00-498-0051. 2. 3. 4. 5. 6. 7. 8. AIR CONDITIONING SYSTEM - GENERAL NOTES COSTUMER AREA DUCTWORK SHALL BE EXPOSED PANTED ROUND SHEET METAL. OFFICE, KITCHEN AND BATHROOMS DUCTWORK SHALL BE 1 1/2" THICK. 3 POUNDS PER CUBIC FOOT DENSITY FIBERGLASS WITH VAPOR BARRIERS, UNLESS OTHERWISE SPECIFIED. DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & ACCORDING TO "ASHRAE" & "SMACNA" STANDARDS. DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY W / "NFPA" STD. NO. 90A AND /OR 90B. DUCTWORK AND COMPONENTS SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 TESTS. COORDINATE LOCATIONS, SIZES & OPENINGS W /OTHER TRADES ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT SYSTEM W /TURNING VANES AT ALL ELBOWS, SPUTTERS & DAMPERS, AS REQUIRED. DIFFUSERS SHALL BE SELECTED, LOCATED AND BALANCED IN ORDER THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY & DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: INSIDE OUTSIDE RELATIVE HUMIDITY COOLING — 76 DB 91 DB — 79 WB 50% TO 60% HEATING — 70 DB 45 DB ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, AS REQUIRED TO OPERATE QUIETLY SO THAT NO OBJECTIONABLE SOUND WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT. A/C SYSTEM SHALL HAVE DISPOSABLE AIR FILTERS LOCATED AS REQUIRED FOR EASY ACCESSIBILITY. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT, MOUNT THERMOSTAT 5' -0" ABOVE FINISHED FLOOR. U.O.N. ALL GRILLES & DIFFUSERS TO BE PAINTED STEEL CONSTRUCTION. DIFFUSERS SHALL HAVE HIDDEN OPPOSED BLADE DAMPERS. PROVIDE GASKETS ON ALL GRILLES & DIFFUSERS. TITUS OR AIREGUIDE FINISHED COLOR BY ARCHITECT. UNDERCUT DOORS, 1" A.F.F. AS INDICATED. FROM OTHER DETECTOR (IF APPLICABLE ) BHT INDICATOR AUDIBLE ALARM IN NORMALLY OCCUPIED AREA IONIZATION aiOKE DETECTOR (SEE HVAC PLANS) EVAPORATOR FAN MOTOR AUXILIARY CONTACT TO SHUT DOWN UNIT IN CASE OF SMOKE SENSING AIR CONDITIONING DUCT SMOKE DETECTOR WOOD BURNING PIZZA OVEN VENTILATION DETAIL FAN SCHEDULE FAN No. MANUFACTURER AND MODEL No. RPM HP CFM 8 SP. ELECT SERVICE V /O/HZ DIMEN71ONS W x L x H (IN )NEIGHT LBS. REMARKS TYP. TOILET RM. E)GiAUST FAN 3 do QTONE ,500 1/410 100 O 1/8- 115/1 /60 9 x 9 x 4 6 W1 GRILLE 4'0 DUCT ROOF CAP 60/60 9.20 -- 890 POUNDS 50" 88" 451/2 910 CFM REPLACEMENT OF EXISTING UNIT R RETURN AIR 48" X 24" PAR 3/8" GUY WIRE (4 SIDES) 16 GAUGE WELDED STEEL EXH. DUCT (DOUBLE WALL) ROOF CURB MANUF. -5/8" 0 TURNBUCKLE —PITCH PAN 5/8" 0 HOOK ANCHORED TO ROOF STRUCTURE ROOF STRUCTURE CONC. BLOCK 22 GAUGE GALV. OR STAINLESS STEEL PLATE WOOD BURNING OVEN AIR CONDITION EQUIPMENT SCHEDULLE SYMBOL MARK MANUFACTURER MODEL TONS CFM ELECTRICAL V PH HZ CIRCUIT BREAKER EER SEER WEIGHT DIMENLONS H 0/A AIR B DISTRIBUTION TRANE TCD120 10.0 4000 240 3 60 60/60 9.20 -- 890 POUNDS 50" 88" 451/2 910 CFM REPLACEMENT OF EXISTING UNIT R RETURN AIR 48" X 24" PAR RIGID FIBERGLASS DUCT SPIN COLLAR WITH VOLUME DAMPER AND LOCKING QUADRANT INSULATED FLEXIBLE DUCT GLASS 1 1/2- WITH POLYETHYLENE JACKET AND STEEL WIRE REINFORCING OFFICE AND RESTROOMS TAKE - OFF DETAIL NTS � 1 ECH AN I CAL PLAN ;ALE: 1/4" = V -0" OUTSIDE AIR CALCULATIONS PER ASHRAE 62 -89 1.) CUSTOMER AREA MAX.: 40 CUST. 3 EMPLOYEES 0/A CFM REQUIRED 20 CFM / PERSON CFM = 43 X 20 = 860 2.) KITCHEN AREA = 169 S.F. 0 /A. AIR REQUIRED 15 CFM /PER 20 PERSONS/ 1000S.F. CFM = 20 X 169/1000 X 15 = 50 TOTAL CFM . REQUIRED = 910 CFM PROVIDED 910 AIR DISTRIBUTION SCHEDULE SYMBOL USE CFM TYPE DESCRIPTION NECK PANEL MAT'L DESIGN, MFGR. & MODEL CFM A DISTRIBUTION 460 SURFACE MOUNTED 12" 0 24 X 24 MS PAS B DISTRIBUTION 280- 10" z 24 X 24 MS PAS C DISTRIBUTION 100 6" z 12 X 6 TITUS PAS R RETURN AIR 48" X 24" PAR w J Q W U 5 rr W X W HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR FIRE DAMPER (S) SMOKE DAMPER (S) / V FIRE RATED ENCLOUSURE FIRE RATED ROOF FLOOR CEILING ASSEMBLY FIRE STOPPING SMOKE CONTROL 1� • Fes. r � '/ r �- r PROJECT No °0 0 Z ° � N w G N = U) FILE: solerest 0 O J u_ I-- Z Q _ry ZQ Q~ LLI> Qry� I- Q LLJ N (w a ry—D� V) J3: �� Ozc000 Cn J Ul Q �O W (j:f D_ O Q O N O O O Q O 00 Z 00 O N F- I Q Of c0 F- O V) .-. (.D LQ LLI O a p J LLI O ~ J LL_ to V_ M U M W 0 O J Li U _N F_ cr LLI 0 V♦ ) , N 0Lr 00