Loading...
10-558-020MECHANICAL GENERAL NOTES: 1. ALL AIR CONDITIONING (COLD AIR) DUCTWORK TO BE ON MIN. R -6 FIBERBOARD: THE FABRICATION AND INSTALLATION OF ALL DUCTWORK, TOGETHER WITH RELATED EQUIPMENT, SHALL COMPLY WITH "SMACNA" DUCT CONSTRUCTION STANDARDS, NFPA 90A & 90B, LATEST ADDITION OF ASHRAE GUIDE do DATA BOOK, AS DETAILED ON THE DRAWINGS do PER LOCAL CODES. 2. FURNISH do INSTALL ALL MOUNTING SUPPORTING OF FC'S, DUCTWORK do ACCESSORIES INCLUDING HANGERS, SUPPORTS, CLAMPS, BRACKETS, ACCESS DOORS AND DAMPERS REQUIRED FOR THIS INSTALLATION. 3. DUCTWORK CONTRACTOR SHALL INSPECT, EXAMINE AND TEST ALL AIR DISTRIBUTION DUCTWORK SHOWN ON THE DRAWING FOR AIR LEAKAGE. THE DUCTWORK CONTRACTOR SHALL PATCH AND REPAIR ALL LEAKS FOUND IN THE AIR DISTRIBUTION SYSTEM. 4. DUCTWORK CONTRACTOR SHALL INSTALL ALL DUCTWORK TO ADHERE TO THE ARCHITECTURAL CEILING HEIGHTS. 5. DESIGN INTENT CONSTITUTES THE PROVISION OF COMPLETE SYSTEMS AS INDICATED WITH ALL NECESSARY COMPONENTS AND ACCESSORIES WHETHER EXPLICITLY SPECIFIED OR IMPLIED TO ACHIEVE FULL OPERATIONAL STATUS. 6. THE DUCTWORK CONTRACTOR SHALL VERIFY do FIELD MEASURE PRIOR TO FABRICATION OF DUCTWORK. 7. PENETRATION OF DUCTWORK BY PIPES, CONDUITS, ELECTRICAL FIXTURES, OR STRUCTURAL MEMBERS IS NOT ACCEPTABLE. 8. THE GENERAL CONTRACTOR SHALL PROVIDE ALL ROUGH OPENINGS THROUGH STRUCTURAL WALLS, FLOORS, AND /OR ROOF REQUIRED FOR THE DUCTWORK SYSTEM. 9. FURNISH AND INSTALL FLEXIBLE CONNECTIONS BETWEEN FANS AND DUCTS OR EQUIPMENT CASINGS. 10. EXACT LOCATIONS OF THERMOSTATS SHALL BE COORDINATED WITH OTHER DISCIPLINES TRADES, ROOM FURNITURE & A/E BEFORE INSTALLATION. 11. DRAWINGS ARE DIAGRAMMATIC AND SHOW LOCATION INTENT. CONTRACTOR IS TO COORDINATE SYSTEM LAYOUTS WITH OTHER DISCIPLINES TO AVOID CONFLICTS AND FACILITATE ACCESSIBILITY FOR SERVICING 12. DRAWINGS INDICATE APPROXIMATE LOCATION OF CEILING MOUNTED DEVICES. EXACT LOCATION IS TO BE COORDINATED WITH ARCHITECTURAL REFLECTED CEILING PLANS. 13. FIRE SAFE AROUND ALL PIPE PENETRATIONS THROUGH RATED WALLS. 14. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND EXECUTION OF ALL NECESSARY CHANGES ATTRIBUTABLE TO INSTALLATION OF SUBSTITUTE EQUIPMENT AT NO ADDITIONAL COST TO OWNER. 15. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 16. CEILING DIFFUSERS AND GRILLES TO BE COORDINATED WITH ARCHITECTURAL CEILING LAYOUT PLANS. 17. THE DUCTWORK CONTRACTOR SHALL COORDINATE HIS WORK WITH BOTH THE ELECTRICAL AND CEILING CONTRACTOR THROUGHOUT THE ENTIRE PROJECT. 18. ROUGH OPENINGS IN FLOOR AND WALLS INDICATED ON THESE DRAWINGS ARE APPROXIMATE, CONTRACTOR MUST CHECK SHOP DRAWINGS FOR ACTUAL SIZES. 19. ALL MATERIALS AND EQUIPMENT SHALL BE PROPERLY AND EFFECTIVELY PROTECTED BY THE CONTRACTOR DURING THE EXECUTION OF THE WORK. 20. OUTLETS AND EQUIPMENT LOCATIONS ARE DIAGRAMMATIC, FINAL LOCATIONS WILL BE DETERMINED BY FIELD CONDITIONS AND /OR AS DIRECTED BY THE A /E. 21. ALL INSTALLATION WORK SHALL COMPLY WITH THE FLORIDA BUILDING CODE (FBC), THE STANDARDS OF THE AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR CONDITIONING ENGINEERS ( ASHRAE), AND THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). THE CONTRACTORS MUST FAMILIARIZE THEMSELVES WITH THE ABOVE REFERENCED CODES /GUIDELINES BEFORE BIDS. THE ACT OF BIDDING THIS PROJECT CONSTITUTES THE UNDERSTANDING OF ALL INFORMATION DEPICTED IN THE CONTRACT DOCUMENTS (INCLUDING BUT NOT LIMITED TO PROJECT SPECIFICATIONS, IF ISSUED, AND PROJECT DRAWINGS). 