00-498-004CAP FOR FUTURE -
CONNECTION SOLAR
OR HEAT RECOVERY
GATE VALVE
HEAT TRAP
H.W. TO FIXTURES
HOT WATER, 3/4
UNION
3/4" GA�
DRAIN VALVE
3" N FLUE CLASS I
W/ A6A APPROVED
HEAT TRAP
GATE VALVE
' COLD WATER, 314
UNION
i
el
PRESSURE & TEMF
RELIEF VALVE (ASI
3/4" Cu RELIEF DI
GAS LINE, TO OUTSIDE
HEATER AREA, TERMINATE
75 GAL. ABOVE FIN. GRADE
96,000
BTU
WATER HEATER PIPING DIAGRAM
NO SCALE
PLUMBING GENERAL NOTES AND SPECIFICATIONS:
1. A. SCOPE OF WORK:
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE
DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE
SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO:
1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS
2. SANITARY DRAIN AND VENT SYSTEMS
3. PLUMBING FIXTURES AND TRIM
4. AIR CONDITIONING CONDENSATE DRAINS
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER
6. PIPING INSULATION
7. SUPPORTS AND HANGERS
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
EDITION OF THE "SOUTH FLORIDA BUILDING CODE" CH. 46 LOCAL ORDINANCES
AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR
BUILDING CONSTRUCTION ", AND "HRS" REGULATIONS. IN THE EVENT OF
CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT
REQUIREMENTS WILL GOVERN.
2. CONTRACTOR TO VERIFY AT SITE THE LOCATION, ELEVATION AND SIZE OF ALL
EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING.
3. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS
WATER METER
& VALVE CEILING PLAN
1"
SCALE: 1/4" = 1' -0"
OR SHOCK ABSORBERS AS INDICATED ON PLANS.
1
4. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS,
SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS
AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED.
FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. AIR CHAMBERS
5. SANITARY PIPES TO BE PVC SCH. 40. SLOPE U.G. PIPES 3" AND ABOVE 0 1 /8 " /FT.
SANITARY PIPES 2" & SMALLER SLOPE AT 1 /4 " /FT. 1/2.. 3/4"
6. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT
EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS
AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE.
7. VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH LEAD.
S. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND TO BE
COPPER TYPE "L ". OR APPROVED CPVC NO JOINTS ALLOWED UNDER SLAD
9. PIPING
A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER
INTERVALS ACCORDING WITH CODE.
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR
MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES.
C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE
ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE
DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES. PROVIDE
CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS.
10. INSPECTIONS AND TESTS
A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS, TO THE
AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL
SYSTEMS SHALL BE TESTED BY CODE AND /OR LOCAL REGULATIONS.
B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF
SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE
HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE BY AN
OWNER REPRESENTATIVE.
11. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED
LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE).
RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER
BEFORE PLACING IN SERVICE.
12. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST
AFTER COMPLETION OF THE INSTALLATION.
3��W3/4"
AIR CHAMBERS ALVES
3/4"
HW
1 /2" /2.. 3/4- 1
AIR CHAMBERS 1/2" Q Q
3/4"
AIR CHAMBERS CW
1/2"
H W 1 /`
3 COMP SINK 3/4"
1 /2�2" CW
HAND 1SINK WCN
WC,.i J LAV
1/2" LAV 1 /2"
1/2'
LAV1 /2" 3/4"
R
31/2"P SINK WATER RISER DIAGRAM
N.T.S.
60 GAL.
WATER HEATER
ELECTRICAL
DP SINK
/2 "
`0_1 /2"
AIR CHAMBERS
7"
2
LAV -- �WC
2" V.T.R.
2 "1
1
3 C
CO
3" F. D. Jv
\4
EXIST SEWER LINE
EXIST GREASE TRAP
K �
PNL.
..� 3
-12
2" 2" V. T. R. J
r
2„ I SINK
I 3 COMP
I SINK , ii
HAND SINK
SINK
C
4" GR.. LINE
3
E" X I S T
I � N%
elDj
WC FD LAV
LAV V I,
3 �V.T.R.
J
EXIST
CO*
I EXIST
3» V. T. R.
J I,
II\�N% EW
/I N%
I 1
� I
(
LAVI
AV I WC
ALL FLOOR DRAINS ",1001
SHALL BE CONNECTED TO AN
AUTOMATIC PRIMER VALVE
SANITARY RISER DIAGRAM
N.T.S.
8'
3/4"
LONGEST RUN 50 FEET
75 GAL.
SHUT -OFF VALVE WATER HEATER
75,000 B.T.U.
GAS DIAGRAM
AIR CHAMBERS
N.T.S.
AUTOMATIC PRIMER VALVE
WITH INTEGRAL VACUUM
BREAKER
OMESTIC WATER LINE
IN TO SEWER LINE
L ,
FLOOR DRAIN RESEAL
u
NO SCALE
.s :•it: '"!a fir, �_
k _7
PROJECT No
0
o N ZN
w I
N W
N=
N
FILE:
solerest
o'
OO',
J
LL_
z
Q
I
zQ
Q�
w>
Quo
W N V) '
j2�CL �:2
Ld (n
-j3:��
-q-
0 0)
J
(n Q
>
O
Ld
tY
Z CL
O Q
M
O
N
O
O
O
D!
Q C
z oc
O n
1= I
F
V
O C
LLJ � M
LL
O F_
J
u- u;
Lr
0 r
M
M,
W a
O
J LL
Z
Ua
N
W
0 Q
N
CV
vi
0