. ALL FITTINGS SHALL BE �--- --� FIRE DAMPER y WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH U V • TEMPERATURE BRAZING ALLOT' OF NOT LESS THAN 5% SILVER • SMOKE DETECTOR PIPING INSTALLATION NOT LESS THAN 3/4" THICK "ARMAFLEX ". U Y•• • LIQUID AND SUCTION LINE'S SHALL BE SIZED ACCORDING TO >R >< OPPOSED BLADE DAMPER EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY EQUIPMENT MANUFACTURER. ALL PIPING SHALL BE EVACUATED PER GOOD ELECTRIC STRIP HEATER PIPING PRACTICE BEFORE START -UP. MOTORIZED DAMPER ANGLE IRON SCREEN REINFORCING \ WHERE REQUIRED METAL BOLT SCR55N FRAME AIR FLOW ADJUSTABLE VOLUME DAMPER — SEAL JOINT WITH EPDXY 4 DUCT TAPE PERFORATED DIFFUSER TYf=ICAL DIPPUSER CONNECTION DEVIL NO SCALE AUDIBLE ALARM CONDENSING IT IN NORMALLY OCCUPIED AREA OR THROUGH . BUILDING FIRE ALARM 5Y5TEM IF APPLICABLE PIPE INSULATION-7 CONCRETE PAD 4" THICK MIN REFRIGERANT LINES TO AIR HANDLER ANCHOR W /POWER DRIVEN STUDS OR THRU CEILING SPACE 3/8"X1.5 "LG. TAP -CONS, OR LAG BOLTS W/ SHIELDS INSIDE G.U. THRU BASE PLATE TO WITHSTAND WINDS OVER 146 MPH WITH AN ANCHOR BOLT OF 500 POUNDS MINIMUM PULL OUT CAPACITY. CONDENSING UNIT INSTALLATION DETAIL NO SCALE FASTENERS r-AW3LE RIVITI =D OR SPOT WELDED AS REQUIRED 180' MIN. R/ STANDARD DUCT MADE WATER TIGHT STIFFERNERS MAY BE IN51DE. 50/50 SOLDC-_R USED AT ALL JOINTS EXPOSED TO WEATHER PREPARE GALVANIZED FINISH I } FOR A COAT OF 3 MIN, ALUMINUN PAINT I W••V VUV MAX. SPACING V • •••Yi •Yu 11/2 "x 1/8" V 4THRU 10$QPT • 4 W ii s V V • 4' -0" u i• • V V V Y V U y a� II • • N • • U 4 y W V V W • v V W y V V U LU C21 • ♦ • i Y V • y 0 • • m d ••• • *y 6 NI 0 J ( N f By o •' Z W W HCD`nin • "•Revision V • • u G V W V � V u C) _J • V • i V i i V i• W•• LL W V W V U • V p Y � V • • y U V • • y y U Y•• • Vii • V u y V Y y• i• i I A R W/2 TAI FICAL EL,4eH1NC� DETAIL ■ 111z" SCREEN DUCT SIZE +2'y' FLASHING 24" MIN- FLASHING CURB ROOF ING � ROOF IWG ANCHOR _:X4 BOLTS 8" MIN. W x CsALV_ STRUCTURAL COPPER CURB �— �- CONCRETE DECK STEEL ANGLE WELD PITCH SPECIFIED DUCT SUPPORT (TWO PAN 5izE REQUIRED) 6XroXl 14 STEEL PLATE METAL ROOF DECK T'I'1'ICAL RECTANGULAF OR ROUND, O /,4 4 EX /,4 GOOSENECK INSTALLATION DETAIL. N.TS PESFORATED CAP MIN. 12" ABV AHU DRAIN PAN. VENT SAME SIZE J AS DRAIN CONDENSATE DRAIN CONNECTOR N.T.S CONCRETE SLAB �CONGRETE SCREW ANGER STRAP 1 i2 ", 22G C FOR DUCTS OVER 48" WIDE, FASTEN UNDER BOT OF DUCT. DUCT 517E HANGER 817E MAX. SPACING UPTHIRU 2 50PT 12 "x I/6" 8' -0" 2 THRU 450.FT. 11/2 "x 1/8" E' -fd" 4THRU 10$QPT IV "x 11611 ral -0" OVER 1050FT I1/ "x 1/8" 4' -0" _ —I'/2" MIN. STROP 26 G DUCT HANGING DEVIL N.T_S ROUND FLEX DUCT. n an cn In W Ll. L �y Q W Z W W a� II N � W LU w© � II 0 z� LU C21 Z cf) P Z J 5 J Ul LL = CO 0 =D LL! ap m d i � <C6 & N 6 NI 0 J ( N f Z cn In W Ll. Q W Z W W N � W LU w© 0 z� LU C21 Z V P Z J 5 J Ul LL = CO 0 =D LL! ap m d i � <C6 & N o LL 0 J ( N f Z Z HCD`nin � o U � C) _J U H LL W DRAWN SY: LIDS, RRIETO RU51 ORTEGA Checked: P. G -P Date: MAT --I -0a SGa le: Shown Job No: Sheet: -- 2 To the best of my knowledge subject drawing comply with FBC. Dade County require a Final Letter of Compliance from Architect. Any deviation of approved drawing is subject to revision by Architect /Engineer. Contractor or sub contractor shall notify Engineer prior any change to be done on approved drawings.