22. DRAWINGS FROM VARIOUS DISCIPLINES ARE INTERRELATED. WHAT IS REQUIRED IN ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. COMPLEMENTARY COMPONENTS BETWEEN DISCIPLINES, REASONABLE INFERRED AS BEING NECESSARY TO PRODUCE INTENDED RESULTS, SHALL BE DEEMED PART OF THE CONTRACTOR'S EXPECTED PERFORMANCE 23. FLEXIBLE DUCTS ARE LIMITED TO 8' -0" LENGTH. WHERE DUCT LENGTH FROM BRANCH TAP TO OUTLET EXCEEDS 8' -0" THE DIFFERENCE IN LENGTH SHALL BE PROVIDED WITH A RIGID DUCT RECTANGULAR OR SPIRAL ROUND OF AN EQUIVALENT CROSS SECTIONAL AREA. MECHANICAL SYMBOLS (GENERAL) XX -1 EQUIPMENT TAGS (XX = MARKS BELOW) BHP SF = SUPPLY FAN BTU EF = EXHAUST FAN CD AHU = AIR HANDLER UNIT CFM CU = CONDENSING UNIT MECHANICAL ABBREVIATIONS AFF ABOVE FINISHED FLOOR BHP BRAKE HORSE POWER BTU BRITISH THERMAL UNIT CD CONDENSATE DRAIN CFM CUBIC FEET PER MINUTE DB DRY BULB OR DECIBELS DN, DOWN DWG DRAWING EAT ENTERING AIR TEMPERATURE EDB ENTERING DRY BULB TEMPERATURE E/A EXHAUST AIR ESP EXTERNAL STATIC PRESSURE FLA FULL LOAD AMPS FLD FULL LOUVERED DOOR FPM FEET PER MINUTE HP HORSE POWER HZ HERTZ INWG INCHES OF WATER GAUGE NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER PH. PHASE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH (GAUGE PRESSURE) R/A RETURN AIR S/A SUPPLY AIR SP STATIC PRESSURE T/A TRANSFER AIR TSP TOTAL STATIC PRESSURE TYP. TYPICAL MECHANICAL SYMBOLS (HVAC) YES SUPPLY AIR DIFFUSER (SEE AIR DEVICE SCHEDULE) ARROWS DENOTE BLOW PATTERN. DUCT SMOKE DETECTOR NO ARROWS INDICATE 4 -WAY BLOW. X RETURN /EXHAUST AIR GRILLE (SEE AIR DEVICE SCHEDULE) ® AIR DEVICE DESIGNATION (SEE SCHEDULE) 4 -100 UC FIRE RATED ENCLOSURE UNDERCUT DOOR Sp SMOKE DETECTOR OT NEW THERMOSTAT DUCT SIZE DESIGNATION. FIRST DIMENSION IS DUCT WIDTH.. 24X12 SIZE SHOWN IS INTERNAL CLEAR OPENING. SHEET METAL X SIZE MUST BE INCREASED FOR INTERNAL INSULATION WHERE SPECIFIED. (0= ROUND DUCT, -e�- = FLAT OVAL DUCT) ----D- DUCT TRANSITION -+ DUCT END CAP -'' SUPPLY AND RETURN /TRANSFER GRILLE WALL MOUNTED. --�` ARROWS DENOTE SUPPLY /RETURN AIR PATH. FLEXIBLE DUCT MANUAL VOLUME DAMPER CEILING MOUNTED EXHAUST FAN HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPER(S) X FIRE RATED ENCLOSURE X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X mi.00 Er•u •V• V 4 •Viii •iii+ • U • V (4 . E V • • • • • V V V V V V• V • r U u u U u V V V v V U V U • AD.,D.l-T-0.N—,-& • c U RAT! C E ALTEON T -0 . • ••i• V E i NATA A �.Yra• A,--&' FERNANDO'S RESIDENCE 5901 S.W. 81 STREET SOUTH MIAMI, FL 33143 k {t U3�, r, 1� ELECTRICAL ENGIrMERS V� ERNESTO *LOMA P.E. 53823 MANUEL P. MONTOYA P.E. 66220 HECTOR J. CASTILLO P.E. 65405 ALBERTO M. MALAYS P.E. 70692 MECHANICAL ENGINEERS JOSE I. MARTINEZ P.E. 53779 RODRIGO I. MENEZES P.E. 69008 ow "/ 5m CONSULTING ENGINEERS 135 ALMERIA AVENUE CORAL GABLES, FLORIDA 33134 (305) 446 -2785 (PHONE) (305) 443 -5944 (FAX) EB- 00003791 www.sdmcorp.com XDO c J+ lu?wo; ASSOCIATES, P.A. ARCHITECTS 500 SOUTH DIXIE HWY, SUITE 303 CORAL GABLES, FL, 33146 PH. (305) 665 -0641 MAY 59 2010 JOHN E. JUNKIN AR 006454