Loading...
10-558-003DEMOLITION DEMOLITION NOTES 1. CONTRACTOR TO COORDINATE WITH OWNER REGARDING ANY SALVAGEABLE ITEMS REMOVED PRIOR TO DEMOLITION. ANY ITEMS INDICATED THAT ARE OF SALVAGEABLE BE REMOVED CONDITION ARE TO BE BROUGHT TO THE OWNERS ATTENTION SO THAT THEY MAY BE RELOCATED PER THEIR DIRECTION. 2. ALL EXISTING EQUIPMENT AFFECTED BY NEW CONSTRUCTION SHALL BE REMOVED/ RELOCATED. VERIFY LOCATION WITH OWNER. 3. CONTRACTOR SHALL FILL, PLUG, AND REMOVE ALL EXISTING PLUMBING PIPE LOCATIONS AND ANY OTHER MECHANICAL ITEMS SO AS TO PREPARE AREA FOR NEW CONSTRUCTION. 4. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT TO • DISCONNECT, DISMANTLE, REMOVE, AND SALVAGE IN THE DISPOSITION OF ••r•• DEMOLITION INDICATED IN THIS PLAN. 5. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO •u•u EXISTING STRUCTURE OR EQUIPMENT CAUSED BY THIS OPERATION AND SHALL NOT INTERFERE WITH EXISTING STRUCTURAL SYSTEM. 6. HOLES OR OTHER DAMAGE LEFT BY CONTRACTOR SHALL BE REPAIRED BY CONTRACTOR AT HIS OWN EXPENSE. 7. UPON COMPLETION OF DEMOLITION THE ENTIRE AREA SHALL BE CLEANED OF ALL DEBRIS AND PREPARED FOR NEW CONSTRUCTION. 8. EXISTING CONDITIONS NOT SHOWN ON THIS PLAN SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO REMOVAL AND /OR REWORKING TO CONFORM TO NEW PLAN AS REQUIRED. 9. THE GENERAL SHALL PROVIDE ALL NECESSARY BARRICADES AND SAFETY BARRIERS AS REQUIRED BY WORK INCLUDING DUST CONTROL MEASURES. 10. THE CONTRACTOR SHALL PREPARE ALL EXISTING SURFACES AND CONDITIONS AS NECESSARY TO RECEIVE ALL NEW WORK. 11. THE CONTRACTOR SHALL EXAMINE ALL CONDITIONS AND VERIFY ALL DIMENSIONS BASED ON EXISTING CONDITIONS AND SHALL CONTACT ARCHITECT FOR CLARIFICATIONS OR INTERPRETATIONS AS NECESSARY FOR A COMPLETE JOB. 12. THE CONTRACTOR SHALL REMOVE EXISTING ROOF SYSTEM AND STRUCTURE AS NECESSARY TO TIE NEW ROOF STRUCTURE TO EXISTING. SEE ROOF PLAN. DEMOLITION WALL LEGEND WALL TO REMAIN C _ _ WALL TO BE REMOVED =ER: WINDOWS TO BE REMOVED !V II \ EXISTING DOOR TO BE REMOVED I yI T I I POOL I EXISTING POOL DECK TO BE REMOVED 1 I / \ I \ I ' \ I ' � I ' \ I ' I I I I _ I / / I 1 --- _----- - - - - - 1 EXISTING POOL DECK I TO BE REMOVED EXISTING COLUMNS TO BE REMOVED I I AFTER TIE -BEAM REINFORCING AND I NEW COLUMN IN PLACE I I IIII I IIIIII I IIIIII IIIIII I IIII I IIIIII 1 IIII IIII I I�I I�I I I IIII I IIIIII 1 °i 111 i FAMILY ROOM Jill i 1 11 1 1 1111 � IF�I If�l I IIII IIII IIIIII IIIIII 1 IIIIII IVIII I VIII I I VII I I L - - - - - - - - - - - - - - - EXISTING WINDOWS TO BE REMOVED, CREATE OPENING FOR NEW DOORS I I I L -J LL J LL — -- _= ___ -___ - - -- ---- -------- - - - - -- I EXISTING COLUMNS TO BE REMOVED I I I J� J I l i l I I III I I AFTER TIE -BEAM REINFORCING AND I L - - - - - - - l = = = J-- - -- - - - - -4 L - I I III y IIII NEW COLUMN IN PLACE Li I - - - I III II IIIIII - _ I I I I EXISTING BATHROOM FIXTURES III I I I I IIII IIIIIIIIIIII II I I I I I II1�I IuIIII 1 I I — _ III l , ` II ��� � IIII I I 1 i 1 � r A\ / J I I I I I I I I I I iII I iII i I I u III I TO BE REMOVED �- � �J, TH #1 DINING KITCHEN ING KITCHEN CABINETS, W I IIII EXIST � ))III 11 I ,111 APPLIANCES, SINK AND: PARTITION TO BE — 1 DEMOLISHED I I— -I BEDROOM #2 II IL I I III I I IIIIII I �I I� � II I � I LJ11_J I EXISTING WALL TO 11l II I L - - - ll II I I I I IIII BE DEMOLISHED I II —_ - - -- _ = __ = L---------------- - - - - -- JI - - qL L I — r -- \ II I r --- 5_ — -- � -- EXISTING WALLS, WINDOWS AND ------ - - - - -- II I � � �1 __- I II DOORS TO BE DEMOLISHED (TYPICAL) I I IIII / II I----------- ff � II 11 IL--- .----- - -LL I I� -- i1 II II EXISTING BATHROOM 1 B ^r�yu FIXTURES TO BE REMOVED 1 11 II 1 I 11 II FT ' -� 11 111 I 1 BEDROOM #2 I� - - - - - -- —J I I II III— - - - - - - - �­I I EXISTING CONCRETE SLAB I �I II III I I AND ROOF TO BE DEMOLISHED I- I L L-= 1 II II 11 II II II hA I IIII I I IIII I IIII I I IIII I II II �I LL = -- r-------------- L= = = = = =T EXISTING ENTRY, SIDEWALK AND DRIVEWAY TO BE REMOVED — LIVING ROOM EXISTING DOOR TO BE REMOVED, INCREASE OPENING FOR NEW DOUBLE DOOR ff - -_ I II // II / I�_I -- -� - - - - J EXISTING WINDOWS TO BE \ REMOVED, INCREASE OPENINGS `\ FOR NEW WINDOWS II I II I I I III I I I III I I III L I I II I I I II I I I II I I I II I I I III � I I III II I III II EXISTING PARTITION WALLS AND DOORS TO BE DEMOLISHED (TYPICAL) BEDROOM #I EXISTING WINDOWS TO IRE REMOVED, CREATE OPENING FOR NEW HALLWAY KF- DEMOLITION PLAN SCALE: 1/4" = V -0" 11 II I II I I IIII I IIII I I I I IIII I I IIII I I IIII i I IIII I I.u.I I IIII I I IIII I I IIII I ill �i I IIII I IIIIII I I I I I I I I I I I I I I I I I I I I I I I I �- �C71Ot`I S7 Iv-, ju �F7,OVy \ CUILD14NG pt PT. GUILDIN'G I { dirt p.l JI i EXISTING SIDEWALK TO BE REMOVED A2.01 I i I �?.DDYTOiN & ALTYRI�TIJON .. TO, .,THE. €:1VI7t,TlV•I�:•LA RESIDENCE 5901 S.W. 81 STREET SOUTH MIAMI, FL 33193 C ITY OF SOUTH iv1IAM1 13UILDING DEPT. TRUCTURAL SECTION A'-,PROVED SY: w * ' I STRUCTURAL BLISS & NYITRAY, INC. 800 DOUGLAS ROAD, SUITE 300 CORAL GABLES, FLORIDA 33134 (305) 442 -7086 H.V.A.C., PLUMBING, do ELECTRICAL SDM CONSULTING ENGINEERS, INC. 135 ALMER.IA CORAL GABLES, FLORIDA 33134 (305) 446 -2788 1Fw4eJ13w ASSOCIATES, P.A. ARCHITECTS 500 SOUTH DIXIE HWY, SUITE 303 CORAL GABLES, R. 33146 PH. (305) 665 -0641 JUNE 1E, 2010 JOHN E. JUNKIN AR 006454 I x Sy i f� I� • Y• rV iJ • • • !V r u • • r ••r•• �rr•� • • o •u•u r • • �?.DDYTOiN & ALTYRI�TIJON .. TO, .,THE. €:1VI7t,TlV•I�:•LA RESIDENCE 5901 S.W. 81 STREET SOUTH MIAMI, FL 33193 C ITY OF SOUTH iv1IAM1 13UILDING DEPT. TRUCTURAL SECTION A'-,PROVED SY: w * ' I STRUCTURAL BLISS & NYITRAY, INC. 800 DOUGLAS ROAD, SUITE 300 CORAL GABLES, FLORIDA 33134 (305) 442 -7086 H.V.A.C., PLUMBING, do ELECTRICAL SDM CONSULTING ENGINEERS, INC. 135 ALMER.IA CORAL GABLES, FLORIDA 33134 (305) 446 -2788 1Fw4eJ13w ASSOCIATES, P.A. ARCHITECTS 500 SOUTH DIXIE HWY, SUITE 303 CORAL GABLES, R. 33146 PH. (305) 665 -0641 JUNE 1E, 2010 JOHN E. JUNKIN AR 006454 I x Sy i f� I